Pratt & Whitney Canada PT6A-67B
Service difficulty reports · 880
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PT6A67B' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PT6A67B' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 5APR20120310111Efis · faultyPILOT REPORTS "LT EHSI DISPLAY UNIT IS FUZZY/HARD TO READ." THE LT EHSI PN 066-03125-2500 WAS FOUND TO BE FAULTY. IT WAS R & R WITH A SERVICEABLE UNIT OF THE SAME PN, IAW THE AMM DMC-12-A-34-26-02-00A-920A-A AND TESTED GOOD IAW DMC-12-A-34-26-00-00A-903A-A.SDR 5APR20120307110Efis · faultyPILOT REPORTS LEFT EHSI INTERMITTENT, HAS A BLURRY SCREEN. THE LEFT EHSI, WAS FOUND TO BE FAULTY. R & R WITH A SERVICEABLE UNIT IAW AMM 12-A-34-26-02-00A-920A-A AND TESTED GOOD IAW 2-A-34-26-00-00A-903A-A.SDR 5APR20120224109Display · faultyDURING ROUTINE MX THE PILOTS EADI WAS FOUND TO BE FUZZY. THE EADI DISPLAY PN 066-03125-2500 WAS R & R WITH A SERVICEABLE UNIT OF THE SAME PN IAW MM 12-A-34-26-03-00A-920A-A, AND OPS CHECKED GOOD IAW 12-A-34-26-00-00A-903A-A.SDR CA120222010Aileron Sys · binding(CAN) ON DEPARTURE, ACFT WAS HELD AT A LOWER ALTITUDE FOR APRROXIMATELY 15 MINUTES THROUGH MODERATE TO HEAVY RAIN WITH OAT AT-1C. ACFT LEVELED OUT AT FL 260, OAT -45C, WITH AUTOPILOT ON, PILOT NOTED A SLIGHT SIDE TO SIDE OSCILLATION, WITH SLIGHT ALTITUDE GAINSDR CA120214005Wire · broken(CAN) UNSAFE GEAR INDICATION SHORT DESC: WHILE ON SHORT FINAL LEFT MAIN GEAR INDICATION BEGAN TO FLICKER FROM GREEN TO RED AND THEN REMAINED ON RED. ALTHOUGH HAD PREVIOUS 3 GREEN INDICATION FOR THE APPROACH AFTER SELECTING GEAR DOWN DECIDED TO ABORT THE LANDISDR CA120130009Starter Gen · failed(CAN) ACFT WAS IN CRUISE WHEN A RUMBLING/VIBRATION WAS FELT AND HEARD. THEY ELECTED TO RETURN TO BASE AND AS THEY WERE RETURNING THE NR 1 GENERATOR FAILED. INVESTIGATION SHOWED THAT THE GENERATOR FAN HAD RUBBED AGAINST ITS HOUSING AND WAS IN THE PROCESS OF DESDR 5APR20120120107Display · faultyTHE EHSI WAS REPORTED AS INOPERATIVE. THE EHSI DISPLAY WAS FOUND TO BE FAULTY. THE EHSI DISPLAY WAS R & R USING A SERVICEABLE UNIT OF THE SAME PN IAW AMM12-A-34-26-02-00A-920A-A. THE SYS OPERATIONALLY CHECKED GOOD IAW AMM 12-A-34-26-00-00A-903A-A.SDR 5APR20120119106Eadi · failedTHE NR 2 EADI WAS FOUND TO BE BLOOMING DURING OTHER MX AND NEEDING REPLACEMENT. THE NR 2 EADI PN 066-03125-2500 WAS R & R USING A SERVICEABLE UNIT OF THE SAME PN 066-03125-2500 IAW AMM 12-A-34-26-03-00A-920A-A, OPS CHECKED GOOD IAW AMM 12-A-34-26-00-00A-903A-SDR 5APR20120117105Controller · faultyTHE FLIGHT CREW REPORTED THE AUTO PILOT SYSTEM AS BEING INOP. THE AUTO PILOT MODE CONTROLLER, PN 065-00086-0017 WAS FOUND TO BE FAULTY. IT WAS R & R USING A SERVICEABLE UNIT OF THE SAME PN IAW AMM 12-A-22-10-05-00A-920A-A. THE SYS OPERATIONALLY TESTED GOOD SDR CA120119011Line · loose(CAN) THE OIL LINE THAT ATTACHES TO THE TOP OF THE TORQUE LIMITER LOCATED ON THE FRONT LEFT