N786NC, cancelled Jun 17, 2014
Service difficulty reports · 131
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N786NC' AND deregistration_id = 'N786NC-2014-06-17' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N786NC' AND deregistration_id = 'N786NC-2014-06-17' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA13027620877Nut · undertorquedLEFT MLG RETRACT MECHANISM SUPPORT FITTING ATTACH NUT REQUIRES RETORQUE TO 200-250 FOOT POUNDS WITHIN 100 FLIGHT HOURS. RETORQUE OF LT MLG RETRACT MECHANISM FITTING IAW AMM 57-40.SDR DALA13027610877Nut · undertorquedRIGHT MLG RETRACT MECHANISM SUPPORT FITTING ATTACH NUT REQUIRES RETORQUE TO 200-250 FOOT LBS. TORQUE WITHIN APPROX 100 FLIGHT HOURS. RETORQUE OF RT MLG RETRACT MECHANISM FITTING IAW AMM 57- 40. CLOSED LOG AND REMOVED MONITOR INSPECTION IAW ALERT.SDR DALA13024570877Wire · brokenEMERGENCY ESCAPE PATH LIGHT INOPERATIVE AT ROW 2. FOUND BROKEN WIRE UNDER SEAT. REPAIRED WIRE IAW SWPM 20-10-03. CHECKED OK PER AMM 33-00.SDR DALA13020870877Fuse · inoperativeFIRST CLASS ESCAPE PATH LIGHTS INOPERATIVE. R & R FUSE IAW AMM 33-53. OP'S CHECKED GOOD.SDR DALA13020150877Fuse · inoperativeFOUND FIRST CLASS EMERGENCY LIGHT INOPERATIVE. R & R FUSE IAW AMM 33-52. OPS CK GOOD.SDR DALA13005680877Lanyard · detachedR1 DOOR SLIDE LANYARD DETACHED. SECURED R1 DOOR SLIDE LANYARD, OK FOR SERVICE.SDR DALA12012660877Wire · cutSEAT EMERGENCY PATH LIGHTS INOPERATIVE AT SEATS 6, 7 AND 8. FOUND CUT WIRE UNDER SEAT 8. SPLICED IN NEW HARNESS IAW BSWPM 20-00. CHECKS GOOD.SDR DALA12011480877Skin · corrodedDURING L CHECK, CARGO DOOR CUTOUT WAS FOUND DENTED/BENT. CORROSION WAS ALSO FOUND. REMOVED THE CORROSION AND PERFORMED REPAIRS IAW ER/A 507883-14, SECTION 1.SDR DALA12011310877Door Frame · crackedCRACK NOTED AT FWD SERVICE DOOR JAMB FWD UPPER CORNER. CRACK UNDER EXTERIOR SKIN APPROX 25" IN LENGTH ACCOMPLISHED REPAIR AT FWD SERVICE DOOR JAMB FWD UPPER CORNER AREA IAW DWG SRO9530172, CONFIG -7003 AND INSTALLED ID TAG ON DOUBLER REPAIR IAW PS 900-5-1 NR 4SDR DALA12000140877Structure · gougedDURING LINE CHECK, MAINTENANCE REPORTED A GOUGE ON THE FORWARD CARGO DOOR. MAINTENANCE DETERMINED THE GOUGE TO BE OUT OF LIMITS, REPLACED THE CARGO DOOR, AND RETURNED THE AIRCRAFT TO SERVICE AFTER INSPECTION.SDR DALA1206869877Power Supply · inoperativeEMERGENCY EGRESS AISLE LIGHTS, ROWS 19-22, AND RIGHT AFT OVERWING EXIT SIGN, INOP. REPLACED POWER SUPPLY UNIT AT AFT RIGHT OVERWING EXIT, CHECKS OK.SDR DALA1142889877Wire · brokenMAINTENANCE FOUND EMERGENCY ESCAPE PATH LIGHTS INOPERATIVE AND CRACKED AT ROWS 5 - 8. MAINTENANCE FOUND WIRE UNDER SEAT 8DEF BROKEN AND RE-ATTACHED IT. MAINTENANCE ALSO REPLACED ALL THE CRACKED LENSES. OPERATIONAL CHECK WAS