N2811W, cancelled Feb 1, 2000
Service difficulty reports · 35
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N2811W' AND deregistration_id = 'N2811W-2000-02-01' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N2811W' AND deregistration_id = 'N2811W-2000-02-01' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DL72W992766Rib · crackedNR 12 RIB CRACKED. REPAIRED RIB PER M/M 57-54-0 FIG 804.SDR DL72W992765Rib · crackedNR 11 RIB CRACKED. REPAIRED PER M/M 57-54-0 FIG 804.SDR DL72W991858Smoke Light · illuminatedLAV SMOKE LIGHT ILLUMINATED. LAVS CHECKED AND NO SMOKE/FIRE/FUMES OBSERVED. POM PROCEDURES FOLLOWED AND LIGHT AND CABIN CHIMES EXTINGUISHED WHEN SWITCH IN STARBOARD AFT LAV WAS PLACED OFF. VERIFIED LAV SMOKE DETECTORS IN ALL LAVS CHECK NORMAL. NO SIGNS OF SDR DL72W991856Fan · failedON DESCENT INTO PHL, FLT ATTENDANTS REPORTED SMOKE IN CABIN. POM PROCEDURES FOLLOWED BUT WERE UNABLE TO DETERMINE SOURCE. FLT ATTENDANTS LATER REPORTED, SUSPECTED AN ELECTRICAL PROBLEM. TROUBLESHOT PACK SYSTEM AND ALL NORMAL. FOUND GASPER FAN POPPING C/B ASDR DL72W991680Bracket · crackedFOUND ON F-1 LETTER CK, NR 5 L/E FLAP ACTUATOR MOUNT BRACKET CRACKED OUTBOARD END. REPAIRED PER MM 57-20-0.SDR DL72W991609Bulb · failedEMERGENCY LIGHT INOP LOCATED ON EXTERIOR OW BETWEEN RT EMERGENCY ESCAPE HATCHES. RELAMPED SAME, CHECKS GOOD.SDR DL72W990543Skin · crackedLFEC INSPECTION OF THE STRINGER 26R SKIN LAP SPLICE BETWEEN FS 360 AND 681 REVEALED A CRACK IN THE LOWER FASTENER ROW OF THE LOWER SKIN. HFEC INSPECTION CONFIRMED TWO CRACKS/CORROSION AT FS 505. THE SKIN WAS CUTOUT WITH A 2 X 1 CUTOUT IN THE LAPSDR DL72W990139Engine · failedNR 2 ENGINE OIL PRESSURE INDICATION WENT TO 100 PSI. ON ENGINE SHUTDOWN, INDICATION WENT TO 60 PSI. ALL OTHER ENGINE INDICATIONS NORMAL WHEN ENGINE RUNNING. SHUTDOWN ENGINE PER POM, REPLACED ENGINE.SDR DL72W981260Slide · inoperative2R PASSENGER DOOR SLIDE PRESSURE LOW. REPLACED SLIDE ASSY.SDR DL72W981066Skin · corrodedTHE SKIN AROUND THE FWD LAV PAN WAS FOUND CORRODED AROUND THE AFT LWR CORNER OF THE CUTOUT. REPAIRED PER ERA 331722-14.SDR DL72W981065Bulkhead Web · crackedCRACKS WERE DISCOVERED IN THE FS 178 BLKHD WEB AT WL 200 ANDLBL 5.8. REPAIRED PER ERA 331668-14.SDR DL72W981012Brace · crackedDRAG BRACE SUPPORT ANGLE WAS FOUND DAMAGED AT APPROX BL 0. REPAIRED PER ERA 331714-14.SDR DL72W981011Frame · crackedFS 