SDR TWRA97129Wire · brokenDURING DAILY SERVICE, FOUND EVAC LIGHT 28C INOPERATIVE. REPAIRED BROKEN WIRE. OPS CHECKED OK PER MM 33-51-00. (X)May 29, 1997 · N604FF · Boeing 747121 · Light System WiringSDR TWRA97128Fuse · blownDURING DAILY SERVICE, FOUND ALL EVAC LIGHTS AT C-ZONE WENT OUT (LEFT SIDE ONLY). REPLACED FUSE. OPS CHECKED NORMAL PER MM 33-51-00. (X)May 29, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA97127Fuse · blownDURING DAILY SERVICE, FOUND ENTIRE E-ZONE EVAC LIGHTS INOPERATIVE. REPLACED FUSE AT CHARGER. OPS CHECKED OK PER MM 33-51-00, PAGE 501. (X)May 29, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA97126Fuse · blownDURING DAILY SERVICE, FOUND C-ZONE LEFT SIDE EVAC LIGHTS INOPERABLE. FOUND 5-AMP FUSE BLOWN. REPLACED FUSE. OPS CHECKED OK PER MM 33-51-00. (X)May 29, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA97125Wire · brokenDURING DAILY SERVICE, FOUND 26K EVAC LIGHT INOPERATIVE. REPAIRED BROKEN WIRE. OPS CK OK PER MM 33-51-00. (X)May 28, 1997 · N604FF · Boeing 747121 · Light System WiringSDR TWRA97124Battery Pack · dischargedDURING DAILY CHECK, FOUND ENTIRE 'E' ZONE EGRESS LIGHTS INOP AFTER 2-3 MINUTES. REPLACED 'E' ZONE EGRESS BATTERY PACK. LIGHTS CHECKED NORMAL PER MM 33-51-00. (M)May 26, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA97118Fuse · failedDURING DAILY CHECK, FOUND C-ZONE LEFT EVAC LIGHTS INOPERABLE. REMOVED AND REPLACED FUSE ON CHARGER. OPS CKD OK PER MM 33-51-00. (X)May 23, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA97117Fuse · failedDURING DAILY CHECK, FOUND L3 DOOR JUMP SEAT EVAC LIGHT INOPERABLE. REMOVED AND REPLACED FUSE ON CHARGER. OPS CKD OK PER MM 33-51-00. (X)May 23, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA97116Fuse · failedDURING DAILY CHECK FOUND 'E' ZONE BOTH SIDES OF EVAC LIGHTS ARE INOPERABLE. REMOVED AND REPLACED FUSE ON CHARGER. OPS CKD OK PER MM 33-51-00. (X)May 23, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA97115Fuse · failedDURING DAILY CHECK, FOUND FWD OF AFT LAV CROSSWAY EVAC LIGHTS ARE INOPERABLE. FOUND BLOWN FUSE ON CHARGER. REMOVED AND REPLACED FUSE. OPS CKD OK PER MM 33-51-00. (X)May 23, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA97109Charger · defectiveDURING DAILY SERVICE AT JFK, ALL EVAC LIGHTS ON LEFT SIDE OF 'C' ZONE FOUND INOP. REPLACED BATTERY CHARGER. OPS CHECK OK PER MM 33-51-00. (M)May 15, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA97105Fuse · failedJFK - DURING DAILY SERVICE, FOUND E-ZONE EMERGENCY EVAC LIGHT INOPERATIVE. FOUND FUSE N/G ON THE CHARGER, REPLACED FUSE AND OPS CHKS OK PER MM 33-51-00. REFERENCE: OPERATOR CONTROL NR 97ZZZX____. (X)May 14, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR 97ZZZX2599Wire · brokenJFK - DURING DAILY SERVICE, FOUND E-ZONE EVAC LIGHT INOPERATIVE AT SEAT 64E. FOUND WIRE GOING TO LIGHT ASSY BROKEN. REPAIRED WIRE, OPS CHKS OK PER MM 33-51-00. REFERENCE: OPERATOR CONTROL NR TWRA97105.May 14, 1997 · N604FF · Boeing 747121 · Light System WiringSDR TWRA97101Connector · looseDURING DAILY SERVICE, FOUND C-ZONE LEFT SIDE EVAC LIGHTS AT SEATS INOP. RESPLICED FEEDER CONNECTION AT 32ABC, OPS CHECKS OK. (M)May 9, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA9780Fuel Valve · leakingNR 3 MAIN FULE TANK INDICATES AN INCREASE OF 4200 LBS PER HOUR. REPLACED NR 3 MAIN FUEL VALVE AND LEFT PUMP DISCHARGE CHECK VALVE. REPLACED I/B FILL VALVE AND FLAPPER IN I/B PUMP CHECK VALVE. (M)May 6, 1997 · N604FF · Boeing 747121 · Aircraft Fuel Distribution SystemSDR TWRA9785Wire · brokenDURING DAILY SERVICE, 'E' ZONE EVAC LGHT INOP ON LEFT AND RIGHT SIDE. REPAIRED BROKEN WIRE AT POWER SUPPLY. OPS CHECKS OK PER MM 33-51-00. (M)May 5, 1997 · N604FF · Boeing 747121 · Light System WiringSDR TWRA9792Battery · dischargedA ZONE EVAC LIGHTS INOP ON ALL SEAT ARM RESTS. SPIRAL STAIRWAY EVAC LIGHTS. U/D LAV/CREW DOOR AREA, EXIT SIGNS INOP. REPLACED BATTERY PACK, OPS CHECK OK 33-51-00. (M)May 2, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA9781Hf Coupler · defectiveIN FLIGHT, FOUND THAT NR 1 HF CAUSES FIRE WARNING BELLS FOR LOWER CARGO, CAPTAINS CAS FLAG COMES IN TO VIEW ON A/S INDICATOR AND F/O'S ALTIMETER GOES TO STANDBY. REPLACED NR 1 HF COUPLER. OPS CHECK OK PER MM 23-11-00 PAGE 501. (M)Apr 22, 1997 · N604FF · Boeing 747121 · HF Communications SystemSDR TWRA9769Battery Charger · inoperativeFOUND DURING DAILY CHECK, UPPER DECK CREW SERVICE DOOR SILL LIGHTS ARE INOP. FOUND BATTERY UNIT NOT CHARGING. REMOVED AND REPLACED BATTERY UNIT AND CHARGER. OPS CHECKS OK. EMERGENCY LIGHT AT SEAT 16HJK INOP. FOUND BROKEN WIRES, SPLICED WIRES. OPS CHECK Apr 12, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR 97ZZZM545Battery Charger · dischargedFOUND DURING DAILY CHECK, UPPER DECK CREW SERVICE DOOR SILL LIGHTS ARE INOP. FOUND BATTERY UNIT NOT CHARGING. REMOVED AND REPLACED BATTERY UNIT AND CHARGER. OPS CHECKS OK. EMERGENCY LIGHT AT SEAT 16HJK INOP. FOUND BROKEN WIRES, SPLICED WIRES. OPS CHECK Apr 12, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA9764Battery Pack · dischargedDURING DAILY SERVICE AT JFK, FOUND 'E' ZONE EGRESS LIGHTS BATTERY PACK WEAK. REPLACED 'E' ZONE' BATTERY PACK. (M)Apr 7, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA9753Battery Pack · dischargedDURING DAILY SERVICE, FOUND LEFT SIDE OVERWING EMERGENCY LIGHTS INOP. DURING DAILY SERVICE, FOUND ENTIRE E-ZONE EVAC LIGHTS INOP. REPLACED BATTERY PACK, OPS CHECK OK. REPLACED BATTERY CHARGER, OPS CHECK OK. (M)Apr 4, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR 97ZZZM528Battery Charger · inoperativeDURING DAILY SERVICE, FOUND LEFT SIDE OVERWING EMERGENCY LIGHTS INOP. DURING DAILY SERVICE, FOUND ENTIRE E-ZONE EVAC LIGHTS INOP. REPLACED BATTERY PACK, OPS CHECK OK. REPLACED BATTERY CHARGER, OPS CHECK OK. REFERENCE TWRA9753.Apr 4, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA9751Connector · looseFROM NON-ROUTINE WORK CARD WHILE UNDER SERVICE AT JFK, FOUND THE UPPER DECK CREW DOOR EXIT SIGN INOP AND LEFT SIDE OVERWING EMERGENCY LIGHT INOP. FOUND CONNECTOR DISCONNECTED, RECONNECTED. OPS OK PER MM 33-50-00. (M)Apr 3, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA9752Battery Pack · dischargedFROM NON-ROUTINE ITEM, EVAC EXIT LIGHTS OUT ON U/D STAIRS/LAV AND CREW U/D EMER EXIT DOOR. REPLACED CREW BATTERY PACK, OPS CHECK OK PER MM 33-50-00. RECONNECTED BROKEN WIRE FOR U/D STAIRS/LAV. OPS CHECK OK PER 33-50-00. (M)Apr 2, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA9762Connector · looseDURING DAILY SERVICE AT JFK, FOUND UPPER DECK CREW DOOR EXIT SIGN INOP. FOUND CONNECTOR DISCONNECTED. RECONNECTED AND OPS CHECKS OK. (M)Apr 1, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWA9743Fire Detector · failedDURING TAKEOFF, NR 4 ENGINE NACELLE FIRE DETECTION AND FAULT LIGHTS ILLUMINATED WITH A-LOOP NACELLE TEMP INDICATOR OSCILLATION TO F-BAND. B-LOOP SELECTED AND TESTED, LIGHTS ILLUMINATED BUT A-NACELLE TEMP INDICATOR OSCILLATION CONTINUED DURING CRUISE. REPLACEMar 29, 1997 · N604FF · Boeing 747121 · Fire DetectionSDR TWRA9745Battery Supply · discharged5R M.E.D. EMER LT ON SIDEWALL IS INOP, DURING MAINT. 5L M.E.D. EMER LT ON SIDEWALL IS INOP, DURING MAINT. E-ZONE ALL EMER LTS ON SIDE OF SEATS INOP, DURING MAINT. REMOVED AND REPLACED ALL BATTERY SUPPLIES, OPS CHKS OK. REFERENCE: OPERATOR CONTROL NRS 97ZZMar 28, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR 97ZZZX1665Battery Supply · discharged5R M.E.D. EMER LT ON SIDEWALL IS INOP, DURING MAINT. 5L M.E.D. EMER LT ON SIDEWALL IS INOP, DURING MAINT. E-ZONE ALL EMER LTS ON SIDE OF SEATS INOP, DURING MAINT. REMOVED AND REPLACED ALL BATTERY SUPPLIES, OPS CHKS OK. REFERENCE: OPERATOR CONTROL NRS TWRAMar 28, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR 97ZZZX1664Battery Supply · discharged5R M.E.D. EMER LT ON SIDEWALL IS INOP, DURING MAINT. 