GOOD. AIRCRAFT OK FOR SERVICE.SDR DALA1120519877Frame · corrodedFRAME & WEB HAS CORROSION AT STA 157 LT SIDE, FWD OF AIRSTAIR CUTOUT REMOVED CORR FROM FRAME AT STA IAW SRM 51-10-3 FOUND TO BE WITHIN LIMITS FRAME IAW SRM 53-01 WEB AT STA 157 LT SIDE FWD OF AIRSTAIR CUTOUT. FOUND TO BE OUT OF LIMITS IAW SRM 53-01 FIG 1 CUTOSDR DALA1120679877Floorboard · crackedFLOORBOARD PANEL 29 HAS BOTTOM GUIDE SUPPORTS WITH SEVERAL CRACKS. FABRICATED PANEL IN REF TO TRAVELERS 87145850001 ASSY, 87145860001 TOP SKIN 87145840001 HAT CHANNELS IAW ERA 489927-14 REV 0.SDR DALA1119869877Web · corrodedCORROSION ON PAN & STRUCTURE FOR POTABLE WATER STA 149 TO STA 160. LIMITS OF CORR AREA ON POTABLE WATER PAN WITHIN LIMITS PER DC9 SRM 51-10-3 WEB & STRUCTURE OUT OF LIMITS IAW DC9 SRM 53-01 FIG 1, CUT OUT DAMAGED AREAS ON WEB IAW DC9 SRM 51-70-4 FABBED AND INSDR DALA1119399877Stringer · crackedFWD CARGO COMP FUEL AUX TANK LWR STRINGERS ARE CRACKED 2EA.FWD FACE FABBED REPAIR CHANNEL STR PER SRM 53-05 FIG46. FABBED FILLERS PER SRM 53-05 PG 244, CUT OUT CRACKED AREAS PER SRM DC9 53-05 PG 244 INSPD AREAS HFEC. NO CRACK NOTED. INSTALLED REPAIR PARTS DESDR DALA1119389877Stringer · crackedFWD CARGO COMPARTMENT FUEL AUX TANK STRINGERS ARE CRACKED 2EA AS MARKED ON FWD FACE. FOUND DURING TANK RE-INSTALLATION. INSPECTION DETECTED 2EA CRACKS AT STRINGERS ABOVE 28L DETAIL I AND DETAIL II 26R, ASSET 09-182 CAL DOC 04/19/10, FABRICATED REPAIRS CHANSDR DALA1119369877Web · crackedFWD PASSENGER INTERNAL DOOR WEB HAS 1 INCH LONG CRACK. FABRICATED DOUBLER REPAIR, TREATED AND PRIMED, INSTALLED DOUBLER REPAIR IAW SRM 52-01 FIG 2 SHEET 3 PAGE 10 AND SRM 51-30-2 FIG 2 PAGE 3 AND RE-INSTALLED INNER SKIN IAW SRM 51-30-2 FIG 2 PAGE 3 INSTALLED SDR DALA1118389877Floor Support · wornFLOOR SUPPORT FOR MAIN CABIN WORN AT FLOOR PANEL CONTACT POINT RT SIDE AT 408 & 427. REMOVED FLOOR PANEL FROM MAIN CABIN RT STA 389 TO 465 IAW DC-9 SRM 53-05 FIG 20A, FOUND OUT OF LIMITS IAW DC-9 SRM 53-01 PAGE 8 AT STA 408 AND 427 RBL 4. FABBED AND INST 2EASDR DALA1118359877Floor Support · wornFLOOR SUPPORT FOR MAIN CABIN WORN AT FLOOR PANEL CONTACT POINT LT SIDE AT STA 484, 503, 522 FWD CARGO AREA. REMOVED FLOORBOARD IAW DC9-A-53-20-01-201-925 BLEND OUT DAMAGE AREA IAW DC9 SRM 53-01 IN LIMITS IAW DC9 SRM 53-01 FIG 1. CRACK ON REPAIR PLATE, REMOVESDR DALA1117149877Longeron · crackedLONGERON 17L CRACKED AT FRAME STA 389 ATTACH POINT REMOVED DAMAGE AT MAIN CABIN STA 380 TO 445 LONGERON 17 LT IAW SRM 53-02 FIG 18 PAGE 49-52. FABBED 1 EA LONGERON SECTION AND 1 EA REPAIR SPLICE IAW 53-02 FIG 18. TREATED AND PRIMED REPAIR PARTS IAW SRM 51-1SDR DALA1117139877Longeron · crackedLONGERON 2 LT CRACKED AT FRAME INTERSECTION STATION Y=160. REPAIR LONGERON