SDR CALA2014010990115Light · inoperativeSEAT EMERGENCY EXIT LIGHT ON SEAT 29C IS INOPERATIVE. REPLACED SEAT MOUNTED EMERGENCY LIGHT AT SEAT 29C IAW AMM 33-51-18, OPERATIONS CHECKED GOOD.SDR CALA2014010790066Light · inoperativeDOOR 1L SLIDE LIGHTS INOPERATIVE IAW TSM 33-51-00 -810-808-A.SDR CALA2014010790058Apu · shutdownAPU AUTO SHUTDOWN TWICE FOR UNDETERMINED REASONS.SDR CALA2014010990114Liner · damagedNR 2 ENG ATTRITION LINER AT 5:30 POSITION IS MISSING A SECT 1 1-4 BY 5-8 & AT 6:00 1-4 BY 1-2.SDR CALA2014010290021Sensor · faultyLG SLOW TO RETRACT, TOOK 1 MINUTE TO RETRACT. PFR SHOWS LG NOT UPLOCKED WITH CORRELATED FAILURE MESSAGES. LGCIU 5GA1 RT SHOCK ABSORB SIGNAL BSCU 10GG, RT LG EXT PROX SNSR 20GA TGT POS & CHECK LGCIU2 DISC INPUT. MORE LIKELY WILL NEED TO JACK ENTIRE ACFT FOR SDR CALA2014010390046Radio Altimeter · failedENROUTE FAILURE OF THE AUTO THRUST & NR 1 RADIO ALTIMETER. THESE FAILURES LIMITS AIRCRAFT CAPABILITY TO CAT I. DUE TO WEATHER CONDITIONS PIT, FLIGHT DIVERTING TO ORD.SDR CALA2014010290029Compressor Blade · damagedNICK ON FAN BLADE ENG 1. ENG 1 SNV10771 IAW MT72-007 FOR BLADES NUMBERING IAW AMM 72-31-11-200-010-B PARA 4B FOR ALLOWABLE DAMAGE LIMITS. REPLACED NR 19 FAN BLADE IAW AMM 72-31-11400-010-D13. ACCOMPLISHED VIBRATION SURVEY IAW AMM 71-00-00-700 -022, CHECKED SDR CALA2014010290018Cowl Door · out of adjustNR 2 ENG COWL HINGE PANEL ON BOTTOM OF ENG IS BENT & NOT SEATING NORMALLY. ADJUSTED DOOR, CHECKED OKAY.SDR CALA2014010290019Starter · malfunctionedSTART FAULT DISPLAYED ON UPPER ECAM SCREEN ENG 2. ENG 2 START FAULT LO START AIR PRESS, CHECK BLD AIR SUPPLY NR 2, ITEM ROLLED FWD. NORMAL AIR PRESS BUT NO ROTATION. MX ATTEMPTED STICK START, REPORTED AIR BLEED LEAK UNDER COWL. REPLACED THE ENG NR 2 STARTSDR CALA2014010290022Nose Cowl · dentedDENT & SCRATCH AT THE 5 O-CLOCK POSITION ON THE RT HAND ENG INLET COWL 6 INCHES LONG & A DENT 1 INCH DEEP. INLET COWL MR71212 PCN 115-9100 MUST BE REPAIRED OR REPLACED WITHIN 2 CYCLES, WORK ACCOMPLISHED BY LCL MAINT.SDR CALA2014010290020Switch · unsecureENG 1 ANTI ICE SWITCH KEEPS FALLING OUT OF SOCKET. REPLACED NR 1 ENG ANTI ICE SWITCH & RAN ENG ALL NORMAL.SDR CALA2013123094054Battery · faultyBCL 2 FAULT DISPLAYED ON UPPER ECAM SCREEN. ELEC REPLACED NR 2 BATTERY IAW AMM 24-38-51 PG 401, ALL TESTS PASSED.SDR CALA2013123094055Screw · missingCORNER & CORNER 1 SCREWS MISSING AT AFT INBD EDGE OF BELLY PNL JUST AFT OF ROT