SDR 2026FA0000429Turbine · defectiveTHE ENGINE ABY ESN 577716 WAS SLOTTED IN SAESM THE 17 APRIL 2026. DURING THE MM03 LEVEL INSPECTION OF THE LPT CASE, A DEFECT WAS IDENTIFIED ON 28TH MAY 2026. FOLLOWING THIS FINDING, A CSC CASE WAS RAISED TO CFM (TCH) REQUESTING AN APPROPRIATE REPAIR DISPOSITIOSDR WX0A2024080532144Engine · overtemp(AIRCRAFT NOT GROUNDED) ON CLIMB OUT ENG 2 HIGH OIL TEMP ADV. RAN QRH ECAM ADV LED TO ECAM ENG 2 OIL TEMP HIGH ENG 2 SHUTDOWN / REMOVED AND REPLACED #2 ENG IDG IAW AMM 24-21-51-000-040-B/24-21-51-400-040-E. LEAKS AND OPS CHECK GOOD AT THIS TIME."SDR WX0A2021071473765Engine · power loss(EMERGENCY DECLARED) #2 ENGINE ROLLED BACK DURING DECENT. ENGINE #2 WINDMILLED FOR ABOUT :17 MIN / AIRCRAFT IS CURRENTLY AOS AT TOL. TROUBLESHOOTING IN PROGRESS."SDR QEMY29012021Frame · damagedON INCOMING INSPECTION AT GE AVIATION WALES EASYJET ESN 699785, THE LPT FRAME WAS FOUND DAMAGED. THE LPT FRAME HAS BEEN REMOVED FROM SERVICE. DAMAGE CONSISTENT WITH ENGINE REMOVAL DAMAGE. OPERATOR INFORMED AND TO COMPLETE INVESTIGATION.SDR WX0A2019062173399Gasket · failedEMERGENCY DECLARED, NR 1 ENGINE FAILED. R & R FUEL NOZZLE FILTER GASKET.SDR A8ZR20170414001Bearing · migratedDURING PRE-FLIGHT CHECK, THE RUDDER TRAVEL DID NOT TOUCH FULL CONTROL BOX ON LOWER ECAM PAGE AND THE LAST 1/10 OF PEDAL TRAVEL WAS HARD. TROUBLESHOOTING AND INSPECTION FOUND THE LOWER RUDDER BELLCRANK BEARING MIGRATED FROM THE LEFT HAND LUG.SDR AALA201701229008Engine · stalledAIRCRAFT WAS GROUNDED. NEAR TOP OF DESCENT, MOMENTARY ONE TIME NR 1 ENGINE STALL, CORRECTED BEFORE ENGINE INDICATIONS CHANGED, ECAM CAME ON VERY BRIEFLY. MAINTENANCE REPLACED ENGINE PER TASK CARD 26L40071001.SDR WX0A2016042973145Engine · failedNUMBER 2 ENG FAILED DURING GO AROUND. DISCHARGED NR 1 FIRE BOTTLE. R&R NR 2 ENGINE PER T/C 71-400-001. ALL OPS AND LEAK CHECKS GOOD.SDR F3LA2014081201050Valve · closedIN CRUISE AT 31000 FT UNABLE TO MAINTAIN CABIN PRESS. CABIN ALTITUDE ROSE TO 10,200. R & R NR 2 ENG PRV IAW AMM 36-11-52-PB 401. OPERATIONS & LEAK CHECKED VLV & NO LEAKS NOTED. PREFORMED OPERATIONAL TEST OF THE BLEED AIR SYS IAW AMM 36-11-00-710-003-A. OSDR CA111103009Brake · failed(CAN) ON APPROACH, FLIGHT CREW REPORTED A FLIGHT CONTROL PROBLEM WHICH REQUIRED A GO-AROUND. AS A PRECAUTION, THE CREW DECLARED AN EMERGENCY WITH ATC (PAN-PAN) AND LANDED SAFELY. ON FLAP EXTENSION TO FLAPS 1 DURING APPROACH S-LOCKED. UNABLE TO CLEAR BY RECSDR F3LA200800505Sign · brokenDURING C-CHECK, INSP NOTED R1 DOOR FWD LOWER EXIT LIGHT IS BROKEN. MAINT REMOVED AND REPLACED R1 DOOR FWD LOWER EXIT LIGHT IAW AMM 33-51-13-400-001. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800501Sill · damagedDURING C-CHECK, INSP NOTED THE R2 DOOR SILL PLATE REQUIRED REPLACEMENT DUE TO MISDRILLED HOLE. MAINT REMOVED AND REPLACED R2 DOOR SILL PLATE IAW A319 SRM 51-42-11 AND 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800500Shear Plate · corrodedDURING C-CHECK, INSP NOTED THE RT LATERAL SHEAR PLATE AT Y-1162, FROM FRAME 69 TO FRAME 70, HAD CORROSION AND FOUR SHEARED FASTENERS AT THE FWD EDGE. MAINT REMOVED AND REPLACED THE LATERAL SHEAR PLATE AT Y-1162 AT FRAME 69 TO FRAME 70 IAW SRM 51-42-11. UPON SDR F3LA200800499Floor Panel · brokenDURING C4 S1 C CHECK, INSPECTION NOTED THE AFT CARGO FLOORBOARD, 151CE, HAD TWO BROKEN CORNERS. MAINTENANCE REMOVED AND REPLACED FLOOR PANEL 151CE. INSTALLATION WAS COMPLETED ON EMPIRE AERO CENTER NON ROUTINE NR 9642. UPON COMPLETION OF THE REPAIR IT WAS INSDR F3LA200800490Skin · dentedDURING C-CHECK INSP NOTED THAT THE DAMAGE ON NR 1 ENGINE INLET COWL REQUIRES PERMANENT REPAIR OF DENT AT THE 2 O`CLOCK POSITION. MAINT REPAIRED DAMAGED AREA IAW CMM 54-10-00, REPAIR PROCEDURE NR 23. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCESDR F3LA200800489Fitting · corrodedDURING C-CHECK INSP NOTED THE R1 DOOR GIRT BAR FITTING IB MOUNT HOLES ON SILL PLATE HAD CORROSION. MAINT BLENDED CORROSION IAW SRM 51-74-00. MAINT REPAIRED AREAS THAT WERE DEEPER THAT .016" WITH A FILLER AND FILLED AREAS THAT WERE LESS THAN .016" WITH ADHESIVESDR F3LA200800486Profile · corrodedDURING C-CHECK INSP NOTED THE AFT CARGO COMPARTMENT RT SIDE PROFILE HAD CORROSION AT FRAME 59 ON RT SIDE IAW A319 SRM 51-72-11 AND 51-44-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800491Fitting · crackedDURING C-CHECK INSP NOTED THE NR 1 ENGINE PYLON PANEL NR 413CL MOUNTS STRUCTURE WAS CRACKED AT AFT UPPER SCREW HOLE. MAINT REPAIRED NR 1 ENGINE PYLON PANEL NR 413CL MOUNT STRUCTURE AT AFT UPPER HOLE IAW SRM 54-52-12 AND 51-42-11. UPON COMPLETION OF THE REPAIR SDR F3LA200800488Door Frame · corrodedDURING C-CHECK INSP NOTED CORROSION ON TOP LEG OF FRAME C55A AT FWD EDGE OF C2 DOOR. MAINT REPAIRED DAMAGE ON TOP LEG OF FRAME C55A IAW EA NR A9-53R-30442. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800483Profile · gougedDURING C-CHECK INSP NOTED THE AFT CARGO COMPARTMENT PROFILE AT FRAME C63 IS GOUGED AND HAS A RIVET PULLING THROUGH. MAINT REMOVED AND REPLACED PROFILE AT FRAME C63 IAW SRM 51-72-11, 51-21-11 AND 51-42-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUNSDR F3LA200800484Profile · corrodedDURING C-CHECK INSP NOTED THE AFT CARGO COMPARTMENT PROFILE AT FRAME C59 HAD CORROSION AT BOTH ENDS OF THE PROFILE. MAINT REMOVED AND REPLACED THE PROFILE IAW SRM 51-42-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800485Profile · corrodedDURING C-CHECK INSP NOTED THE AFT CARGO COMPARTMENT SMALL PROFILE RT SIDE JUST INSIDE DOOR FWD OF FRAME C56 HAS CORROSION. MAINT REMOVED SMALL PROFILE, FABRICATED NEW PROFILE, TREATED, PRIMED AND TOP COATED NEW PROFILE AND INSTALLED IAW SRM 51-21-11, 51-53-11,SDR F3LA200800482Battery Box · wornDURING C-CHECK INSP, NOTED AFT BATTERY TRAY OB FWD AND AFT MOUNTS HAVE WEAR. MAINT REMOVED AND REPLACED AFT BATTERY TRAY, OB FWD AND AFT MOUNTS IAW SRM 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800469Floorbeam · corrodedDURING C-CHECK INSP NOTED AFT CARGO