Service difficulty reports · 41
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR SIMA200228202Indicator · malfunctionedCREW REPORTED TO OPERATIONS THAT THEY SMELLED A STRONG ELECTRICAL SMOKE SMELL WITH THE AVIONICS FAN ON. MAINTENANCE REMOVED AND REPLACED THE STANDBY ADI IAW MM. OPERATIONAL CHECK WAS GOOD AND AIRCRAFT WAS RETURNED TO SERVICE.SDR SIMA200208101Battery · dischargedSAN - FLT 3360 - CREW REPORTED THAT ALL EMERGENCY LIGHTS WOULD NOT TEST. CONTRACT MAINTENANCE INSPECTED AIRCRAFT WHICH WAS THEN FERRIED TO SFP FOR REPAIR. MAINTENANCE REMOVED AND REPLACED ALL EMERGENCY LIGHT POWER SUPPLY UNITS (S/N 17381, 18335, 17649, 19522SDR SIMA200113111Bushing · corrodedSBP - DURING MBV MAINTENANCE, FOUND THE RIGHT MAIN LANDING GEAR INBOARD CONNECTING LINK AFT BUSHING IS CORRODED. REMOVED AND REPLACED BUSHING IAW SAAB AMM 57-40-05. (M)
See all 41 reports