N286SC, cancelled Jan 3, 2018
Service difficulty reports · 198
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N286SC' AND deregistration_id = 'N286SC-2018-01-03' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N286SC' AND deregistration_id = 'N286SC-2018-01-03' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA98722Seat Track · corrodedDURING A HEAVY MAINT CHECK, CORROSION WAS FOUND ON SEAT TRACK BETWEEN STATIONS 1050 AND 1070 RBL 46 IN CABIN FLOOR STRUCTURE. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM B727 531001. REMOVED SEAT TRACK IAW SRM B727 513002. FABRICATED NEW SEAT TRACK IAW SRM SDR SCNA98721Seat Track · corrodedDURING A HEAVY MAINT CHECK, CORROSION WAS FOUND ON SEAT TRACK AT STATION 1070 RBL 24 IN CABIN FLOOR STRUCTURE. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM B727 531001. REMOVED SEAT TRACK IAW SRM B727 513002. FABRICATED NEW SEAT TRACK IAW SRM B727 531003. TSDR SCNA98720Angle · corrodedDURING A HEAVY MAINT CHECK, CORROSION WAS FOUND ON FLOOR SUPPORT ANGLE BETWEEN STATIONS 1050 AND 1070 LBL 27 ON CABIN FLOOR STRUCTURE. REMOVED CORROSION FROM SUPPORT ANGLE IAW B727 SRM 511001. CORROSION WAS FOUND TO BE OUT OF LIMITS IAW B727 SRM 531001. FABSDR SCNA98719Angle · corrodedDURING A HEAVY MAINT CHECK, CORROSION WAS FOUND ON SEAT TRACK SUPPORT ANGLE BETWEEN STATIONS 1050 AND 1070 RBL 20 IN CABIN FLOOR STRUCTURE. REMOVED CORROSION FROM SUPPORT ANGLE IAW B727 SRM 511001. CORROSION FOUND TO BE OUT OF LIMITS IAW B727 SRM 531001. FSDR SCNA98718Angle · corrodedDURING A HEAVY MAINT CHECK, CORROSION WAS FOUND ON SEAT TRACK SUPPORT ANGLE BETWEEN STATIONS 1030 AND 1050 RBL 44 IN CABIN FLOOR STRUCTURE. REMOVED CORROSION FROM SUPPORT ANGLE IAW B727 SRM 511006. CORROSION FOUND TO BE OUT OF LIMITS IAW B727 SRM 531001. FSDR SCNA98717Angle · corrodedDURING A HEAVY MAINT CHECK, CORROSION WAS FOUND ON FLOOR SUPPORT ANGLE BETWEEN STATIONS 1030 AND 1050 RBL 24 IN CABIN FLOOR STRUCTURE. REMOVED CORROSION FROM SUPPORT ANGLE IAW B727 SRM 511001. CORROSION FOUND TO BE OUT OF LIMITS IAW B727 SRM 531001. FABRICASDR SCNA98716Seat Track · corrodedDURING A HEAVY MAINT CHECK, CORROSION WAS FOUND ON SEAT TRACK BETWEEN STATIONS 1030 AND 1050 RBL 56 IN CABIN FLOOR STRUCTURE. CORROSION WAS FOUND TO BE OUT OF LIMITS IAW SRM B727 531001. REMOVED SEAT TRACK IAW SRM B727 513002. FABRICATED NEW SEAT TRACK IAW SDR SCNA98093Battery Pack · dischargedDURING A LINE MAINTENANCE CHECK, THE EMERGENCY EVACUATION SLIDE LIGHTS WERE FOUND TO BE INOPERATIVE AT DOOR L1 AND R1. REMOVED AND REPLACED THE BATTERY PACK FOR THE EVACUATION SLIDE LIGHTS AT DOORS L1 AND R1.SDR SCNA98092Battery Pack · dischargedDURING A LINE MAINTENANCE CHECK, THE EMERGENCY EVACUATION SLIDE LIGHTS WERE FOUND TO BE INOPERATIVE AT DOOR L2 AND R2. REMOVED AND REPLACED THE BATTERY PACK FOR THE EVACUATION SLIDE LIGHTS AT DOORS