N310TZ, cancelled Jul 29, 2008
Service difficulty reports · 37
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N310TZ' AND deregistration_id = 'N310TZ-2008-07-29' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N310TZ' AND deregistration_id = 'N310TZ-2008-07-29' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AMTA200800230Charger · faultyISFD BATTERY FAULT LIGHT ON. REMOVED AND REPLACED ISFD BATTERY CHARGER OPS CHECK GOOD NO FAULT LIGHT. (K)SDR AMTA200800229Battery · unsecureISFD WENT BLANK WITH NOSE WHEEL TOUCHDOWN. FOUND ISFD BATTERY NOT SEATED IN RACK. SECURED ISFD BATTERY. OPS TEST IAW FIM 34-24-00-810-804. OK FOR SERVICE. (K)SDR AMTA200800228Battery · unsecureISFD WENT BLACK WITH NOSE WHEEL TOUCHDOWN. FOUND ISFD BATTERY NOT SEATED IN RACK. SECURED ISFD BATTERY. OPS TEST IAW FIM 34-24-00-810-804. OK FOR SERVICE. (K)SDR AMTA200800038Transceiver · faultyWXR FAIL MESSAGE SHOWED ON TRACK OFF ROLL AND CLIMB, WENT OUT AT 26,000 FT. T/S IAW FIM 34-43-410400-801.NO FAULT NOTED. REMOVED AND REPLACED WEATHER RADAR RECEIVER/TRANSCEIVER IAW AMM 34-43-410400-801. OPS CHECK NORMAL ON GROUND. (K)SDR AMTA200700658Fairing · damagedATTACHING SCREWS PULLING THROUGH ON LEFT WING FLAP SUPPORT FAIRING NR 3. ACCOMPLISHED REPAIR IAW SAA EA 737-5753-09-A1103. (M)SDR AMTA200700592Regulator · unserviceableRT BLEED TRIP OFF LIGHT ILLUMINATED DURING CLIMB OUT. TRIP RESET BUTTOM EXTINGUISHED BLEED TRIP PFF OFF LIGHT. AFTER 1 MIN BLEED TRIP OFF LIGHT REILLUMINATED. REMOVED AND REPLACED RT ENGINE BLEED AIR REGULATOR IAW AMM 36-11-03-04 PERFORMED RT ENGINE BLEED ASDR AMTA200700585Plug · missingFOUND THE S16 HIGH PRESSURE TURBINE BORESCOPE PLUG NOT INSTALLED. REINSTALLED NEW PN 336-026-101-0 PLUG (S16) IAW MM 72-00-00 AND W/C 342I7202. OK FOR SERVICE. (K)SDR AMTA200700489Wedge · damagedSAA, INSPECTION FOUND NUMEROUS DENTS, CRACKS AND PUNCTURES ON THE RT IB AFT FLAP WEDGE LOWER SKIN PN 133A2700-18. REPAIRED IAW EA`S 737-5753-09A1099 AND 737-5753-09A1098. REPAIR IS INTERIM AND REQUIRES RE-INSPECTION EVERY 3500 FLIGHT CYCLES OR 24 MONTHS WHICSDR AMTA200700488Wedge · puncturedINSPECTION FOUND NUMEROUS DENTS, CRACKS AND PUNCTURES ON THE LT IB AFT FLAP TRAILING EDGE WEDGE LOWER SKIN PN 113A2700-17. ACCOMPLISHED REPAIR IAW SAA EA 737-5753-09-A1098. (M)SDR AMTA200700487Unknown · unknownINSPECTION OF THE SECONDARY FUEL VAPOR-BARRIER APPLICATION, WING CENTER SECTION TOP PANEL AND FRONT SPAR, 7 EA AREAS FAILED INSPECTION. C/W EO737-57-AD3096. (K)SDR AMTA200700473Sensor · unserviceableON CLIMBOUT OF LGA FLAPS FAILED TO RETRACT SHOWING ASYMETRIC CONDITION L 71/4 DEGREES R5 DEGREES. REMOVED AND REPLACED NR3 FLAP SKEW SENSOR IAW 27-59-01-2 