SDR UALA2009010200004Sensor · shortedECAM ANTI-ICE CAPT PITOT. FLIGHT DIVERTED. FOUND SENSOR 21GA SHORTED. REPLACED SENSOR AND ACCOMPLISHED GEAR SWING AND CFDS TEST AND SYS CHECKED NORMAL.SDR UALA2008122607007Electrical Box · malfunctionedELEC BURNING ODOR NOTED VICINITY OF SEATS 6 D, E, F. ODOR UNDER SEATS 2ABC. ISOLATED TO SEB AT 2ABC. REPLACED PER MM 23-33-46.SDR UALA2008122607003Warning System · activatedAFTER TAKEOFF, LANDING GEAR HANDLE WOULD NOT MOVE TO UP POSITION WITH LG SHOCK ABSORBER FAULT ECAM.SDR UALA2008122306979Strut · lowUNABLE TO MOVE LANDING GEAR HANDLE. NLG EXT PROX SENSOR 25GA TGT POS AND 24GA TGT POS WERE FLAGGED ON PFR. ACCOMPLISHED GENERAL INSP OF NOSE GEAR AND TORQUE LINK ASSY, CHECKS OK. FOUND STRUT INFLATION LOW. ACCOMPLISHED FULL SERVICE OF NLG, NO LEAKS. STRUTSDR UALA2008122406986Stringer · corrodedCORROSION ON STRINGER 42L BETWEEN FR 59 AND 60. MAJOR REPAIR. REMOVED DAMAGE AND INSTALLED REPAIR ANGLE.SDR UALA2008122406995Frame · corrodedCORROSION ON TOP OF FRAME 59, AFT PIT FLOOR JUST AFT OF PIT DOOR. MAJOR REPAIR. INSTALL STRAP REPAIR PER TIMCO REO-L01119. OBTAINED APPROVAL FROM AIRBUS VIA RAS-DAHAM-4900705-2008. ON NR K0145C BY 310884 AND INSPECTED BY LC67. THIS IS A PERMANENT REPAIR.SDR UALA2008121606908Battery · dischargedTHREE SVC EMER LIGHTS TEST FAILS. REPLACED EMERGENCY LIGHTS BATTERIES AT DOOR 1L AND L OVERWING POSITIONS. EMERGENCY LIGHTS TEST NOW PASSES.SDR UALA2008111806555Bottle · low pressureDOOR 1R SLIDE BOTTLE PRESSURE IS LOW. ACCOMPLISHED CHECK OF SLIDE PRESSURE. SLIDE PRESSURE GAUGE IN LOWER LIMITS OF GREEN BAND.SDR UALA2008111706533Power Supply · faultyEMERGENCY SEAT LIGHTS INOP SEATS 15-16, 19-20, 23-24. REPLACED FAULTY POWER SUPPLY UNIT AND BATTERY, OPS CHECK GOOD.SDR 2008UALA06479Mount Fitting · crackedR2 DOOR SLIDE LOWER FWD MOUNT FITTING IS CRACKED. REPLACED SLIDE.SDR 2008UALA06500Cover · missingSEAT 2B EMERGENCY EXIT LIGHT COVER MISSING. REPLACED EMERGENCY EXIT LIGHT COVER.SDR 2008UALA06332Anti-Ice System · malfunctionedPITOT HEAT & AUTO PILOT PROBLEMS. FLIGHT DIVERTED.
SDR 2008UALA06284Floorbeam · damagedFLOORBEAM 95 NEEDS TO BE REPLACED. MAJOR REPAIR ACCOMPLISHED. REPLACED FLOORBEAM 95.
SDR 2008UALA06269Power Supply · failedCABIN EMERGENCY LIGHT TEST FAILED. REPLACED POWER SUPPLY, OPS CHECKED NORMAL. CABIN EMERGENCY LIGHT TEST PASSED.SDR 2008UALA06283Shear Plate · crackedSHEAR PLATE AFT OF DOOR SILL 2 LEFT IS CRACKED. MAJOR REPAIR ACCOMPLISHED. INSTALLED PLATE. FWD HI-LOKS IN PLATE NEED TO BE INSTALLED. COMPLETED INSTALLATION.
SDR 2008UALA06271Floorbeam · damagedBEAM 150 NEEDS REPLACEMENT. MAJOR REPAIR ACCOMPLISHED. BEGAN REMOVAL OF BEAM 150. REMOVED FLOORBEAM 150 AND BEGAN INSTALLING BRACKETS ON BEAM. INSTALLED ALL BRACKETS AND JOINED FLOORBEAMS 150 AND 80 TOGETHER. REPLACED FLOORBEAM 150.
SDR 2008UALA06272Floorbeam · corrodedFLOORBEAM 80 HAS CORROSION. STARTED REMOVAL OF FLOORBEAM. CONNECTOR AND FORWARD END OF FLOORBEAM NEED TO BE REMOVED. REMOVED FLOORBEAM 80 AND BEGAN INSTALLING BRACKETS ON FLOORBEAM. INSTALLED ALL BRACKETS AND JOINED FLOORBEAMS 150 AND 80 TOGETHER. READY TSDR 2008UALA06261Sill · corrodedDOOR 2R SILL REMOVED FOR CORROSION. MAJOR REPAIR ACCOMPLISHED. BEGAN PICKING UP HOLES ON NEW SILL PLATE DOOR 2R. FINISHED INSTALLATION OF SILL PLATE FASTENER.
