SDR Y2PA20120921044Fuel Cell · damagedEXCESSIVE FUEL LOSS IN FLIGHT. LT FUEL LOW PRESSURE LIGHT CAME ON. CLIMBED TO FL270. AS ACFT LEVELED OFF CREW REALIZED THE LT WING FUEL GAUGE INDICATES ZERO. SHORTLY AFTER LT FUEL LOW PRESSURE LIGHT ILLUMINATED. COM 2.28.9 PROCEDURE PERFORMED, CROSSFEESDR Y2PA20120422019Battery · illuminatedTAIL COMPARTMENT EMERGENCY EXIT SIGN ON RT SIDE NEAR TAILCONE INOPERATIVE. MX R & R THE BATTERY IN THE POWER SUPPLY. SYSTEM OPS CHECKED GOOD IAW MM 33-53-0.SDR Y2PA20120422018Power Supply · inoperativeCABIN CEILING AND AFT F/A STATION EMERGENCY LIGHTS INOPERATIVE. MX R & R THE EMERGENCY EXIT POWER SUPPLY. SYSTEM OPS CHECKED GOOD IAW MM 33-50-0.SDR Y2PA20120422017Power Supply · inoperativeAFT OVER WING EMERGENCY EXIT LIGHTS INOPERATIVE. MX R & R THE EMERGENCY EXIT POWER SUPPLY. OPS CHECKED GOOD IAW MM 33-53-0.SDR Y2PA2011092000023Battery Pack · dischargedFORWARD AND MID SECTION EMERGENCY LIGHTS FOUND INOPERATIVE DURING INSPECTION. MX R & R EMERGENCY LIGHTING POWER PACKS AT 7 EACH POSITIONS IAW AMM 33-53-00. OPS CHECKED GOOD.SDR Y2PA2010112400031Battery · dischargedROW 12, LT & RT EMERGENCY EXIT SIGN FWD OF OVERWING HATCH IS INOPERATIVE. DISCREPANCY FOUND DURING SERVICE CHECK. MX RECHARGED THE BATTERY SUPPLY. SYS OPERATIONALLY CHECKED GOOD IAW THE MM 33-53-0. ACFT RETURNED TO SERVICE.SDR Y2PA2009051400002Pump · inoperativeDURING CLIMBOUT, RT ENGINE DRIVEN HYD PUMP PRESSURE DROPPED (INDICATED) "0" PRESSURE. (LT SYS NORMAL) PERFORMED COM PROCEDURE - RESTORED RT SYS PRESSURE WITH "AUX" PUMP. AT 18,000 FT APPROACH CHECKLIST ALTITUDE, DECLARED AN EMERGENCY WITH APPROACH AS A PREC