Service difficulty reports · 4
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR 96ZZZX5024Breaker · failedCOMM 2 CIRCUIT BREAKER OPENED DURING FLIGHT AND WOULD NOT RESET. CIRCUIT BREAKER WAS REPLACED WITH NEW BREAKER.SDR 95ZZZX3655Battery · cover meltedBATTERY PACK COVER MELTED AROUND TERMINAL POSTS. THIS CONDITION CAUSED BY LOOSE/HIGH RESISTANCE CONNECTION BETWEEN TERMINAL POSTS AND CELL TABS. SUBMITTER RECOMMENDS MANUFACTURER USE THICKER MATERIAL FOR COVER PERHAPS OF A PHENOLIC AS THEY USED TO DO IN PREVSDR 95ZZZX3434Quadrant · corrodedDURING A VISUAL INSPECTION OF THE ELEVATOR QUADRANT, WHILE POWDER WAS NOTED AROUND THE UPPER CONTROL CABLE ATTACH POINT BARREL. REMOVAL OF BOTH CABLES FOUND DEEP CORROSION IN THE CONTROL CABLE ATTACH POINTS ON THE QUADRANT. THE 2400-HOUR, 24- AND 48-MONTH INSDR 95ZZZX3099Elev Quadrant · corrodedDURING A VISUAL INSPECTION OF THE ELEVATOR QUADRANT, WHITE POWDER WAS NOTED AROUND THE UPPER CONTROL CABLE ATTACH POINT BARREL. REMOVAL OF BOTH CABLES FOUND DEEP CORROSION IN THE CONTROL CABLE ATTACH POINTS ON THE QUADRANT, THE 2400-HOUR 24 AND 48-MONTH INSPE