N933HA, cancelled Apr 5, 2021
Service difficulty reports · 90
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N933HA' AND deregistration_id = 'N933HA-2021-04-05' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N933HA' AND deregistration_id = 'N933HA-2021-04-05' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2017041700123Battery · failedBOTH LT AND RT AFT EMERGENCY LIGHTS ARE INOPERATIVE. R & R THE BATTERY, FOUND THE LT AFT NEW EMERG BATTERY FAILED OPS. R & R THE BATTERY WITH ANOTHER NEW BATTERY.SDR HNAA2016122100347Switch · malfunctionedRED FLOOR EMERGENCY LIGHT IS INOPERATIVE. CYCLED SWITCH SEVERAL TIME, OPS CHECKED GOOD.SDR HNAAQ201611230035Battery Pack · inoperativeSEVERAL EMERGENCY LIGHTS ARE INOPERATIVE. REMOVED AND REPLACED THE BATTERY IAW WORK CARD 33-50-05R. OPS CHECKED GOOD.SDR HNAA2016101900324Bulb · inoperativeFLIGHT ATTENDANT EMERGENCY LIGHT SWITCH PANEL IS INOPERATIVE. REMOVED AND REPLACED THE BULB. OPS CHECKED GOOD.SDR HNAA2016101900323Bulb · inoperativeEMERGENCY LIGHT IS INOPERATIVE AT ROW 6. REMOVED AND REPLACED THE BULBS. OPS CHECKED GOOD.SDR HNAA2016101900322Bulb · inoperativeTHREE EMERGENCY CEILING LIGHTS ARE INOPERATIVE. REMOVED AND REPLACED THE BULBS. OPS CHECKED GOOD.SDR HNAA2016092600294Battery Pack · inoperativeRIGHT AFT OUTSIDE EMERGENCY EXIT EGRESS LIGHT IS INOPERATIVE. LOWERED PSU COVER AT ROW 7DF. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY. SECURED PSU COVER PANEL AT ROW 7DF. OPS CHECKED GOOD.SDR HNAA2016061700185Generator · malfunctionedAIRCRAFT TOOK LIGHTNING STRIKE-NR 1 AND NR 2, DC GENERATORS WERE TAKEN OFF LINE, SUCCESSFULLY RESET BOTH DC GENERATORS. GEAR WAS RETRACTED. COMPLETE ALL STEPS OF WORK CARD 05-50-31I, INSPECTION FOR REPORTED LIGHTNING STRIKE.SDR HNAA2016051100144Light · inoperativeEMERGENCY FLOOR LIGHT ROW 7DF INOPERATIVE. PULLED UP EMERGENCY FLOOR LIGHT COVER REPLACED INOPERATIVE EMERGENCY FLOOR LIGHT BULB AT 7DF. RESECURED EMERGENCY FLOOR LIGHT COVER.SDR HNAA2016032300089Bulb · inoperativeCABIN 2 AFT RED EMERGENCY LIGHTS WILL NOT ILLUMINATE AT RT FWD EXIT. R & R BULBS IN MODULE ASSY. OPS CHECKED GOOD.SDR HNAA2016020300030Battery Pack · inoperativeFORWARD EGRESS AND PASSENGER DOOR EMERGENCY LIGHTS ARE OUT. R & R EMERGENCY LIGHT BATTERY PS1 IAW MM 33-51-00. OPS CHECKED GOOD.SDR HNAA2016012900026Autofeather Sys · malfunctionedAUTOFEATHER WILL NOT ARM ON TAKEOFF ROLL. AUTO FEATHER SELECT SWITCH WENT BLANK. K5 CIRCUIT BREAKER TRIPPED. RESET CIRCUIT BREAKER K5 ENGINE TORQUE