N339UA, cancelled Mar 18, 2013
Service difficulty reports · 71
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N339UA' AND deregistration_id = 'N339UA-2013-03-18' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N339UA' AND deregistration_id = 'N339UA-2013-03-18' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009061201662Feeder Cable · faultyCABIN EEL FLOOR LIGHTS INOP FROM ROW 16 TO AFT GALLEY. REPLACED FLOOR FEEDER CABLE, ALL LIGHTS OPERATE NORMAL.SDR UALA2009050601300Light · inoperativeDURING EMERGENCY LIGHT TEST, FOUND MOST AFT EEL STRIP INOP. REPLACED AFT CABIN SOLID LIGHT STRIP AND AFT CABIN LIGHT TAPE STRIPS ARE MISSING. INSTALLED EEL LIGHTING STRIPS, EEL LIGHTING OPS CHECKS NORMAL.SDR UALA2009031200761Skin · crackedMED 1R CRACK AT LWR AFT CORNER. STARTED DOUBLER/TRIPLER REPAIR. MAJOR REPAIR ACCOMPLISHED. COMPLETED DOUBLER, TRIPLER, QUADRUPLE REPAIR.SDR UALA2009020200342Fitting · crackedTHE 1 LT MED SURROUND STA 360 FRAME CLIP IS CRACKED. REPAIR WAS ACP PER UA-EVA-72282 AS A INTERIM REPAIR.SDR UALA2009010200001Feeder Cable · dirtyROW 15 TO BACK OF ACFT EEL LIGHTS ARE VERY DIM. CLEANED AND SECURED WALL FEEDER CABLE. OPS CHECK OK.SDR 2008UALA05889Fire Loop · faultyAPU FIRE BELL & HANDLE ILLUMINATE DURING TEST. APU FIRE DETECTOR FOUND FAULTY. REPLACED APU TAILPIPE OVERHEAT FIRE LOOP. APU FIRE DETECTION SYSTEM OPS CHECKS GOOD.SDR 2008UALA03672Feeder Cable · damagedEEL LIGHTS INOP ROW 15 & AFT. FOUND LEAD CABLE AND LIGHT STRIP BAD. REPLACED LEAD CABLE AND LIGHT SEGMENT OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA02904Slide · misinstalledDOOR 1R SLIDE PRESSURE GAUGE MISALIGNED. SUSPECT SLIDE IMPROPERLY INSTALLED. REPOSITIONED DOOR 1R SLIDE PACK. AC OK FOR SERVICE.SDR 2008UALA02404Structure · gougedRT OB TRAILING EDGE FOREFLAP HAS GOUGE APPROX .020 IN DEEP LOCATED .75IN INBD OF WBL 414.38. REPAIRED THE RIGHT HAND OUTBOARD FORE FLAP LEADING EDGE.
SDR UALA2008111302207Engine · leakingHEAVY "WET SOCKS" ODOR DURING TAKEOFF AND CLIMB. ENGINE HAS BEEN DETERMINED AS SOURCE OF ODOR. REMOVED & REPLACED NR 1 ENGINE ON ACCOUNT OF OIL WETTING AT HPC BLADES STAGES 1 THRU 3. SECURED CONNECTOR THAT WAS REMOVED TO COMPLY WITH 4950C. APU IS OPERATIVESDR 2008UALA02207Unknown · odorHEAVY "WET SOCKS" ODOR DURING TAKEOFF AND CLIMB.
SDR 2008UALA01916Battery · faultyFLASHLIGHT AFT CABIN INOP NOT BLINKING. FAULTY BATTERY. REPLACED BATTERY OPS CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA01640Light · inoperativeFOUND EEL LIGHTS INOP FROM ROW 15 BACK. REPLACED EEL LIGHT SECTION IN AFT GALLEY, OPS CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA01173Indicator · malfunctionedFLAPS DID NOT RETRACT FROM 1 ON TAKEOFF. CAME UP WITH ALTERNATE. FOUND FAULTY FLAP POSITION INDICATOR. TAPPING THE INDICATOR WOULD UNLOCK FLAPS. REPLACED THE FLAP POSITION INDICATOR. SHOP FOUND NO FAULT WITH INDICATOR.
SDR 2008UALA00921Cable · defectiveEEL LIGHTS INOP ROWS 12-14. REPLACED CABLE.SDR 2008UALA00109Angle · crackedHORIZONTAL STAB CENTER SECTION INTERIOR, RT DIAGONAL I BEAM TRUSS, AFT SIDE OF UPPER FLANGE, GUSSET STIFFENER CRACKED IN RADIUS. REPLACED ANGLE.
