N552UA, cancelled Feb 22, 2023
Service difficulty reports · 271
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N552UA' AND deregistration_id = 'N552UA-2023-02-22' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N552UA' AND deregistration_id = 'N552UA-2023-02-22' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014090992104Mount · gougedNUMBER 2 ENG FWD MOUNT INBD AFT ATTACH AREA HAS GOUGE APPROX 250 INCHES FROM BOLT HOLE FLANGE. STRUT FITTING, UPPER MOUNT, HAND BLENDED GOUGE IAW SRM 54-51-09. EDDY CURRENT BY INSPECTION WITH NO DEFECTS FOUND. ROTO PEENED IAW GPM 1-0-01-076. NOTE ORIGINAL SDR CALA2014082892035Floorbeam · crackedMAIN CABIN FLOORBEAM UPPER CHORD HAS A CRACK AT THE RADIUS, BS 660 LBL 46. REPAIRED MAIN CABIN FLOORBEAM UPPER CHORD IAW ECRA 5310-06181.SDR CALA2014082692024Skin · crackedLOWER EXT FUSELAGE SKIN BS 760 LBL 12, SKIN CRACKED 2 PLACES. REMOVED DAMAGE, FABRICATED & INSTALLED DOUBLER REPAIR IAW SRM 53-00-01 REPAIR 3.SDR CALA2014082692022Frame · corrodedAFT PIT BS 1480 STRINGER 27R CORROSION ON FRAME. REMOVED DAMAGE, FABRICATED & INSTALLED REPAIR PARTS IAW SRM 51-30-01.SDR CALA2014081391966Crease Beam · corrodedRIGHT CABIN CREASE BEAM INBD CHORD CORROSION. REMOVED DAMAGE, FABRICATED & INSTALLED REPAIR PARTS IAW SRM 51-40-05.SDR CALA2014081391965Doubler · corrodedAFT CABIN BS 1680 - 1686 RBL 50 - 52 PRESS DECK DOUBLER UPPER SURFACE CORRODED. REMOVED DAMAGE. FABRICATED & INSTALLED REPAIR PARTS IAW SRM 53-60-51 REPAIR 10. REPAIR WAS REMOVED & REINSTALLED FOR HFEC & DVI IAW SRM 53-60-51 REPAIR 10 STEPS 4D, E & F.SDR CALA2014060291197Unknown · malfunctionedFUEL IMBALANCE, LT WING 1200 LBS HIGHER THAN RT AFTER 1:20 OF FLIGHT. ACCOMPLISHED STATIC LEAK CHECK WITH 3500 LBS OF FUEL IN BOTH WINGS, NO TRANSFER NOTED. ACCOMPLISHED CHECK WITH WING PUMPS ON WITH NO TRANSFER NOTED. SUSPECT POSSIBLE LEAK FROM RT TANK TO SDR CALA2014033190733Engine · making metalFOUND METAL ON MAIN CHIP, MAIN GEARBOX CHIP & ANGLE GEARBOX CHIP. REPLACED NR 1 ENG IAW MM 71-00-02.SDR CALA2014030790551Control Unit · malfunctionedRT HYD ELEC PUMP EICAS MESSAGE, LOW PRESS LIGHT ILLUMINATED. RAN PUMP ON GND APPROXIMATELY 60 MINUTES NO FAULTS. INSPECTED ALL FILTER DELTA INDICATOR, ALL GOOD. INSPECTED PUMP CANNON PLUG FOR SPARKING, NO DEFECTS FOUND. REPLACED RT ELEC PUMP ELCU IAW MM 29SDR CALA2013122693912Unknown · malfunctionedIN UNDER 2 HR FUEL IN LT TANK UP BY 1500 LBS. IAW FUEL IMBALANCE, FUEL EVEN USING CTR PUMPS. 