Service difficulty reports · 27
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR RRXA010059Bottle · leakingAFTER SERVICING OXYGEN OF UPPER CREW BOTTLE - BOTTLE WAS INSTALLED & DURING TURN ON AT BOTTLE OXYGEN LINE & REGULATOR RUPTURED & CAUSED FLASH FIRE "A" PIT OXYGEN BOTTLE AREA. INSPECTED PURGED AND LEAK CHECKED CREW OXYGEN SYSTEM IAW OPS 4.901 AND TEST DRAWISDR RRXA10727Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO RT WING SKIN AT STA XFS 463 AND STR 63, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 EO 01-195.SDR RRXA10726Stringer · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO STR 63 RT WING AT STA XFS 463, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-2 FIG 3D.
See all 27 reports