BCN. PLACED ON DEFERRAL NEEDS NUT PLATE PANEL 192KB INBD SIDE IAW 53-35-00-200-002A. ONLY ONE SCREW REMAINS MISSING WHICH IS INBD CTR, ALL OTHERS REPLACED.SDR CALA2013123094056Seal · missingFLIGHT ATTENDANT REPORT SQUEAL OVERWING EXIT, NOT SURE WHICH SIDE. PER FLIGHT ATTENDANT NOISE COMING FROM CEILING BETWEEN OVERWING EXITS & NOT EXIT DOORS. INSPECTED UPPER BEACON FOUND RUBBER BUNG MISSING FROM LIGHT LENS. REPLACED IAW IPC 33 -48-11-01A ITEM 2SDR CALA2013123093999Plug · faultyENG 2 START MALFUNCTION AUTO ABORT IGNITION 2 FAULT. R & R IGNITER PLUGS, OPERATIONS CHECKED OK.SDR CALA2013123094042Fastener · missingDADO PANELS THAT COVER EMERGENCY LIGHT BATTERIES AT ROW 21ABC & 21DEF MISSING ONE EACH FASTENER. IAW ECRA EC2523-01132 SECURED PANEL WITH TAPE.SDR CALA2013123094043Linkage · lack of lubeRT AFT SLIDE INDICATION INOPERATIVE ON DOOR OXY SYS ECAM PAGE DOOR OXY PROG. LUBED LINKAGE A FROM ARM HANDLE, OPERATIONS CHECKED NORMAL NUMEROUS TIMES.SDR CALA2013123094044Engine · damagedCHUNK OF MATERIAL HAS COME OUT INSIDE RT ENG BEFORE THE BLADES IN THE 6 O'CLOCK POSITION. MT 73-017 REV E, MUST BE REPAIRED WITHIN 20 CYCLES, PARTS NONE NEEDED.SDR CALA2013123094045Switch · faultyWITH NR 1 ENG SHUTDOWN, IGNITER IS POPPING & ECAM MESSAGE, NR 1 EIU FAULT DISPLAYED. REPLACED NR 1 ENG MASTER LEVER SWITCH. ENG RUNS NORMAL, SHUTDOWN NORMAL, NO FURTHER FAULTS NOTED.SDR CALA2013122793983Wire · shortedPIN F REMOVED FROM 450VT2 FOR DF988. IAW WD 26 12 08, MEG WIRE TO GND SORTED, WILL NEED TO OPEN JUNCTION BOX. SUGGEST WE HAVE DUCKS REMOVED AT 12 O'CLOCK POSITION TO SEE IF WE CAN GET ACCESS TO J BOX.SDR CALA2013122793995Battery · faultedIAW NR 2 SVC ITEM R EMERGENCY LIGHT TEST FAULTS BATTERY EMERGENCY LIGHT 33-51-38. RESET LT EMERGENCY BATTERY AMM 24-50-00.SDR CALA2013123094028Slide · defectiveDOOR SLIDE PRESS GAUGE DOOR 1R NOT VISIBLE. R & R DOOR R1 ESCAPE SLIDE IAW AMM TASKS 25-62-44-00-002-A & 25-62-44-400-006-A.SDR CALA2013123094029Panel · unsecurePCU UNIT FELL OUT OVER ROW 11DEF. NOT PSU PANEL, AIR PANEL WAS LOOSE & HANGING DOWN AT SEAT ROW 11DEF. SECURED PANEL IAW AMM, CHECKED OK TO CONTINUE.SDR CALA2013123094030Connector · faultyLGCIU 2 MESSAGE. BITE CHECK SHOWS RT LG EXTENSION PROX SENSOR. LM RECOMMENDS CHANGING CONNECTOR PCN 565-0643.SDR CALA2013122693961Speaker · inoperativeCAPTAIN`S SPEAKER INOPERATIVE. REPLACED SPEAKER & SPEAKER SWITCH, OPERATIONS CHECKED OK.SDR CALA2013122793982Audio Panel · faultyCAPT ACP IS NOT WORKING UNABLE TO SELECT. R & R ACP 1 & OPERATION CHECKED OKAY.SDR CALA2013122693942Acoustic Liner · damagedACOUSTIC LINER ON ENG 1 AT 8 O'CLOCK REPAIR CAME UNDONE LEAVING HOLE IN LINER. GRAPHITE MATERIAL MISSING & HONEYCOMB EXPOSED APPROXIMATELY 1.250 X.500 JUST AFT OF PREVIOUS REPAIR AT 8 O'CLOCK POSITION. MUST FIX IAW MT 71-006 ITEM 8. REPAIRED NR 1 ENG INLET SDR CALA2013122693959Servo Control · inoperativeREPLACED 2L SPOILER SERVO CONTROL COULD NOT GET IT TO ACTIVATE & FOUND THE MAINTENANCE DEVICE INOPERATIVE FROM STOCK. REPLACED 2L SPOILER SERVO CONTROL.SDR CALA2013122693960Connector · faultyBCL 1 FAULT DISPLAYED UPPER ECAM. REPLACED BATTERY LINE CONNECTOR 6PB1, CHECKED GOOD, MESSAGE DID NOT RETURN.SDR CALA2013122793981Connector · shortedLGCIU FAULT, MULTIPLE PROBLEMS AFTER. FOUND 23GA SENSOR CONNECTOR ON LT GEAR SHORTED. REPLACED CONNECTOR, CHECKED GOOD IAW TSM 32- 31-00-810-814-A. MESSAGE CLEARED & BITE CHECKED GOOD.SDR CALA2013122793984Shutoff Valve · faultyNR 1 ENG FIRE EXT SUB FUNCTIONS TEST FAILED STEPS D4 & D5 OF TASK CARD 4R2640019 SEQ NR 358. THE VLV G PUMP FIRE FAILED TO CLOSE WHEN NR 1 ENG FIRE SWITCH WAS RELEASED. DUE TO THE INTERMITTENT OPERATION OF THE NR 1 ENG HYD FIRE VLV 1046G K, WE NEED TO REPLACSDR CALA2013122693939Fuel Cap · brokenFUEL CAP BROKEN, REPLACED FUEL CAP.SDR CALA2013122393906Door · brokenFIRST OFFICER`S OXY MASK DOOR BROKEN. IAW GMM 05-30-06 REPLACED FIRST OFFICER`S OXY MASK DOOR.SDR CALA2013122693940Spoiler · inoperativeNR 2 SYMMETRICAL SPOILER SURFACES INOPERATIVE, RETRACTED & DEACTIVATED. SPOILER 2 FAULT, HAS BEEN RESET SEVERAL TIMES. REPLACED SERVO IAW MM, NO HELP.SDR CALA2013122693941Heat Shield · damagedDURING A CHECK FOUND ENG NR 2 RT SLEEVE HEAT SHIELD MISSING ONE PIECE TE 12 INCHES LONG. R & R AFT HEAT SHIELD & AFT CLOSURE AT NR 2 ENG RT C DUCT IAW V2500 CMM 78-30-00 REP 036. ALL NORMAL AFTERWARDS.SDR CALA2013122393907Stanchion · brokenRAMP REPORTS BROKEN STANCHION AT FWD SIDE OF AFT CARGO PIT DOOR. R & R STANCHION IAW AMM, OPERATIONS CHECKED GOOD.SDR CALA2013122393875Starter · faultyENG 2 START FAULT, NO ROTATION. TRAILING AIRCRAFT REPORTED OBSERVING SPARKS FROM THE COWLING. REPLACED STARTER IAW MM. PERFORMED DRY MOTOR LEAK TEST. STARTER OPERATES NORMALLY.SDR CALA2013122393895Wire · looseEMERGENCY EXIT LIGHT 12C INOPERATIVE. REPAIRED LOOSE WIRE TO LIGHT.SDR CALA2013122693909Audio Panel · damagedCOCKPIT ACP 2 