Service difficulty reports · 117
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR 29GA2019111500001Circuit Breaker · trippedFLIGHT: 70 EYW/MCO EMERGENCY LIGHT CABIN EXIT CTL CB L8 POPPED TWICE RESET ONCE. CORRECTIVE ACTION: RESET CB PERFORMED OPERATIONAL CHECK OF EMERGENCY LIGHT SYSTEM, NO DEFECT WITH EXTERNAL POWER AND GENERATOR POWER.SDR 29GA2019081500002Power Supply · inoperativeL-8 CB (EMERGENCY LIGHT CONTROL) POPPED IN FLIGHT. CORRECTIVE ACTION: UNABLE TO DUPLICATE. CHECKED WIRES AT FLIGHT ATTENDANT PANEL FOR CONDITION AND SECURITY, NO DEFECT NOTED.
SUSPECT 24LN POWER SUPPLY AT FAULT AS MENTIONED IN ENGINEERING GROUP EMAIL OF WORK SDR 29GA2019081500001Wire · looseFLIGHT# 0140 VPS/MCO REPORT: L8 CB (EMERGENCY LIGHT CONTROL) POPPED INFLIGHT. CORRECTIVE ACTION: INSPECTED LH. EXTERIOR EMERGENCY LIGHT + FOUND LOOSE WIRE WITH DAMADED CONTACT PIN, R+R LH. EXTERIOR EMERGENCY LIGHT ASSY. INSTALLED NEW CONTACT PINS I.A.W AMM 33-
See all 117 reports