COMPARTMENT CENTER FLOORBEAM HAS CORROSION BETWEEN FRAME C57 AND FRAME C58. MAINT REMOVED AND REPLACED CORRODED FLOORBEAM AT FRAME C57 AND FRAME C58 IAW SRM 51-41-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND SDR F3LA200800470Profile · corrodedDURING C-CHECK INSP NOTED CORROSION SEVERAL PLACES ON AFT MOST PROFILE AT FWD CARGO COMPARTMENT AFT OF FRAME C30. MAINT REMOVED AND REPLACED PROFILE IAW SRM 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800465Frame · corrodedDURING C-CHECK INSP NOTED AFT CARGO COMPARTMENT INSIDE OF C2 DOOR SHORT ANGLE PIECE AT FRAME C59 HAS CORROSION. MAINT REMOVED SHORT ANGLE PIECE APPLIED PROTECTION TREATMENT FABRICATED NEW SHORT ANGLE TREATED, PRIMED AND PAINTED AND INSTALLED IAW SRM 51-72-11, SDR F3LA200800449Deu · inoperativeDURING FLIGHT MANY CABIN LIGHTS WERE COMING ON AND OFF ON AC RT. THE F/A NOTICED A BURNING SMELL OVER ROWS 16,17 AND 18 ON AC RT. MAINT FOUND DEU-A 200RH12 INOPERATIVE AND HAD A SMELL TO IT. MAINT REMOVED AND REPLACED DEU-A 200RH12 IAW AMM 23-73-46 AND OPS CHESDR F3LA200800480Seat Track · corrodedDURING C-CHECK INSP NOTED THE RT LONGERON BEAM Y-765 AT FRAME 66 HAD CORROSION AROUND THE HOLE. MAINT REMOVED AND REPLACED CORRODED LONGERON BEAM AT Y-765 FRAME 64 TO FRAME 66 IAW SRM 51-42-11 AND 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOSDR F3LA200800478Profile · corrodedDURING C-CHECK INSP, NOTED CORROSION ON AFT CARGO COMPARTMENT LT PROFILE, FWD AREA OF AFT CARGO, AT FRAME C47 TO FRAME C51. MAINT REMOVED AND REPLACED PROFILE AT FRAME C47 TO FRAME C51 IAW SRM 51-72-11, 51-21-11 AND 51-42-11. UPON COMPLETION FO THE REPAIR IT WSDR F3LA200800477Fitting · corrodedDURING C-CHECK INSP NOTED CORROSION ON PLATE BELOW TIE-DOWN PLATE AT FRAME C29 FWD CARGO COMPARTMENT. MAINT REMOVED AND REPLACED FITTING, REINSTALLED PLATE AND TIE-DOWN AT FWD CARGO COMPARTMENT FRAME C29 IAW SRM 51-42-11 AND 51-72-11. UPON COMPLETION OF THE RESDR F3LA200800476Profile · corrodedDURING C-CHECK INSP NOTED CORROSION ON PROFILE PARALLEL WITH FRAME C28 FWD CARGO COMPARTMENT. MAINT REMOVED AND REPLACED CORRODED PROFILE ON FRAME C28 IN FWD CARGO COMPARTMENT IAW FO A319 SRM 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ASDR F3LA200800475Girt Bar · stickingDURING C-CHECK INSP NOTED R1 GIRT BAR FITTING FOR DOOR SLIDE STOP LEVER STICKS, DOES NOT SNAP BACK WHEN PRESSED DOWN AND RELEASED. MAINT REMOVED AND REPLACED WITH NEW GIRT BAR FITTING IAW AMM 52-11-31-000-003 AND 52-11-31-400-003. UPON COMPLETION OF THE REPAIRSDR F3LA200800474Cargo Track · corrodedDURING C-CHECK INSP NOTED CORROSION ON PLATE BELOW TIE-DOWN PLATE UNDER FRAME C25 FWD CARGO PIT. MAINT REMOVED PLATE AND BLENDED CORROSION, MORE THAN 50 PERCENT MATERIAL LOSS AND FOUND TO BE OUT OF LIMITS IAW SRM 53-21-14 OUT TO LIMITS OR ACTIONS NOT STATED. SDR F3LA200800473Longeron · corrodedDURING C-CHECK INSP NOTED RT LONGERON BEAM AT Y-1162 FROM FRAME 68 TO FRAME 69 HAD AREAS OF CORROSION. MAINT REMOVED AND REPLACED