784 LT OVERWING EXIT FRAME WAS FOUND CRACKED IN THE OUTBD CHORD AT THE LWR EDGE. REPAIRED PER ERA 331643-14AD.SDR DL72W980972Fairing · crackedANGLE OUT AT STA 957 LT SIDE OF FUSELAGE OVER STA 18A. FAIRING ATTACH WEB CRACKED REF EO 4-60175-3. STARTED FABRICATING REPAIR AS PER M/M 53-12-0 FIG 1. FABRICATED REPAIR PER M/M 53-12-0. HEAT TREATED REPAIR PORTS PER PS 900-4-1 NR 1. OK TO INST SPLICE ANGSDR DL72W981016S-Duct · crackedNR 2 ENG INLET DUCT INTERNAL UPPER S-DUCT CRACKED AT 9 O'CLOCK AT STA 1151. BLENDED AREA AND DYE CHECKED AND TREATED AND PAINTED AREA, NO MORE CRACKS WERE FOUND. ALL WORK PERFORMED PER ERA 331669-14 OK PER PRI 331669-14.C/W ERA 33169-14.SDR DL72W981015S-Duct · crackedNR 2 ENG INLET DUCT INTERNAL TWO CRACKS AT 3 O'CLOCK AND 11 O'CLOCK AT STA 1151 DOGHOUSE SIDE. REMOVED DAMAGE PER SRM 54-10-3 FIG 13. FABRICATED DOUBLER AND FILLER PER SRM 54-10-3 FIG 13. DYE CHECKED AREA PER PS 900-6-3 NR 1. NO CRACKS FOUND. OK TO INSTALSDR DL72W980971Panel · damagedHORIZONTAL STABILIZER T/E LT SIDE HAS HOLE PUNCHED IN THE UPPER PANEL APPROX 10 INCHES INBD OF ELEVATOR POWERPACK CUTOUT. REMOVED DAMAGE WITH .375 DIA HOLE. DYE CHECKED, NO CRACKS FOUND. MANUFACTURED REPAIR PER SRM 55-10-3 FIG 3. INSTALLED REPAIR PER SRM 5SDR DL72W980970Floorbeam · corrodedFLOORBEAM CORRODED STA 344 BL 0. REMOVED CORROSION PER SRM 51-10-3. OUT OF LIMITS PER SRM 53-10-1 FIG 4. REMOVED ANGLE SUPPORTS, STARTED MANUFACTURING NEW SUPPORT. BEGAN REMOVAL OF T-CAP. COMPLETED REMOVAL OF T-CAP. DRILLED UP NEW T-CAP, EXCEPT TOP OF SSDR DL72W980973Bracket · crackedBRACKET CRACKED NR 1 KRUEGER ACTUATOR SUPPORT BRACKET AT I/B LOWER CORNER. REMOVED FASTENERS TO FACILITATE DOUBLER AND STOP DRILLED CRACK PER M/M 57-20-21 PG 811. FABRICATED DOUBLER PER M/M 57-20-21 PG 811. INSTALLED DOUBLER PER MM 57-20-21 FIG 807.SDR DL72W972353Skin · corrodedTHE FUSELAGE SKIN LAP SPLICE AT STR 26L WAS FOUND WITH SEVERAL AREAS OF CORROSION AND SEVERAL EXISTING SRM REPAIRS. THE SECTION OF SKIN BETWEEN STA 480 TO 680 AND S24L TO 27L WAS REMOVED AND A NEW SECTION OF SKIN SPLICED IN PER ER/A 363125-14, REV B.SDR DL72W972106Skin · crackedDURING VISUAL INSPECTION, TPA MTC FOUND THREE CRACKS EMANATING FROM THE LAP JOINT BOLT HOLES. THESE CRACKS ARE .125, .25 AND .25 IN LENGTH. ALL CRACKS ARE CONFINED TO STA 594, STR 26L. THE REPAIR WILL CONSIST OF STANDARD SRM REPAIR PROCEDURES PER SRM 