Service difficulty reports · 21
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR 20000425SH041Wire · shortedWHILE C/W SB 8-28-31, SPECIAL INSP OF FUEL TANK BONDING, MECH RECEIVED ELEC SHOCK WHEN HE TOUCHED FUEL PROBE WIRING HARNESS CONDUIT LOCATED BETWEEN STA YW189.0 AND YW207.0 IN RT FUEL TANK. CONDUIT FOUND TO THE ''LIVE'' WITH 20 VAC. INSP REVEALED EVIDENCE OF SDR QXEA9900420Wire · brokenPDX- AFT SMOKE DETECTOR LIGHT STAYS ON. MAINTENANCE REPAIRED BROKEN WIRES 2612-4A22 AT CONNECTION 2612-P2. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE. NO PARTS REPLACED.SDR QXEA9801754Battery · dischargedLEFT FORWARD FUSELAGE EMERGENCY LIGHT INOP. REPLACED BATTERY FOR EMERGENCY LIGHTING, OPERATION CHECK GOOD.