FLOORBEAM LONGERON Y-1162 FROM FRAME 68 TO FRAME 69 IAW SRM 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCSDR F3LA200800472Floor Support · corrodedDURING C-CHECK INSP NOTED RT LONGERON BEAM AT Y-1292 FROM FRAME 66 TO FRAME 68 HAD AREAS OF CORROSION. MAINT REMOVED AND REPLACED FLOOR SUPPORT LONGERON Y-1292 FROM FRAME 66 TO FRAME 69 IAW SRM 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUNDSDR F3LA200800471Profile · corrodedDURING C-CHECK INSP NOTED CORROSION SEVERAL PLACES ON PROFILE LT SIDE AFT OF FRAME C28 FWD CARGO COMPARTMENT. MAINT REMOVED OLD PROFILE AT FRAME C28 ON LT SIDE, LOCATED AND DRILLED HOLES ON NEW PROFILE AND INSTALLED NEW PROFILE IAW SRM 51-72-11 AND SRM 51-42-1SDR F3LA200800487Skin · chafedDURING C-CHECK INSP NOTED THE RT AILERON APPEARS TO BE CHAFING AT IB LOWER EDGE. MAINT CLEANED AREA OF DAMAGE AND REPAIRED IAW SRM 51-75-12. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800481Floor Panel · damagedDURING C-CHECK INSP, NOTED FLOOR PANEL 261PF HAD COMPOSITE DAMAGE. MAINT REMOVED AND REPLACED FLOOR PANEL 261PF WITH NEW PANEL, REFERENCED ON EAC NON ROUTINE ITEM 9651. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800464Floor Panel · damagedDURING C-CHECK INSP NOTED FWD PIT PANEL 131EG DAMAGED. MAINT REPAIRED DAMAGE IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800451Floor Panel · damagedDURING C-CHECK INSP, NOTED AFT PIT PANEL 161CF DAMAGED. MAINT REMOVED DAMAGE AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800452Floor Panel · damagedDURING C-CHECK INSP, NOTED AFT PIT PANEL 162EF DAMAGED. MAINT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800453Floor Panel · damagedDURING C-CHECK INSP AFT PIT PANEL 161BF DAMAGED. MIANT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800454Panel · damagedDURING C-CHECK INSP, NOTED AFT PIT PANEL 161NF DAMAGED. MAINT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800455Floor Panel · damagedDURING C-CHECK INSP NOTED AFT PIT PANEL 151PE DAMAGED. MAINT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800456Panel · damagedDURING C-CHECK INSP NOTED AFT PIT PANEL 151DE DAMAGED. MAINT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800457Floor Panel · damagedDURING C-CHECK INSP NOTED AFT PIT PANEL 151FE DAMAGED. MAINT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800458Floor Panel · damagedDURING C-CHECK INSP NOTED AFT PIT PANEL 152WG DAMAGED. MAINT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800459Floor Panel · damagedDURING C-CHECK INSP NOTED AFT PIT PANEL 152UG DAMAGED. MAINT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800460Floor Panel · damagedDURING C-CHECK INSP NOTED AFT PIT FLOOR PANEL 151CE DAMAGED. MAINT REPAIRED DAMAGE IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800461Panel · damagedDURING C-CHECK INSP NOTED AFT PIT TRANSITION PANEL 151GE DAMAGED. MAINT REPAIRED DAMAGE IAW SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)
Back to CFM International CFM56-5B5 series