SECTION FROM L-2 STA 148.5 TO STA 169 IAW SRM 53-02 PG 50 FIG 18.SDR DALA1116459877Floor Support · crackedFLOOR SUPPORT ANGLE CRACKED AND BENT AT STA 712 RBL-22 TO 33. REMOVED SUPPORT ANGLE AT STA 712 RBL 22 TO 33 PER SRM 53-30-5. FABRICATED SUPPORT ANGLE PER SRM 53-13-3 PG 26. TREATED AND PRIMED AND INSTALLED FLOOR SUPPORT ANGLE PER SRM 51-30-2 PG 1 & SRM 51-1SDR DALA1116449877Floor Panel · crackedFLOOR PANEL NR 64 UNDERSIDE OF PANEL, STRIP IS CRACKED AND DISBONDED. FABRICATED NEW FILLER STRIP AND REPAIR DOUBLER, .025 IAW DWG PL9957921 AND DC9-SRM-53-01, FIG 2, SHEET 3, PG12. TREATED AND PRIMED REPAIR DOUBLER, IAW DC9-SRM-51-10-313, PAR 2, PG 1-7. INSSDR DALA1116439877Floorbeam · crackedRT FLOOR STUB BEAM UPPER CHORD AND WEB CRACKED FWD AND AFT SIDES STA 712 UNDER CUSP WEB AREA. REMOVED, FABRICATED, RT FLOOR STUB BEAM WEB, IAW SRM 51-30-3, PG 19 AND DWG 9923410, TREATED AND PRIMED WEB IAW SRM 51-10 -4, PG1 AND INSTALLED WEB IAW SRM 51-30SDR DALA1116319877Longeron · crackedLONGERON 25L, CRACK AT FRAME STA 133 ATTACH POINT. CUT OUT DAMAGE SECTION OF LONGERON BETWEEN STA 110-133 25 LT LONGERON IAW SRM 53-02. FABRICATE LONGERON SECTION AND LONGERON SPLICE IAW SRM 53-02, PAGE 49-52, TREATED AND PRIMED REPAIR PARTS IAW SRM 51-10-3.SDR DALA1116289877Pan · crackedCRACK IN DOOR PAN STRUCTURE JUST OTBD OF SAFETY HOOK. STOP DRILLED CRACKS IN DOOR PAN IAW SRM 51-01, PG2, HFEC SURFACE INSP GS 24, 26B & 2001 NO CRACKS PASS STOP DRILL, FABRICATED REPAIR DOUBLER, IAW SRM 52-05 AND SRM 51-10-2. LOCATED & DRILLED REPAIR DOUBLERSDR DALA1116279877Skin · gougedLT FWD PASSENGER DOOR EXTERNAL SKIN IS GOUGED AND DENTED AT HOLD OPEN LATCH AFT SIDE. BLENDED OUT DAMAGE, IAW SRM-52-12-0, FIG1, ITEM 12, MATERIAL LOSS MEASURED FOUND TO BE OUT OF LIMITS IAW DC9-52-01, FIG 1 FABBED REPAIR DOUBLER, IAW DC9-SRM-52-05, FIG20. SDR DALA1116129877Skin · corrodedSTA 1063 AND LONGERON 30 CORROSION UNDER DOUBLER FOUND DURING MAUS INSP. REMOVED EXISTING REPAIR DOUBLER AT STA 1063 TO 1078, L29R TO L29L IAW SRM 51-30-5, PAGE 29. BLENDED OUT CORRODED AREA IAW SRM 53-04, PAGE 209, FIG 38: HFEC SURFACE INSP IAW NDTSPM 06-10-SDR DALA1116109877Floor Panel · corrodedFLOOR PANEL NR 21 HAS CORROSION AND BARE METAL. REMOVED SURFACE CORROSION FROM FLOOR PANEL, STA 200 TO 237, FOUND TO BE OUT OF LIMITS IAW SRM 53-01. FABRICATED FLOOR PANEL IAW EXISTING FLOOR PANEL LAYOUT IAW SRM 51-30-2, PG'S 15, 24, 26B TREATED & PRIMED ISDR DALA1116019877Longeron · crackedE&E COMPARTMENT STA Y207, LONGERON 24 L CRACKED. REMOVED DAMAGED SECTION OF LONGERON 24 LT STA Y207. FABBED LONGERON, LONGERON SPLICE IAW DC9 SRM 53-02 FIG 18 PG 50. REMOVED FASTENERS AT STA 207 AND 237 LT LONG 25 AND 26 AND OPENED SKIN IAW DC9 SRM 51-30-8 