N961N, cancelled Aug 4, 2008

Service difficulty reports · 38

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N961N' AND deregistration_id = 'N961N-2008-08-04'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR 0401989911Fuel Filter · leakingPILOT REPORTED A STRONG OIL/FUEL ODOR IN THE AIRCRAFT FOR ENTIRE LENGTH OF THE FLIGHT. MAINTENANCE FOUND THE APU LOW PRESSURE FUEL FILTER LEAKING 72 DROPS PER MINUTE. MAINTENANCE REPLACED THE FUEL FILTER AND PACKING. ALSO REPLACED COALESCER BAGS. COMPLIED Nov 10, 2004 · N961N · Doug DC931 · APU Engine Fuel and ControlSDR 0401829911Skin · crackedDURING L-CHECK FOUND CRACK IN SKIN IN UPPER FORWARD CORNER OF FORWARD SERVICE DOOR JAMB. REPAIRED PER EA 99-199627.Sep 1, 2004 · N961N · Doug DC931 · Fuselage Main, Plate/SkinSDR 0401819911Skin · crackedDURING L-CHECK, FOUND CRACK IN FUSELAGE NOSE SKIN AROUND FASTENERS AT BS 76.5 LBL 15 TO LBL 21. REPAIRED IAW EA 99-200584.Aug 24, 2004 · N961N · Doug DC931 · Fuselage Main, Plate/SkinSDR 0400369911Striker · out of adjustTHE AFT CARGO DOOR OPEN WARNING LIGHT ILLUMINATED DURING TAKEOFF ROLL. THE TAKEOFF WAS SAFELY ABORTED AT ABOUT 130 KTS AND THE AIRCRAFT EXITED THE RUNWAY WITHOUT INCIDENT. THE WARNING INDICATION EXTINGUISHED AS THE AIRCRAFT TURNED ONTO THE TAXIWAY. MAINTENAMar 5, 2004 · N961N · Doug DC931 · Door Warning SystemSDR 0204229911Skin · crackedDuring "H" check found crack in skin at upper aft corner of forward passenger door opening. Repaired per EA 99-193295.Dec 31, 2002 · N961N · Doug DC931 · Fuselage Main, Plate/SkinSDR 0201649911Apu · leakingDURING GROUND COOLING IN CLT, THE FLIGHT ATTENDANT NOTED A TRACE OF SMOKE IN THE CABIN. PACK WAS ADJUSTED TO WARMER TEMP AND PROBLEM ENDED. ON TAKEOFF, THE SMOKE RETURNED AND CAUSED THE FORWARD LAV SMOKE DETECTOR TO ALARM FOR ABOUT 3 MINUTES THEN CEASED. THMay 20, 2002 · N961N · Doug DC931 · APU Oil SystemSDR 9905329911Battery · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND VENTRAL STAIR EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES AT POWER SUPPLY B5-28, OPERATIONAL CHECK NORMAL.Dec 16, 1999 · N961N · Doug DC931 · Emergency LightingSDR 9904429911Fuel Control · malfunctionedDURING CRUISE FLIGHT, CABIN AND FLIGHT CREW PERSONNEL SMELLED FUMES IN THE AIRCRAFT. CATPAIN AND FIRST OFFICER DONNED OXYGEN MASKS. AN UNEVENTFUL LANDING WAS MADE AT DESTINATION AIRPORT. MAINTENANCE FOUND THAT FUEL WAS BEING INGESTED INTO THE APU. SOURCE OOct 28, 1999 · N961N · Doug DC931 · APU Engine Fuel and ControlSDR 9903909911Engine · failedAFT LEFT LAVATORY SMOKE DETECTOR SOUNDED WITH PASSENGER REPORTING STRANGE ODOR IN BACK OF CABIN. FLIGHT WAS RETURNED TO BHM AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED HEAT EXCHANGERS.Sep 16, 1999 · N961N · Doug DC931 · Engine (Turbine/Turboprop)SDR 9809639911Shutoff Valve · malfunctionedAFTER TAKEOFF, RUDDER WAS ABNORMALLY SENSITIVE TO SMALL AMOUNTS OF INPUT WITH DIFFICULTY TRACKING CENTERLINE. FLIGHT WAS RETURNED TO MEM AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED RUDDER POWER SHUTOFF VALVE, OPERATIONAL CHECK NORMAL.Jun 22, 1998 · N961N · Doug DC931 · Rudder Control SystemSDR 9802599911Battery Pack · dischargedDURING PERIODIC CHECK, FOUND TAILCONE CATWALK AND RELEASE HANDLE EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK. OPERATIONAL CHECK NORMAL.Feb 12, 1998 · N961N · Doug DC931 · Emergency LightingSDR 9722059911Battery Pack · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND LEFT NACELLE EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK IN AFT CARGO CEILING. OPERATIONAL CHECK NORMAL.Nov 24, 1997 · N961N · Doug DC931 · Emergency LightingSDR 9717189911Batteries · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND AFT FLIGHT ATTENDANT AND TAIL CONE SIDEWALL EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES, OPERATIONAL CHECK NORMAL.Sep 9, 1997 · N961N · Doug DC931 · Emergency LightingSDR 9715679911Battery Packs · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND BOTH ENGINE PYLON EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACKS, OPERATIONAL CHECK NORMAL.Aug 16, 1997 · N961N · Doug DC931 · Emergency LightingSDR 9711639911Servo · failedDURING CLIMBOUT, NR 1 COMPASS STARTED AN IMMEDIATE DRIFT WITH NO SLAVING WHEN ALIGNED TO PROPER HEADING. