N2743E, cancelled May 13, 2003

Service difficulty reports · 42

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N2743E' AND deregistration_id = 'N2743E-2003-05-13'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR HEEA065158Fuel Pump · failedNR 2 ENGINE SLOW TO START AFTER BEING SHUT DOWN FOR AN HOUR OR MORE.Nov 15, 1999 · N2743E · Skrsky S76A · Engine Fuel PumpSDR HEEA065153Damper · failedNO DAMPENING.Nov 15, 1999 · N2743E · Skrsky S76A · Main Rotor HeadSDR HEEA065095Fuel Pump · wornFUEL PUMP HAD WORN INTERNAL SPLINES.Nov 11, 1999 · N2743E · Skrsky S76A · Engine Fuel PumpSDR HEEA063061Dc Control · failedDC CONTROL COULD NOT RESET AFTER TEST.Aug 12, 1999 · N2743E · Skrsky S76A · DC Generating SystemSDR HEEA063047Indicator · inoperativeNR 2 NEEDLE INOPERATIVE ON HYDRAULIC PRESSURE INDICATOR.Aug 9, 1999 · N2743E · Skrsky S76A · Hydraulic Pressure IndicatorSDR HEEA062413Beacon · inoperativeBEACON INOPERATIVE.Jun 17, 1999 · N2743E · Skrsky S76A · Marker Beacon SystemSDR HEEA062412Actuator · malfunctionedACTUATOR CHATTERS AND KICKS.Jun 17, 1999 · N2743E · Skrsky S76A · Autopilot Main ServoSDR HEEA062411Generator · malfunctionedA.C. GENERATOR BEARING LIGHT CAME ON IN-FLIGHT. INSPECTED BY ACCESSORY OVERHAUL SHOP AND FOUND BEARINGS WERE ROUGH.Jun 17, 1999 · N2743E · Skrsky S76A · AC Generator-AlternatorSDR HEEA061628Gyro · malfunctionedNR 2 PITCH KICKS IN-FLIGHT.Apr 6, 1999 · N2743E · Skrsky S76A · Attitude and Direction Data SystemSDR HEEA0016789Relay · failedRELAY INSTALLED ON AIRCRAFT. FOUND TERMINALS 12 AND 13 AND TERMINALS 22 AND 23 HAD NO CONTINUITY IN REST POSITION. WHEN POWER IS APPLIED TO X1 AND X2, THEY HAVE CONTINUITY. FUNCTIONAL CHECKED RELAY AS RECEIVED. CONFIRMED PROBLEM. RELAY WAS INADVERTENTLY WNov 12, 1998 · N2743E · Skrsky S76A · DC Generating SystemSDR HEEA0016284Control Unit · failedDC CONTROL - GROUND FAULT WOULD NOT TEST.Oct 22, 1998 · N2743E · Skrsky S76A · DC Generating SystemSDR HEEA0016282Control Unit · failedDC CONTROL WOULD NOT TEST ON START-UP.Oct 22, 1998 · N2743E · Skrsky S76A · DC Generating SystemSDR HEEA0016253Oil Cooler · leakingOIL COOLER LEAKING.Oct 21, 1998 · N2743E · Skrsky S76A · Engine Oil CoolerSDR HEEA0016250Pump · leakingHYDRAULIC PUMP LEAKS FROM SEAL DRAIN.Oct 21, 1998 · N2743E · Skrsky S76A · Hydraulic Pump (Electric/Engine), MainSDR HEEA0016036Bearing · failedBEARING FAILURE, FOUND METAL SHAVING ON SEALS AND ROUGH ROTATION. REPLACED WITH SERVICEABLE BEARINGS.Sep 11, 1998 · N2743E · Skrsky S76A · Turbine SectionSDR HEEA0015948Potentiometer · malfunctionedCAUSED ACTUATOR TO BE INOPERATIVE. INSPECTED BY ACCESSORY OVERHAUL SHOP AND FOUND POTS CAUSED ACTUATOR TO TEST OUT OF LIMITS ON TEST POINTS 9(Q) 3 & 5 (MECHANICAL CENTER OUT OF LIMITS AFTER SETTING ELECTRICAL CENTER) AND STRIP CHART INDICATED BADAREAS IN NULLSep 