SIDE OF THE ENGINE BECAME LOOSE AND DISCONNECTED PERMITTING THE LOSE OF ALL ENGINE OIL. THE OIL LINE AND FITTING WAS LAST DISTURBED DURING AN ENGINE CHANGE THAT OCCUREDSDR CA120110004Limiter · leaking(CAN) TORQUE LIMITER UPPER FITTING CAP FOUND TO BE LOOSE CAUSING AN OIL LEAK. LOCKWIRE ON AFT ALLEN KEY SCREW FOUND BROKEN. LOCKWIRE HAD SEAL ON IT. LOCKWIRE WAS .020 AND SEEMED TO SMALL FOR LOCKING OF THE HARDWARE. ATTACHED IPC FIGURE TO SHOW WHICH PIECE WASDR CA120110003Stop · missing(CAN) ELEVATOR UP STOP MISSING. DURING PREFLIGHT INSPECTION IT WAS NOTICED THAT THE ELEVATOR WHEN PULLED FULL UP WOULD STOP AT THE CONTROL COLUMN BEFORE HITTING THE FULL UP STOP. UPON INSPECTION OF THE ELEVATOR CONTROL SYS THE UP STOP WAS FOUND TO BE MISSING.SDR CA120111011Actuator · failed(CAN) DURING A TRAINING FLIGHT AND FOLLOWING TAKEOFF THE RUDDER TRIM MOVED TO THE FULL LT TRIM POSITITION UNCOMANDED. THE AIRCRAFT RETURNED AND CONDUCTED AN OUT OF TRIM LANDING. TROUBLESHOOTING LATER THE FAULT WAS DUPLICATED ON THE GROUND. FOLLOWING THE AUTOPSDR CA120109009Switch · failed(CAN) PILOTS HAD NO LT GEAR DOWN INDICATION, ACFT DIVERTED AND LANDED UNEVENTFULLY. MAINTENANCE DISCOVERED THAT THE GEAR DOWN SWITCH HAD FAILED GIVING A FALSE INDICATION. GEAR ACTUATOR AND SWITCH WERE REPLACED AND OP`S CHECKED NORMAL.SDR 5APR0201210377103Display · faultyTHE COPILOTS EADI WAS REPORTED AS INOPERATIVE. THE COPILOTS EAD, WAS R & R USING A SERVICEABLE UNIT IAW AMM 12-A-34-26-03-00A-920A-A. THE SYS OPERATIONALLY CHECKED GOOD IAW AMM 12-A-34-26-00-00A-903A-A.SDR 5APR2012010177102Relay · faultyPILOTS REPORTED ENROUTE: STAB TRIM FAILURE WHEN MANUALLY TRIMMING UP FROM THE CAPTAINS SEAT AN AURAL WARNING FOLLOWED BY RUNAWAY TRIM. THE STABILIZER TRIM RELAY K022, PN 974.20.01.212 WAS FOUND FAULTY. IT WAS R & R USING A SERVICEABLE RELAY OF THE SAME PN. SDR 5APR2011122977101Relay · faultyCREW REPORTED STAB TRIM FAILURE, RUNAWAY NOSE DOWN ENROUTE TO GMU, THE ACFT LANDED SAFELY. THE STAB TRIM DOWN RELAY WAS FOUND FAULTY, R & R USING A NEW RELAY IAW WDM 27-40-00. THE SYS OPERATIONALLY TESTED GOOD IAW AMM 12-A-27-40-00-00A-903A-A.SDR RMXA2011122893230Tire · failedON APPROACH, JUST AFTER TOUCH DOWN THE RT MAIN TIRE BLEW. THE ACFT CAME TO A COMPLETE STOP WITHOUT DAMAGE. AFTER FURTHER INSPECTION OF THE TIRE, IT WAS NOTED THAT THERE WAS A FLAT SPOT ON THAT TIRE AND HAD SEPARATED AT THE CENTER OF THAT FLAT SPOT. THE LT TISDR 5APR2011122877100Fitting · out of alignmentTHE HORIZONTAL STABILIZER ATTACHMENT FITTING, WHERE THE PITCH TRIM ACTUATOR IS SECURED TO THE STABILIZER. LUGS ARE SEPARATING. THE GAP WAS MEASURED WITH A FEELER GUAGE, AND FOUND TO BE .635MM. THERE IS NO EVIDENCE OF DAMAGE TO THE STABILIZER.SDR 5APR2011121557799Skin · damagedTHE ACFT LEFT WING L/E WAS DAMAGED BY A BIRDSTRIKE. THE DAMAGE WAS OUTSIDE THE GUIDANCE OF THE SRM FOR "ALLOWABLE DAMAGE". TECHNICAL SUPPORT WAS CONTACTED, AN