N801US, cancelled Apr 13, 2017
Service difficulty reports · 60
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N801US' AND deregistration_id = 'N801US-2017-04-13' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N801US' AND deregistration_id = 'N801US-2017-04-13' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA960424Clips · crackedPIT - DURING Q-5/C5 CHECK INSPECTION, FOUND 3 CLIPS CRACKED RANGING FROM 1.75 INCH TO 2.25 INCH LONG CANTED FRAME STATION 1463 LONGERON 7, 9 AND 10. REPAIRED IAW SRM 53-14-4 FIG 3 SHEET NR 7 AND DACO DWG 9911839 AND 9911877. (M)SDR USAA960423Longeron · crackedPIT - DURING Q-5/C5 CHECK INSPECTION, FOUND 1 INCH CRACK AT LOWER FLANGE OF LONGERON 17L STATION 408. ACCOMPLISHED SPLICE REPAIR PER USAIR TYPICAL REPAIR 53-10-17. (M)SDR USAA960422Longeron · crackedPIT - DURING Q-5/C5 CHECK INSPECTION, TWO 1 INCH CRACK AT LOWER FLANGE OF LONGERON 17L, STATION 275 AND 294. ACCOMPLISHED SPLICE REPAIR PER TYPICAL REPAIR 53-10-17. (M)SDR USAA960421Skin · corrodedPIT - DURING Q-5/C5 CHECK INSPECTION, FOUND LEVEL 2 CORROSION AREA 4 INCHES BY 4 INCHES AT STATIC PORT HEATING PAD SKIN BETWEEN STATION 446 AND 465 BETWEEN LONGERON 26L AND 27L. CORROSION TASK REF C51-53300. REMOVED DAMAGED AREA AND SPLICED IN NEW SKIN SECTISDR USAA960420Longeron · corrodedPIT - DURING Q-5/C5 CHECK INSPECTION, FOUND 1 INCH BY 4 INCHES OF CORRODED AREA BETWEEN STATION 446 AND 465 LONGERON 26L. LEVEL 2 CORROSION REF TASK NR C-51-53300. REMOVED CORRODED SECTION AND SPLICED IN NEW LONGERON SECTION PER SRM 53-02 FIG 5. (M)SDR USAA960419Belt Frame · corrodedPIT - DURING Q-5/C5 CHECK INSPECTION, FOUND 2 INCH BY 3 INCH LEVEL 1 CORRODED AREA PREVIOUSLY REWORKED IN BELTFRAME STATION 1309 LONGERON 30. CORROSION TASK NR C57-53300. ACCOMPLISHED SPLICE REPAIR PER SRM 53-03 FIG 2. (M)SDR USAA951099T-Cap · crackedPIT - DURING C-4 CHECK INSPECTION, FOUND 3 INCH, 2 INCH AND A 1.1875 INCH CRACK IN STATION 1338 T-CAP AT LONGERON 14L, 12L AND BETWEEN 14L AND 15L. REMOVED AND REPLACED UPPER LEFT TEE CAP SEGMENT PER USAIR EO 5389X252 PART 2. (M)SDR USAA951043T-Cap · crackedPIT - DURING C-4 CHECK INSPECTION, FOUND A 3 INCH, 2 INCH AND A 1.1875 INCH CRACK AT STATION 1338 AT LONGERON 14L, 12L AND BETWEEN 14L AND 15L (EDDY CURRENT). REMOVED AND REPLACED UPPER LEFT T-CAP SEGMENT PER USAIR EO NR 5389X252 PART 2. (M)SDR USAA950842Eel Batteries · dischargedDCA - THE COCKPIT EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAA950619Pressurization · malfunctionedCLT - FLT 514 - ON TAKEOFF, THE AC FAILED TO PRESSURIZE. FLIGHT RETURNED TO CLT. MAINTENANCE PERFORMED BITE CHECKS ON THE CONTROLLERS. ALL CHECKED GOOD. (W)
Back to N801US, cancelled Apr 13, 2017