Service difficulty reports · 4
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR 17GR2018071818Motor · failedFREON AC MOTOR BLEW CURRENT LIMITER. MOTOR FAILED.SDR 17GRA59A0106Valve · failedCABIN WOULD NOT HEAT IN MANUAL OR AUTO MODE. DID NOT APPEAR THAT MANUAL CONTROL RESULTED IN ADDITONAL HEAT. BOTH FLOW CONTROL VALVES HAD FAILED.SDR A59A2017080800001Heat Exchanger · distortedCREW REPORTED A LEFT BLEED AIR LIGHT ON ANNUNCIATOR PANEL. OBSERVED A SPLIT IN ITT READING BETWEEN LEFT AND RIGHT ENGINE. (LEFT BLEED LIGHT AND HIGHER LEFT ITT) REDUCED POWER AND LIGHT EXTINGUISHED.SDR 2016F00202Motor · failedFREON AC STOPPED COOLING DURING GROUND OPERATION. FOUND DC MOTOR NO LONGER TURNING. MOTOR HAD 60 HOURS OF OPERATION WHEN INSTALLED.