N448AM, cancelled Sep 25, 2013
Service difficulty reports · 80
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N448AM' AND deregistration_id = 'N448AM-2013-09-25' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N448AM' AND deregistration_id = 'N448AM-2013-09-25' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR TRBA20130312001Skin · corrodedDURING MX INSPECTION, FOUND "RT WING LOWER SKIN CORROSION AT REAR SPAR BETWEEN RIB 5-10. PERFORMED PERMANENT REPAIR IAW PART B.SDR TRBA20130206001Cover · misinstalledTHE CREW REPORTED THE COVER OF EMERGENCY LIGHT AT SERVICE DOOR MISINSTALLED. ACFT REMOVED FROM SERVICE. REPOSITIONED EMERGENCY LIGHT COVER AT SERVICE DOOR LOWER CORNER IAW CMM 33-51-27. ACFT RETURNED TO SERVICE.SDR TRBA20130128001Cover · crackedTHE CREW REPORTED THE SERVICE DOOR EMERGENCY LIGHT LENS WAS CRACKED. THE ACFT WAS REMOVED FROM SERVICE. R & R THE SERVICE DOOR EMERGENCY LIGHT LENS IAW JIC 33-51-24. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121127002Skin · corrodedDURING MX INSPECTION, FOUND CORROSION AT RT WING BOTTOM T/E BETWEEN RIB 6 AND 10. ACFT REMOVED FROM SERVICE. INSTALLED RT WING T/E RIB 8-10 PANEL JIC 53-93-00 RAI-10000. ACFT RETURNED TO SERVICE.SDR TRBA20121126010Fastener · corrodedDURING MX INSPECTION, FOUND THE RT WING FASTENERS AT T/E BETWEEN RIB 8-13 WITH CORROSION. ACFT REMOVED FROM SERVICE. INSTALLED RT WING T/E RIB 8-10 PANEL JIC 53-93-00 RAI-10000. ACFT RETURNED TO SERVICE.SDR TRBA20121126009Hinge · corrodedDURING MX INSP, FOUND THE T/E ACCESS PANEL HINGE CORRODED. THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED CORROSION AT T/E ACCESS PANEL HINGE IAW SRM 51-21-42. NO MATERIAL REMOVED. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121126008Access Panel · corrodedDURING MX INSPECTION, FOUND CORROSION ON THE RT T/E ACCESS PANEL HINGE NEAR RIB 5-6. THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED RT WING T/E ACCESS PANEL HINGE NEAR RIB 5-6. NO MATERIAL WAS REMOVED IAW SRM 51-21-42. THE ACFT WAS RETURNED TO SERSDR TRBA20121126007Skin · corrodedDURING MX INSPECTION, FOUND CORROSION AT THE RT WING L/E BETWEEN RIB 4-5. THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED RT WING L/E BETWEEN RIB 4-5 NO MATERIAL WAS REMOVED IAW SRM 51-21-42. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121126006Drain Valve · corrodedDURING MX INSP FOUND THE RT WING INBD AFT WATER DRAIN VALVE WITH CORROSION. THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED RT WING INBD AFT WATER DRAIN VALVE NO MATERIAL WAS REMOVED IAW SRM 51-21-42. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121126005Pump · corrodedDURING MX INS FOUND THE RT WING ELECTRIC FUEL PUMP WITH CORROSION AROUND FASTENERS (BOLT). THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED RT WING ELECTRIC FUEL PUMP AROUND FASTENER (BOLT) NO MATERIAL WAS REMOVED IAW SRM 51-21-42. THE ACFT WAS RETURNEDSDR TRBA20121126004Rib · corrodedDURING MX INSP FOUND CORROSION AROUND FASTENER AT LT WING T/E NEAR RIB 8 AREA. THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED CORROSION AT LT WING T/E FASTENER NEAR RIB 8 AREA IAW SRM 51-21-42. NO MATERIAL REMOVED. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121126003Rib · corrodedDURING MX INSP FOUND CORROSION SPOT AT LT WING NEAR RIB 6 CENTER AREA. THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED CORROSION AT LT WING NEAR RIB 6 CENTER AREA IAW SRM 51-21-42. NO MATERIAL REMOVED. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121126002Drain Valve · corrodedDURING MX INSP FOUND THE LT WING INBD WATER DRAIN VALVE BOTH WITH CORROSION. THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED CORROSION AT LT WING INBD WATER DRAIN VALVE IAW SRM 51-21-42. NO MATERIAL REMOVED. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121126001Pump · corrodedDURING MX INSPECTION, FOUND THE LT WING ELECTRIC FUEL PUMP WITH CORROSION AROUND FASTENERS (BOLT). THE ACFT WAS REMOVED FROM SERVICE. CLEANED AND TREATED CORROSION AT LT WING ELECTRIC FUEL PUMP IAW SRM 51-21-42. NO MATERIAL REMOVED.SDR TRBA20121116001Lens · crackedFLIGHT 4847, CREW REPORTED THE SERVICE DOOR EMERGECNY GROUND FLOOD LIGHT LENS CRACKED AND WAS INOPERATIVE. THE ACFT WAS REMOVED FROM SERVICE. R & R SERVICE DOOR GROUND FLOOD LIGHT IAW JIC 33-50-00. THE OPS CHECKED GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20121115003Handle · inoperativeTHE CREW REPORTED THE EMERGENCY ESCAPE HANDLE WAS BROKEN. THE ACFT WAS REMOVED FROM SERVICE. EMERGENCY ESCAPE HANDLE MISSING SCREW INSTALLED IAW MM 52-22-10. THE AFT WAS RETURNED TO SERVICE.SDR TRBA20121020001Channel · corrodedDURING MX INSPECTION, FOUND THE TAIL CONE NUTPLATE GANG LT AND RT CHANNELS TO HAVE CORROSION BEYOND LIMITS. THE ACFT WAS REMOVED FROM SERVICE. REPLACED DAMAGED SECTIONS OF LT AND RT TAIL CONE NUTPLATE GANG CHANNELS IAW MM 53-91-30, SRM 53-91-24 AND EO E2-530SDR TRBA20120714001Wire · damagedDURING MX INSPECTION, FOUND THE EMERGENCY LIGHT (GROUND FLOOD LIGHT) ON PASSENGER STAIRS ENTRY DOOR INOPERATIVE. ACFT REMOVED FROM SERVICE. SECURED WIRE TO PIN " E " C/P 253VC. OPS CHECKED GOOD IAW AWM 52-71-01 AND AMM 33-51-00. ACFT RETURNED TO SERVICE.SDR TRBA20120706001Cap · missingTHE CREW REPORTED THE END CAP ON THE FLOOR EMERGENCY EXIT LIGHT IN FRONT OF THE AFT GALLEY CART IS MISSING. THE ACFT WAS REMOVED FROM SERVICE. INSTALLED END CAP EMERGENCY LIGHT IN FRONT OF AFT GALLEY CART IAW 25-28-21 RAI 10000-006. THE ACFT WAS RETURNED TO SDR TRBA20120627002Power Supply · inoperativeDURING MAINTENANCE INSPECTION, FOUND PAX DOOR EMERGENCY LIGHT INOPERATIVE. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED THE EMERGENCY POWER SUPPLY 62W1 IAW JIC 33-51-21 AND REMOVED AND REPLACED THE EMERGENCY PASSENGER DOOR LIGHT ASSEMBLY, IAW JIC 52-1SDR TRBA20120604001Cap · missingDURING B INSPECTION, FOUND THE EMERGENCY FLOOR LIGHT STRIP MISSING END CAP IN GALLEY AREA. THE ACFT WAS REMOVED FROM SERVICE. INSTALLED EMERGENCY FLOOR LIGHT STRIP END CAP IN GALLEY AREA IAW JIC 25-28-21 RAI 10000. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20120527001Connector · looseON FLIGHT 4962, THE CREW REPORTED THE EMERGENCY LIGHT OUTSIDE SERVICE DOOR CHECK FOR LOOSE CONNECTION HAS TO BE HIT ON THE OUTSIDE TO WORK. THE ACFT WAS REMOVED FROM SERVICE. RE-SECURED LOOSE BULB, OPS CK NORMAL IAW AMM 33-50-00. THE ACFT WAS RETURNED TO SERSDR TRBA20120521002Lamp · inoperativeTHE CREW REPORTED THE EXIT FLOOD LIGHT ON MAIN ENTRY DOOR STAIRS INOPERABLE. THE ACFT WAS REMOVED FROM SERVICE. RELAMPED FLOOD LIGHT ON PASSENGER DOOR STAIRS. THE OPS CHECK WAS GOOD IAW JIC 33-00-00. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20120521001Cap · missingDURING B INSPECTION, FOUND THE EMERGENCY FLOOR LIGHT STRIP END CAP MISSING AT GALLEY AREA. THE ACFT WAS REMOVED FROM SERVICE. INSTALLED EMERGENCY FLOOR LIGHT STRIP END CAP AT GALLERY IAW CMM 33-52-10. THE OPS CHECKED GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA20120507002Cap · missingDURING B-INSPECTION, FOUND THE EMERGENCY FLOOR LIGHT STRIP MISSING AN END CAP IN GALLEY AREA. THE ACFT WAS REMOVED FROM SERVICE. FOUND MISSING EMERGENCY FLOOR LIGHT STRIP END CAP AND REINSTALLED IN GALLEY AREA IAW JIC 25-28-21 RAI 11000. THE OPS CHECK WAS GSDR TRBA20120210001Structure · damagedTHE CREW REPORTED THAT ON CLIMBOUT, AFTER TAKEOFF THERE WAS A BIG BIRD STRIKE ON NOSE OF ACFT. THE CREW ELECTED TO RETURN TO DEPARTURE AND LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. REPAIRED DAMAGE IAW EO E2-53MR-312 AND EO E2-53MR-313. ACFT RETUSDR TRBA20120305003Cap · missingON FLIGHT 4925, THE CREW REPORTED THE COVER OVER AFT FLOOR EMERGENCY EXIT LIGHT IN FRONT OF AFT GALLEY CART IS MISSING. THE ACFT WAS REMOVED FROM SERVICE. INSTALLED COVER ON AFT FLOOR EMERGENCY LIGHT IAW ATR 72 JIC 33-51-24. THE OPS CHECK WAS GOOD. THE ACFTSDR TRBA2012044002Cap · missingDURING B-INSP FOUND THE EMERGENCY FLOOR LIGHT STRIP MISSING END CAP IN GALLEY AREA. THE ACFT WAS REMOVED FROM SERVICE. FOUND END CAP AND RE-INSTALLED EMERGENCY FLOOR LIGHT END CAP IN GALLEY AREA IAW JIC 25-28-21, RAI 10000. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA2012039001Switch · inoperativeDURING MX INSPECTION, FOUND THE EMERGENCY LIGHTS TOGGLE SWITCH CANNED. THE ACFT WAS REMOVED FROM SERVICE. INSTALLED EMERGENCY LIGHT TOGGLE SWITCH REF CANNED TAG 88210 IAW MM 20-45-11. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR TRBA2012025001Power Supply · failedTHE CREW REPORTED THAT ON POST FLIGHT, FOUND THE EMERGENCY EXIT LIGHTS AT PASSENGER ENTRY DOOR ARE INOPERATIVE. ACFT REMOVED FROM SERVICE. REMOVED AND INSTALLED EMERGENCY LIGHTING POWER SUPPLY IAW JIC33-51-21-RAI-10000. OPS CHECKED GOOD. ACFT RETURNED TO SERSDR TRBA201135403Door · missingON POST FLT INSPECTION, FOUND UPPER LT GEAR DOOR MISSING. INSTALLED LT FOLDABLE MLG DOOR IAW SRM 52-81-00. GEAR SWING PERFORMED, OPS CHECK GOOD. REF JIC 07-11-00, JUP 10000.SDR TRBA201131803Light · inoperativePAX DOOR EMERGENCY LIGHT INOPERATIVE. R & R PAX DOOR LIGHT ASSY IAW 33-51-24-RAI-10000.SDR TRBA201131401Lamp · failedEMERGENCY LIGHT ON THE STAIRS FLICKERS. RE-LAMPED EMERGENCY LIGHT ON PAX/ CREW STAIR IAW MM 33-50-00.SDR TRBA201131105Bulb · inoperativeEMERGENCY FLOOD LIGHT ON THE MAIN CABIN DOOR INOPERATIVE. REPLACED EMERGENCY LIGHT BULB AT PAX DOOR IAW AMM 33-51-24.SDR TRBA201126301Bulb · looseEMERGENCY LIGHT ON THE MAIN CABIN DOOR INOP IS OUT REPEAT WRITE UP. RESECURED LIGHT BULB 33-50-00.SDR TRBA201126303Light · intermittentEMERGENCY EXIT LIGHT IN STAIRS IS OUT. PERFORMED OPS CHECK OF EMERGENCY EXIT LIGHTS IAW JIC 33-50-00, OPT 10000. OPS CHECKED GOOD AND W/C EX335000-OPT-10000.SDR TRBA201126302Light · intermittentEMERGENCY EXIT LIGHT LT SIDE OF ACFT IS OUT. PERFORMED OPS CHECK OF EMERGENCY EXIT LIGHTS IAW JIC 33-50-00, OPT 10000, OPS CHECK GOOD AND W/C EX335000-OPT-10000.SDR TRBA201123502Bulb · looseEMERGENCY LIGHT ON STAIRS IS OUT. RESECURED BULB IAW JIC 33-00-00. OPS CHECKED GOOD.SDR TRBA201122107Lamp · inoperativeAIRSTAIR/ DOOR EMERGENCY LIGHT INOPERATIVE. RELAMPED AIRSTAIR/ DOOR IAW MM 33-50-00.SDR TRBA201121601Battery · faultedEMERGENCY BATTERY CHARGE FAULT IN FLIGHT. R & R EMERGENCY BATTERY IAW W/C EX-243185-RAI-10020-002.SDR TRBA2011090Latch · brokenREAR PANEL EMERGENCY LIGHT PUSH BUTTON LATCH IS BROKEN. R & R SWITCH BASE ON REAR PANEL EMERGENCY LIGHT PUSH BUTTON.SDR TRBA2011040Windshield · crackedF/O WINDSHIELD CRACKED AND MONOFILAMENTS STARTED TO BURNED ON WINDSHIELD. REPLACED F/O WINDSHIELD IAW JIC 56-11-00. LEAK CHECK SATISFACTORY.SDR TRBA2010023SUPGround Wire · failedELECTRICAL SMOKE ODOR IN COCKPIT. R & R GPU GROUND CABLE 440VN IAW JIC NR 24-46-11.SDR TRBA2010023Unknown · odorELECTRICAL SMOKE ODOR IN COCKPIT. AWAITING NRWC FOR FURTHER DETAILS.SDR TRBA2009079Flap System · malfunctionedUPON FLAP RETRACTION DURING CLIMB FLAP ASSY LIGHT ILLUMINATED WITH CAUTION. EMERGENCY DECLARED. RETURN TO DEPARTURE, PERFORMED 0 DEGREE FLAP LANDING. PERFORMED ADJUSTMENT OF RT FLAP POSITION TRANSMITTER IAW MM JIC NR 27-55-71. OPS TEST FOUND OK IAW MM JIC NSDR TRBA2009051SUPWindshield · crackedDURING CLIMB-OUT NOTICED CAPT FRONT WINDSHIELD SHOWING MULTIPLE SPIDER CRACKS ALONG WITH BURN MARKS AROUND ENTIRE WINDSHIELD. REMOVED AND REPLACED CAPT WINDSHIELD AS PER JIC NR 56-11-00-RAI-10000. OPS CHECK AND LEAKS CHECK GOOD.SDR TRBA2009046Fire Detector · false activationAT THE GATE NAC OVHEAT LIGHT ON. AS PER AOM VOL 1 CONDITION LEVER MAX RPW, THEN ENGINE FIRE NR 2 LIGHT ON. FOLLOWED EMERGENCY PROCEDURES CHECK LIST (ENGINE FIRE) CONDITION LEVER FUEL SHUT OFF. PULLED FIRE HANDLE, LIGHT OUT. INSPECTED NR 2 ENGINE AND NACELLSDR TRBA2008040Lamp · failedONE OF THE FLOOR EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED FLOOR EMERGENCY LAMP IAW JIC NR 33-50-00.SDR TRBA2007098Sign · inoperativeSERVICE DOOR EMERGENCY EXIT SIGN INOPERATIVE. RAI SERVICE DOOR EMERGENCY EXIT SIGN IAW JIC 33-51-00. OPT OK IAW JIC 33-50-00.SDR TRBA2007079Indicator · failedDURING T/O ROLL, F/O'S EHSI WENT BLANK. ABORTED TAKEOFF AND RETURNED TO BLOCK. REMOVED AND REPLACED F/O EHSI AND PERFORMED OPT CK IAW JIC NR 34-75-81 AND FOUND SYSTEM WORKING PROPERLY.
Back to N448AM, cancelled Sep 25, 2013