L2 AND R2.SDR SCNA98090Line · rupturedAFTER DEPARTURE LOSS OF A SYSTEM HYDRAULIC QUANTITY UPON GEAR RETRACTION. PERFORMED ALL COM PROCEDURES AND DUMPED FUEL. RETURNED TO MSP. FOUND RUPTURED LINE ON ELEVATOR ACCESSORY. REMOVED AND REPLACED LINE WITH FOLLOWING LEAK AND OPERATIONAL CHECKS GOOD.SDR SCNA98013Keel Beam · crackedDURING A SCHEDULED MAINTENANCE CHECK, A CRACK WAS LOCATED ON THE VERTICAL KEEL BEAM CHORD AT BS 870, APPROXIMATE RBL 3.5. DURING REMOVAL AND REPLACEMENT OF THE CRACKED CHORD NO ADJACENT STRUCTURE WAS FOUND DAMAGED.SDR SCNA98009Strap · out of positionAIR RETURN DUE TO DOOR STRAP NOISE FROM DOOR 2R. REMOVED DOOR STRAP FROM DOOR AND INSPECTED DOOR SKIN AND NR 3 ENGINE C1 AND C2 DISCS FOR DAMAGE. NO DAMAGE FOUND AND OPS CHECK OK.SDR SCNA97355Support · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND THE FLOOR SUPPORT CHANNEL AT STATION 344, RBL 50 - 62.5 CORRODED OUT OF LIMITS. REMOVED, FABRICATED, AND INSTALLED NEW CHANNEL IAW SRM 51-30-2, 51-20-2, 51-10-1 AND DRAWING 65-26173.SDR SCNA97360Floorbeam · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND THE FLOORBEAM UPPER CAP CORRODED BEYOND LIMITS AT STATION 344, RBL 68 - LBL 52. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT CAP IAW SRM 51-10-1, AND 51-10-2.SDR SCNA97358Seat Track · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND THE SEAT TRACK AT STATION 344-360, LBL 22 CORRODED BEYOND LIMITS. REMOVED AND REPLACED CORRODED SECTION OF SEAT TRACK IAW SRM 51-30-2, 53-10-5, AND 51-10-2.SDR SCNA97357Seat Track · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND THE SEAT TRACK AT STATION 344-380, RBL 44 CORRODED BEYOND LIMITS. REMOVED AND REPLACED CORRODED SECTION OF SEAT TRACK IAW SRM 51-30-2.SDR SCNA97359Support · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND FLOORBOARD SUPPORT CHANNEL IN THE AFT CARGO PIT DENTED AND PUNCTURED FROM STATION 950E TO 990. REMOVED, FABRICATED AND INSTALLED NEW SUPPORT CHANNEL IAW SRM 53-10-2 AND 51-30-01.SDR SCNA97356Support · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND THE FLOORBOARD SUPPORT CHANNEL IN THE AFT CARGO PIT DENTED AT STATION 950F, RBL 11. REMOVED, FABRICATED, AND INSTALLED NEW FLOOR SUPPORT IAW SRM 51-30-02, 53-10-2, AND 51-30-2.SDR SCNA97293Power Supply · inoperativeTHE L-2 DOOR OVERHEAD EMERGENCY EXIT SIGN WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT POWER SUPPLY AND BATTERY PACK, OPS CHECKED NORMAL PER B727 MAINTENANCE MANUAL 33-50-01.SDR SCNA97283Battery Pack · dischargedTHE EMERGENCY LIGHT AT DOOR 2L WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED BATTERY PACK, LIGHT TESTED GOOD.SDR SCNA97273Batteries · dischargedTHE L-2 DOOR EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED BATTERIES, LIGHT OPS CHECKED NORMAL.SDR SCNA97194Lamp · failedTHE AFT AIRSTAIR OVERHEAD EMERGENCY LIGHT WAS FOUND