INOPERATIVE. ACP 2 VHF 1 LIGHT COVER BROKEN. REPLACED FIRST OFFICER`S ACP, OPERATIONS CHECKED GOOD.SDR CALA2013122093830Starter · faultyAPU WON’T START AFTER 2ND ATTEMPT. TRIED CYCLING THE APU CONTROL BREAKERS, NO HELP. INLET DOOR STUCK IN THE PARTIALLY OPEN POSITION & APU IS INOPERATIVE. IAW MEL CB L41 & L42 OPENED & TAGGED. ACCOMPLISHED TSM 49-00-00-810-899 -A REPLACED APU MOTOR STARTER ISDR CALA2013122393876Interface Unit · faultyLGCIU 1 FAULT DISPLAYED ON UPPER ECAM SCREEN, LG. REPLACED LGCIU 1, CFDS BITE PASSED IAW AMM 32-31-71 P401 & 32-69-00.SDR CALA2013122393877Lens · missingEMERGENCY EXIT LIGHT ON CLOSET DOOR 1L MISSING COVER. BULB EXPOSED BUT IS INTACT.SDR CALA2013122693908Wire · damagedNR 2 ENG PYLON FWD FIRE EXTINGUISHING BOTTLE SQUIB 5WE2 CONDUIT TORN & MISSING SECTION WIRE INSULATION, WEARING ON METAL CLAMP. REPLACE WIRE 2621-0003- CF20 FROM CONNECTOR 5WE2A TO CONNECTOR 474VC IAW WDM 26-21-03 ESPM 20-44-16 & ESPM 20-32-22.SDR CALA2013122093831Light · inoperativeEMERGENCY EXIT LIGHT NEAR FIRST CLASS CLOSET INOPERATIVE. NEEDS 110-5146, ON AOG IPC 33-51-18-05, INSTALLED NEW RED EMERGENCY CLOSET DOOR LIGHT.SDR CALA2013122093856Torque Link · lack of lubeEXCESSIVE NOSE WHEEL VIBRATION AT 100 KTS & ABOVE UNTIL SLOWED IN WW ON TAKEOFF. LUBED NOSE WHEEL TORQUE LINKS, REPLACED ALL FOUR MLG TIRES IAW MT32-24 & OPBLM HIPPLE CORRECTED ATA.SDR CALA2013122093857Seal · peelingL1 WINDOW SEAL PEELING BACK DURING FLIGHT. CREATES NOISY ENVIRONMENT IN COCKPIT. REPAIRED L1 WINDOW SEAL IAW MT56-005.SDR CALA2013121993804Connector · defectiveLGCIU 2 FAULT DISPLAYED ON UPPER ECAM SCREEN. R & R CONNECTOR 22GA ON RT MAIN LG. IAW ASM 32-31-04. PERFORMED LAND TEST IAW AMM 22-97-00, ALL TEST PASSED. PLACARD REMOVED.SDR CALA2013121993805Acoustic Liner · damagedNR 2 ENG 6 O`CLOCK POSITION 2 INCH BY 1 DAMAGE IS IN ACOUSTICAL MATERIAL APPROXIMATELY 4 INCHES FROM AFT FLANGE. IAW MT71-006G FOR ALLOWABLE LIMITS. IAW ECRA 7111-01489 FOR ALLOWABLE FLY ON CRITERIA. INSPECTED IAW ECRA 7111-0 1489 & FOUND TO BE OK FOR CONTISDR CALA2013121993806Flap · dentedFOUND DENT IN LT INBD FLAP. DENT APPROXIMATELY .75 W X .062 DEEP, LOCATION 7 1-4 IN FROM TE 64 1-2 IN FROM INBD EDGE OK TO CF FOR 2C FOR EDDY CURRENT IAW ECRA 572101360.SDR CALA2013121993807Connector · faultyLGCIU 1 FAULT ON PUSH. REPLACED CONNECTOR TO PROX SWITCH 27GA. ACCOMPLISHED SATISFACTORY LGCIU 1 CFDS BITE TES, CHECKED OK & NO FAULTS.
Back to IAE V2522-A5