SDR 2008UALA06250Splice · corrodedBEAM 170 AT AFT SPLICE HAS CORROSION. REMOVED BEAM NR 170. NEW BEAM FASTENED TO ACFT FRAME. NEED TO INSTALL AFT SPLICES. COMPLETED INSTALLATION OF BEAM 170.
SDR 2008UALA06251Beam · corrodedBEAM 175 CORRODED, NEEDS REPLACEMENT. REMOVED BEAM NR 175. GALLEY MOUNT BRACKETS WERE TRANSFERRED TO NEW BEAM. BEAM IS FASTENED TO ACFT FRAME. NEED TO INSTALL FWD AND AFT SPLICES. COMPLETED INSTALLATION OF BEAM 175.
SDR 2008UALA06234Plate · corrodedDOOR 2 RIGHT SILL PLATE AT GIRT HOOK 4 EA ATTACH HOLES HAVE CORROSION. REMOVED SILL PLATE FOR REPLACEMENT.SDR 2008UALA06235Plate · corrodedDOOR 2R AFT SHEAR PLATE SUPPORT HAS CORROSION. MAJOR REPAIR ACCOMPLISHED: REMOVED SHEAR PLATE SUPPORT. REPLACED SHEAR PLATE SUPPORT.
SDR 2008UALA06236Plate · corrodedDOOR 2 RIGHT AFT SHEAR PLATE HAS CORROSION. MAJOR REPAIR ACCOMPLISHED REMOVED SHEAR PLATE. REPLACED SHEAR PLATE.SDR 2008UALA06202Wire · damagedCABIN EMERGENCY LIGHTS AT SEAT 10 ABC NOT ILLUMINATING. REPAIRED WIRE, TESTS OKAY.SDR 2008UALA06225Girt Bar · out of rigPRESSURE CHECK DOOR 2R FOR LEAKS AND MIGRATION OF SLIDE ARMED HANDLE, ACCOUNT OF SCUFF PLATES REPLACED AND GIRT BAR RIGGED. PRESSURE CHECKED DOOR AT 4 LBS, DOOR ARMED HANDLE GOOD, NO DOOR LEAKS.SDR UALA2008111306202Wire · damagedCABIN EMERGENCY LIGHTS AT SEAT 10 ABC NOT ILLUMINATING. REPAIRED WIRE, TESTS OKAY.SDR 2008UALA06207Unknown · odorF/A REPORTED PLASTIC BURNING ODOR NEAR DOOR 2L. SMELL GONE AFTER 5 MINUTES.
SDR UALA2008111306207Unknown · odorF/A REPORTED PLASTIC BURNING ODOR NEAR DOOR 2L. SMELL GONE AFTER 5 MINUTES. REMOVED COFFEEMAKERS, RAN CHILLERS, CHECKED AFT LAVS AND AFT LAV HEATERS, CHECKED AFT CARGO COMPARTMENT. NO PLASTIC OR BURNING SMELL NOTED. RE-INSTALLED COFFEEMAKERS.SDR 2008UALA06179Power Supply · dischargedEPSU AFT LT INTERIOR LIGHT FAULT ON 3SV EMERGENCY LIGHT CHECK. REPLACED AFT LEFT POWER SUPPLY AND BATTERY. LIGHTS CHECKED OK.SDR 2008UALA06036Warning System · activatedENGINE 1 BLEED FAULT. RTFL.SDR UALA2008111306036Bleed Valve · brokenENG 1 BLEED FAULT. RTFL. AIR CREW COMMENTS: ON CLIMBOUT THRU 3K FEET ECAM AIR ENG NR 1 BLEED FAULT; UNABLE TO RETURN NORMAL. FOUND CONNECTOR FOR VALVE 4001HA ON NR 1 ENGINE BROKEN. RE-ACTIVATED HPV. CREATED NEW ITEM FOR BLEED PRESS REG VALVE 4001HA RPL ASDR 2008UALA06031Panel · crackedLEFT VERTICAL STAB PANEL 322AL HAS CRACK 13.5 INCHES LONG, 4.25 INCHES BELOW TOP OF PANEL AND 9 INCHES AFT OF CENTER LINE. REMOVED AND REPAIRED PANEL.SDR 2008UALA06221Floorbeam · corrodedBEAM 140 CORRODED. REMOVED FLOORBEAM 140. TRANSFERRING FASTENER HOLES TO NEW BEAM. INSTALLING FASTENERS IN NEW BEAM. INSTALLED BEAM 140.SDR 2008UALA05991Attach Fitting · corrodedEVIDENCE OF CORROSION AROUND FWD GIRT BAR ATTACH FITTING DOOR 2R. INSTALLED CORNER FITTINGS AND GIRT BAR HOOK MOUNT PLATES ON NEW DOOR SILL.SDR 2008UALA06217Floorbeam · corrodedBEAM 95 CORRODED. REMOVED FLOORBEAM 95. REMOVED BRACKETS AND DRILLED NEW BEAM. ALL BRACKETS AND ATTACH FITTINGS