5L M.E.D. EMER LT ON SIDEWALL IS INOP, DURING MAINT. E-ZONE ALL EMER LTS ON SIDE OF SEATS INOP, DURING MAINT. REMOVED AND REPLACED ALL BATTERY SUPPLIES, OPS CHKS OK. REFERENCE: OPERATOR CONTROL NRS TWRAMar 28, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA9742Battery Pack · disconnectedAREA OF SEAT 36HJK CEILING EMERGENCY LIGHT INOPERABLE. C-ZONE, SEATS 43ABC TO SEATS 45ABC EGRESS LIGHTS INOPERABLE. FOUND CEILING LIGHTS BATTERY PACK DISCONNECTED, RECONNECTED. OPS CHECKS OK. FOUND BROKEN WIRE AT SEAT 45ABC, SPLICED WIRE AND OPS CHECKS OK.Mar 27, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR 97ZZZX1660Wire · brokenAREA OF SEAT 36HJK CEILING EMERGENCY LIGHT INOPERABLE. C-ZONE, SEATS 43ABC TO SEATS 45ABC EGRESS LIGHTS INOPERABLE. FOUND CEILING LIGHTS BATTERY PACK DISCONNECTED, RECONNECTED. OPS CHECKS OK. FOUND BROKEN WIRE AT SEAT 45ABC, SPLICED WIRE AND OPS CHECKS OK.Mar 27, 1997 · N604FF · Boeing 747121 · Light System WiringSDR TWRA9738Wire · broken'A' ZONE SEATS 4 AC TO 7AC EGRESS LIGHTS INOP. REPAIRED BROKEN WIRE AT SEAT 5AC, OPS OK. (M)Mar 20, 1997 · N604FF · Boeing 747121 · Light System WiringSDR TWRA9733Lights · inoperativeEMERGENCY LIGHTS INOP AT ROW 16 ABC. REINSTALL MISSING EMERGENCY LIGHTS AND EGRESS PACKS. (M)Mar 14, 1997 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA9732Wire · brokenU/D FORWARD OF UPPER DECK GALLEY, EXIT SIGN EVAC LIGHT INOP. FOUND BROKEN SPLICE AT FOWARD U/D GALLEY. REPAIRED WIRE AND OPS CHECKED OK PER MM 33-51-00. (M)Mar 9, 1997 · N604FF · Boeing 747121 · Light System WiringSDR TWRA96282Light · inoperativeDURING DAILY CHECK, FOUND NR 4 RIGHT OVERWING EMERGENCY LIGHT FWD LIGHT INOP. REMOVED AND REPLACED LIGHT ASSY. OPS CHECKED NORMAL PER MM 33-51-00. (M)Aug 13, 1996 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA96268Slide Raft · deployedDURING B-CHECK, FOUND L2 DOOR WAS OPENED AFTER ARMING. SLIDE PARTIALLY DEPLOYED AND DOOR ASSIST BOTTLE FULLY DISCHARGED. REMOVED AND REPLACED ESCAPE SLIDE RAFT AND ACCESS ASSIST DOOR BOTTLE ON L2 DOOR AS PER MM 25-69-00. OPERATION CHECK NORMAL. (M)Aug 10, 1996 · N604FF · Boeing 747121 · Life RaftSDR TWRA96202Bulb · failedDURING DAILY CHECK, FOUND EVAC OVERWING LEFT SIDE AND RIGHT SIDE. FIRST LIGHT FROM BOTTOM INOP. RELAMPED, OPS CHECK OK PER MM 33-51-00. (M)Jul 24, 1996 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA96167Bulb · failedDURING DAILY CHECK, FOUND EMERGENCY LIGHTS AT5R DOOR THRESHOLD BOTH INOP. RELAMPED, OPS CHECK NORMAL PER MM 33-51-00. (M)Jul 14, 1996 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA96112Wire · looseDURING DAILY CHECK, FOUND EVAC LIGHTS INOP, MOUNTED ON SEAT SIDE PANEL BETWEEN 41H AND 35H. FOUND LOOSE WIRE, SECURED WIRE ON SEATS BETWEEN 41H AND 35H. OPS CHECK OK PER MM 33-51-00. (M)Jul 5, 1996 · N604FF · Boeing 747121 · Light System WiringSDR TWRA9654Sign · brokenDURING DAILY SERVICE, FOUND 5R MED EXIT LIGHT INOPERATIVE.REPLACED BROKEN EXIT SIGN.