IAE V2522-A5
Service difficulty reports · 3,465
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2522A5' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'V2522A5' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2007UALA05077Indicator · incorrectRTFL DUE TO NAVIGATION PROBLEMS HEADING SYSTEM NOT WORKING, POSITION NOT CORRECT.SDR 2007UALA05152Oxygen System · low pressureCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED CREW O2 TO 1850 PSI.SDR 2007UALA05048Epr System · faultedFLIGHT DIVERTED WITH NR 2 ENGINE EPR MODE FAULT AND NR 2 ENG N1 UNRATED.SDR 2007UALA05047Sensor · malfunctionedLANDING GEAR NOT DOWN AND LOCKED ECAM MSG. LANDING GEAR DISAGREE AFTER LANDING. LANDING GEAR DOOR NOT CLOSED ECAM. FOUND EXCESSIVE GAP ON NLG LEFT DOOR SENSOR 39GA. REPLACED NLG LT DOOR SENSOR 39GA, PERFORMED GEAR SWINGS, OPERATING NORMALLY.
SDR 2007UALA04994Lamp · inoperativeNR 1 ENGINE FIRE HANDLE HAS FOUR OUT OF EIGHT LIGHTS INOP. RELAMPED AND SWAPPED LGCIU AND ENG/APU FIRE IND PANEL.SDR 2007UALA05006Disc · rupturedL1 DOOR SLIDE HAS A LOW BOTTLE. FOUND RUPTURE DISC LEAKING. REPLACED RUPTURE DISC, SERVICED SYSTEM TO PROPER OPERATING LEVEL.SDR 2007UALA04963Battery · dischargedAFT JUMP SEAT EMERGENCY FLASH LIGHT RED STS LIGHT DOES NO BLINK. FOUND RECHARGEABLE BATTERY INOPERATIVE. REPLACED FLASH LIGHT BATTERY, OPS CHECKED GOOD.
SDR 2007UALA04964Accumulator · low pressureEMERGENCY CYLINDER ACCUMULATOR PRESSURE IS LOW AT DOORS 2L & 2R. FOUND LEAKAGE FROM PRESSURE CYLINDER. SERVICED ACCUMULATOR, ABLE TO HOLD PRESSURE WITH NO DECAY. NO REPEATS SINCE ORIGINAL.SDR 2007UALA05004Cable · out of adjustACFT PULLING LEFT, CONFIRMED HARD PULL. REPLACED STEERING TRANSDUCER, BOTH NOSE WHEEL TIRES, BSCU, NWS SENSOR 3GC. ADJUSTED NWS FEEDBACK CABLES TO FINAL FIX THE PROBLEM.SDR 2007UALA04897Retainer · damagedFORWARD ENTRY DOOR EXIT LIGHT PANEL, AT FLOOR LEVEL, INNER RETAINERS DAMAGED. REPLACED THREE RETAINERS ON DOOR EXIT LIGHT PANEL.SDR 2007UALA04898Light · inoperativeEMERGENCY LIGHT AISLE PATHWAY LIGHT AT ROW 11 OUT. REPLACED LIGHT ASSY.SDR 2007UALA04768Skin · damagedPUNCTURE HOLE IN SKIN JUST FWD AND BELOW DOOR 1L. REMOVED DAMAGED AREA AND PERFORMED HFEC AROUND CUTOUT, NO CRACKS NOTED. PERFORMED A TEMP REPAIR, PERMANENT REPAIR TO BE INSTALLED WITHIN 3000 FH.SDR 2007UALA04728Skin · damagedRUDDER T/E HAS AN AREA OF DELAMINATION 7" BY 80", TOP OF DAMAGE IS 90" BELOW TIP AND BOTTOM OF DAMAGE IS 79" FROM BOTTOM OF RUDDER. REPLACED RUDDER & OP CHK'D ON NR G7263I. INSTALLED RUDDER IS TS1274.SDR 2007UALA04766Cylinder · corrodedLEFT MAIN LANDING GEAR, OUTER CYLINDER, FOUND CORROSION ON INNER SURFACE. REPLACED THE LT GEAR AND SENT UNIT TO SHOP FOR COMPLETE OVERHAUL.SDR 2007UALA04720Seat Track · damagedLEFT INBOARD SEAT TRACK Y765 FROM FR41 TO FR 47-51 HAS WEAR AT LUGS. REPLACED SEAT TRACK.SDR 2007UALA04716Unknown · unknownLEFT OUTER FUEL TRANSFER VALVE AMBER HALF CLOSED. NO STATUS MSG. VALVE WAS FOUND TO BE OPERATING NORMALLY.
