Service difficulty reports · 14
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR EE4Y2023031017363Beam · noneDURING THE ALLEGIANT ENGINEERING ORDER NUMBER E53331-0006 REV. 03 DATED 08-07-2019 PARAGRAPH A, B, C ( NO DEFECT FOUND) AND ALLEGIANT ENGINEERING ORDER NUMBER 5331-007 REV. 03 DATED 10-24-2019 AS RELATED TO A.D. 2018-06-04. CORRECTIVE ACTION: SEE COOPESA WORK SDR WX0A2023010931691Battery Pack · inoperativeEMERGENCY EXIT LIGHT AT ROW 12 DEF INOP / REMOVED AND REPLACED 12 DEF EPSU BATTERY AND OPS CHECKED GOOD PER AMM 33-51-38-020-053-A."SDR WX0A2021031273661Button · false activationEVAC BUTTON LIGHT ON FA PANEL ILLUMINATED / PERFORMED CID 1 POWER UP TEST IAW A320 MM 23-73-00 AND TEST OF EVAC IAW A320 AMM 23-73-00-710-004A. OP TEST OK"SDR DU4R2020120900058Skin · dentedDURING SCHEDULED INSPECTION AT HAECO LAKE CITY, FL FOUND AFT CARGO BAGGAGE DOOR OUTER SKIN AT FWD LOWER CORNER OF DOOR HAS 4 EA DENTS. S/O 193115 N/R 22075.SDR DU4R2020120900057Skin · dentedDURING SCHEDULED INSPECTION AT HAECO, LAKE CITY, FL FOUND LT FUSELAGE SKIN FR 555+2, STR 29L HAS A DENT. S/O 1930115 N/R 22046.SDR WX0A2020032573492Battery · dischargedFLIGHT ATTENDANT JUMP SEAT FLASHLIGHT BATTERY DEAD. / REPLACED FLASHLIGHT BATTERIES"SDR WX0A219101473431Power Supply · no testEPSU 13WL FAILED DURING CABIN EMERGENCY LIGHTING TEST / R&R EPSU"SDR WX0A2019101473430Power Supply · no testEPSU 10WL FWD L FAILED DURING CABIN EMERGENCY LIGHTING / R&R EPSU"SDR WX0A2019101473429Power Supply · no testLT & RT OVERWING EPSU FAILED TO TEST. R & R THE EPSU.SDR WX0A201904263391Megaphone · inoperativeL1 MEGAPHONE INOP / R&R MEGAPHONE"SDR WX0A073199Battery Pack · inoperativeFA STATED THE EXIT ROW LIGHTING OVER THE RIGHT WING WAS NOT OPERATIVE. TROUBLESHOT IAW TSM 33-51-00-810-806A EPSU COMMUNICATION FAULT MESSAGE. FOUND FAULTY BATTERY AT 12WL EPSU.SDR WX0A2015060172619Unknown · odorECAM, SMOKE LAVATORY DET FAULT, POSTED WHILE TAXING OUT FOR TAKEOFF. FLIGHT ATTENDANTS REPORTED SMELLING BURNING SMELL FROM AFT RIGHT LAV. PERFORMED LAV A SMOKE DETECTOR TEST IAW 26-17-15, TESTED OK. NO DEFECTS NOTED IAW AMM 26-17-00-710-001-A. TROUBLE SHOSDR WX0A2015052772611Megaphone · inoperativeFORWARD FLIGHT ATTENDANT MEGA PHONE INOPERATIVE. R & R FWD FLIGHT ATTENDANT MEGA PHONE IAW AMM 25-65-51. OPERATIONS CHECKED GOOD.SDR WX0A071957Battery Pack · dischargedAFT FLIGHT ATTENDANT FLASHLIGHT INOPERATIVE. R & R BATTERY PACK FOR EMER FLASHLIGHT IAW AMM 25-65-00 CHECKED NORMAL.