Service difficulty reports · 120
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR ABXA202210132110Fmc · malfunctionedAFTER LEFT ENG START, LEFT FMC WENT FULL BRIGHT WHICH CAUSED AND OVERLAY OF LINES. AIRCRAFT BACK TO BLOCK AND GROUNDED BY MAINTENANCE. MAINTENANCE DEFERRED THE LEFT CDU IAW MEL 34-61-1-1A. MAINTENANCE PROCEDURES COMPLIED WITH. PLACARD INSTALLED. AIRCRAFT RETUSDR ABXA2022082283Outflow Valve · faultedLOSS OF ALL CABIN PRESSURIZATION CONTROL @ FL 360 MX PAGE SHOWED AUTO 1/AUTO2 INOP. HI FLOW /EICAS SHOWED CABIN ALT MASTER WARNING CABIN AUTO INOP MASTER CAUTION. CREW ELECTED TO AIR TURNBACK TO DEN, MAINTENANCE GROUNDED AIRCRAFT. MAINYENANCE T/S PER 767FIM 21SDR ABXA2022080591Warning Message · false activationAFTER START R HD DEMAND PUMP EICAS MSG. AIRCRAFT BACK TO BLOCK AND GROUNDED BY MAINTENANCE. MAINTENANCE PERFORMED OPS CK OF RH ACMP & RH ENG DRIVEN HYD PUMPS WITH & WITH-OUT ENG RUNNING IAW B767 AMM 29-11-00. ALL OPS CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.
See all 120 reports