(M)Jun 24, 1996 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA9641Connector · looseCREW REPORTED UPPER DECK SMOKE ALARM SOUNDS INTERMITTENTLY WITH NO INDICATION OF SMOKE PRESENT. DURING TROUBLESHOOTING, MAINTENANCE FOUND LOOSE CANNON PLUG CONNECTOR AT DETECTOR. SECURED CONNECTOR, OK. (M)Jun 13, 1996 · N604FF · Boeing 747121 · Smoke DetectionSDR TWRA9628Engine · failedDURING CRUISE, NR 1 ENGINE HAD A STEADY STATE STALL AT FLT LEVEL 350 FEET, THRUST WAS REDUCED AND STABILIZED, THEN PUSHED THROTTLE TO 1.36 EPR WHEN ENGINE STALLED AGAIN. ENGINE POWER WAS MAINTAINED AT IDLE FOR REMAINDER OF FLT. AIRCRAFT DIVERTED TO MANCHESTEMay 13, 1996 · N604FF · Boeing 747121 · Engine (Turbine/Turboprop)SDR TWRA9626Turbine · failedAT 13,000 FEET AFTER TAKEOFF LOUD BOOM WAS HEARD AND CONFIRMED ENGINE ON NR 3 ENGINE. AFTER RETURN TO JED INITIAL INSPECTION FOUND METAL IN TAILPIPE. BORESCOPE INSPECTION FOUND SECOND STAGE TURBINE FAILURE. ENGINE TO BE REPLACED. (M)May 10, 1996 · N604FF · Boeing 747121 · Turbine SectionSDR TWRA9611Fuel Filter · contaminatedON MARCH 11, 1996, AIRCRAFT, FLIGHT 42, ON DESCENT FROM FL 350 TO FL 330 EXPERIENCED A NR 1 ENGINE SHUT DOWN DUE TO NO THROTTLE RESPONSE. ENGINE WAS RESTARTED AT FL 330, AIRCRAFT LANDED WITH NO FURTHER INCIDENTS. UPON LANDING, MAINTENANCE FOUND FUEL FILTER CMar 11, 1996 · N604FF · Boeing 747121 · Engine Fuel DistributionSDR TWRA9602Coffee Maker · failedJFK/LAX - DURING FLIGHT, MID-GALLEY COFFEE MAKER TRIPPED CIRCUIT BREAKER. WHEN CIRCUIT BREAKER WAS RESET, A STRONG ODOR OF ELECTRICAL SMOKE WAS NOTICED FOLLOWED BY VISUAL SMOKE. THE GALLEY WAS ISOLATED BY SHUTTING OFF GALLEY POWER. THE GALLEY WAS PLACARDED,Jan 10, 1996 · N604FF · Boeing 747121 · Buffet/GalleysSDR TWRA9558Support Link · crackedNR 7 CANOE AFT SUPPORT LINK CRACKED. REMOVED AND REPLACED NR 7 FLAP TRACK LINK. OPS CHECK OK. (X)Oct 30, 1995 · N604FF · Boeing 747121 · Trailing Edge Flap Control SystemSDR TWRA9557Eng Vane Control · failedNR 1 ENGINE STALLED AT TOP OF DESCENT. EGT MAX 778 DEGREES, ENGINE SHUT-DOWN. RE-LIT NORMAL IN DESCENT AT FLIGHT LEVEL 280. ENGINE OPS NORMAL REMAINDER OF FLIGHT. REMOVED AND REPLACED EVC. OPS CHECK OK. (X)Oct 29, 1995 · N604FF · Boeing 747121 · Compressor Bleed ControlSDR TWRA9555Eel · inoperativeFORTY FOUR G/H LIGHT OVERHEAD EVAC LIGHTS INOP. REPLACED LIGHT ASSEMBLY. OPS CHECKS OK, MM33-50-00. SEAT MOUNTED EVAC LIGHT 14H INOP. REPAIRED WIRING. OPS CHECK OK 33-51-00. EVAC LENS MISSING SEAT 4H. REPLACED MISSING LENS. EVAC LENS PUSHED IN AT 5H. Oct 25, 1995 · N604FF · Boeing 747121 · Emergency LightingSDR TWRA9516Engine · malfunctionedABORTED TAKEOFF DUE TO NR 2 ENGINE EXPERIENCED A DROP IN EPR AND N1 ALONG WITH A INCREASE IN EGT. FOLLOWING TROUBLESHOOTING, MAINTENANCE ELECTED TO FERRY AIRCRAFT TO JFK FOR REPAIR. (W)Mar 12, 1995 · N604FF · Boeing 747121 · Engine (Turbine/Turboprop)
Back to N604FF, cancelled Jul 14, 2017