CONDITION. CLEANED CONNECTOR ON NR 2 ENGINE TSCU. GROUND RAN ACFT. AUTOFEATHER TEST FAILED. NO FIX. SLAVED SDR HNAA2016012700023Circuit Breaker · trippedIN FLIGHT, NR 2 TORQUE INDICATOR CIRCUIT BREAKER TRIPPED. REMOVED CONNECTOR FROM NR 2 TSCU. CLEANED, INSPECTED AND REINSTALLED CONNECTOR . RESET CIRCUIT BREAKER K-5. GROUND RAN ACFT. OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2016012700022Control Unit · malfunctionedAUTOFEATHER WOULD NOT ARM DURING TAKEOFF ROLL. R & R NR 2 TSCU. RAN AIRCRAFT. OPS CHECKED GOOD IAW MM 72-01-10.SDR HNAA2015102800320Battery Pack · inoperativeEMERGENCY AISLE LIGHT ABOVE ROW 4 INTERMITTENTLY. WILL NOT COME ON AS EXPECTED. R & R POWER SUPPLY FOR EMERGENCY LIGHTS AT ROWS 3AC AND 7DF IAW WC 33-50-05R AND 33-50-03Q. OPS CHECKED GOOD AT THIS TIME.SDR HNAA2015102800319Light · unknownROW 4 EMERGENCY LIGHTS WILL NOT EXTINGUISH AS EXPECTED, REQUIRES APU ON GROUND POWER TO TURN OFF. CHECKED EMERGENCY LIGHT SYS IAW WC 33-50-03Q. NO FAULT NOTED. OK FOR SERVICE.SDR HNAA2015082100261Bulb · inoperativeSMALL EXIT SIGN NEST TOO ROW 1DF HAS BULB OUT. R & R BULB. OPS CHECKED GOOD.SDR HNAA2015070600215Wire · chafedADVANCED POWER LEVERS FOR TAKEOFF, DURING FERRY FLIGHT AND LT MLG UNSAFE RED LIGHT AND GEAR HANDLE LIGHT ILLUMINATED. FOUND MULTIPLE CHAFED WIRES. HA300, SEQ 20, 18 AND 17. OPS CHECKED GOOD.SDR HNAA2015070600214Wire · chafedLEFT MAIN GEAR UNSAFE LIGHT AND GEAR HANDLE LIGHT AND WARNING HORN ILLUMINATED, SOUNDED. TAKEOFF REJECTED. FOUND MULTIPLE CHAFED WIRES. HA 300, SEQ 20,18 AND 17 FOR C/A. OPS CHECKED GOOD.SDR HNAA2015041000128Bulb · inoperativeROW 1 EMERGENCY FLOOR PATH LIGHTS INOPERATIVE. R & R BULB IN FLOOR PATH LIGHT. OPS CHECKED GOOD.SDR HNAA2015041000127Bulb · inoperativeEMERGENCY SIDEWALL LIGHTS ARE INOPERATIVE AT ROWS 1DF AND 4DF. R & R BULBS IN EMERGENCY SIDEWALL LIGHTS AT ROW 1DF AND 4DF. OPS CHECKED GOOD.SDR HNAA2014123100390Timer · failedWITH NR 1 PROPELLER TIMER SELECTED, BLADES 1 AND 3 CONTINUED TO HEAT. WOULD NOT CYCLE. DURING GROUND RUN, OPS CHECKED OF NR 2 PROPELLER TIMER. R & R NR 2 PROPELLER TIMER. OPS CHECKED GOOD IAW MM 30-61-00. OK FOR SERVICE.SDR HNAA2014121500365Bulb · inoperativeEMERGENCY LIGHT IS INOPERATIVE. R & R THE BULB, OPS CHECKED GOOD.SDR HNAA2014110700308Warning Light · illuminatedELEVATOR HORN HEAT CAUTION LIGHT ILLUMINATED IN FLIGHT. SELECTED ELEVATOR LT HORN HEAT TO ALTERNATE POSITION. GROUND RAN ACFT WITH CREW, SYSTEM OPS CHECKED GOOD IAW MM 30-16-00. OK FOR SERVICE.SDR