NTSB investigations · 1
Matched to this aircraft by N220FR and the event date: up to this one’s cancellation.
FAA incident reports · 1
FAA accident and incident reports matched to this aircraft by N220FR and the event date: up to this one’s cancellation.
Service difficulty reports · 7
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR F3LA2021060800042Plate · corrodedDISCREPANCY: REFERENCE PEMCO N/R#10882-0697 FD/CR PII ROW 49 CABIN AFTWET AREA LH FLOOR PLATE AT FR69 AND 70-Y1732 CORRODED. DISCREPENCY NOT ADDRESSED. CORRECTIVE ACTION: REMOVED AND REPLACE SHEER PLATE AT LH/R/H FR 68.10 IAW A320 SRM51-42-11-44-11.SDR F3LA2021060800041Plate · corrodedDISCREPANCY: REFERENCE PEMCO N/R#10882-0690 FD/CR PII ROW 49 CABIN AFTWET AREA RH FLOOR PLATE AT FR69 AND 70-Y1732 CORRODED. DISCREPENCY NOT ADDRESSED.
CORRECTIVE ACTION: REMOVED AND REPLACE SHEER PLATE AT R/H FR 68.10 IAW A320 SRM51-42-11-44-11.SDR F3LA2021033000027Slide · faultedAFT EMERGENCY LIGHT ISSUE. FA REPORTS AFT EMERGENCY EXIT LIGHTS + MID EMERG EXIT LIGHTS DO NOT ILLUMINATE DURING T/O BUT WORK ON LANDING -- CORRECTIVE ACTION --- AFTER TROUBLESHOOTING FOUND BATTERIES FOR EPSU WILL NOT HOLD A CHARGE. REPLACED BATTERIES OF THESDR F3LA2018100200448Drain Valve · leakingDISCREPANCY: REFERENCE LOG PAGE 1122908 ITEM 1, HYD RSVR LO LVL IN FLIGHT. CORRECTIVE ACTION: FOUND YELLOW RESERVOIR DRAIN VALVE LEAKING. REMOVED AND REPLACED VALVE. REFERENCE AMM 29-11-41-400-004A AND 29-11-41-000-004A. NO LEAKS NOTED RAN NR 2 ENGINE. NO LEAKSDR F3LA2018081300386Unknown · odorFUMES NOTED BY THE AFT CABIN CREW AS SWEATY ODOR, BRIEFLY ON TO AND MORE SIGNIFICANTLY ON LANDING. INSPECTED THE ACFT AND PERFORMED PACK BURNOUT. NO ODOR DETECTED. THE ACFT WAS OK TO CONTINUE. IAW TSM 05-50-00-810-831-A. HPC STAGES 1 & 2 BORESCOPES WERE SDR F3LA2017121800270Fan · seizedINFLIGHT EMERGENCY. SMOKE IN COCKPIT. STRONG ELECTRICAL ODOR. AIR TURN BACK. ODOR FOUND TO BE FROM AFT AVIONICS BAY BLOWER FAN. REMOVED AND REPLACED AVIONICS VENT BLOWER FAN (20HQ) IAW AMM 21-26-051-400-001-A. OPS CHECKED GOOD.SDR F3LA2013080100886Connector · backed outLOWER EMERGENCY EXIT LIGHT SIGN, ROW 11 ABC INOPERATIVE, 90WL3. RECONNECTED SPLICE CONNECTOR, OPS CHECK OK, REF AMM 33-51-16-PB 401.