N80057, cancelled Oct 21, 2009
Service difficulty reports · 72
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N80057' AND deregistration_id = 'N80057-2009-10-21' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N80057' AND deregistration_id = 'N80057-2009-10-21' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA990435Wire · defectiveJFK - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS AT SEAT ROWS 14 THROUGHT 25 INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT FLAP JUMPER WIRE AT SEAT ROW 20. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA981833Slide · failedSJU - FLT 574 - AFTER TAKEOFF SJU EN ROUTE TO MIA, THE NR 1 ENGINE EXPERIENCED A FIRE. CREW DECLARED AN EMERGENCY AND SHUT ENGINE DOWN. AIRCRAFT AIR INTERRUPTED BACK TO SJU AND LANDED WITHOUT FURTHER INCIDENT. AFTER AIRCRAFT CAME TO A STOP AN EMERGENCY EGRESDR AALA981372Adapter · failedSJU - FLT 574 - DURING CRUISE NR 1 ENGINE WAS SHUT DOWN BY CREW DUE TO ENGINE FIRE. RETURNED AND LANDED SJU. REPLACED NR 1 ENGINE. SHOP FOUND THE AGB IDLER ADAPTER THREADED INSERTS WERE PULLED OUT CAUSING FUEL TO LEAK, FIRE AND ENGINE SHUTDOWN. GENERAL ELESDR AALA980807Connector · looseJFK - DURING OVERNIGHT MAINTENANCE, R3 DOOR OVERHEAD AND CEILING EMERGENCY LIGHTS WERE INOPERATIVE. RESEATED CONNECTOR AT R3 EMERGENCY EXIT DOOR LIGHT PACK. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AALA972217Beam · corrodedTUL - FOUND CORROSION ON LOWR DOOR BEAM FROM FRAME 2070 25A. CORROSION REMOVED AND DOUBLERS INSTALLED PER ESO 30595 DATED 11-19-97. (M)SDR AALA972216Fitting · corrodedTUL - CORROSION ON CORNER FITTING FORWARD SIDE OF FRAME 20 UNDER ROLLER TRAY NR 1. REMOVED AND REPLACED FITTING PER SRM 51-72-10-0. (M)SDR AALA972207Seat Track · corrodedTUL - FOUND CORROSION ALONG TO OF SEAT TRACK NR 8 FROM FRAME 30-33. REMOVED AND REPLACED SEAT TRACK FROM FRAME 30-33 PER SRM 51-72-10. (M)SDR AALA972160Support · corrodedTUL - FOUND CORROSION ALONG TOP OF FLOORBOARD SUPPORT AT FRAME 15B IN LINE WITH SEAT TRACK NR 9. REMOVED AND REPLACED FLOOR UPPORT PER SRM 51-7210-0 FRAME 17-13. (M)SDR AALA972166Support · corrodedTUL - CORROSION ALONG TRACK SUPPORT BEYOND LIMITS. REMOVED AND REPLACED TRACK SUPPORT FOR GALLEY PER SRM 51-72-10-0. (M)SDR AALA972165Support · corrodedTUL - FOUND CORROSION BEYOND LIMITS LAVATORY A AREA. REMOVED AND REPLACED TRACK PER SRM 51-72-10-0. (M)SDR AALA972164Support · corrodedTUL - CORROSION TOP SURFACE OF SUPPORT BEYOND LIMITS AT 29 RBL AT APPROX FRAME 15B. REMOVED AND REPLACED SECTION PER SRM 72-10-0. (M)SDR AALA972161Support · corrodedTUL - FORWARD CORROSION UNDER ROLLER TRAY RN 1 AT FRAME 56. SPLICED IN A SECTION OF FLOORBEAM PER SRM 53-10-15. (M)SDR AALA972156Channel · corrodedTUL - BALL MAT FORWARD SUPPORT C-CHANNEL IS CORRODED AT FRAME NR 20. INSTALLED EXTRUDED SECTION REPAIR TO FRAME 20 C-CHANNEL STRINGER 44L TO 45L AS PER A-300 SRM 51-71-50-2. REPAIR SECTION CPN 4054049. (M)SDR AALA972162Angle · corrodedTUL - FOUND CORROSION ALONG 'Z' ANGLE AT COCKPIT ENTRY FOR ABOUT 2 FT LEFT AND RT. REPLACED 'Z' ANGLE FROM BEAM NR 1 TO BEAM NR 5 WITH SPLICE PER SRM 51-71-40-2. ALODINED, PRIMED AND PAINTED PER SRM 51-21-00. (M)SDR AALA972124Connector · brokenJFK - DURINV OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS AT 3L/3R CROSS AISLE AND AT LEFT AISLE BETWEEN PAX SEAT ROWS 12 AND 16 INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT STRIP CONNECTORS AT 3L/3R CROSS AISLE AND REPLACED BROKEN EMERGENCY FLOOR LIGHT STRISDR AALA960145Eng Mount · corrodedTUL - FORWARD PYLON TRUSS ENGINE MOUNT, RT AFT HOLE HAS PITTING ON INNER WALL. HOLE REAMED BUSHING AND REPAIRED WASHER. INSTALLED PER ESO 30595, DATED 1-23-96. TST, 20,955 HOURS. CYCLES, 8,316. (X)SDR AALA960094Floor Support · corrodedTUL - CORROSION ON T-ANGLE SUPPORT FOR FLOOR/CARGO ROLLER TRACK/TRAY AT FRAME NR 56 AT NR 6 TRAY. INSTALLED NEW T-ANGLE, AND SPLICE SUPPORT DOUBLER PER SRM 53-10-15 AND SRM 51-71-50. TST, 20,955.4 HOURS. CYCLES, 8,316. (X)SDR AALA960132Floor Beam · corrodedTUL - CORROSION BEAM LT SIDE OUTBOARD END AT THE ROLLER TRAY, FRAME STA 63. INSTALLED NEW SECTION OF FLOORBEAM PER SRM 53-10-15 AT FRAME 63 AND TREATED, PRIMED, AND PAINTED PER SRM 51-74-10. TST, 20,955 HOURS. CYCLES, 8,316. (X)SDR AALA960091Support · corrodedTUL - CORROSION ON FLOOR SUPPORT 'A', RT SIDE AT R-4 DOOR FROM FRAME 73A TO FRAME 75A. INSTALLED FABRICATED PART PER AARD 51-10-00-3. ALODINED, PRIMED, AND PAINTED. TST, 20,955 HOURS. CYCLES, 8,316. (X)SDR AALA960052Skin · dentedTUL - DENT IN FUSELAGE SKIN AT FORWARD LOWER CORNER OF FORWARD CARGO CUT-OUT. REMOVED DAMAGE AND INSTALLED DOUBLER PER SRM 53-10-12. TST, 20,955 HOURS. CYCLES, 8,316. (X)SDR AALA952137Connector · brokenMAI - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS INOPERATIVE BETWEEN PAX SEAT ROWS 23 AND 27. REPLACED BROKEN EMERENCY FLOOR LIGHT CONNECTOR BY PAX SEAT ROW 23. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA952059Transmitter · defectiveMIA - FLT 0095 - DURING DESCENT INTO MIA, GREEN HYDRAULIC SYSTEM RESERVOIR LOW LEVEL INDICATION AND RESERVOIR GAUGE DROPPED TO RED DOT. ACCOMPLISHED ALTERNATE LANDING GEAR EXTENSION AND AIRCRAFT LANDED MIA WITHOUT INCIDENT. GAUGE READING RETURNED TO NORMAL A