HNAA2014100100277Propeller · malfunctionedNR 2 PROPELLER RPM WAS 1185 TO 1187 DURING TAKEOFF ROLL. ABORTED TAKEOFF. ALL OTHER ENGINE PARAMETERS NORMAL. RAN ENGINES BEFORE RETURNING TO GATE.SDR HNAA2014051900157Skin · damagedONE BURNED RIVET ON LT FUSELAGE SKIN 6.0" AFT OF VERTICAL FRONT BETWEEN STR 25A-26A. REMOVED RIVET AND BLENDED AREA. REMAINING .35" DEEP. REPAIRED IAW EO8-53-14-0224, EA 25-2014-150, REV A.SDR HNAA2014051900156Static Wick · burnedLEFT ELEVATOR OTBD STATIC WICK BURNED OFF AND MOUNTING PLATE DAMAGED. REMOVED OTBD END CAP, INSTALLED NEW END CAP, STATIC WICK AND MOUNTING PLATE IAW DWG 85520002 AND PREVIOUS REPAIR EA01-09126.SDR HNAA2014040400122Inverter · failedSTRONG FISH ODOR IN COCKPIT. INSPECTED PRIMARY, SECONDARY AND AUX INVERTER. NO DEFECTS NOTED. OPS CHCKED INVERTERS. NO ODOR, OPS CHECKED GOOD.SDR HNAA2014030300064Bulb · inoperativeEMERGENCY LIGHT INOPERATIVE. R & R BULB.SDR HNAA2014010300651Ecu · failedNR 2 ECU FAILED AFTER TAKEOFF. ACFT RETURNED TO, NR 2 ECU FAILED AND WEATHER CONDITIONS TO BAD TO CONTINUE.SDR HNAA2013122300629Bulb · inoperativeFLOOR EMERGENCY PATH LIGHT IS INOPERATIVE AT ROWS 5DF. CHANGED BULBS. OPS CHECKED GOOD.SDR HNAA2013120200596Unknown · odorDURING TAXI OUT WITH ENGINE BLEEDS SELECTED ON, A BURNING OIL ODOR IN FLIGHT DECK AND CABIN. WHEN BLEEDS WERE SELECTED OFF, ODOR STARTED TO DIMISHED. GROUND RAN BOTH ENGINES AND APU FOR ABOUT 20 MINUTES. WITH BLEEDS SELECTED ON AND OFF MULTIPLE TIMES, CHANGSDR HNAA2013111300570Controller · failedLEFT WINDSHIELD HOT CAUTION LIGHT ILLUMINATED IN FLIGHT. R & R CAPTAIN'S WINDSHIELD HEAT CONTROLLER. OPS CHECKED GOOD ON GROUND RUN IAW MM 30-41-00.SDR HNAA2013110600566Blade · vibrationNR 2 PROPELLER HAS EXCESSIVE VIBRATION IN FLIGHT. SHIMMED NR 3 AND NR 4 BLADES IAW MM 61-10-00. OPS CHECKED GOOD.SDR HNAA2013083000484Transmitter · damagedON TAKEOFF ROLL, RT SPOILER INDICATED DEPLOYED AND AGAIN IN TAXI MODE. INSPECTED RT INBD ROLL SPOILER, FOUND SYNCRO TRANSMITTER ARM OVER CENTER. REPOSITIONED TO CORRECT POSITION. GROUND RAN ACFT, OPS CHECKED SPOILERS. OPS CHECKED GOOD. ACFT OK FOR SERVICE.SDR HNAA2013080200442Radar · faultedPOSSIBLE LIGHTNING STRIKE. ACFT WAS DIVERTED, DUE TO POSSIBLE RADAR FAULT.SDR HNAA2013060500323Warning Light · false activationPASSENGER DOOR WARNING LIGHT ILLUMINATED ON TAKEOFF ROLL. ENTRY DOOR INDICATION WITH MOD APPENDIX 5 COMPLIED WITH.SDR HNAA2013052700310Bulb · failedOVERHEAD EMERGENCY LIGHT IS INOP AT ROW 7. R & R BULB. OPS CHECKED