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED NR 1 COMPASS RACK, SERVO, AND SLAVE AMPLIFIERS, OPERATIONAL CHECK NORMAL.Jun 14, 1997 · N961N · Doug DC931 · Directional Gyro and Indicating SystemSDR 9710479911Fuel Control · failedDURING CLIMB, THE LEFT ENGINE EPR, N1, AND N2 INDICATIONS BEGAN FLUCTUATING. AIRCRAFT RETURNED TO MSP AND LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED THE LEFT ENGINE FUEL CONTROL UNIT. ENGINE OPERATIONAL CHECK OK. AIRCRAFT RETURNED TO SERVICE. POMay 26, 1997 · N961N · Doug DC931 · Fuel Control/Turbine EnginesSDR 9709429911Stall Warning · activatedSTALL WARNING STICK SHAKER ACTIVATED AT 190 KNOTS AFTER TAKEOFF. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. MAINTENANCE COULD NOT DUPLICATE DISCREPANCY ON GROUND WITH TEST EQUIPMENT. REPLACED THE LEFT STALL WARNING TRANSDUCER AND BOTH STALL WARNINGMay 13, 1997 · N961N · Doug DC931 · Stall Warning SystemSDR 9704319911Uplock Switch · malfunctionedLEFT MAIN GEAR UNSAFE LIGHT REMAINED ON AFTER GEAR RETRACTION ACCOMPANIED BY GEAR DOOR OPEN LIGHT. CREW RECYCLED GEAR WITH SAME RESULTS. FLIGHT RETURNED TO DTW AND LANDED WITHOUT INCIDENT. MAINTENANCE JACKED AIRCRAFT AND CYCLED GEAR NUMEROUS TIMES. DISCREPFeb 27, 1997 · N961N · Doug DC931 · Landing Gear Position and WarningSDR 9703689911Batteries · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND FORWARD CABIN OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES IN PACK. OPERATIONAL CHECK NORMAL.Feb 19, 1997 · N961N · Doug DC931 · Emergency LightingSDR 9703369911Battery · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND TAILCONE EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERIES IN BATTERY PACK, OPERATIONAL CHECK NORMAL.Feb 17, 1997 · N961N · Doug DC931 · Emergency LightingSDR 9627529911Connector · looseDURING LINE MAINTENANCE INSPECTION, FOUND FLOOR PROXIMITY EMERGENCY LIGHTS BETWEEN ROWS 1 THROUGH 4 INOPERATIVE. MAINTENANCE RESEATED SPLICE CONNECTOR IN OVERHEAD, OPERATIONAL CHECK NORMAL.Dec 31, 1996 · N961N · Doug DC931 · Emergency LightingSDR 9627099911Connector · damagedDURING LINE MAINTENANCE INSPECTION, FOUND FORWARD CABIN EMERGENCY LIGHTS INOPERATIVE. REPLACED POWER SUPPLY, NO HELP. REPAIRED BAD CONNECTOR BEHIND SIDEWALL, OPERATIONAL CHECK NORMAL.Dec 28, 1996 · N961N · Doug DC931 · Emergency LightingSDR 9626839911Evac Slide · low batteryDURING PERIODIC CHECK, MAIN CABIN DOOR EVACUATION SLIDE FAILED EMERGENCY BATTERY TEST. REPLACED SLIDE.Dec 22, 1996 · N961N · Doug DC931 · Escape SlideSDR 9623889911Fitting · corrodedDURING M-CHECK, FOUND CORROSION IN THE FS 218 CUSP FITTING AT LONGERON 18R. REPLACED FITTING PER 51-10-4, 53-01.Nov 8, 1996 · N961N · Doug DC931 · Fuselage Miscellaneous StructureSDR 9623869911Fitting · crackedDURING M-CHECK, FOUND A CRACK IN THE RBL 42 SEAT TRACK TO FS 680 FLOORBEAM ATTACH FITTING. REPLACED FITTING PER SRM 53-30-2.Nov 6, 1996 · N961N · Doug DC931 · Fuselage Miscellaneous StructureSDR 9621469911Outflow Valve · blocked by fodAUTO PRESSURIZATION SYSTEM FAILED AFTER TAKEOFF. