Service difficulty reports · 47
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR ABXA010818Downlock Switch · malfunctionedUPON LANDING, LANDING GEAR EXTENSION, THE NOSE LANDING GEAR GREEN LIGHT DID NOT ILLUMINATE. CHANGED BOTH BULBS, NO HELP. RECYCLED GEAR, NO HELP. RECYCLED GEAR A SECOND TIME AND GREEN LIGHT ILLUMINATED. INSPECTED NOSE LANDING GEAR, NO DEFECTS NOTED. REMOVESDR ABXA010203Light · inoperativeTHE EMERGENCY LIGHT AMBER LIGHT WOULD NOT ILLUMINATE. MAINTENANCE INSPECTED AND REPLACED THE EMERGENCY LIGHT AMBER LIGHT BULBS IAW DC-8 MM 33-00-00.SDR ABXA000494Bolt · brokenAFTER GEAR RETRACTION THE LANDING GEAR UNSAFE LIGHT REMAINED ILLUMINATED WITH GEAR HANDLE UP. GEAR WAS CYCLED WITH SAME INDICATIONS. AN UPLATCH CHECK WAS PERFORMED AND WITH THE GEAR HANDLE TO THE UPLATCH POSITION THE NOT LATCHED LIGHT ILLUMINATED. IN RIGHT
See all 47 reports