ENGINERING REPAIR MEMO AND "STATEMENT OF APPROVED DESIGN DATA" ECC-12-RM-11-249 WAS ISSED. THE ACFTSDR CA111212010Heater · overheated(CAN) UNDER FLOOR HEATER, OVERHEATED CAUSING SMOKE IN CABIN. HEATER GOT HOT ENOUGH TO START MELTING THE HEATING ELEMENTS. THE THERMAL PROTECTION SWITCH DID NOT SHUT THE HEATER OFF & THE 70AMP CB DID NOT TRIP.SDR CA111213006Relay · fused(CAN) UNDERFLOOR HEATER RELAY K654, FOUND TO HAVE CONTACTS 1 & 2 FUSED TOGETHER.SDR 5APR2011120557798Display · faultyPILOT REPORTED THAT THE PILOTS SIDE EADI, IS FUZZY AND FLICKERS OFF WHEN COLD. PILOTS SIDE EADI WAS R & R USING A SERVICEABLE UNIT IAW AMM 12-A-34-26-03-00A-920A-A AND OPS CHECKED GOOD IAW AMM 12-A-34-26-00-00A-903A-A.SDR CA120206008Starter Gen · failed(CAN) NR 1 GENERATOR FAILED IN FLIGHT, FLIGHT CONTINUED TO DESTINATION ON SECOND GENERATOR POWER, MAINTENANCE FOUND BRUSHES BADLY DAMAGED, STARTER GENERATOR(S/G) REPLACED. SUBSEQUENT TO THIS OCCURANCE AN AUDIBLE NOISE COULD BE HEARD ON ENGINE SHUT DOWN. OIL ANSDR 5APR2011111557797Display · faultyDURING AHRS SWING CHECKS THE NR 2 EHSI WAS FOUND FUZZY AND NEEDING REPLACEMENT. THE NR 2 EHSI WAS R & R WITH A SERVICEABLE UNIT OF THE SAME PN 066-03125-2500 IAW AMM 12-A-34-26-02-00A-920A-A AND TESTED SATISFACTORY IAW AMM 12-A-34-26-00-00A-903A-A.SDR CA111020001Wire · burned(CAN) DURING A MAJOR INSPECTION, COCKPIT WINDSHIELDS WERE REMOVED FOR INSPECTION OF ASSOCIATED STRUCTURE. ON INSTALLATION OF NEW WINDSHIELDS, AIRFRAME WIRE CONNECTIONS FOR THE RT HEATED WINDSHIELD WERE TOO SHORT SO THEY WERE REMOVED FROM THE COCKPIT OVERHEAD SDR 5APR2011101477Y96Motor · faultyTHE VCCS SYSTEM WAS REPORTED AS BEING INOP. THE VCCS COMPRESSOR MOTOR WAS FOUND TO BE FAULTY, IT WAS R & R WITH A SERVICEABLE UNIT OF THE SAME P/N IAW CMM 21-00-23, OPS TESTED GOOD.SDR 5APR20111013095Display · faultyTHE PILOTS EADI SCREEN FAILS INTERMITTENTLY AND IS "BLOOMING". THE EADI DISPLAY WAS FOUND TO BE FAULTY, IT WAS REPLACED WITH A SERVICABLE UNIT IAW AMM DMC-12-A-34-26-03-00A-920A-A AND TESTED SATISFACTORY IAW AMM DMC-12-A-34-26-00-00A-903B-A.SDR 5APR20111005094Fcu · faultyPILOT REPORTS PCL BINDING. THE FCU WAS FOUND TO BE AT FAULT. THE FCU WAS R & R WITH A SERVICEABLE UNIT IAW AMM 12-A-73-20-01-00A-920A-A AND THE EMM 73-20-00, ALL REQUIRED TEST WERE ACCOMPLISHED WITH NO FURTHER DEFECTS NOTED.SDR 5APR20110927001Motor · faultyTHE VCCS SYS WAS REPORTED AS INOP. THE VCCS DRIVE MOTOR, PN 959.90.22.126 WAS FOUND FAULTY. IT WAS R & R WITH A SERVICEABLE UNIT OF THE SAME PN IAW AMM 12-A-21-50-03-00A-313A-A AND CMM 21-00-23. OPS CHECK NORMAL.SDR 5APR20110922001Motor · faultyTHE COOLING UNIT CB KEEPS POPPING. THE COOLING UNIT MOTOR, PN 959.90.22.126 WAS REMOVED, AND A SERVICEABLE UNIT OF THE SAME PN WAS INSTALLED IAW ENVIRO SYSTEMS CMM 21-00-23, THE COOLING SYS WAS TESTED AND FOUND TO OPERATE NORMALLY IAW AMM 12-A-21-50-01-00A-92SDR 5APR20110916001Efis · defectivePILOT