1:50 AFTER TANK TO ENG LT TANK 1500 LBS ABOVE RT. LT ENG BURN 100 PPH MORE THAN RT ENG IAW SEQ 4502010, 4502009, 4502007 & 4502002. COMPLETED FUEL TRANSFERS WAS UNASDR CALA2013121893789Generator · leakingAPU NO START AFTER LANDING FAULT INDICATION. FOUND LOW OIL QTY, ECU SHOWED LOW OIL PRESS. CLEARED ECU, SERVICED & RAN APU, FOUND GEN CASE LEAKING OIL, NEEDS GENERATOR. REPLACED APU GEN IAW MM 24-21-01, OPERATIONS & LEAK CHECKED GOOD.SDR CALA2013120593500Unknown · malfunctionedWHEN SETTING PARKING BRAKE, NO PARK BRAKE LIGHT & NO EICAS PARKING BRAKE.SDR CALA2013121193589Vsi · inoperativeLIGHT ON FIRST OFFICER`S VSI OUT. REPLACED FIRST OFFICER`S VSI INDICATOR IAW MM, CHECKED GOOD.SDR CALA2013110192567Hydraulic Line · leakingHYD LEAK RT MLG STRUT AREA. REPLACED HYD LINE IAW IPC 32-41-51-025, ITEM 265 (170-5876) & BLEED RT MLG TRUCK POSITIONER ACTUATOR IAW AMM, NO LEAKS. SERVICED HYD RESERVOIRS TO FULL.SDR CALA2013102992484Duct · contaminatedLOOSE OBJECT IN DUCTING FWD OF FIRST OFFICER'S INSTRUMENT PANEL. NOISE IN CKPT AIR DUCT. REMOVED CLAMPS ON CKPT AC DUCT BELOW FLOOR IN FWD EE BAY & FOUND WASHER & BROKEN TIE WRAP. REMOVED ITEMS & ASSEMBLED DUCTING, NOISE WENT AWAY.SDR CALA2013102292251Battery · dischargedMAIN SHIP'S BATTERY IS DEAD. REPLACED BATTERY IAW AMM.SDR CALA2013101692117Seal · leakingNR 1 ENG OIL CONSUMPTION HAS REACHED AMBER LEVEL. FOUND STARTER DRIVE PAD SEAL LEAKING. REPLACED PAD SEAL IAW 72-61-02, NO LEAKS NOTED. REPLACED NR 1 ENG STARTER PRECAUTIONARY.SDR CALA2013101191973Eec · failedLEFT ENGINE EEC MALFUNCTIONED. REPLACED EEC IAW MM 73-21-04 AND ACCOMPLISHED NR 1 ENGINE RUN. NO STATUS MESSAGE ON SHUTDOWN.SDR CALA2013100891831Cover · damagedEMERGENCY FLOOR LIGHT COVER IS DAMAGED AT ROW 29ABC. REPLACED & SECURED COVER, OPERATION CHECKED GOOD.SDR CALA2013100891830Cover · damagedEMERGENCY FLOOR LIGHT COVER IS DAMAGED FROM ROWS 37ABC- 40ABC. REPLACED LIGHT COVER.SDR CALA2013100891829Cover · damagedEMERGENCY FLOOR LIGHT COVER IS DAMAGED FROM ROWS 8ABC - 14ABC. REPLACED LIGHT COVER.SDR CALA2013100791777Wire · chafedWHILE ACCOMPLISHING LM7397, FOUND 1 BROKEN & 1 CHAFFED WIRE ON HARNESS TO PMA STATOR. ON NR 1 ENG REPLACED WIRE FROM CONNECTOR D4856 OF NR 1 EEC TO CONNECTOR D4858 OF THE PMA IAW WDM.SDR CALA2013100791778Eec · faultyLT ENG EEC REPLACEMENT DUE TO REPEAT LT ENG REV CONTROL STATUS MESSAGE WITH EPCS PAGE MESSAGE 274-18. REPLACED EEC MR73237 DASH NR 96 IAW AMM 73-21-04 401. REPLACED NR 1 EEC IAW MM 73 -21-04. CYCLED REVERSER SEVERAL TIMES NO FAULTS OR MESSAGE.SDR UALA2013070504700Actuator · leakingLEFT NOSE STEERING CYLINDER ACTUATOR HAS FLUID LEAKING