INSTALLED. BEAM INSTALLED, ATTACHMENT COMPLETE AT FRAME 64, NEEDS BOLTS AT FRAME 66 AND 65. COMPLETED INSTALLATION OF BEAM.SDR UALA2008111306217Floorbeam · corrodedBEAM 95 CORRODED. REMOVED FLOORBEAM 95. REMOVED BRACKETS AND DRILLED NEW BEAM. ALL BRACKETS AND ATTACH FITTINGS INSTALLED. BEAM INSTALLED, ATTACHMENT COMPLETE AT FRAME 64, NEEDS BOLTS AT FRAME 66 AND 65. COMPLETED INSTALLATION OF BEAM.SDR 2008UALA05957Floorbeam · corrodedBEAM 175 CORRODED. BEAM OUT & BRACKETS INSTALLED ON NEW ONE. INSTALLED BEAM AND FASTENERS WITH SEALANT. INSPECTED BEAM 175 INSTALLATION AND FOUND SERVICEABLE.SDR 2008UALA05958Floorbeam · corrodedBEAM 145 CORRODED. REMOVED FLOORBEAM 145. TRANSFERRING FASTENER HOLES TO NEW BEAM. INSTALLING FASTENERS IN NEW BEAM. INSTALLED NEW BEAM.SDR 2008UALA05959Floorbeam · corrodedBEAM 140 CORRODED. REMOVED FLOORBEAM 140. TRANSFERRING FASTENER HOLES TO NEW BEAM. INSTALLING FASTENERS IN NEW BEAM. INSTALLED BEAM.SDR 2008UALA05960Floorbeam · corrodedBEAM 80 CORRODED. REMOVED FLOORBEAM 80. TRANSFERRING FASTENER HOLES TO NEW BEAM. INSTALLED BEAM.SDR 2008UALA05961Floorbeam · corrodedBEAM 95 CORRODED. REMOVED FLOORBEAM 95. REMOVED BRACKETS AND DRILLED NEW BEAM AND READY FOR BRACKET INSTALL. ALL BRACKETS AND ATTACH FITTINGS INSTALLED AND READY FOR INSTALLATION INTO AC. BEAM INSTALLED, ATTACHMENT COMPLETE AT FRAME 64, NEEDS BOLTS AT FRAMSDR 2008UALA05962Shear Plate · corrodedSHEAR PLATE AFT OF DOOR 2R BETWEEN FRAME 69 AND FRAME 70 CORRODED. REMOVED SHEAR PLATE AFT OF DOOR 2R. REPLACED WITH NEW SHEAR PLATE AFT OF DOOR 2R. INSPECTED THE INSTALLATION OF THE SHEAR PLATE AND FOUND SECURE.
SDR 2008UALA05963Floorbeam · corrodedBEAM 150 CORRODED. REMOVED FLOORBEAM 150. REMOVED BRACKETS AND DRILLED NEW BEAM AND READY FOR BRACKET INSTALL ON NEW BEAM. INSTALLED BEAM, NEEDS 2 BOLTS AT STA 70, 8 BOLTS AT STA 68. COMPLETED INSTALLATION OF BEAM. INSPECTED FINAL INSTALLATION OF BEAM 150SDR 2008UALA05977Structure · corrodedCORROSION AROUND NUT PLATE HOLES INBOARD OF AFT GIRT BAR FITTING DOOR 2L. REMOVED CORROSION PER MT 53-025. INSPECTED REPAIR PER MT53- 025. FOUND SERVICEABLE.
SDR 2008UALA05978Beam · corrodedCORROSION IN AREA OF PREVIOUS REPAIR BEAM 190. REMOVED CORROSION. INSPECTED REPAIR PER MT53- 025, FOUND SERVICEABLE.
SDR 2008UALA05970Battery Pack · faultyAFTER NR 3 SVC CABIN EMERGENCY LIGHT CHECK, CIDS PANEL SHOWS 33-51-38 EPSU BATTERY EMER L. BATTERY PACK FOUND FAULTY. REPLACED BATTERY PACK. OP CHECKS NORMAL.SDR 2008UALA05937Attach Fitting · crackedRIGHT FORWARD ENTRY DOOR SLIDE LOWER AFT ATTACH FITTING TO DOOR CRACKED. REPLACED SLIDE.SDR 2008UALA05925Smoke Detector · faultySMOKE LAVATORY DETECTOR FAULT. REPLACED LAV 'A' DETECTOR.SDR 2008UALA05924Smoke Detector · faultyLAVATORY DET FAULT DISPLAYED ON UPPER ECAM SCREEN - SMOKE. REPLACED SMOKE DETECTOR FWD AFT LAVATORY.SDR 2008UALA05922Floor Support · corrodedCORROSION ON FLOOR SUPPORT RT SIDE FR 70 STR 22-23. REMOVED CORROSION. FABRICATED & INSTALLED NEW FITTING.