3, 1998 · N2743E · Skrsky S76A · Electrical Power SystemSDR 98ZZZX3596Detector Loop · failedSHORTLY AFTER TAKEOFF, NR 1 ENGINE FIRE LIGHT ILLUMINATED. PILOT DEPLOYED FIRE BOTTLE AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND DEFECTIVE FLAME DETECTOR. REF: S-76 IPC, CHAPTER 26-11-00, FIGURE 1, ITEM 21.Aug 24, 1998 · N2743E · Skrsky S76A · Fire DetectionSDR HEEA0015584Amplifier · failedNR 1 TORQUE INTERMITTENTLY STICKS WHEN PULLING POWER.Aug 14, 1998 · N2743E · Skrsky S76A · Engine ControlsSDR HEEA0014668Tip Cap · brokenMAIN ROTOR TIP CAP OUTER DOUBLER SEPARATED WITH FIBERGLASS BROKEN BETWEEN THE DOUBLER.Jun 9, 1998 · N2743E · Skrsky S76A · Main Rotor BladesSDR HEEA0010191Generator · failedA/C GEN LIGHT CAME ON IN FLIGHT AND WOULD NOT RESET.Jun 19, 1997 · N2743E · Skrsky S76A · AC Generator-AlternatorSDR HAIHEEA9729Generator · failedA/C GENERATOR WOULD NOT COME ON LINE.Apr 30, 1997 · N2743E · Skrsky S76A · AC Generation SystemSDR HAIHEEA9581Gyro · precessesPILOTS ADI PRECESSES.Apr 24, 1997 · N2743E · Skrsky S76A · Attitude Gyro and Indicating SystemSDR HAIHEEA9296Afcs Control · fail testAFCS CONTROL PANEL FAILED CONTINUITY TEST IN MAINT. MANUAL.Apr 1, 1997 · N2743E · Skrsky S76A · Auto Flight SystemSDR HEEA979124Receiver · errorsPROVIDING HAZARDOUSLY MISLEADING INFORMATION TO THE FLIGHT CREW IS A MAJOR FAILURE CONDITION FOR THE AIRCRAFT. SINGLE LATENT FAILURES OF CDI DEVIATION OUTPUT WIRES (OPEN) RESULT IN A NON-FLAGGED AND CENTERED DEVIATION BAR, INDICATING AN ON-COURSELOCALIZER OR Feb 19, 1997 · N2743E · Skrsky S76A · Localizer/VOR SystemSDR HEEA979123Receiver · errorsPROVIDING HAZARDOUSLY MISLEADING INFORMATION TO THE FLIGHT CREW IS A MAJOR FAILURE CONDITION FOR THE AIRCRAFT. SINGLE LATENT FAILURES OF CDI DEVIATION OUTPUT WIRES (SHORTED AND/OR OPEN) RESULT IN A NON-FLAGGED AND CENTERED DEVIATION BAR, INDICATINGAN ON-COURSFeb 19, 1997 · N2743E · Skrsky S76A · Localizer/VOR SystemSDR HEEA968807Heat Exchanger · weld leaksHEAT EXCHANGER LEAKS AT WELD ALONG OUTER B-NUTLINE.Dec 30, 1996 · N2743E · Skrsky S76A · Engine Fuel/Oil CoolerSDR HEEA968019Generator · failedA/C BEARING LIGHT CAME ON IN FLIGHT.Oct 3, 1996 · N2743E · Skrsky S76A · AC Generator-AlternatorSDR HEEA967773Floor Panel · mis mfgNEW FLOOR DOES NOT HAVE PROPER JOGGLE ON INBOARD AND FORWARD EDGES OF PANEL AS NEEDED TO GO BELOW (-051) LARGE FLOOR.Sep 3, 1996 · N2743E · Skrsky S76A · Fuselage Floor PanelSDR HEEA967772Floor Panel · mis repairedFLOOR PANEL WAS REPAIRED AND EXISTING INSERTS IN FLOOR PANEL WERE LEFT INSIDE OLD CORE MATERIAL AND NEW TOP SKINS WERE INSTALLED. THE OLD INSERTS INSIDE PANEL MAKE IT IMPOSSIBLE TO INSTALL NEW STYLE INSERTS THAT MUST GO THROUGH TOP ANDBOTTOM SKINS. SENT TO Sep 3, 1996 · N2743E · Skrsky S76A · Fuselage Floor PanelSDR HEEA967771Floor Panel · mis