N997GE, cancelled May 17, 2006
Service difficulty reports · 27
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N997GE' AND deregistration_id = 'N997GE-2006-05-17' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N997GE' AND deregistration_id = 'N997GE-2006-05-17' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA010059Bottle · leakingAFTER SERVICING OXYGEN OF UPPER CREW BOTTLE - BOTTLE WAS INSTALLED & DURING TURN ON AT BOTTLE OXYGEN LINE & REGULATOR RUPTURED & CAUSED FLASH FIRE "A" PIT OXYGEN BOTTLE AREA. INSPECTED PURGED AND LEAK CHECKED CREW OXYGEN SYSTEM IAW OPS 4.901 AND TEST DRAWISDR RRXA10727Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO RT WING SKIN AT STA XFS 463 AND STR 63, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 EO 01-195.SDR RRXA10726Stringer · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO STR 63 RT WING AT STA XFS 463, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-2 FIG 3D.SDR RRXA003333Seat Track · damagedDURING A MAINTENANCE VISIT FOUND A BROKEN SEAT TRACK LOCKING TAB NR 1 FROM LEFT TO RIGHT NR 5 BEAR CLAW UNDER BEAR CLAW, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IASDR RRXA003332Seat Track · damagedDURING A MAINTENANCE VISIT FOUND A BROKEN LUG AT NR 3 SEAT TRACK AT FWD PALLET STOP AT FS 80, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-3-0.SDR RRXA003288Pin · crackedDURING A MAINTENANCE VISIT FOUND THAT THE LT MLG RETRACT PIN NEEDS TO BE REPLACED, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA003287Pin · crackedDURING A MAINTENANCE VISIT FOUND THAT THE RT MLG RETRACT PIN NEEDED TO BE REPLACED, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.SDR RRXA001067Fitting · shearedAFTER T/O TOWER INFORMED US THAT LEFT MAIN GEAR DIDN''T RETRACT ON GEAR RETRACTION. AFTER PERFORMING LOW PASS TO CONFIRM GEAR WAS DOWN, RETURNED TO KDAY. DURING INSPECTION FOUND LT MLG ACT EYEBOLT ATTACH LUG SHEARED. PREPARED ACFT FOR FERRY FLIGHT TO KMQY SDR RRXA003001Doubler · crackedDURING A MAINTENANCE VISIT FOUND REPAIR DOUBLER INTERFERING WITH NEW SPLICE DOUBLER AT STA XFS 576, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, ALODINED AND PRIMED AREA IAAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SDR RRXA003014Bracket · brokenDURING A MAINTENANCE VISIT FOUND A BROKEN BRACKET ON THE LT WING L/E WING LOWER L/E AT STA XFS 622, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DCSDR RRXA003010Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE SPLICE ON THE LT WING CTR L/E MIDDLE OF L/E RIB, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8SDR RRXA003015Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING CTR L/E I/B BOTTOM SIDE NR 4 RIB I/B END, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-2-0 AND 51-1-20D.SDR RRXA003013Clip · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE ATTACH CLIP ON THE LT WING CTR L/E MIDDLE OF L/E AT SPLICE TOP SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1SDR RRXA003012Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING CTR L/E 14TH RIB O/B TOP SIDE OF L/E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, ALODINED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-20-0, 51-1-2SDR RRXA003011Doubler · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE SPLICE ON THE LT WING CTR L/E MIDDLE OF L/E DOUBLER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW SDR RRXA003009Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE O/B HOLE ON THE LT WING CTR L/E O/B END #2 RIB, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SDR RRXA003008Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING CTR L/E I/B BOTTOM SIDE NR 13 RIB, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-1, 51-2-0 AND 51-1-20D.SDR RRXA003007Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING CTR L/E TOP SIDE I/B NR 7 RIB, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 57-2-0, 51-1-20D AND 51-1-21, FSDR RRXA003006Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING CTR L/E TOP SIDE I/B #6 RIB, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 57-2-0,SDR RRXA003005Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING CTR L/E #4 RIB I/B BOTTOM OF L/E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51SDR RRXA003004Rib · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT WING CTR L/E I/B BOTTOM #5 RIB, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-20D SDR RRXA003016Angle · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE CHANNEL NUT PLATES ON THE LT L/E ABOVE NR 1 PYLON ANGLE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, ALODINED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-SDR RRXA003003Doubler · crackedDURING A MAINTENANCE VISIT FOUND DAMAGE TO THE LT WING L/E O/B OF #2 PYLON L/E DOUBLER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGED, ALODINED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW SDR RRXA003002Skin · crackedDURING A MAINTENANCE VISIT FOUND A CRACK IN LOWER SPAR CAP, WEB AND SKIN LOWER ON LEFT WING AT STA XFS 576, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPASDR RRXA001001Seam · crackedFUEL LEAK I/B NR 1 PYLON, WING LEADING EDGE CRACK 22.25 INCHES I/B NR 1 PYLON FWD TANK SEAM APPROX 4.5 INCH LONG.SDR RRXA000232Skin · corrodedEXFOILATION CORROSION DAMAGE TO A/C SKIN AT STA 320, LONGERON 36. CUT OUT CORROSION, FABRICATED FILLER AND DOUBLER USING .050 7075-T6. TREATED AND PRIMED FILLER, DOUBLER AND AREA. INSTALLED FILLER, DOUBLER AND SEALED IAW EO 00-091 NR 8900.SDR RRXA000183Indicator · failedON SHORT FINAL, OBSERVED SMOKE COMING FROM FLAP POSITION INDICATOR PANELS ABOUT THE FULL DOWN INDICY. TURNED OFF THE PEDESTAL LIGHTS AND THE SMOKE SUBSIDED. REMOVED AND REPLACED FLAP POSITION INDICATOR LIGHT PANEL FLAP POSITION. INDICATOR LIGHTING CHECKS N
Back to N997GE, cancelled May 17, 2006