N15926, cancelled Mar 3, 2023
Service difficulty reports · 149
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N15926' AND deregistration_id = 'N15926-2023-03-03' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N15926' AND deregistration_id = 'N15926-2023-03-03' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA201400710211Door Frame · corrodedDURING C-CHECK, THE SERVICE DOOR LOWER FRAME WAS FOUND TO BE CORRODED. MAINTENANCE R & R THE FRAME IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA201400710210VDoubler · crackedDURING C-CHECK THE SERVICE DOOR FORWARD LOWER STOP MOUNT DOUBLER WAS FOUND TO BE CRACKED AT FRAME 20, STRINGERS 13-14R. MAINTENANCE R & R THE DOUBLER IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140710209Support · corrodedDURING C-CHECK THE LAV WASTE DRAIN SUPPORT WAS FOUND TO BE CORRODED. MAINTENANCE R & R THE SUPPORT IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140707206Frame · corrodedFRAME 61 HAS CORROSION ON UPPER FLANGE BETWEEN S21L - 21R. REPAIRED FRAME IAW EC5310-01787. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140707205Frame · corrodedFRAME 50 CORRODED BETWEEN STR 21R AND 21L. REPAIRED FRAME IAW EC5310-01791. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140707204Skin · corrodedCORROSION ON SKIN AT FRAME 69 BETWEEN S18-19L. REPAIRED SKIN IAW EC5330-02920. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140707203Floor Support · corrodedCORROSION ON CENTER AISLE LT SUPPORT AT FRAME 34. REPAIRED OMEGA BEAM IAW SRM 53-00-10. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140705202Floor Support · crackedCRACKED RT OTBD OMEGA BEAM SUPPORT AT FR 47-48. R & R RT SIDE OTBD OMEGA BEAM SUPPORT IAW SRM 51-40-02. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140705201VFloor Support · crackedCRACKED RT INBD OMEGA BEAM SUPPORT AT FR 47-48. R & R RT OMEGA BEAM SUPPORTS BETWEEN 47-49 IAW SRM 51-40-02. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140705200Retaining Ring · corrodedWASTE DOME RETAINING RING CORRODED. R & R RING DIGITAL IAW SRM 51-40-02. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703197Floor Support · corrodedDURING C-CHECK, ON REMOVAL OF REPAIR DOUBLER FOUND CORROSION, 100 PERCENT THROUGH THE RT FLOOR SUPPORT BETWEEN FRAMES 18-19. MAINTENANCE R & R FLOOR SUPPORT IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703196Floor Support · corrodedRT OMEGA BEAM DIGITAL HAS SEVERAL AREAS OF CORROSION AT FRAME 61. MAINTENANCE REMOVED CORROSION, 100 PERCENT MATERIAL LOSS. REMOVED DIGITAL PANEL, LOCATED, DRILLED AND INSTALLED NEW RT OMEGA BEAM DIGITAL PANEL AT FRAME 61 IAW SRM 51-40-02 AND 51-21-04. ACFTSDR ASOA20140703195Floor Support · corrodedDURING C-CHECK, RT FLOOR SUPPORT AT FRAME 61 HAS CORROSION. MAINTENANCE R & R RT FLOOR SUPPORT IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703194Floor Support · corrodedDURING C-CHECK, CENTER OMEGA BEAM DIGITAL HAS SEVERAL AREAS OF CORROSION AT FRAME 61. MAINTENANCE REMOVED CORROSION, FOUND OUT OF LIMITS AND R & R THE FLOOR SUPPORT IAW SRM 51-40-02 AND 51-21-04. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703193Floor Support · corrodedDURING C-CHECK, CORROSION FOUND ON LT FLOOR SUPPORT FRAME 61. MAINTENANCE R & R FLOOR SUPPORT IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703192Floor Support · corrodedDURING C-CHECK, CORROSION FOUND ON RT FLOOR SUPPORT FRAMES 29-31. MAINTENANCE R & R RT FLOOR SUPPORT IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703191Floorbeam · corrodedDURING C-CHECK, FLOORBEAM CAPS WHICH SEAT TRACKS ARE ATTACHED TO ARE CORRODED BOTH SIDES. MAINTENANCE REPAIRED FLOORBEAM IAW EC5310-01793. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703190Floor Support · corrodedDURING C-CHECK, FLOOR SUPPORT CORRODED. MAINTENANCE REPAIRED FLOOR SUPPORT IAW EC5310-01800. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703189Floorbeam · corrodedDURING C-CHECK, CAPTAIN`S FLOORBEAM CAP WHICH SEAT TRACKS ARE ATTACHED TO ARE CORRODED. MAINTENANCE REPAIRED FLOORBEAM CAPS IAW EC5310-01793. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703188Bracket · corrodedDURING C-CHECK, BRACKET FOR SIX PINS WHICH IS FORWARD OF RUDDER PEDALS, CAPTAIN`S SIDE IS CORRODED. MAINTENANCE REPAIRED BRACKET IAW EC5310-01793. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703187Floor Support · corrodedDURING C-CHECK, LT FLOOR SUPPORT HAS CORROSION FRAMES 18-19. MAINTENANCE R & R FLOOR SUPPORT IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703186Floor Support · corrodedDURING C-CHECK, AREAS OF CORROSION FOUND ON RT FLOOR SUPPORT FRAME 22. MAINTENANCE R & R FLOOR SUPPORT IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703185Floor Support · corrodedDURING C-CHECK, CORROSION FOUND ON LT OMEGA BEAM GUSSET FRAMES 29-30. MAINTENANCE R & R GUSSET IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703184Angle · corrodedDURING C-CHECK, ANGLE HAS CORROSION, FRAME 22, RT SIDE JUST AFT OF SERVICE DOOR. MAINTNENANCE R & R ANGLE IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703183Floor Support · corrodedDURING C-CHECK CORROSION AS MARKED LT OMEGA BEAM GUSSET FRAME 35-36. MAINTENANCE R & R GUSSETS IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703182Shear Tie · corrodedDURING C-CHECK, SHEAR TIE ON FRAME 61 HAS CORROSION, BETWEEN STRINGERS 20 AND 21R. MAINTENANCE R & R SHEAR TIE IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703181Floor Support · corrodedDURING C-CHECK, CORROSION FOUND ON CENTER OMEGA BEAM AT FRAME 20, 100 PERCENT THROUGH. MAINTENANCE R & R CENTER OMEGA BEAM BETWEEN FRAMES 16 AND 23 IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140703180Stiffener · corrodedDURING C-CHECK, STIFFNERS ON LAVATORY DOME ARE CORRODED, 100 PERCENT THROUGH. MAINTENANCE R & R STIFFENERS IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702179Floor Support · corrodedDURING C-CHECK, LEFT OMEGA BEAM CAP IS CORRODED FROM FRAMES 20-22. MAINTENANCE R & R LT OMEGA BEAM CAP IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702178Partition · corrodedDURING C-CHECK, RT WALL DOUBLER AT FRAME 60 HAS CORROSION, 100 PERCENT THROUGH. MAINTENANCE R & R RT WALL DOUBLER IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702177Support Angle · crackedDURING C-CHECK, CRACK IN LOWER FORWARD CORNER OF RT SUPPORT ANGLE FOR NLG UP-LOCK BOX. MAINTENANCE REMOVED CRACKED SUPPORT ANGLE, LOCATED, AND DRILLED AND INSTALLED NEW SUPPORT ANGLE IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702176Floor Support · corrodedDURING C-CHECK, CENTER OMEGA BEAM CAP AT FRAME 19 HAS CORROSION. MAINTENANCE R & R CENTER OMEGA BEAM CAP BETWEEN FRAMES 15 AND 23 IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702175Strap · corrodedDURING C-CHECK, RT OMEGA BEAM HAS CORROSION AROUND NUTPLATE FASTENERS FRAME 20 AND 21 AND CAP HAS CORROSION. MAINTENANCE R & R STRAP AT FRAME 20 AND 21 IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702174Shear Tie · corrodedDURING