OF MM OPS CHECK AND RIG CHECK GOOD. (K)SDR AMTA200700472Hinge · brokenRT AFT OVERWING EMERGENCY DOOR HINGE ASSY BROKEN. INSTALLED NEW SERVICEABLE DOOR HINGE IAW CMM 52-26-07. (K)SDR AMTA200700457Floor Support · corrodedAFT CARGO FLOOR SUPPORT HAS CORROSION FROM 787 TO 847 RBL 16.5. REMOVED CORROSION SRM 51-10-02 AND FOUND OUT OF LIMITS IAW SRM 53-00-53-1A2. FABRICATED FLOOR SUPPORT TRACK IAW EA 737-5300-09-A1104 AND INSTALLED IAW SRM 53-00-53-2R3 ITEM 4B 1 AND 2. TREATED SDR AMTA200700456Support Angle · crackedUPON REMOVAL OF AFT CARGO THRESHOLD WEB AT APPROX STA 810 FOUND SUPPORT ANGLE CRACKED. REMOVED SUPPORT ANGLE SRM 51-40-02 FAB NEW ANGLE ON TRAVELER 7773560001 LOCATED NEW ANGLE IAW SRM 51-40-01 INSTALLED SUPPORT ANGLE SRM 51-40-02. (K)SDR AMTA200700445Skin · dentedRT LOWER FUSE HAS AN APPROX 14 INCH GOUGE THAT ENDS IN AN APPROX 3 INCH X 50 DENT, STA 797 BETWEEN STR 24R AND 27R JUST BELOW CARGO DOOR. REPAIRED IAW SAA EA 737-5361-09-A1102 24 MONTH TIME LIMITED REPAIR AND TRACKED BY ATA ERA 737-53R-6158. TREATED PRIMED ASDR AMTA200700388Sensor · malfunctionedINITIAL CLIMB DUCT PRESSURE L-15, R42 PSI, AT 16,000, N1 96.3, L 13, R 32 PSI, AT 27,000, L13, R 26, N1 98.7 IN CRUISE AT 370, L18, R 28. ON DESCENT BOTH MATCH UP. REMOVED AND REPLACED NR 1 ENG 450 TEMP SENSOR IAW MM 36-11-05-4. (K)SDR AMTA200700378Regulator · unserviceableDUCT PRESSURE SPLIT ON CLIMB AT 10,000 FT L14/ R34 20K, L13 R32, 30K, L13, R24, AT CRUISE 380K L16/R23. REMOVED AND REPLACED NR 1 ENG BLEED AIR REGULATOR IAW 36-11-03-4.SDR AMTA200700375Charger · unserviceableISFD DISPLAY BLANK. REMOVED AND REPLACED THE DBC IAW 34-24-00, ISFD. OPS CHECKS GOOD. OK FOR SERVICE. (K)SDR AMTA200700356Sensor · unserviceableRT BLEED TRIPOFF LIGHT ILLUMINATED IN FLIGHT. WOULD NOT RESET WITH TRIP RESET BUTTON. REMOVED AND REPLACED PRECOOLER CONTROL VALVE SENSOR IAW MM 36-12-03-4. OPS CHECK NORMAL. OK FOR SERVICE. (K)SDR AMTA200700322Processor · unserviceableCENTER FUEL TANK QTY BLANKS INTERMITTENTLY. (K) REMOVED AND REPLACED FUEL QTY PROCESSOR UNIT, C/W OPS CHECK, OPS CHECK GOOD. NO FAULTS NOTED AT THIS TIME IAW AMM 28-41-81. (K)SDR AMTA200700321Indicator · inoperativeCENTER TANK FUEL QUANTITY INDICATION BLANK. PERFORMED FQIS BITE IAW FIM 28-41-00-810-801, INDICATION NORMAL. (K)SDR AMTA200700320Indicator · inoperativeCENTER TANK QUANITY INDICATOR BLANK, NOT SHOWING ANY QUANITY. PERFORMED FQIS BITE PROCEDURE IAW FIM 28-41-00-810-810. NO FAULTS DETECTED. OK FOR SERVICE. (K)SDR AMTA200700288Fuel Control · inoperativeAPU WOULD NOT START FAULT LIGHT ILLUM. REPLACED FCU IAW AMM 49-31-11-4 AND PERFORMED APU BITE CHECK. NO FAULTS ON SEVERAL STARTS. (K)SDR