Service difficulty reports · 26
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR CNMA20060021Power Supply · no testDURING SERVICE CHECK, OPERATIONAL CHECK OF EMERGENCY LIGHTS FAILED. TROUBLESHOT TO EMERGENCY BATTERIES TESTED BAD. REMOVED AND REPLACED EMERGENCY BATTERY PACK AND CHARGER ZONE A AND REMOVED AND REPLACED BATTERY PACK AND CHARGER ZONE B. PRECAUTIONARY REMOVEDSDR CNMA20060020Power Supply · inoperativeEMERG LIGHT TEST FAILED AT PRE-FLIGHT. T/S FOUND EMERGENCY LIGHT AT THE NR 4 DOORS INOP. REMOVED AND REPLACED BATTERY POWER SUPPLY AT THE 4 DOORS. OPS CHECK GOOD IAW 33-51.SDR CNMA20060017Connector · corrodedON TAKEOFF ENG 2 & 3 WOULD NOT MAKE MAX TAKEOFF THRUST. ENG FAIL LIGHT CAME ON AT APPROX 110 KTS ABORTED TAKEOFF. ALL ENG N1 INDICATIONS WERE WITHIN .6 PERCENT. NO ENG ROLLED BACK. FOUND NR 3 ENG N1 SPD SENSOR ERRRATIC / UNRELIABLE. REMOVED AND REPLACED N