Service difficulty reports · 9
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR WX0A2024031531979Actuator · faulted(EMERGENCY DECLARED) F/CTL FLAP FAULT. PERFORMED TSM 27-51-00-810-810-A OPERATED FLAPS AND FOUND NO POPPED TORQUE LIMITERS AT THIS TIME. DUE TO NO TORQUE LIMITER FOUND POPPED, REMOVED AND REPLACED FLAP ACTUATOR 1 (6255CM) REF AMM 27-54-49-000-001-A AND 27-SDR WX0A2023112731898Megaphone · unknownFWD MEGAPHONE BROKEN / REMOVED AND REPLACED THE FWD MEGAPHONE REF A320 LOPA EMERGENCY EQUIPMENT LAYOUT A2250006L03. OPS CHECK NORMAL."SDR WX0A2023110631882Megaphone · unknownFOUND LH AFT MEGAPHONE INOP. / REMOVED AND REPLACED MEGAPHONE IAW AMM 25-65-51-920-001-A. OPS CHECK GOOD."SDR WX0A2023040331745Unknown · unknownEMERGENCY EXIT LIGHTS IN CABIN TURNED ON PERIODICALLY THROUGHOUT THE FLIGHT. 3 OR 4 TIMES / PERFORMED TSM 33-51-00-810-819-A. SUSPECT BAD RELAY. REMOVED AND REPLACED RELAY PER ESPM 20-46-50. NO DEFECTS NOTED AT THIS TIME."SDR WX0A2023031731742Epsu · unknownEMERGENCY LIGHTS AND SIGNS AER INOP ON BATTERY POWER AT L2 AND R2 DOORS. / FOUND 13WL AT FAULT: REMOVED & REPLACED 13WL AND BITE TEST OK REF: AMM 33-51-38-000-001-A AND AMM 33-51-38-400-001-A: AMM 33-51-00-710-001 FOR BITE TEST."SDR WX0A2022021874005Megaphone · noneF/AS REPORT MEGAPHONE VOLUME KNOB DETACHED / REPLACED MEGAPHONE IAW AMM 25-65-51"SDR WX0A2022021473994None · noneTROUBLE SHOT DOOR FOUND LOWER AFT GRIT CLEARANCE F1 AND F2 OUT OF LIMITS ALSO FOUND 3 AFT LOWER DOOR STOP SCREWS OUT OF LIMITS / ADJUSTED 3 AFT LOWER STOP SCREWS TO .000 IAW AMM 52-13-00-820-001-A STEP 4. B. (11) THIS MADE F1 & F2 CLEARANCE ON GIRT BAR FITTINSDR WX0A2022011073922Light · false indicationCABIN EMERGENCY LIGHTING FLICKERS ON AND OFF DURING TAXI AND INFLIGHT / PERFORMED CABIN EMERGENCY LIGHTTING OPS CHECK AFTER RESET OF CIDS, LIGHTING CHECKED GOOD IAW AMM 33-51-00-710-008-A. MONITORED FOR 5 MINUTES NO FLICKERING NOTED. CIDS RESET IAW AMM 23-73-0SDR WX0A2021081873812Battery Pack · no testPERFORMED EMERGENCY LIGHT TEST AND FOUND RIGHT EPSU FAULTING AND FWD, AFT AND LEFT EPSU BATT FAULTING / REMOVED AND REPLACED RIGHT EPSU AND FWD, AFT AND LEFT EPSU BATT. OPS CHECKS GOOD IAW AMM 33-51-38"