SDR QMLA2022010420002Transmission · noneUPON START UP PILOT GOT MASTER WARNIG CAUTION "TRANSMISSION CHIP LIGHT" AND SHUT DOWN AC. I CAME TO BASE AND INSPECTED BOTH TRANSMISSION CHIP DETECTORS AND FOUND MULTIPLE CHIPS ON BOTH. AFTYER DRAINING SYSTEM AND ISPECTING FLUID FROM FILTER HOUSING, GEARBOX ANSDR QMLA2018111118120Crosstube · failedAFTER RETURNING FROM FLIGHT ON LANDING AIRCRAFT TILTED TO THE LEFT, FORWARD LANDING GEAR CROSSTUBE FAILED.SDR QMLA2017031317028Doubler · crackedON TAIL ROTOR GEARBOX, 2 CRACKS WERE FOUND ON TAIL BOOM END FRAME DOUBLERS LEFT AND RIGHT, ONE CRACK EACH SIDE.SDR QMLA2016082116095Inverter · malfunctionedARRIVED AT SCENE WITH NO INCIDENT, SHUTDOWN, LOADED PATIENT AND DEPARTED, EN-ROUTE FOR DESTINATION, EXPERIENCED A FULL SAS FAILURE WITH BOTH SAS WARNING LIGHTS ILLUMINATED AND OSCILLATIONS OCCURRING. ONCE THE AIRCRAFT WAS SLOWED TO THE PROPER AIRSPEED IAW EMESDR QMLA2016061716068Transceiver · failedDURING AN IFT AT APPROXIMATELY 1 MINUTE OUT FROM LANDING A SPARK/FLASH WAS NOTICED FROM THE DASH AND A SMALL AMOUNT OF SMOKE WAS NOTICED COMING OUT OF THE TOP OF THE GLARE SHIELD THROUGH SOME VENTS IMMEDIATELY FOLLOWED BY AN ELECTRICAL BURNING ODOR. A QUICK LSDR QMLA2016040716037Converter · failedDURING THE FLIGHT TO THE HOSPITAL, AN ELEC BURNING SMELL WAS NOTICED BY THE MED CREW. THE MEDICAL EQUIPMENT WAS NOT WORKING DO TO SOME TYPE OF ELEC FAILURE. TURNED OFF THE POWER TO THE MEDICAL OUTLET & DIVERTED FROM MY COURSE & LANDED SAFELY. ACFT WAS INSPE