SDR 2008UALA00105Skin · puncturedNR 4 L/E SLAT, LOWER SKIN PUNCTURED JUST INBOARD OF ACTUATOR FROM UPSTOP PAD LODGED IN STRUCTURE. INSTALLED SPLICE PLATE AND FILLER REPAIR.SDR 2008UALA00082Skin · crackedLEFT HORZ STAB LOWER SKIN CRACKED JUST FWD OF 2ND BALANCE PANEL BAY AT AFT SPAR. INSTALLED EXTERNAL SKIN DOUBLER REPAIR.SDR 2008UALA00104Connector · disconnectedEEL FLOOR LIGHT STRIP INOP AT SEAT ROW 11. RESECURED CONNECTOR.SDR 2008UALA00103Skin · gougedRIGHT WING FIXED L/E GOUGED - PUNCTURED FROM DISLODGED UPSTOP JUST INBOARD OF NR 4 SLAT ACTUATOR. ACCOMPLISHED COMPOSITE SET-UP REPAIR PER SRM 51-70-17 REPAIR 7.SDR 2007UALA04481Curtain · out of positionCREW DESCENDED TO FL240 AND TURNED OFF RT PACK. WHEN OPERATING JUST ON LT PACK, AIRCRAFT WOULD NOT MAINTAIN PRESSURIZATION. CABIN ALT WARNING HORN WENT OFF AND DIVERTED. SUPPLEMENTAL DATA UPDATE CAUSE: E/E RAIN CURTAIN HAD BECOME LOOSE AND FELL ON TOP OF ASDR 2007UALA04151Flap · gougedLT INBOARD FORE FLAP INBOARD EDGE HAS GOUGES CREATED BY TOO LONG OF SCREWS INSTALLED IN UPPER FIXED PANEL. FOUND IMPROPER SCREW LENGTH INSTALLED IN PANEL ABOVE DAMAGED FLAP. REMOVED LT INB FORE FLAP AND SENT TO SHOP FOR REPAIR. A/C RECEIVED A ROBBED FLAP FROSDR 2007UALA03407Slide · unsecureDOOR 1L SLIDE CAME OFF DOOR. REPLACED DOOR SLIDE 1L AS A PRECAUTION.SDR 2007UALA02008Unknown · unknownRIGHT BLEED TRIPPED 3 TIMES IN A 10 MINUTE PERIOD AT FL370. DESCENDED TO FL310 TO STABILIZE CABIN PRESSURE. [07-06-07] ACCOMPLISHED BLEED CHECK. NO DEFECTS NOTED. BLEED RESET JUST BY PUSHING THE RESET BUTTON.SDR 2007UALA00127Unknown · malfunctionedLANDED UNDER AMBER ALERT DUE TO LOSS OF CABIN PRESSURE. FOUND DAMAGED DUCT AND MISSING CLAMP IN ELEVATOR ACCESS COMPARTMENT, WHERE APU DUCT ENTERS AT AFT PRESSURIZED BULKHEAD. REPLACED DUCT AND CLAMP.SDR 2007UALA00014Connector · dirtyON DESCENT THE NR 1 ENGINE SPAR VALVE CLOSED LIGHT IS ILLUMINATED WHILE THE ENGINE IS OPERATING, NO FUEL FLOW CHANGE OR DECREASE. FOUND DIRTY CONNECTOR ON NR 1 ENGINE SPAR VALVE ACTUATOR. CLEANED CONNECTOR. OPERATIONAL CHECKS NORMAL.SDR 2006UALA01989Light · inoperativeFOUND LOWER EMERGENCY SLIDE LIGHT INOP. REPLACED LIGHT.SDR 2006UALA01890Controller · unknownDURING CRUISE AT 35,000 FT HAD ALTITUDE WARNING HORN AND CABIN ALTITUDE WAS AT 10,000 FT AND INCREASING. COULD NOT CONTROL CABIN PRESSURIZATION IN AUTO OR STANDBY. "NO FAULT FOUND". REPLACED CABIN PRESSURE CONTROLLER.SDR 2006UALA01486Cabin Pressure · unknownLOST CABIN PRESSURE AT FL360. DECLARED EMERGENCY AND DESCENDED TO 8000 FT. FOUND OUTFLOW VALVE SEAL AND SEVERAL BELLY DRAINS LEAKING. RESEALED OUTFLOW VALVE AND CLEANED BELLY DRAINS.SDR 2006UALA01329Frame · damagedAFT PIT STA 747 BETWEEN S25R AND S24R FRAME CAP HAS ELONGATED HOLE. MAJOR REPAIR: REMOVED DAMAGE. FABRICATED AND INSTALLED STRAP REPAIR.SDR 2006UALA01328Skin Panel · misdrilledRT SKIN PANEL BS 795 AT STRINGER 20R HAS A HOLE WITH INADEQUATE EDGE DISTANCE. MAJOR REPAIR, ROUTED OUT AREA. FABRICATED AND INSTALLED EXTERNAL DOUBLER, TRIPLER AND STRUCTURAL FILLER REPAIR.SDR 2006UALA01327Skin Panel · damagedRT AFT SKIN PNL