N335EN, cancelled Mar 13, 2019

Service difficulty reports · 112

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N335EN' AND deregistration_id = 'N335EN-2019-03-13'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR HNAA2018022600042Light · inoperativeIN CRUISE FLT AT ABOUT 8K, FUMES IN CABIN AROUND ROW 6, FLT ATTENDENT TURNED CABIN LIGHTS OFF, NO CHANGE. SELECTED NR 2 BLEED AND NR 1 PACK OFF SMELL DISAPATED WHILE AIRCRAFT WAS DEPRESSURIZING. FOUND O/H LIGHT AT ROW 8A/C BURNT OUT. INSP LIGHT FIXTURE, NO DEFFeb 24, 2018 · N335EN · Dhav DHC8311 · Lighting SystemSDR HNAA2017121100386Brush Block · damagedPDIS 335 33-51 1362691 07DEC17 SBY CLOSE FA REPORTED EMERGENCY LIGHTS FLICKERING WHEN PROP HE AT L/H "B" PHASE WAS CYCLING 29311 00 EK FACT 08DEC17 04:55 SBY R&R BOTH ENG BRUDec 7, 2017 · N335EN · Dhav DHC8311 · Propeller/Rotor Anti-Ice/De-Ice SystemSDR HNAA2017102300356Unknown · odorBURNING ODOR COMING FROM BETWEEN CAPTAIN`S SEAT AND WARDROBE. INSPECTED AREA FOR HIDDEN DEFECTS. NO DEFECTS NOTED. GROUND RAN THE ACFT. OK FOR SERVICE.Oct 22, 2017 · N335EN · Dhav DHC8311 · Air Distribution SystemSDR HNAA2017102300355Unknown · odorF/A REPORTED AN ELECTRICAL BURNING ODOR COMING FROM THE WARDROBE. INSPECTED THE WARDROBE AND FLIGHT ATTENDANT LIGHT PANEL SURROUNDING. NO SIGNS OF BURNING, ARCHING OR SMOKE. GROUND RAN THE AIRCRAFT NO DEFECTS NOTED. OK FOR SERVICE.Oct 20, 2017 · N335EN · Dhav DHC8311 · Air Distribution SystemSDR HNAA2017092500325Hose · rupturedIN FLIGHT, NR 2 ENGINE OIL PSI DROPPED TO ZERO FOLLOWED BY A NR 2 ENGINE FIRE INDICATION. PERFORMED ENGINE SHUTDOWN AND USED BOTH BOTTLES, FIRE INDICATION EXTINGUISHED AND PERFORMED A SINGLE ENGINE LANDING. REMOVED AND REPLACE THE NR 2 ENGINE IAW WC71-02-02.Sep 24, 2017 · N335EN · Dhav DHC8311 · Turbine Engine Oil SystemSDR HNAA2017081400270Radar · malfunctionedWEATHER RADAR WILL NOT PAINT KNOWN WEATHER. R & R THE WEATHER RADAR R/T IAW AMM 34-41-01.GROUND TESTED GOOD, OK FOR SERVICE.Aug 12, 2017 · N335EN · Dhav DHC8311 · Weather Radar SystemSDR HNAA2017061400207Hydraulic System · leakingAFTER TAKE OFF, DURING CLIMB THEOUGH 400 FT. BOTH BLEEDS AND LEFT PACK TURNED ON WHEN SMOKE AND A FOUL ODOR FILLED THE FLIGHT DECK. BLEEDS AND PACK TURNED OFF, SMOKE AND ODOR SUBSIDED. GROUND RAN THE ACFT WITH BLEEDS AND PACK ON FOR 10 MINUTES. NO SMOKE Jun 13, 2017 · N335EN · Dhav DHC8311 · Hydraulic System, MainSDR HNAA2017052700190Autofeather Sys · malfunctionedREJECTED TAKE OFF DUE TO AUTOFEATHER FAILURE TO ARM. CYCLED POWER LEVERS AND PDPU. PERFORMED AUTOFEATHER TEST IAW RUN UP MANUAL SYSTEM. OPS CHECKED GOOD, NO DEFECTS NOTED. OK FOR SERVICE.May 27, 2017 · N335EN · Dhav DHC8311 · Propeller Feathering/ReversingSDR HNAA2017051200165Holder · arcedWHEN CABIN OVERHEAD LIGHTS ARE ON, AN ELECTRICAL ODOR IS NOTICED IN MID CABIN. MAINTENANCE INSPECTED AND FOUND THE OVERHEAD LIGHT AT 3A ARCING. INSPECTED AREA NO FURTHER DAMAGE NOTED. DEACTIVATED OVERHEAD LIGHTS. PULLED AND COLLARED CIRCUIT BREAKERS S1 - S2 May 11, 2017 · N335EN · Dhav DHC8311 · Passenger Compartment LightingSDR HNAA2017031700088Igniter · failedNR 1 ENGINE WILL NOT LIGHT OFF. REMOVED AND REPLACED THE NR 