GOOD.SDR HNAA2013031800130Battery · inoperativeEMERGENCY LIGHTS GO DIM THEN OFF AFTER 30 SECONDS. R & R ALL EMERGENCY LIGHT BATTERIES IAW WC 33-50-05R AND WC 33-50-03Q FOR OPS CHECKSDR HNAA2012071100848Generator · failedRIGHT AC BUSS CAUTION LIGHT ILLUMINATED IN FLIGHT WITH ASSOCIATED CAUTION LIGHTS. COULD NOT DUPLICTE ON GROUND RUN. FOUND PROP HEAT SELECTED ON AT THE TIME. INSPECTED WIRING AND CURRENT LIMITERS IN RT AC CONTACTOR BOX. NO DEFECTS NOTED. R & R NR 2 AC GENERSDR HNAA2012052400802Brush Block · malfunctionedEMERGENCY LIGHTS FLICKER IN FLIGHT WITH PROP HEAT ON. INSPECTED NR 2 BRUSH BLOCK. NO DEFECT NOTED. REMOVED BOTH SPINNER AND INSPECTED HEATER LEADS. NO DEFECTS NOTED. REMOVED NR 1 BRUSH BLOCK AND R & R EMERGENCY LIGHT CONTROL BOX. GROUND RUN ACFT. OPS CHSDR HNAA2012051100770Bulb · failedEMERGENCY FLOOR PATH LIGHT IS INOPERATIVE AT ROW 6. R & R EMERGENCY FLOOR PATH LIGHT BULB AT ROW 6. REINSTALLED FLOOR STRIP. OPS CHECKED GOOD.SDR HNAA2012050300761Proximity Sensor · failedUPON GEAR RETRACTION, NOSE GEAR UNSAFE LIGHT ILLUMINATED. PERFORMED EMERGENCY EXTENSION. GOT GEAR DOWN AND LOCKED INDICATION. R & R NOSE GEAR DRAG STAY/UPLOCK PROX SENSOR AND ADJUSTED AS REQUIRED. CYCLED GEAR 20 TIMES. NO DEFECTS NOTED AT THIS TIME. OK FORSDR HNAA2012042600755Brush Block · intermittentEMERGENCY LIGHTS FLICKERED INTERMITTENTLY. R & R BOTH PROP BRUSH BLOCKS IAW 61-10-00.SDR HNAA2012042600752Starter Gen · failedNR 1 ENGINE START ASSOCIATED WITH BUSS FAULT. R & R NR 1 START GENERATOR IAW WC 24-30-02R. LEAKED AND OPS CHECKED GOOD.SDR HNAA2012040500717Control Box · intermittentALL EMERGENCY LIGHTS FLICKERED IN FLIGHT. R & R EMERGENCY LIGHT CONTROL BOX. OPS CHECKED GOOD IAW -8 MM 33-51-00.SDR HNAA2012032300703Bulb · failedROW 5 CEILING EMERGENCY LIGHT IS INOPERATIVE. R & R BULB. OPS CHECKED GOOD.SDR HNAA2012030500656Relay · malfunctionedAFTER GEAR RETRACTION, NLG RED UNSAFE AND AMBER INTRANSIT LIGHT REMAINED ILLUMINATED. AFTER 1 MINUTE, LIGHTS EXTINGUSHED. CYCLED GEAR DOWN GREEN LIGHTS ILLUMINATED. REPLACED RELAYS 3261-K5, K6, K7 AND K8. OPS CHECKED GOOD. PSEU TEST WITH NO FAULTS AND NO MESDR HNAA2012030500651Bulb · failedCEILING EMERGENCY LIGHT IS INOPERATIVE AT ROW 2. R & R EMERGENCY LIGHT BULB ON CEILING AT ROW 2. OPS CHECKED GOOD.SDR HNAA2012022700625Lamp · failedONE EMERGENCY FLOOR LIGHT OUT AT ROW 6DF AND 2 OUT AT ROW 8DF. RELAMPED FLOOR PATH LIGHTS AT ROW 6DF AND ROW 8DF AS REQUIRED. OPS CHECKED GOOD.
Back to N933HA, cancelled Apr 5, 2021