INOPERATIVE. RELAMPED LIGHT, LIGHT TESTED GOOD.SDR SCNA97125Battery Pack · dischargedTHE L-2 DOOR FIXED EXIT SIGN AND AREA LIGHT INOPERATIVE. REMOVED AND REPLACED BATTERY PACK, LIGHT OPS CHECKED GOOD.SDR SCNA96438Connector · looseALL THREE LAV SMOKE DETECTORS FAILED TO TEST. RECONNECTED CANNON PLUGS IN ACCORDANCE WITH 20-60-06, ALL OPS CHECKED GOOD.SDR SCNA96428Lamp · inoperativeFOUND RIGHT AFT SERVICE DOOR EMERGENCY LIGHT INOP. CLEANED SOCKET, RELAMPED FIXTURE AND OPS CHECKED GOOD.SDR SCNA96431Switch Wire · failedON RETRACTION, NOSE GEAR DISAGREE LIGHT REMAINED ON WITH ALL OTHER INDICATIONS NORMAL. LIGHT EXTINGUISHED WHEN GEAR CYCLED DOWN. FOUND WIRE-C BROKEN AT S96 NOSE LANDING GEAR LOCK SWITCH. REPAIRED WIRE, OPS CHECKED GOOD IN ACCORDANCE WITH 32-60-2.SDR SCNA96401Batteries · dischargedFOUND CEILING MOUNTED EMERGENCY AREA LIGHT IN FORWARD CABIN INOP. REMOVED AND REPLACED BATTERIES FOR AREA LIGHT IN ACCORDANCE WITH MM 33-50-81 AND OPS CHECKED NORMAL.SDR SCNA96380Light · inoperativeTHE AFT AIRSTAIR EMERGENCY EXIT AREA LIGHT WAS FOUND FLICKERING AND DIM. REMOVED AND REPLACED AFT AIRSTAIR LIGHT ASSEMBLY. PERFORMED OPS CHECK, NEW LIGHT OPS CHECKED GOOD.SDR SCNA96316Power Supply · inoperativeFOUND L2 OVERHEAD EMERGENCY EXIT LIGHT INOP. REMOVED AND REPLACED THE POWER SUPPLY (P/N 9005-42), (S/N 19440) AND THE BATTERY PACK (P/N 9008-3-5A), (S/N 10000), OPS CHECKED NORMAL.SDR SCNA96267Battery · dischargedFOUND AFT AIRSTAIR EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERIES AND OPS CHECKED GOOD.SDR SCNA96252Lamp · failedFOUND RIGHT FORWARD OVERWING EMERGENCY EXIT LIGHT INOP ON LINE CHECK. REMOVED AND REPLACED RIGHT OVERWING EMERGENCY LIGHT LAMP. EMERGENCY LIGHTS OPS CHECK GOOD.SDR SCNA96251Battery Pack · dischargedFOUND RIGHT OVERWING EMERGENCY EXIT LIGHTS INOP ON LINE CHECK. REMOVED AND REPLACED RIGHT OVERWING BATTERY PACK. EMERGENCY LIGHTS OPS CHECK GOOD.SDR SCNA96198Lamp · inoperativeFOUND EMERGENCY LIGHTS DISARM AMBER LIGHT INOP. REMOVED AND REPLACED LAMP, OPS CHECK GOOD.SDR SCNA96015Smoke Detector · inoperativeTHE AFT LEFT LAVATORY SMOKE DETECTOR WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED SMOKE DETECTOR AND UNIT CHECKED GOOD.SDR SCNA95289Battery Pack · dischargedTHE AFT AIRSTAIR EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. REPLACED BATTERIES IN AFT AIRSTAIR EMERGENCY EXIT LIGHT AND LIGHT CHECKED GOOD.SDR SCNA95282Angle · crackedDURING HEAVY MAINTENANCE VISIT, FOUND AFT CARGO SUPPORT ANGLE CRACKED AT STATION 1010, STRINGERS 26L TO 28L. FABRICATED AND INSTALLED REPAIR ANGLE IAW B727 SRM 53-10-04.SDR SCNA95267Fire Connector · looseDURING EN ROUTE CLIMB, THE NUMBER 1 ENGINE FIRE DETECTION LIGHT FLICKERED ON AND OFF. FOUND FIRE LOOP CONNECTOR D1926 CERAMIC INSULATION DAMAGED, REPLACED CONNECTOR. INSPECTED LOOPS AND ATTACHING WIRING AND FOUND NO OTHER DISCREPANCIES. PERFORMED