1 ENGINE IGNITERS.Mar 17, 2017 · N335EN · Dhav DHC8311 · Ignition Harness (Distribution)SDR HNAA2017020800041Bulb · inoperativeFIRST RED EMERGENCY LIGHT INOPERATIVE AT ROW 1. R & R BULB.Feb 7, 2017 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2017020100033Lens · detachedRIGHT SIDEWALL LIGHT LENS FELL DOWN AFTER TAKE OFF AT ROWS 4-7. REMOVED AND REPLACED SIDEWALL LIGHT LENS AS REQUIRED. OKAY FOR SERVICE.Feb 1, 2017 · N335EN · Dhav DHC8311 · Passenger Compartment LightingSDR HNAA2017012300025Bulb · inoperativeFLOOR EMERGENCY LIGHTS ARE INOPERATIVE 4TH AND 20TH FROM FRONT. REMOVED AND REPLACED THE BULBS. OPS CHECKED GOOD.Jan 23, 2017 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2016121200385Circuit Breaker · unknownBOTH FO'S EFIS DISPLAYS ARE BLANK. FOUND CIRCUIT BREAKERS F6 AND G6. RESET THE CIRCUIT BREAKERS AS REQUIRED. EFIS SYSTEM OPS NORMAL OK FOR SERVICE.Dec 9, 2016 · N335EN · Dhav DHC8311 · Attitude and Direction Data SystemSDR HNAA2016102100326Bulb · inoperativeEMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE BULBS. OPS CHECKED GOOD.Oct 21, 2016 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA20161700320Bulb · inoperativeEMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE BULB. OPS CHECKED GOOD.Oct 17, 2016 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2016100500308Battery Pack · inoperativeLEFT FORWARD EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE BATTERY PACK AT PS1. OPS CHECKED GOOD.Oct 5, 2016 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2016091600283Eadi · malfunctionedF/O EADI WENT BLANK AND CB 6F WAS TRIPPED. RESET CB 6F AND C/W OPS CK OF EHSI. OK FOR SERVICE.Sep 14, 2016 · N335EN · Dhav DHC8311 · Attitude Gyro and Indicating SystemSDR HNAA2016082600256Vane · malfunctionedNR 2 STALL SYS FAIL AND STICK PUSHER FAIL C/L DURING TAXI. RE-SET NR 2 AOA VANE. C/L EXTINGUISHED. OPS CHECK GOOD. OK FOR SERVICE.Aug 25, 2016 · N335EN · Dhav DHC8311 · Stall Warning SystemSDR HNAA2016053100156Circuit Breaker · failedNR 1 AUXILIARY PUMP APPEARED NOT TO WORK. DISCONNECTED MAIN AND AUXILIARY BATTERY CONNECTORS. SHORT SIGNED 281933. FOUND CIRCUIT BREAKER NR 1 FUEL AUXILIARY PUMP BAD. RNR C/B 2821-CB1, NR 1 FUEL AUXILIARY PUMP, AUXILIARY PUMP, OPS CHECK GOOD RECONNECTED MAMay 27, 2016 · N335EN · Dhav DHC8311 · Fuel System WiringSDR HNAA2016052500151Smoke Detector · no testLAV SMOKE DETECTOR WILL NOT TEST. R & R LAV SMOKE DETECTOR USING RETAINED HARDWARE, OPS CK GOOD, PN PU90-461.May 25, 2016 · N335EN · Dhav DHC8311 · Smoke DetectionSDR HNAA2016042500122Wire · brokenCENTER FLOOR LIGHT WIRE BROKEN ON EMERGENCY LIGHTS. SPLICED NEW WIRE, OPS GOOD.Apr 23, 2016 · N335EN · Dhav DHC8311 · Light System WiringSDR HNAA2016042500121Diode · brokenDIODE BROKEN CENTER FLOOR ON EMERGENCY LIGHT. R & R DIODE.Apr 23, 2016 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2016032900094Unknown · odorDURING CRUISE, A STRONG OIL ODOR IN FLT DECK. DISSIPATED WITH BLEEDS SELECTED OFF. NO ODOR IN CABIN NOTED. REF SEQ 1 SAME LP. PERFORMED OPS CHECK OF BLEEDS WITH FLIGHT DECK PACK, NO OIL ODOR NOTED. PACK OPS NORMAL, OK FOR SERVICE.Mar 26, 2016 · N335EN · Dhav DHC8311 · Air