HAS HOLE WITH NO EDGE DISTANCE AT STA 846 UPPER SKIN LAP. REMOVED DAMAGE. FABRICATED AND INSTALLED TRIPLER, DOUBLER AND FILLER REPAIR.SDR 2006UALA01319Intercostal · crackedFOUND STA 294.5 S12L INTERCOSTAL CRACKED ON LOWER SURFACE. REMOVED DAMAGE. FABRICATED AND INSTALLED INTERCOSTAL.SDR 2006UALA01318Intercostal · crackedFOUND STA 294.5 S11L INTERCOSTAL CRACKED LOWER SURFACE. FABRICATED AND INSTALLED INTERCOSTAL.SDR 2006UALA01317Clip · crackedFOUND STA 294.5 S11L INTERCOSTAL CLIP CRACKED UPPER SURFACE. FABRICATED AND INSTALLED INTERCOSTAL.SDR 2006UALA01316Clip · crackedFOUND STA 360 S11L INTERCOSTAL CLIP CRACKED ON LOWER SURFACE. FABRICATED AND INSTALLED INTERCOSTAL.SDR 2006UALA01315Intercostal · crackedFOUND STA 295.5 S16L INTERCOSTAL CRACKED ON UPPER SURFACE. FABRICATED AND INSTALLED INTERCOSTAL.SDR 2006UALA01295Shear Tie · crackedFOUND SHEAR TIE IS CRACKED AT BOTTOM HOLE AT AFT PIT ST727B S23R-S24R. MAJOR REPAIR: REMOVED AND REPLACED SHEAR TIE.SDR 2006UALA01269Door Frame · crackedFWD GALLEY DOOR FWD FRAME LWR END IS CRACKED AT 2 EACH FASTENER HOLES. [06-29-07] MAJOR REPAIR: INSTALLED NEW SPLICE FRAME SECTION REPAIR.SDR 2006UALA01268Skin · crackedRT HORIZ STAB LOWER SKIN HAS 1.5 INCH CRACK, 2 INCHES FWD OF AFT EDGE AND 63 INCHES FROM INBD END. [06-27-07] MAJOR REPAIR: INSTALLED EXTERNAL SKIN DOUBLER REPAIR.SDR 2006UALA01243Floorbeam · corrodedCABIN FLOOR BEAM UPPER FLANGE CORRODED BS 947 RBL 16 TO 50 WL 208. [06-29-07] MAJOR REPAIR: INSTALLED A REINFORCING STRAP, ANGLE, AND FILLER REPAIR.SDR 2006UALA01242Floorbeam · corrodedCABIN FLOOR BEAM UPPER FLANGE IS CORRODED BS 986, LBL 5 TO RBL 18 WL 208. [06-29-07] MAJOR REPAIR: INSTALLED TEE CAP "L" ANGLE SPLICE REPAIR.SDR 2006UALA01212Crease Beam · corrodedFWD GALLEY DOOR CREASE BEAM CORRODED SEVERAL AREAS AT BS 294 - BS 360 RBL 55 - RBL 57 STR 17R.SDR 2006UALA01211Bulkhead · crackedLT MLG WW BULKHEAD BEADED WEB PANEL IS CRACKED AT BS 665 LBL31 WL 202.SDR 2006UALA00178Light · inoperativeEEL LIGHTS INOP FROM ROW 16 THROUGH 21.SDR 2006UALA00029Light · inoperativeEMERGENCY EXIT FLOOR LIGHTING INOP FROM ROW 16 TO AFT END OF AIRCRAFT.SDR 2004UALA01202Transmitter · malfunctionedRETURNED TO GATE AFTER 90 KNOT ABORTED TAKEOFF DUE TO OIL PRESSURE INDICATION. ENG 2 OIL PRESSURE WENT TO ZERO. REPLACED NR 2 OIL PRESSURE INDICATOR, OIL TEMPERATURE INDICATOR AND OIL PRESSURE TRANSMITTER. RAN ENGINE AND OPS CHECKED OK. THEN ON DEC 15, OILSDR 2004UALA00889Planetary Gear · wornDIVERTED UNDER AMBER ALERT WITH NR 2 ENGINE MOVED TO IDLE DUE TO NR 2 GENERATOR PROBLEM. REPLACED CSD AND CSD OIL COOLER. SHOP FOUND A WORN PLANETARY GEAR USED FOR INTERNAL CSD LUBRICATION.SDR 2002UALA01270Smoke · detectedCREW REPORTED ELECTRICAL SMELLING SMOKE FIRST SEEN AT CENTER AISLE DROP CEILING PANEL JUST FWD OF AFT GALLEY. OPERATED ALL EQUIPMENT, LIGHTS, LAV FLUSH ETC AND OBSERVED AREA DURING FERRY FLIGHT. NO ODOR OR VISIBLE SMOKE DETECTED.SDR 2002UALA01054Skin · dentedRIGHT HAND EXTERNAL FUSELAGE SKIN HAS DENT AT STATION 259 AND WL 173. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW DOUBLER AND FILLER.