SYSTEM TESTSDR SCNA95266Fire Wire · out of positionDURING EN ROUTE CLIMB, THE NUMBER 1 ENGINE FIRE DETECTION LIGHT FLICKERED ON AND OFF, LASTED A FEW SECONDS THEN WENT OFF AND STAYED OFF. ALL ENGINE INDICATIONS READ NORMAL. FOUND FORWARD PLUG CONNECTOR STRAIN RELIEF RUBBING WIRE. REROUTED WIRING FOR BETTER SDR SCNA95256Fire Loop · oil cakedTHE NUMBER 1 ENGINE FIRE WARNING LIGHT ILLUMINATED AND BELL RANG DURING GROUND OPERATIONS. ALL ENGINE INDICATIONS WERE NORMAL. THE ENGINE WAS SHUTDOWN. DURING INSPECTION TWO CONNECTORS FOR FIRE LOOP IN STUB WING WERE FOUND OIL CAKED CAUSING FALSE FIRE INDICSDR SCNA95245Drive Motor · leakingDURING CLIMBOUT AT 13,000 FEET, THE NUMBER 1 A-SYSTEM HYDRAULIC PUMP \LO PRESS\ LIGHT ILLUMINATED AND THE A-SYSTEM QUANTITY DROPPED RAPIDLY. THE OUTBOARD FLAP DRIVE MOTOR SEAL WAS FOUND BLOWN OUT. REMOVED AND REPLACED THE MOTOR PER MM 27-57-62.SDR SCNA95163Flap Drive Motor · leakingAFTER ENGINE START AND TAXI THE A-SYSTEM HYDRAULIC QUANTITY DROPPED FROM FULL TO 2 GALLONS. THE OUTBOARD FLAP DRIVE MOTOR WAS FOUND LEAKING WITH THE ENGINES RUNNING AND FLAPS IN THE DOWN POSITION. REMOVED AND REPLACED THE FLAP DRIVE MOTOR PER MM 27-51-62. OSDR SCNA95159Oil Press Switch · leakingWHILE EN ROUTE THE NR 3 ENGINE OIL QUANTITY BEGAN TO DECREASE. THE ENGINE WAS SHUTDOWN, AND ALL INDICATIONS WERE NORMAL. A LEAK WAS FOUND AT THE LOW OIL PRESSURE SWITCH AND THE UNION BELOW THE SWITCH. THE SWITCH AND PACKINGS AT THE UNION WERE REPLACED, AND SDR SCNA95147Eel Lamp · failedFOUND THE L-2 EMERGENCY SLIDE LIGHT INOPERATIVE. RELAMPED THE L-2 DOOR EMERGENCY SLIDE LIGHT. OPS CHECKED GOOD.SDR SCNA95140Apu · failedWHILE AIRCRAFT WAS TAXIING, THE CABIN FILLED WITH SMOKE. MAINTENANCE FOUND THE APU INTERNALLY FAILED CAUSING SMOKE, IT WAS THEN INTRODUCED INTO THE CABIN THOUGH THE AIRCRAFT PACKS. THE APU WAS REMOVED AND REPLACED AND OPERATIONS CHECKED NORMAL.SDR SCNA95060Control Cable · out of adjNOSE GEAR DOOR LIGHT ON WITH GEAR DOOR CLOSED. FOUND FORWARD NOSE GEAR DOORS CABLE BELOW TENSION LIMITS. ADJUSTED GEAR DOORS CABLE PER 32-22-01, PAGE 501. OPS CHECK GOOD.SDR SCNA95048Warning Switch · intermittentNOSE GEAR DOOR LIGHT STAYED ON AFTER TAKEOFF. DUMPED 17, 500 LBS OF FUEL AND RETURNED TO ORD. FOUND INTERMITTENT NOSE GEAR DOOR WARNING SWITCH. REMOVED AND REPLACED NOSE GEAR DOOR WARNING SWITCHES. GEAR DOOR WARNING SYSTEM OPS CHECK GOOD IAW 727 MM 32-62-1SDR SCNA95024Eel Power Pack · failedMSP - DURING LINE CHECK FOUND AFT AIRSTAIR EMERGENCY OVERHEAD LIGHT INOPERATIVE. REMOVED AND REPLACED AFT AIRSTAIR EMERGENCY LIGHT POWER PACK, IAW MM 33-50-61 AND OPS CHECKED GOOD. (W)SDR SCNA95009Eel Batteries · dischargedMSP - AFT AIRSTAIR OVERHEAD EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT BATTERIES. OPERATIONAL CHECK PER B727 MM 33-50-00. (W)
Back to N286SC, cancelled Jan 3, 2018