Distribution SystemSDR HNAA2016032900092Pressure Switch · inoperativeDURING FLIGHT, NR 1 TORQUE INDICATIONS FLUCTUATING PLUS, MINUS 5 PCT WITH NR 1 BLEED HOT CT LIGHT ILLUMINATION. SELECTED NR 1 BLEED OFF AND NR 2 TORQUE INDICATOR FLUCTUATING, 5 PCT WITH NR 2 BLEED HOT CT LIGHT ILLUMINATED, SEL NR 2 BLEED OFF. TORQUE INDICATOMar 26, 2016 · N335EN · Dhav DHC8311 · Pneumatic Distribution SystemSDR HNAA2016032500090Bulb · inoperativeFORWARD F/A EMERGENCY LIGHT ROCKER SWITCH BULB IS INOPERATIVE IN NORMAL POSITION. R & R BULB IN F/A EMERGENCY LIGHT ROCKER SWITCH. OPS CHECKED GOOD.Mar 25, 2016 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2015122500373Bulb · inoperativeEMERGENCY LIGHTS ARE INOPERATIVE AT ROWS 4DF AND 11DF. PULLED EMERGENCY ESCAPE FLOOR PATH LIGHT COVER. R & R BULBS. OPS CHECKED GOOD. REINSTALLED COVER.Dec 25, 2015 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2015080700252Smoke Detector · failedAFT CARGO SMOKE DETECTOR IS HOT AND EMITS AN ODOR. R & R AFT CARGO SMOKE DETECTOR. OPS CHECKED GOOD. OK FOR SERVICE.Aug 7, 2015 · N335EN · Dhav DHC8311 · Smoke DetectionSDR HNAA2015052700169Warning Light · illuminatedLF 26AC BUSS CAUTION LIGHT ILLUMINATED AFTER TAKEOFF, PRIMARY, SECONDARY AND AUX INVERTERS LOADS NORMAL. NO LOSS OF SERVICE FROM LF 26AC BUSS. CAUTION LIGHT EXTINGUISHED AFTER SEVERAL MINUTES. R & R CAUTION LIGHT PANEL IAW 33-12-00. GROUND RAN ACFT. OPS CHECMay 27, 2015 · N335EN · Dhav DHC8311 · Central WarningSDR HNAA2015030200065Bulb · inoperativeOVERHEAD EMERGENCY EXIT LIGHTED SIGN IS INOPERATIVE AT ROW 11. R & R BULB. OPS CHECKED GOOD.Mar 2, 2015 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2015021600050Module · inoperativeEMERGENCY LIGHT IS INOPERATIVE AT ROW 12. R & R THE LIGHT MODULE AT ROW 12 EMERGENCY LIGHT. OPS CHECKED GOOD.Feb 16, 2015 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2015021600049Bulb · inoperativeLEFT EMERGENCY DOOR LIGHT IS INOPERATIVE AT ROW 11. R & R BULB AT EMERGENCY DOOR. OPS CHECKED GOOD.Feb 16, 2015 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2014121500363Line · leakingF/A REPORTS STRONG ODOR CAUSING COUGHING, WHILE TAXIING, AFTER LANDING. FOUND HYD LEAK UNDER SEAT 3DF. REPAIRED USING RING-LOCK IAW 20-55-55 AND SEAT WC 25-00-03R. OPS CHECKED GOOD. OK FOR SERVICE.Dec 15, 2014 · N335EN · Dhav DHC8311 · Hydraulic System, MainSDR HNAA2014120500345Bulb · inoperativeTHREE EMERGENCY LIGHTS ARE BURNED OUT. R & R THE BULBS. OPS CHECKED GOOD.Dec 5, 2014 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2014052100159Bulb · inoperativeFLOOR PATH LIGHT IS INOPERATIVE AT ROW 9. R & R BULB, OPS CHECKED GOOD.May 21, 2014 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2014032400107Bulb · inoperativeNORMAL GREEN LIGHT FOR EMERGENCY LIGHT PUSH BUTTON IS INOPERATIVE. R & R BULB IN PUSH BUTTON SWITCH. OPS CHECKED GOOD.Mar 24, 2014 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2014031900096Unknown · hazeWITH APU BLEEDS SELECTED ON, CABIN FILLED WITH HAZE. CREW GROUND RAN ENGINES WITH BLEEDS SELECTED ON. NO HAZE OR ODOR NOTED. RAN APU WITH BLEEDS ON. NO ODOR OR HAZE NOTED. OK FOR SERVICE.Mar 19, 2014 · N335EN · Dhav DHC8311 · Air Distribution SystemSDR HNAA2014020700036Bulb · inoperativeEMERGENCY LIGHT ON FORWARD CABIN ENTRANCE BULKHEAD IS INOPERATIVE. REMOVED LENS, R & R BULB, AT SAID LOCATION. REINSTALLED LENS. OPS CHECKED GOOD.Feb 7, 2014 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2014020700035Bulb · dimRIGHT FORWARD FUSELAGE EXTERIOR EMERGENCY LIGHT IS DIM. REMOVED LENS, R & R BULB, AT SAID LOCATION, REINSTALLED LENS. OPS CHECKED GOOD.Feb 7, 2014 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2013120200594Seal · contaminatedSMOKE ENTERING CABIN FROM FORWARD EMERGENCY EXIT DOOR. REMOVED FORWARD EMERGENCY EXIT DOOR AND FOUND DEICE FLUID AROUND BOTTOM SEAL. CLEANED AREA AND FOUND THE SMOKE TO BE STEAM FROM THE FLUID EVAPORATING. INSTALLED EXIT DOOR AS REQUIRED. OK FOR SERVICE.Dec 2, 2013 · N335EN · Dhav DHC8311 · Emergency ExitsSDR HNAA2013111300572Unknown · odorF/A AND PASSENGER REPORTED BURNING ODOR IN CABIN, THEN DISAPPATED. INSPECTED ACFT OVERHEAD LIGHTS AND GROUND RAN ACFT WITH BLEEDS ON. NO ODOR NOTED AT THIS TIME. OK FOR SERVICE.Nov 13, 2013 · N335EN · Dhav DHC8311 · Air Distribution SystemSDR HNAA2013102100543Module · brokenEMERGENCY LIGHT HAS TWO BROKEN MODULES. R & R LIGHT MODULES IAW AMM 20-45-07. OPS CHECKED GOOD.Oct 21, 2013 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2013081600465Doubler · corrodedLAV DOUBLER CORRODED ON LOWER EDGE, AFT SIDE. CUT OUT CORROSION IAW RD8-53-2103. COMPLIED WITH EDDY CURRENT INSPECTION. NO DEFECTS NOTED. REPAIRED LAV DOUBLER AND INSTALLED NEW LAV DOOR IAW E08-53-13-0473.Aug 16, 2013 · N335EN · Dhav DHC8311 · Fuselage Main, Plate/SkinSDR HNAA2013070500390Propeller · malfunctionedUNABLE TO GET NR 1 PROP RPM BELOW 927. ADJUSTED NR 1 PCU SPEED TRIM SCREW IAW MM 61-22-00. PROP SPEED AT 911 RPM. OK FOR SERVICE.Jul 5, 2013 · N335EN · Dhav DHC8311 · Propeller SystemSDR HNAA2013052100303Fan · inoperativeCIRCUIT BREAKER N5 TRIPPED AND WILL NOT RESET. ACFT OVER PRESSURIZED AND UNABLE TO CONTROL EITHER PACK. FOUND FLIGHT DECK TEMP SENSOR FAN BAD. R & R TEMP SENSOR FAN. OPS CHECKED GOOD.Jun 7, 2013 · N335EN · Dhav DHC8311 · Air Distribution FanSDR HNAA2013052100301Sensor · malfunctionedSMOKE IN FLIGHT DECK ACCOMPANIED BY CIRCUIT BREAKER OPENING. REPLACED FLIGHT DECK TEMP SENSOR.May 18, 2013 · N335EN · Dhav DHC8311 · Cabin Temperature SensorSDR HNAA2013051700293Bulb · failedEMERGENCY SIDEWALL LIGHT IS INOPERATIVE AT ROW 2DF. R & R BULBS, OPS CHECKED GOOD.May 17, 2013 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2013051700292Bulb · failedEMERGENCY FLOOR PATH LIGHTS ARE INOPERATIVE AT ROW 1. R & R BULB, OPS CHECKED GOOD.May 17, 2013 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2013030400106Bulb · burned outEMERGENCY FLOOR LIGHT IS OUT AT ROW 13. R & R BURNED OUT BULB FOR EMEGENCY FLOOR LIGHT. OPS CHECKED GOOD.Mar 4, 2013 · N335EN · Dhav DHC8311 · Emergency LightingSDR HNAA2013022700095Boot · damagedIN ALL MODES, RT MOST INBD DEICE BOOT WILL NOT INFLATE AND HAS NO INDICATION. PATCHED L/E AS NEEDED IAW AMM 30-10-48. OPS CHECKED GOOD. OK FOR SERVICE.Feb 27, 2013 · N335EN · Dhav DHC8311 · Airfoil Anti/De-ice System
Back to N335EN, cancelled Mar 13, 2019