FROM ROD END, ONE DROP PER MINUTE.SDR UALA2013070104588Signal Cond Unit · faultyRIGHT ENGINE VIBRATION INDICATION READS HIGH, LOW, ZERO, BLANK, FLUCTUATES OR INOPERATIVE. NO ABNORMAL VIBRATION PERCEIVED. OTHER ENGINE PARAMETERS NORMAL. REPLACED AIRBORNE VIBRATION MONITOR SIGNAL CONDITIONER IAW AMM.SDR UALA2013070104587Lanyard · unsecureLANYARD HANGING FROM SLIDE PACK AT DOOR 2L. STOWED LANYARD AT SLIDE PACK AT DOOR 2L.SDR UALA2013062704497Module · faultyFUEL CONTROL PANEL ASSY SWITCH S5 FAILED. CMM 28-41-71, PG 1005, FUNCTIONAL TEST STAT 48 AND 51. RESISTANCE TOO HIGH. REF COA 507225, STEP 1A2-4. R & R S5 SWITCH MASTER MODULE. ACCOMPLISHED FUNCTIONAL TEST IAW CMM, CHECKS GOOD.SDR UALA2013062004308Panel · weakF/O RADIO VOLUME WEAK ALL CHANNELS. R & R F/O AUDIO CONTROL PANEL IAW AMM, OPS CHECK NORMAL.SDR UALA2013061704196Strap · out of positionDOOR 2L DOES NOT CLOSE PROPERLY. FOUND "D" RING STRAP HANGING DOWN. REPOSITIONED STRAP IAW AMM 25-60-00. DOOR CLOSES PROPERLY.SDR UALA2013061704195Strap · looseDOOR 2L SLIDE RESTRAINING STRAP CAME LOOSE. COULD NOT ARM DOOR. RE-ROUTED SLIDE STATIC LINE.SDR UALA2013061704182Unknown · leakingNR 2 ENG HAS EXCESSIVE OIL DRIPPING FROM FAN COWL. PERFORMED AMM 71-71-00 INSP FOR LEAKS FOUND ACCUMULATION JUST AFT OF TOWER SHAFT. SUSPECT BREATHER AIR BUILD-UP, NO LEAKS FOUND.SDR UALA2013061304094Pushrod · wornLT INBD AFT FLAP, CENTER UPPER AND LOWER PUSH ROD ENDS WORN. REPLACED ROD AND HARDWARE. VERIFIED NEW ROD AND HARDWARE ARE IN PLACE IAW IPC 27-51-02-010C.SDR UALA2013061304093Bolt · wornLT INBD AFT FLAP, INSTALLATION BOLTS FOR AFT FLAP PUSH RODS AND SUPPORT TRACKS ARE WORN REPLACE AS REQUIRED. REPLACED HARDWARE AND TRACK. VERIFIED NEW HARDWARE AND SUPPORT TRACKS INSTALLED IAW AMM AND IPC 27-51-02-010C.SDR UALA2013060603930Flap Track · wornFOUR LEFT OTBD AFT FLAP SUPPORT TRACKS WORN FROM ROLLERS AND BEARINGS LOOSE AND ATTACHING HARDWARE WORN. REPLACED SUPPORT TRACKS AND ATTACHING HARDWARE.SDR UALA2013060603929Bolt · scoredLEFT AILERON ATTACH BOLTS SCORED. REPLACED DAMAGED BOLTS IAW MM.SDR UALA2013052003470Pressure Switch · failedLEFT ENGINE HYDRAULIC PRESSURE LIGHT DOES NOT ILLUMINATE WITH ENGINE OFF. REPLACED EDP HYDRAULIC PUMP PRESSURE SWITCH IAW AMM 29-11-17. MOTORED ENGINE AND PUMP AND INDICATOR LIGHT WORKS NORMAL.SDR UALA2013052003469Indicator · damagedLEFT MAIN FUEL INDICATOR HAS MISSING SEGMENTS ON THE REFUELING PANEL. REPLACED INDICATOR, TEST OK.SDR UALA2013050703185Computer · failedBURNING ODOR IN COCKPIT & FIRST OFFICER`S EADI IS BLANK. FOUND