SDR 2007UALA04722Sensor · out of alignmentON GEAR RETRACTION, LANDING GEAR NOT UPLOCKED, DISPLAYED WITH ASSOCIATED ANTI-ICE STDY PITOT HEAT MESSAGE. CREW CYCLED GEAR AND ALL FAULTS CLEARED. FOUND SENSORS 24GA AND 25GA NOT ALIGNED. RE-ALIGNED SENSORS 24GA AND 25GA. PERFORMED GEAR SWING WITH SATISFSDR 2007UALA04732Slide · faultyR2 DOOR ARM HANDLE FAILS PUSH-PULL TEST. REMOVED SLIDE PACK AND PERFORMED OPS CHECK AND TENSION CHECK OF ARM HANDLE- ALL CHECKED GOOD. REINSTALLED SLIDE AND PUT BACK INTO SERVICE--NO REPEATS SINCE.SDR 2007UALA04717Oxygen Mask · leakingCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS: CURRENT PRI 830. O2 AT 1600 PSI AT START OF FLIGHT. FOUND MASK LEAKING. REPLACED THE F OBS MASK AND SERVICED THE CREW O2 SYSTEM.
SDR 2007UALA04685Sensor · malfunctionedGEAR HANDLE WOULD NOT GO UP AFTER TAKEOFF UNTIL ABOVE ABOUT 150 FEET. FOUND SENSOR 22GA OUT OF ADJUSTMENT/TOLERANCE. ADJUSTED SENSOR 22GA AND ADJUSTED UPPER TORQUE LINKS. FAC1 AND FAC2 WERE ALSO REPLACED AS PRECAUTIONARY. NO REPEATS,,SDR 2007UALA04690Light · brokenEXIT LIGHT AT FLOOR LEVEL OF DOOR 1R BROKEN OFF OF MOUNT. REPLACED EXIT LIGHT ASSY.
SDR 2007UALA04686Brake Assy · draggingHARD RIGHT RUDDER NEEDED TO MAINTAIN STRAIGHT TAKEOFF AND LANDING. REPLACED BOTH NOSE TIRES, PERFORMED A FNC OF STEERING SYSTEM- NO FAULTS FOUND, JACKED EACH MAIN TIRE AND SPUN TO CHECK FOR WHEEL BEARINGS DRAGGING/BRAKES DRAGGING--NONE FOUND. NO REPEATS SINSDR 2007UALA04657Oxygen Bottle · reads lowTHE O2 BOTTLE AT 24C LOW. REPLACED THE LONG O2 BOTTLE UNDER SEAT 24C WITH A NEW ONE.SDR 2007UALA04610Oxygen Mask · misinstalledFIRST OFFICER'S O2 MASK LEAKING. FOUND CREW O2 MASK (FO) WAS NOT PROPERLY STOWED. RESTOWED FO MASK- NO LEAKING- SERVICED CREW O2 SYSTEM.SDR 2007UALA04608Control Panel · no testENG 2 AGENT1 SQUIB LT DOES NOT ILLUMINATE DURING TEST. FOUND ENG/APU FIRE CONTROL PANEL FAULT. REPLACED ENG/APU FIRE CONTROL PANEL. ALL SYSTEMS TESTED AND OPS CHECKED OK.