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND INSULATION LODGED IN OUTFLOW VALVE WHICH WAS RESTRICTING MOVEMENT. REMOVED INSULATION AND REPLACED OUTFLOW VALVE ACTUATOR. OPERATIONAL CHOct 8, 1996 · N961N · Doug DC931 · Pressure Regulator/Outflow ValveSDR 9616269911Batteries · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND LEFT ENGINE NACELLE EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERIES. OPERATIONAL CHECK NORMAL.Jul 28, 1996 · N961N · Doug DC931 · Emergency LightingSDR 9614869911Batteries · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND FLOOR PROXIMITY EMERGENCY LIGHTS IN MID CABIN INOPERATIVE. REPLACED BATTERIES, OPERATIONAL CHECK NORMAL.Jul 5, 1996 · N961N · Doug DC931 · Emergency LightingSDR 9614859911Battery Pack · dischargedDURING LINE MAINTENANCE INSPECTION, FOUND LEFT NACELLE EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK AND BATTERIES, OPERATIONAL CHECK NORMAL.Jul 5, 1996 · N961N · Doug DC931 · Emergency LightingSDR 9608989911Uplock Assy · failedRIGHT MAIN LANDING GEAR UNSAFE LIGHT REMAINED ON AFTER GEAR WAS RETRACTED. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND FAULT IN RIGHT MAIN GEAR UPLOCK ASSEMBLY. REPLACED UPLOCK ASSEMBLY AND OPERATIONAL CHECK NORMAL.Apr 20, 1996 · N961N · Doug DC931 · Landing Gear Retraction/Extension SystemSDR 9606889911Altimeter · failedFIRST OFFICER'S ALTIMETER FAILED DURING CLIMBOUT AT APPROXIMATELY 11,500 FEET. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED FIRST OFFICER'S ALTIMETER AND OPERATIONAL CHECK NORMAL.Mar 23, 1996 · N961N · Doug DC931 · Altimeter, Barometric/EncoderSDR 9601289911Retract Mech · malfunctionedDURING TAKEOFF, A VIBRATION WAS DETECTED FROM THE NOSE WHEEL. AIRCRAFT CONTINUED TAKEOFF AND RETURNED TO MSP LANDING WITHOUT INCIDENT. FOUND RIGHT NOSE LANDING GEAR DOOR OPEN. SECURED DOOR AND OPERATIONAL CHECK GOOD.Jan 19, 1996 · N961N · Doug DC931 · Landing Gear Door Retract SectionSDR 9520099911Eel Power Supply · inoperativeDURING LINE CHECK, FOUND BOTH NACELLE EMERGENCY LIGHTS AND BOTH TAIL SLIDE LIGHTS INOPERATIVE. REPLACED POWER SUPPLY AND BATTERY. OPERATIONAL CHECK GOOD.Dec 11, 1995 · N961N · Doug DC931 · Emergency LightingSDR 9518809911Retract Mech · lack of lubeDURING CLIMB, A VIBRATION WAS FELT FROM THE NOSE LANDING GEAR, AFTER LANDING GEAR RETRACTION. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. FOUND RIGHT NOSE LANDING GEAR DOOR OPEN. INSPECTED ALL HINGE POINTS AND DOOR RELEASE MECHANISM, LUBRICATED ALL Nov 19, 1995 · N961N · Doug DC931 · Landing Gear Door Retract SectionSDR 9518339911Temp Control · malfunctionedYXE - DURING CLIMB, SMOKE ACCUMULATED IN THE CABIN, CREW FOLLOWED COCKPIT OPERATING MANUAL PROCEDURES. AIRCRAFT RETURNED TO YXE AND LANDED WITHOUT INCIDENT. REPLACED THE LEFT AIR CONDITIONING PACK CONTROLLER AND COALESCER BAG, OPERATIONAL CHECK GOOD.Nov 18, 1995 · N961N · Doug DC931 · Cabin Temperature ControllerSDR 9512239912Fuel Heat Valve · malfunctionedNR 1 ENGINE FUEL HEAT VALVE OPENED IN FLIGHT AND COULD NOT BE CLOSED WITH NORMAL PROCEDURES. THE ENGINE OIL TEMPERATURE EXCEEDED RECOMMENDED LIMITS, THE COM PROCEDURES WERE FOLLOWED AND A PRECAUTIONARY SHUTDOWN WAS ACCOMPLISHED. FLIGHT DIVERTED TO DTW AND LAAug 13, 1995 · N961N · Doug DC931 · Engine Fuel DistributionSDR 9510049911Cables · bindingSTRONG VIBRATION AND A LOUD NOISE FROM THE NOSE GEAR AREA, AFTER TAKEOFF. FLIGHT RETURNED TO SDF AND LANDED WITHOUT INCIDENT. FOUND BOTH NOSE GEAR DOOR CABLES AND BINDING AT PIVOT POINTS, CAUSING CABLE TO CATCH ON DOOR LINK AND BINDING DOORS. ADJUSTED LEFT Jun 17, 1995 · N961N · Doug DC931 · Landing Gear Door Retract SectionSDR 9506949911Door Frame · crackedDURING PERIODIC CHECK, FOUND CRACK IN THE RIGHT MAIN LANDING GEAR DOOR CUTOUT FRAME AT THE MICROSWITCH. REPAIRED FRAME PER EA 99-094843.Apr 26, 1995 · N961N · Doug DC931 · Fuselage Miscellaneous Structure
Back to N961N, cancelled Aug 4, 2008