C-CHECK, SHEAR TIE ON FRAME 61 HAS CORROSION BETWEEN S21R AND 12L. MAINTENANCE R & R SHEAR TIE IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702173Floor Support · corrodedDURING C-CHECK, RAMP ANGLE ON CENTER OMEGA BEAM AT FRAME 20 HAS CORROSION, 100 PERCENT THROUGH. MAINTENANCE R & R RAMP ANGLE AT FRAME 20 CENTER FLOOR SUPPORT IAW IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702172Attach Angle · crackedDURING C-CHECK, SEVERAL CRACKS IN ATTACH FLANGE FOR PANEL ON LT UPPER INBD WING SKIN BETWEEN FRAMES 40-41. MAINTENANCE REMOVED DAMAGED PORTION, FABRICATED NEW ANGLE AND INSTALLED BETWEEN FRAMES 40-40 IAW SRM 51-40-02 AND EC5720-01079. THE ACFT WAS APPROVED FSDR ASOA20140702171Shear Tie · crackedDURING C-CHECK, SHEAR TIE AT FRAME 73 BETWEEN STRINGERS 7 - 8R FOUND CRACKED. MAINTENANCE R & R SHEAR TIE IAW SRM 53-31-04. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702170Skin · crackedDURING C-CHECK, A CRACK WAS FOUND IN UPPER END OF UPPER ACCESS PANEL FLANGE ON LT WING RIB 1 INSIDE WHEELWELL AFT OTBD CORNER. R & R ACCESS PANEL FLANGE IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702169Floor Support · corrodedDURING C-CHECK CORROSION FOUND ON FLOOR SUPPORT, FRAMES 29-30. MAINTENANCE R & R LT FLOOR SUPPORT IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702168Support · crackedDURING C-CHECK, FOUND A CRACK IN LOWER FORWARD CORNER OF LEFT SUPPORT ANGLE FOR NLG UP-LOCK BOX. MAINTENANCE R & R CRACKED SUPPORT ANGLE IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702167Seat Track · corrodedDURING C-CHECK, LEFT WALL SEAT TRACK NR 5 CORRODED, AND GOUGED FRAMES 43-48. MAINTENANCE REMOVED CORROSION AND GOUGES AND FOUND WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140702166Seat Track · corrodedDURING C-CHECK LT WALL SEAT TRACK NR 2 CORRODED. MAINTENANCE REMOVED CORROSION AND FOUND WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626162VStand Off · crackedDURING C-CHECK, RT OMEGA BEAM AT FRAME 42 PIPE STAND OFF CRACKED. MAINTENANCE R & R RT SIDE OMEGA BEAM STAND OFF AT FRAME 42 IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626161VRetainer · corrodedDURING C-CHECK, CORROSION, LOCAL LEVEL 2, AROUND RT EMERGENCY LIGHT 191 PANEL. MAINTENANCE R & R RT EMERGENCY LIGHT RETAINING RING IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626160Seat Track · corrodedDURING C-CHECK, RT SEAT TRACK NR 4 CORRODED FRAMES 43-48. MAINTENANCE BLENDED CORROSION AND FOUND WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626159Seat Track · corrodedDURING C-CHECK, RT SEAT TRACK NR 5 CORRODED, FRAMES 53-59. MAINTENANCE BLENDED CORROSION AND FOUND WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626158Seat Track · corrodedDURING C-CHECK, LEFT SEAT TRACK NR 3 CORRODED,FRAMES 29-35. MAINTENANCE BLENDED CORROSION AND FOUND WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626157VSeat Track · corrodedDURING C-CHECK, RT SEAT TRACK NR 3 CORRODED, FRAMES 35-43. MAINTENANCE BLENDED CORROSION AND FOUND WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626156Seat Track · corrodedDURING C-CHECK, LT SEAT TRACK NR 1 CORRODED, FRAMES 20-24. MAINTENANCE BLENDED CORROSION AND FOUND WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20140626155Seat Track · corrodedDURING C-CHECK, LT SEAT TRACK NR 2, CORRODED AND GOUGED FRAMES 29-35. MAINTENANCE BLENDED SEAT TRACK AND IS WITHIN LIMITS OF SRM 53-00-11. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.
Back to N15926, cancelled Mar 3, 2023