SDR 2007UALA04578Computer · malfunctionedELAC 2 PITCH FAULT DISPLAYED ON UPPER ECAM SCREEN. PERFORMED RESET AND OPERATIONAL TEST OF ELAC2. OPS CHECK GOOD.SDR 2007UALA04538Oxygen System · reads low02 LOW REQUIRES SERVICING. SERVICED CREW O2 SYSTEMSDR 2007UALA04540Computer · faultyELAC 2 PITCH FAULT DISPLAYED ON UPPER ECAM SCREEN. ELAC2 FAULTY-NFF. REPLACED ELAC2 - ALL TESTS PASSED.SDR 2007UALA04569Oxygen System · reads lowCREW OXYGEN SYSTEM-LOW, RECORD PRESSURE PRIOR TO SERVICING. CREW COMMENTS: 02 AT 1200 PSI. SERVICED CREW O2 SYSTEM. NO REPEATS.SDR 2007UALA04535Seat Track · wornLT INBD AND OTBD AND RT INBD AND OTBD OVERWING SEAT TRACKS ARE WORN OUT OF LIMITS FROM WHERE FWD SEAT LUGS LOCK INTO TRACKS BETWEEN FRAMES 41 AND 47 MAJOR REPAIR ACCOMPLISHED. DURING HMV VISIT.
SDR 2007UALA04483Oxygen System · reads lowCREW OXYGEN SYSTEM LOW RECORD PRESSURE PRIOR TO SERVICING. SERVICED CREW O2 SYSTEM TO 1800 PSI- NO REPEATS SINCE ORIGINAL.
SDR 2007UALA04504Flap · damagedBIRD STRIKE RT WING OUTBOARD FLAP. ACCOMPLISHED REPAIR ON RIGHT WING OUTBOARD FLAP.SDR 2007UALA04447Unknown · unknownDURING TAXI AIRCRAFT TENDS UNSAFELY TO THE RIGHT. ALSO BRAKE TEMP WENT UP TO 185 DEG VS 35 DEG ON OPPOSITE SIDE TO KEEP NOSE CENTERED ONLINE. REPLACED SEVERAL PARTS AND COMPONENTS, LASTLY A NOSE WHEEL STEERING SERVO CONTROL UNIT WHICH BROUGHT THE A/C BACK ISDR 2007UALA04402Structure · dentedCREW REPORTS EVIDENCE OF BIRDSTRIKE ON LT WING INBOARD OF ENG WITH SIGNIFICANT DENT. NR 1 L/E SLAT LT WING DENT MEASURES .46875 DEEP, 3.5 WIDE AND 5.25 LONG, OUT OF LIMITS. REPLACED NR 1 LE SLAT.SDR 2007UALA04322Bottle · dischargedFLIGHT DIVERTED DUE TO SEVERAL PASSENGERS REQUESTING OXYGEN AND ONBOARD SUPPLIES EXHAUSTED. EARLIER IN FLIGHT AIRCRAFT EXPERIENCED A GRADUAL LOSS OF CABIN PRESSURE, DESCENDED TO FL240, PROBLEM RESOLVED. FLIGHT CONTINUED AT FL360. FOUND CPC MALFUNCTIONED. RESDR 2007UALA04326Door · damagedRIGHT GEAR DOOR DAMAGED, AT TIP SEAL AREA, PART OF TIP SEAL IS MISSING FROM DOOR AND HONEYCOMB IS EXPOSED. REPLACED RIGHT GEAR DOOR.SDR 2007UALA04320Seal · out of positionFLIGHT DIVERTED DUE TO VIBRATION ON AN OVERWING EXIT WINDOW. FLIGHT DIVERTED FOR A SECOND TIME TO ORD UNDER AMBER ALERT DUE TO SAME PROBLEM. 