repairedFLOOR PANEL WAS REPAIRED AND EXISTING INSERTS IN FLOOR PANEL WERE LEFT INSIDE OLD CORE MATERIAL AND NEW SKINS WERE INSTALLED. THE OLD INSERTS INSIDE THE PANEL MAKE IT IMPOSSIBLE TO INSTALL NEW STYLE INSERTS THAT MUST GO THROUGH TOP ANDBOTTOM SKINS. TIME SINSep 3, 1996 · N2743E · Skrsky S76A · Fuselage Floor PanelSDR HEEA967734Tip Cap · defectiveTIP CAP HAS FIBERGLASS BROKEN BETWEEN INNER DOUBLER AND OUTER DOUBLER ON THE UPPER SURFACE.Aug 30, 1996 · N2743E · Skrsky S76A · Main Rotor BladesSDR HEEA967660Tip Cap · tearINSPECTED BOTTOM SIDE ON M/R BLUE BLADE TIP CAP AND FOUND TEAR ON TIP CAP. SUSPECT AIR BUBBLE IN PAINT MATERIAL CAUSING TEAR. AIR BUBBLE IS NOTABLE.Aug 16, 1996 · N2743E · Skrsky S76A · Main Rotor BladesSDR HEEA967015Blade · erodedPART IS ERODED. (EROSION THROUGH THE LEADING EDGE ABRASION STRIP ON PADDLE "B")Apr 17, 1996 · N2743E · Skrsky S76A · Tail Rotor BladesSDR HEEA967014Blade · erodedPART IS ERODED. (LEADING EDGE ABRASION STRIP HAS EROSION HOLE THROUGH THE STRIP.Apr 17, 1996 · N2743E · Skrsky S76A · Tail Rotor BladesSDR HEEA966357Blade · crackedPART IS CRACKED. SPAR CRACK AT THE TIP. THE CRACK STARTED FROM THE OUTER HOLE FOR THE "C" BLOCK BOLT. SCRAPPED M/R BLADE.Jan 4, 1996 · N2743E · Skrsky S76A · Main Rotor BladesSDR HEEA956243Actuator · defectiveAFCS ACTUATOR HAS BAD POTS AND EXCESSIVE SHAFT END PLAY.Dec 13, 1995 · N2743E · Skrsky S76A · Autopilot SystemSDR HEEA955855Module · defectiveDURING OPS CHECK, NOTED ROTOR BRAKE MOTOR SOUNDED WEAK BUT SEEMED TO OPERATE NORMALLY. TWO DAYS LATER AIRCRAFT WAS FLOWN FOR FIRST TIME AND PILOT'S REPORTED ROTOR BRAKE DOES NOT WORK. REPLACED WITH SERVICEABLE ROTOR BRAKE MODULE.Oct 5, 1995 · N2743E · Skrsky S76A · Main Rotor BrakeSDR HEEA955853Control Unit · defectiveCONTROL UNIT VOLUME CONTROL WORKS EITHER FULL VOLUME OR OFF. NO CONTROLLING VOLUME. REPLACED R1/S5 VOLUME SWITCH. REPAIRED. FOUND THUMBWHEEL TO INTERMITTENTLY DIAL WRONG FREQUENCIES. REPLACED S1 THUMBWHEEL. REPAIRED.Oct 5, 1995 · N2743E · Skrsky S76A · VHF Communications SystemSDR HEEA955370Loran · defectiveLIGHTS WILL NOT DIM. SENT TO ARNAV SYSTEMS FOR INSPECTION AND REPAIR.Jul 20, 1995 · N2743E · Skrsky S76A · Long-Range Navigation (LORAN) SystemSDR HEEA955118Nozzle · defectiveRECEIVING INSPECTION OF NEW, NEVER INSTALLED 2ND STAGE NOZZLE INDICATES .009" RUNOUT IN BOTH TIP PATHS, DIAPHRAGM OFF CENTER. NOTE: DAMAGE TO KEYS AND TANGS BY ADJUSTMENT PRIOR TO RECEIPT BY PHI. INSTALLED NEW 2ND STAGE NOZZLE.Jun 2, 1995 · N2743E · Skrsky S76A · Turbine SectionSDR HEEA954446Transceiver · inoperativeWOULD NOT RECEIVE.Mar 1, 1995 · N2743E · Skrsky S76A · VHF Communications SystemSDR HEEA954335Transceiver · malfunctionUNIT SHUTS DOWN DURING WARM UP PERIOD.Feb 10, 1995 · N2743E · Skrsky S76A · Weather Radar System
Back to N2743E, cancelled May 13, 2003