N603GC

Cancelled 2015

Deregistered aircraft · 1974 Mcdonnell Douglas DC-10-30F · GE CF6-50 series

Cancelled
May 19, 2015
Status when cancelled
Registration expired, pending cancellation
Serial number
47922
Year built
1974
Type
Fixed wing multi engine
Engine
Turbo-fan
Airworthiness
Standard, transport
Airworthiness date
May 22, 1996
Certificate issued
December 11, 1997
Last registry action
July 15, 2008
Mode S code
A7D2FD
Owner when cancelled
Gemini Leasing Inc
Location
Dulles, VA
Owner type
Corporation

From the FAA registry file of October 29, 2026, cancelled registrations. Owners’ street addresses are left out. The Mode S code belongs to the N-number, not the airframe.

Service difficulty reports · 6

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.

SDR G6OA019Exhaust Fairing · missingON PREFLIGHT INSPECTION, GROUND MAINTENANCE NOTED THE NR 1 ENGINE AFT CENTER BODY EXHAUST NOZZLE FAIRING MISSING. GROUND MAINTENANCE REPLACED THE NR 1 ENGINE AFT CENTER BODY EXHAUST NOZZLE PER MM 78-11-02. AIRCRAFT RETURNED TO SERVICE. (M)Mar 29, 1998 · N603GC · Doug DC1030F · Engine Collector/Tailpipe/NozzleSDR G6OA013Battery · dischargedWHILE ACCOMPLISHING GROUND CHECKS, THE FLIGHT CREW FOUND EMERGENCY LIGHTS WOULD NOT TEST. GROUND MAINTENANCE INVESTIGATED AND DETERMINED THE BATTERY POWER SUPPLY WAS INOPERATIVE. THE BATTERY POWER SUPPLY WAS REPLACED IAW DC-10 MM 33-51-01. (X)Aug 5, 1997 · N603GC · Doug DC1030F · Emergency LightingSDR G6OA011Switch · missingDURING C-CHECK MAINTENANCE, A PASSENGER OXYGEN CHECK WAS ACCOMPLISHED. THE LAVATORY OXYGEN MASK FAILED TO DEPLOY AT 14,440 FEET ALTITUDE. INVESTIGATION REVEALED THE ANEROID SWITCH HAD NOT BEEN INSTALLED. IT WAS DETERMINED THE ANEROID SWITCH AND ITS ASSOCIATEJun 27, 1997 · N603GC · Doug DC1030F · Passenger Oxygen SystemSDR SCNA96247Smoke Detector · inoperativeDURING LINE CHECK, NUMBER 3 LOWER AFT CARGO SMOKE DETECTOR DID NOT TEST. RELAMPED AND TESTED NORMAL.Sep 7, 1996 · N603GC · Doug DC1030F · Smoke DetectionSDR SCNA96240Connectors · dirtyNR 2 FIRE LOOP-A WAS FLASHING DURING DESCENT AND APPROACH. CLEANED CONNECTOR, CHECKED LOOP-A SYSTEM FOR SHORTS. NO SHORTS FOUND, OPS CHECKED GOOD.Aug 24, 1996 · N603GC · Doug DC1030F · Fire DetectionSDR SCNA96214O-Ring · cutDURING FLIGHT NOTICED THAT THE NUMBER 2 ENGINE OIL QUANTITY WAS AT 0 AND THE OIL PRESSURE WAS FLUCTUATING BETWEEN 20 PSI AND 40 PSI. AFTER MONITORING, THE OIL PRESSURE DROPPED BELOW RED LINE AND NUMBER 2 OIL PRESSURE LIGHT ILLUMINATED. NUMBER 2 ENGINE WAS SHAug 7, 1996 · N603GC · Doug DC1030F · Hydraulic Pump (Electric/Engine), Main