53-30-SDR DL72W971970Stringer · crackedVERT STAB STR 9L IS CRACKED AT FIN STA 133.800. REPAIRED PER M/M 55-30-0.SDR DL72W971969Skin · crackedFOUND DURING D2 LETTER CHECK, .5 INCH CRACK RT ELEVATOR LOWER SKIN FWD OF ACCESS PANEL 9414. REPAIRED PER SRM 55-20-3.SDR DL72W971968Stringer · crackedFOUND DURING D2 LETTER CHECK, VERT STAB STR 9L CRACKED AT FIN STA 133.800. REPAIRED PER M/M 55-30-0.SDR DL72W971212Batteries · dischargedAFT EMERG EXIT LIGHT IN AIRSTAIR WILL NOT TEST. REPLACED BATTERIES, OPN CKS OK.SDR DL72W961459Skin · crackedTHE SKIN JUST BELOW FWD LAV SERVICE PANEL WAS FOUND CRACKED. THE SKIN IS MADE FROM 0.040 2024-T3 AND THE_FINAL CUTOUT DIMENSIONS WERE 1.375 FWD/AFT AND 2.5 ABOVE/BELOW. THIS ERA GIVES INSTRUCTIONS TO REPAIR THE DAMAGE WITH A 0.050 2024-T3 DOUBLER.SDR DL72W961314Relay · failedEMERGENCY EXIT LIGHTS WILL NOT GO OUT AFTER TEST. REPLACED R-70 RELAY AND SYSTEM TEST CHECKED NORMAL (P/N 244201154) (MFG 10-60450-3). EVENT OCCURED ON THE GROUND AFTER FLT 1739 ARRIVED FROM TUS\AND THE CREW NOTICED THAT THE EXIT LIGHTS WERE ON AFTER TESTINGSDR DL72W961020Blkhd Web · crackedTHE STA 1183 BULKHEAD WEB WAS FOUND CRACKED IN TWO LOCATIONS. THE DAMAGE WAS TRIMMED OUT WITH DIMENSIONS OF 2.6250 INCH AT LBL 8, WL 190 AND 8 INCH BY 3.1250 INCH AT LBL 14, WL 173. THE BULKHEAD WEB IS MANUFACTURED FROM 0.050 INCH CLAD 2024-T3. THIS ER/A AUSDR DL72W960938Floor Beam · corrodedFOUND ON MV1 CHECK - CORROSION ON FLOOR BEAM TOP SURFACE STA 1050 FROM RBL 10 TO 14. REPAIR - REPAIRED PER M/M 53-20-11.SDR DL72W960535Light · inoperativeCOCKPIT EMERGENCY LIGHT INOPERATIVE. REPLACED LIGHT ASSY. OPS CHECKS GOOD.SDR DL72W960092Angle · crackedDURING C-1 LETTER CHECK, FOUND .5 INCH CRACK AT NR 2 L/E SLAT COVE SKIN ATTACH ANGLE BELOW I/B UPSTOP PAD. REPAIRED PER M/M 57-54-0.SDR DL72W953401Sensor · failedLANDING GEAR FAILED TO RETRACT ALL HYD SYS NML - REPLACED FAULTY M831 SENSOR AND DAMAGED WIRES AT SAME SENSOR. OPERATION NORMAL.SDR DL72W952513Skin · cracked.3750 INCH CRACK, NR 3 AFT FLAP UPPER SURFACE AFT OF 2ND FROM O/B LOWER ROLLER TRACK CUTOUT. FOUND AT B-2 LTR CK. REPAIRED PER SRM 57-50-4.SDR DL72W952512Web · crackedNR 6 SLAT O/B ACT ROD END WEB CRACKED AFT SIDE. FOUND AT B-2 LTR CK. REPAIRED PER SRM 57-54-0.SDR DL72W952511Angle · crackedNR 2 SLAT I/B STOP PAD LWR ATTACH ANGLE IS CRACKED. FOUND AT B-2 LTR CK. REPAIRED PER MM 57-54-0.