N219HM, cancelled Mar 4, 2009
Service difficulty reports · 23
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N219HM' AND deregistration_id = 'N219HM-2009-03-04' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N219HM' AND deregistration_id = 'N219HM-2009-03-04' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR BAQA087055Pump · failedFUEL PUMP WOULD NOT TURN. REPLACED WITH SERVICEABLE UNIT.SDR BAQA087531Pump · failedFUEL PUMP DOESN'T TURN FREELY. REPLACED WITH SERVICEABLE UNIT.SDR BAQA084116Flexure · delaminatedDELAMINATION OF FLEXURE. REPLACED WITH SERVICEABLE UNITS.SDR BAQA082904Indicator · malfunctionedATTITUDE INDICATOR SLOW TO CORRECT AFTER ANGLE CHANGE. REPLACED WITH SERVICEABLE UNIT.SDR BAQA081139Inverter · inoperativeINVERTER INOPERATIVE. REPLACED WITH SERVICEABLE UNIT.SDR 99ZZZX2872Relay · failedRELAY STAYS PULLED AT ALL TIMES. REMOVED AND REPLACED.SDR 99ZZZX2879Shroud · flakingCOATING FLAKING OFF OF IMPELLER SHROUD PREMATURELY. REF: MCN 69. REMOVED AND REPLACED.SDR 98ZZZX941Coupling · corrodedOUTER COUPLING HAS CORROSION ON INTERNAL SPLINES. LESS THAN 1 YEAR IN SERVICE. REMOVED AND REPLACED.SDR 98ZZZX940Coupling · corrodedOUTER COUPLING HAS CORROSION ON INTERNAL SPLINES, LESS THAN 1 YEAR ON SERVICE. REMOVED AND REPLACED.SDR 98ZZZX602Coupling · corrodedCOUPLING HAS CORROSION, PITTING ON TEETH. DAMAGED BEYOND LIMITS. REJECTED. REMOVED AND REPLACED.SDR 97ZZZX3600Flexure · debondedINSPECTION PRIOR TO INSTALLATION REVEALED SHEAR PAD TO BE DEBONDED. PART RECEIVED BAD FROM STOCK.SDR 97ZZZX3599Indicator · inoperativeATTITUDE INDICATOR INOPERATIVE. ONLY 7.6 HRS SINCE INSTALLED AFTER OVERHAUL.SDR 97ZZZX3624Indicator · failedATTITUDE INDICATOR, FLAG WILL NOT STAY PULLED.SDR 97ZZZX3625Indicator · failedPILOT SMELLED BURNING ODOR. OFF FLAG PULLED. ATTITUDE INDICATOR FAILED AFTER ONLY 40.9 HOURS INSTALLED.SDR 97ZZZX3573Indicator · inoperativeATTITUDE INDICATOR INOPERATIVE.SDR 97ZZZX1355Indicator · malfunctionedATTITUDE INDICTOR 'OFF' WARNING FLAG WILL NOT PULL.SDR 96ZZZX4655Coupling · corrodedCORROSION ON INSIDE DIAMETER OF OUTER COUPLING.SDR 96ZZZX4654Starter · vibrationSTARTER HAS 0.24 IPS VIBRATION.SDR 96ZZZX3171Transceiver · defectiveRADIO REC. AND CANNOT CHANGE FREQUENCY. REMOVED AND REPLACED.SDR 95ZZZX6585Brace · brokenBROKEN BRACE. REMOVED AND REPLACED.SDR 95ZZZX5060Housing · crackedCRACKED LIGHT HOUSING. REMOVED AND REPLACED.SDR 95ZZZX4505Light · lens crackedLIGHT CRACKED (LOWER ANTI-COLLISION LENS CRACKED). REMOVED AND REPLACED.SDR 95ZZZX5061Light · crackedLIGHT MOUNT CRACKED. REMOVED AND REPLACED.
Back to N219HM, cancelled Mar 4, 2009