SDR DALA1115989877Floor Support · corrodedCENTER LINE FLOOR PANEL BEAM, FROM STA 237 TO 275, HAS CORROSION REMOVED FLOOR SUPPORT UPPER FLANGE STA 218 TO 303, BL0 FOUND OUT OF LIMITS IAW SRM 53-01, FIG 1, PAG 3. FABBED NEW FLOOR SUPPORT LOCATED AND DRILLED IAW SRM 53-13-1, FIG 11, 51-10-4 AND SRM 51-3SDR DALA1115979877Frame · crackedFOUND FRAME CRACK AT STA 332, STR 17R ATTACH POINT. REMOVED DAMAGE, FABRICATED REPAIR ANGLE, REPAIR PLATE, REPAIR FILLER, AND PLATE FILLER IAW SRM 53-05, FIG 4, PG 5, TREATED AND PRIMED REPAIR PARTS IAW SRM 51-10-3, PG 40, PAR 24 AND PG 15, INSTALLED REPAIR SDR DALA1115969877Frame · crackedFOUND FRAME CRACKED AT STA 275, STR 17R ATTACH POINT. REMOVED DAMAGE ON AREA AT FRAME STA 275, STR 17R IAW SRM-53-03-FIG 4, PG 5, FABRICATED REPAIR PARTS, REPAIR ANGLE, REPAIR FILLER, REPAIR PLATE IAW SRM 53-03, PG 5, FIG 4, TREATED AND PRIMED REPAIR PARTS,SDR DALA1115959877Frame · crackedFOUND FRAME CRACK AT STA 275 S17R ATTACH POINT, CORRECTED. REMOVED DAMAGE ON AREA AT FRAME STA 275, STR 17R IAW SRM-53-03, FIG 4, PG 5. FABRICATED REPAIR PARTS, REPAIR ANGLE, REPAIR FILLER, REPAIR PLATE, AND PLATE REPAIR, IAW SRM 53-03, PG 5, FIG 4, TREATED SDR DALA1115759877Floor Panel · brokenFLOOR PANEL NR 65 HAS A CORNER BROKEN. FABRICATED REPAIR DOUBLER FOR FLOOR PANEL 65 IAW SRM 53-01, PG 25, TREAT AND PRIME IAW SRM 51-10-3, PG 31. FASTENER INSTALLATION IAW SRM 51-30-2 COMPLETED.SDR DALA1115519877Structure · crackedOVERSIZED RIVNUT HOLE ON AFT SIDE OF FWD CARGO DOOR IS MISSING RIVNUT AND HOLE IS CRACKED. FABRICATED REPAIR DOUBLER IAW SRM 52-03, FIG 1. ALODINED REPAIR DOUBLER IAW SRM 51-10-3, PARA 21. PRIMED REPAIR DOUBLER IAW SRM 51-10-3B, PARA 2 F . INSTALLED REPAIR SDR DALA1115799877Skin · corrodedFUSELAGE SKIN CORROSION AT STA 1116, STR 28L, FOUND DURING MAUS SCAN INSP. AREA FOUND TO BE OUT OF LIMITS IAW SRM 53-04, PG 218, FIG 38. CUT OUT DAMAGE AREA IAW SRM 53-04 PG. FABRICATED REPAIR PARTS IAW SRM 53-04 TREATED AND PRIMED REPAIR PARTS IAW SRM 51-SDR DALA1116799877Longeron · crackedLONGERON 3L CRACKED AT FRAME INTERSECTION STATION BS 160. REPAIRED LONGERON SECTION 3L, STA BS 160 IAW DC9 SRM 53-02, FIG 18, PAGES 50-52.SDR DALA1115749877Door Frame · crackedAFT CARGO COMPT LOWER JAMB AT STA 1068 AND STR 28R STRINGER CLIP CRACKED. REMOVED 2 EA SPLICE REPAIR AND 1 EA TEE BRACKET AT STA 1068 AND 28R AFT5 CARGO IAW SRM 51-30-15, PG 29. REMOVED 1 EA CRACKED CLIP IAW SRM 51-30-15, PG 29, LOCATED AND DRILLED NEW STR CSDR DALA1115729877Floor Support · corrodedCORROSION ON BEAM FROM STA 160 TO 200 AT PANELS 18 AND 19, ENTIRE LENGTH. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW FIG 1, REMOVED CORRODED BEAM, FABRICATED, TREATED AND PRIMED IAW SRM 51-10-4 AND 53-13-1, FIG 11 INSTALLED BEAM FLOOR SUPPORT ON STA SDR DALA1115599877Floor Panel · corrodedFLOOR PANEL 73, HAS NUMEROUS SCREW HOLES CORRODED, BLENDED. FLOOR PANEL FOUND TO BE OUT OF LIMITS IAW SRM 53-01, FIG 1 AND SRM 53-25-0, FIG 4. RECEIVED MATL FOR FLOOR PANEL IAW SRM 53-23-0, FIG 5, FABRICATED FLOOR PANEL IAW SRM 53-23-0, FIG 5. TREATED AND SDR DALA1115549877Longeron · damagedRT STATIC PORT PLATE UPPER LONGERON HAS HOLES DRILLED IN UPPER CAP TRIMMED OUT DAMAGE AT LONGERON 24R, BETWEEN STA 522 TO 541 IAW AMM DC9-A-53-10-04-801-663-A-A, PERFORMED HFEC SURFACE INSP AT TRIMMED OUT AREA. NO CRACKS NOTED IAW NDT SPM 06-10-01.001. FABRISDR DALA1115249877Angle · crackedCRACK ON SUPPORT ANGLE AT PYLON 2 WEB BEHIND PNEUMATIC DUCTS /FIRE SHIELD ACCESS THRU DOOR 8206A. DRILLED .025 STOP HOLE AT END OF THE CRACK IAW DC-9 SRM 54-01 FIG 2 SHT 3 HFEC INSPECTION STOP DRILL AND NO PROG NOTED FABBED NEW REPAIR ANGLES 2 EA. HFEC SURFASDR DALA1115239877Doubler · crackedCRACK ON REPAIR DOUBLER AT PYLON 2 AFT APRON SECTION WEB IN FRONT OF AFT MOUNT FITTING INSIDE ACCESS 8206A. REMOVED REPAIR DOUBLER IAW DC-9 SRM 51-30-5 PARA 8. HFEC INSPECTION PREV STOP DRILL NO PROGRESSION NOTED. FABBED REPAIR IAW SRM 54-01 FIG 2 SHEET 2 DSDR DALA1114799877Floor Support · corrodedCORROSION ON FLOOR SUPPORT FOR PANELS 17 AND 18 ON TOP AND BOTTOM. BLENDED OUT DAMAGE AREA ON UPPER FLANGE ON FLOOR SUPPORT AT STA 160 TO 217 FOUND TO BE OUT OF LIMITS IAW SRM 53-01 PAGE 3 FIG 1 SHEET 3. REMOVED FLOOR SUPPORT STA 160 TO 217 BL 0 IAW SRM 51-3SDR DALA1114789877Floorbeam · corrodedFLOORBEAM JUST LEFT OF AC CENTER BEAM AT STA 200 HAS CORROSION. REMOVED CORROSION ON UPPER FLANGE ON FLOOR PANEL BEAM AT STA 200 FROM X1 TO X 20, DAMAGE FOUND OUT OF LIMITS IAW DC-9 SRM 53-01 PARA 3 SHEET 3 FIG 1. REMOVED AND REPLACED FLOOR PANEL BEAM SUPPORSDR DALA1114749877Longeron · crackedCRACKED AT FRAME STA 351 ATTACH POINT. REMOVED LONGERON NR 17R STA 323-437 IAW SRM 51-30-2 P 24 PAR A 7 FIG 19-20 LOCATED AND DRILLED NEW LONGERON PART NR S2777922-3-25000, BATCH 0002001515 PER SRM 51-10-4 PG 1 FIG 4. INSTALLED NEW LONGERON 17R FROM STA 323 SDR DALA1114279877Floor Support · crackedPAX CABIN FLOOR PANEL NR 68, LOWER STRUCTURE CHANNEL WITH CRACKS. REMOVED DAMAGE PAX CABIN FLOOR PANEL NR 68 LOWER STRUCTURE AND INSTALLED FLOOR SUPPORT LOWER STRUCTURE, BATCH NR 0001870883 IAW SRM 51-30-2 PARA 8 PG 26B.SDR DALA1114719877Floor Support · crackedFLOORBOARD PANEL NR 68 HAS BOTTOM GUIDE SUPPORTS WITH SEVERAL CRACKS. REMOVED 7 EA DAMAGED AREA, AND PREPARED DAMAGE AREA ON FLOORBOARD IAW MM 53-22-01-801-663A-A AND IAW SRM 51-90 -0, PARA 5E. APPLIED REPAIR PLIES AND HOT BONDED ON FLOOR BOARD DATE DUE
Back to N786NC, cancelled Jun 17, 2014