EHSI BURNED AND REPLACED RIGHT EHSI AND SYMBOL GENERATOR AGAIN. RESTORED OPERATIONS.SDR UALA2013050303119Frame · dentedFWD CARGO BAY FRAME DENTED BS 640 S23L. CUTOUT DAMAGED SECTION OF FLANGE AND FABRICATED A REPAIR ANGLE AND INSTALLED PER SRM 53-00 -07, REPAIR 5. MAJOR REPAIR.SDR UALA2013050303117Frame · dentedFRAME DENTED BS 1420, S26L. CUT OUT DAMAGED SECTION OF FLANGE AND FABRICATED A J-ANGLE REPAIR PER SRM 53-00-07, REPAIR 5. PER SRM 53-00-07, REPAIR 5 , TABLE II, ZONE 3. MAJOR REPAIR.SDR UALA2013050303118Frame · dentedAFT CARGO BAY FRAME BS 1480, S26L DENTED. CUT OUT DAMAGED SECTION OF FLANGE & FABRICATED A 'J-ANGLE' REPAIR AND INSTALLED PER SRM 53- 00-07, REPAIR 5 ON NON ROUTINE 44405. PER SRM 53-00-07, REPAIR 5, TABLE II, ZONE 1. MAJOR REPAIR.SDR UALA2013050303116Frame · damagedFORWARD CARGO BAY FRAME DENTED BS 620 S24L. CUT OUT DAMAGED SECTION OF FLANGE AND FABRICATED A REPAIR ANGLE AND INSTALLED PER SRM 53-00 -07, REPAIR 5 TABLE II, ZONE 1. MAJOR REPAIR.SDR UALA2013042502887Actuator · failedLEFT WING LEADING EDGE SLAT ROTARY ACTUATORS NR 2 AND NR 8 HAVE OVERLOAD SPRINGS BAD. REMOVED AND REPLACED NR 2 ROTARY ACTUATOR IAW MM 27-81-18.SDR UALA2013042502886Fseu · no testNR 3 FLAP/SLAT ELECTRICAL UNIT BITE TEST FAILED. REPLACED NR 3 FSEU.SDR UALA2013041102490Computer · malfunctionedAUTOPILOT DISC LIGHT ON & EICAS MESSAGE 'AUTOPILOT DISC' DISPLAYED WITH 2 AUTOPILOT SYSTEM ENGAGED IN COMMAND. AT CRUISE 380 M.80 CTR A-P DISCONNECTED. TRIMMED AND TRIED AGAIN, NO GO, LEFT AND RIGHT AUTOPILOT SYS OK. FOUND FAULT FCC-C. REPLACED CENTER FCCSDR UALA2013040402219Pressure Switch · faultyLEFT ELECTRIC HYDRAULIC PUMP PRESSURE LIGHT DOES NOT ILLUMINATE WITH SWITCH OFF. PUMP OPERATES NORMALLY. PUMP OPERATES NORMALLY, ASSOCIATED LOW SYSTEM PRESSURE LIGHT OPERATES NORMALLY, REPLACED PRESSURE SWITCH. OPS CHECKED NORMAL, NO LEAKS.SDR UALA2013032701951Warning Message · false activationFLAP/SLAT STATUS MESSAGE DISPLAYED AND WILL NOT ERASE. RESET FLAP UNIT BITE, SYSTEM OPERATES NORMAL.SDR UALA2013032601911Lens · crackedFOUND EMERGENCY LIGHT LENS CRACK AFT OF LEFT WING. REPLACED LENS. OPS CHECKED OKAY.SDR UALA2013032501876Lamp · inoperativeFOUND LT WING OFF WING SLIDE EMERGENCY LIGHT INOP. RELAMPED PER MM, OPS CHECKED NORMALSDR UALA2013032501875Fcu · faultyREPLACED APU FLOW SENSING MODULE REF DF676 APU AUTO SHUTDOWN. REPLACED FLOW SENSING MODULE, NO HELP ACC. APU DEEP BITE TEST FAULTS SHOW DELTA P, FUEL CONTROL UNIT, DE-OILER SOLENOID, HOT SENSOR AND P2 SENSOR
Back to N552UA, cancelled Feb 22, 2023