AMTA200700284Element · malfunctionedWING-BODY OVERHEAT LIGHT ON RT SIDE (LIGHT CAME ON WHEN CONFIGURED FOR A APU ON/NO BLEED TAKE-OFF. REMOVED AND REPLACED M269 ELEMENT. IAW MM 26-18-02-400-801. OPS CHECK NORMAL. NO FAULTS NOTED IAW FIM. OK FOR SERVICE. (K)SDR AMTA200700267Controller · malfunctionedRT PACK LIGHT CAME ON JUST AFTER TAKEOFF. LIGHT STAYED OFF AFTER RESET. MAX POWER T/O, OAT 28C. PERFORMED PACK/ZONE TEMP CONTROLLER BITE PROCEDURE IAW FIM 21-62-00-810-801. NO FAULTS NOTED, OK FOR SERVICE. (K)SDR AMTA200700197Battery · inoperativeFLASHLIGHT IN AFT GALLEY INOPERATIVE. REMOVED AND REPLACED FLASHLIGHT BATTERY IN AFT GALLEY REF 25-64-00. OPS CHECK GOOD. (K)SDR AMTA200700189Battery Pack · dischargedL1 ENTRY DOOR AREA EGRESS LIGHTS INOP. REMOVED AND REPLACED BATTERY PACK IAW MM 35-51-06-2. OPS CHECKS GOOD. OK FOR SERVICE. (K)SDR AMTA200700125Power Supply · dischargedAFT RT WING OVER WING EMERGENCY EXTERIOR LIGHT INOPERATIVE. REMOVED AND REPLACED EMERGENCY POWER SUPPLY AT STA 727. LIGHT OPS CHECK GOOD. (K)SDR AMTA200700079Electrical Box · malfunctionedINFLIGHT AT CRUISE ALT FUMES SMELLED AT ROWS 1, 2 AND 3 ON LT SIDE. APPEAR TO BE ELECTRICAL SMELL. REMOVED AND REPLACED SEB AT ROW 2 ABC IAW MM. OPERATIONAL CHECK NORMAL. (K)SDR AMTA200600567Control Valve · unserviceableGATE RETURN - PACK LIGHT ON GROUND, LIGHT COMES ON AGAIN AFTER RESET, LEFT PACK. REMOVED AND REPLACED LEFT PACK TEMP CONTROL VALVE, MM REF 21-51-10. OPS CHECK GOOD. OK FOR SERVICE. (M)SDR AMTA200600459Warning Light · illuminatedRT SIDE WINDOW OVERHEAT LIGHT ON IN FLIGHT. REPLACED RT. SIDE WINDOW IAW 56-12-11-4. OP CHECKS NORMAL. (K)SDR AMTA200600425Warning Light · false indicationRT PACK LIGHT CAME ON AFTER TAKEOFF. LIGHT STAYED OUT AFTER RESET. PERFORMED BITE CHECK ON BOTH CONTROLLER NO FAULTS. INSPECT PACK INLET/EXHAUST NO OBSTRUCTIONS. PACK CHECKS NORMAL ON GROUND AT MDW AMM. (K)SDR AMTA200600352A/C Pack · trippedRT PACK TRIP ON T/O. RESET OK IAW QRH. OP CHECK OK IAW MM. (K)SDR AMTA200600281Hmu · fluctuatesAFTER 10 MINUTES OF NORMAL GROUND OPS NR 1 ENG WOULD NOT ACCELERATE WITH THROTTLE MOVEMENT AND FLAME OUT. REMOVED AND REPLACED HMU IAW AMM. LEAK CHECK NORMAL. OPS CHECK NORMAL.SDR AMTA200301054Lens · missingRIGHT SIDE OVERWING AFT LOWER EMERGENCY LIGHT LENSE ASSEMBLY MISSING. INSTALLED NEW LIGHT ASSEMBLY, OPS CHECK GOOD REF MM 33-51-01-2. (M)SDR AMTA200300890Power Supply · malfunctionedALL EGRESS LIGHTS AROUND LEFT AFT SERVICE DOOR INOPERATIVE. RESET POWR SUPPLY WITH SWITCH PER 737 MM 33-51-00. LIGHTS OPS CHECKED NORMAL. (M)SDR 2003F00085Retainer · defectiveGIRT BAR RETAINER DEFECTIVE AT L1 DOOR. ADJUSTED GIRT BAR RETAINER HOOKS, OK FOR SERVICE.