11-01-07 FOUND OVERWING EXIT DOOR SEAL OUT OF PLACE. REMOVED AND REPLACED OVERWING EXIT DOOR SEAL. ACCOMPLISHSDR 2007UALA04356Warning Message · illuminatedELAC 1 PITCH FAULT DISPLAYED ON UPPER ECAM SCREEN. FOUND ELAC1 COMPUTER FAULT. REPLACED ELAC1 COMPUTER- OPS CHECK OK-NO PEPEATS.SDR 2007UALA04303Battery · faultyDURING EMERGENCY LIGHT SYSTEM TEST ON PTP PANEL, TEST FAILED FAULTING LEFT AFT ESPU BATTERY. 11-01-07 REPLACED EPSU.SDR 2007UALA04286Heater · malfunctionedFLIGHT DIVERTED DUE TO CRACKLING/HOT WINDSHIELD & LACK OF FUEL TO REACH PLANNED DESTINATION. 11-01-07 WINDSHIELD CRACKED DUE TO VARIANT HEATING ACROSS THE SURFACE (ELECTRICAL FAILURE) AND SEAL WAS LOOSE AND SLAPPING ACROSS NR 2 WINDOW. REPLACED SLIDING WSDR 2007UALA04304Power Supply · failedEMERGENCY LIGHT SYSTEM TEST FAILED ON PTP PANEL (EPSU AFT L). 11-01-07 FOUND FAULTY EPSU. REPLACED EPSU.SDR 2007UALA04291Smoke Detector · faultyLAVATORY DETECTOR FAULT DISPLAYED ON UPPER ECAM SCREEN, SMOKE. REPLACED LAV A SMOKE DETECTOR- NO MSGS.SDR 2007UALA04250Oxygen System · reads lowLOW CREW OXYGEN PSI. SERVICED CREW O2 SYSTEM FROM 100 PSI TO CORRECT OP PSI. NO REPEATS SINCE ORIGINAL.SDR 2007UALA04251Skin · dentedEXTERNAL FUSELAGE SKIN DENTED STR 41 RT, 14 INCHES FWD OF FRAME 29. ACCOMPLISHED MAJOR REPAIR AT HMV.SDR 2007UALA04252Frame · corrodedCORROSION AT AFT PIT STR 43L FRAME 52 AND 47-51. REPLACED ANGLE AT STR 43L, FR52SDR 2007UALA04253Slide · faultyDOOR 1L SLIDE ASSY AFT ATTACH FITTING BROKEN. REPLACED DOOR 1L SLIDE ASSY.SDR 2007UALA04096Light · inoperativeFOUND ROW 18 AISLE EMERGENCY LIGHT INOPERATIVE. 10-19-07 FOUND LAMP ASSY FAULTED. REPLACED LAMP ASSY - OPS CHECK OK.SDR 2007UALA04081Engine · stalledNR 1 ENG STALL AT FL380 IN SMOOTH AIR. ENGINE RECOVERED QUICKLY. ENGINE REPLACED DUE TO MANY CHRONIC REPORTS OF ENGINE STALLS AND SEVERAL PARTS REPLACED. NO REPEATS SINCE ENGINE CHANGE.SDR 2007UALA04133Bearing · migratedA-C HAD A ROUGH BUFFET WITH FLAPS FULL. ALL OTHER CONFIGURATIONS NORMAL. PROBLEM RECURRED ON FLT 0532-15OCT. INSPECTED NR 1 FLAP CARRIAGE SPHERICAL BEARING FOUND SLIGHTLY MIGRATED BUT AIRWORTHY. OPENED A REPETITIVE INSPECTION PROGRAM TO TRACK THE MIGRATIONSDR 2007UALA04002Computer · faultedELAC 2 FAULT DISPLAYED ON UPPER ECAM SCREEN. 10-19-07 FOUND NR 2 ELAC FAULTY. REPLACED NR 2 ELAC COMPUTER- NO REPEATS.
Back to IAE V2522-A5