REPORTED: CO-PILOTS EADI FLASHING AND INTERMITTENT. THE NR 2 EADI, PN 066-03125-2500 WAS R & R WITH A SERVICEABLE UNIT OF THE SAME PN IAW AMM DMC-12-A-34-26-03-00A-920A-A, OPS CHECK GOOD IAW AMM DMC-12-A-34-26-00-00A-903A-A.SDR 5APR20110915001Efis · defectivePILOT REPORTED COPILOTS EADI IS INOP. REMOVED ED462, PN 066-03125-2500, INSTALLED SERVICEABLE EXCHANGE ED462 UNIT OF THE SAME PN, SYS OPS CHECK GOOD IAW AMM CH 12-A-34-26-03-00A-920A-A.SDR 5APR577Y88Sensor · faultyPILOT REPORTS THAT BATTERY NR1 INDICATES CONTINUOUS 457 AMP DISCHARGE WITH NO DEPLEATION OF VOLTAGE. THE BATTERY NR 1 CURRENT SENSOR PN 524.52.12.720 WAS R & R IAW AMM 12-A-24-30-08-00A-920A-A.SDR 5APR577Y87Sensor · faultyPILOT REPORTS OVERHEAD PANEL DISPLAY READS 570 AMP CURRENT DRAW UPON TURNING ON NR1 BATTERY SWITCH. R & R BATTERY NR 1 CURRENT SENSOR PN 524.52.12.720 IAW AMM DMC-12-A-24-30-08-00A-920A-A. OPS CHECK NORMAL.SDR 5APR20110904001Disk · crackedTHE LT BRAKE ASSEMBLY WAS INSPECTED DURING A LINE CHECK AND FOUND TO HAVE A CRACKED ROTOR. THE LT BRAKE ASSEMBLY WAS R & R USING A SERVICEABLE UNIT OF THE SAME PN-959.56.01.512 IAW AMM 12-A-32-40-03-00A-920B-A.SDR 5APR20110902001AMotor · faultyVCCS SYS REPORTED AS INOPERATIVE, FANS BLOWING BUT AIR IS NOT COLD. THE VCCS COMPRESSOR MOTOR WAS FOUND FAULTY AND WAS R & R WITH SERVICEABLE UNIT OF THE SAME PN 959-90-22-126, IAW CMM 21-00-23 AND AMM 12-A-21-50-01-00A-920B-A.SDR 5APR577Y86Blades · erodedDURING A ROUTINE HOT SECTION BOROSCOPE INSP, SEVERAL COMPRESSOR TURBINE BLADES WERE FOUND TO HAVE EROSION THAT EXTENDED INTO THE BLADE TIPS. ENGINE PERFORMANCE RUNS AS WELL AS CURRENT ECTM GRAPHS WERE NORMAL, NO HOT SECTION DETERIORATION WAS OBSERVED. THE POSDR 5APR20110829001Blades · erodedDURING A ROUTINE HOT SECTION BOROSCOPE INSP, SEVERAL COMPRESSOR TURBINE BLADES WERE FOUND TO HAVE EROSION THAT EXTENDED INTO THE BLADE TIPS. ENGINE PERFORMANCE RUNS AS WELL AS CURRENT ECTM GRAPHS WERE NORMAL, NO HOT SECTION DETERIORATION WAS OBSERVED. THE POWSDR 5APR20110820001Brake Disc · crackedTHE RT BRAKE WAS INSPECTED DURING A LINE CHECK AND FOUND TO HAVE A CRACKED ROTOR. THE RT BRAKE ASSEMBLY WAS R & R USING A SERVICEABLE UNIT OF THE SAME PN 959.56.01.512 IAW AMM 12-A-32-40-03-00A-920B-A.SDR CA110822005Actuator · inoperative(CAN) CREW REPORTED "A/P TRIM" MASTER WARNING FOLLOWED BY AN A/P DISCONNECT EVENT DURING DESCENT TO DESTINATION AIRPORT. AUTO PILOT WOULD NOT RESET/TEST. MX REVEALED A FAILURE OF THE ALTERNATE-AUTO TRIM PORTION OF THE STAB TRIM ACTUATOR ASSY. MAIN TRIM PORTISDR 5APR577Y81Attach Fitting · out of alignmentTHE HORIZ STABILIZER ATTACHMENT FITTING, WHERE THE PITCH TRIM ACTUATOR IS SECURED TO THE STABILIZER. EACH SIDE OF THE ATTACHMENT FITTING HAS 2 LUGS. ON THE LT SIDE, THESE 2 LUGS ARE SEPARATING. THE GAP WAS MEASURED WITH A FEELER GUAGE, AND FOUND TO BE .406MMSDR 5APR577Y78Sensor · faultyBEFORE DEPARTURE, CREW REPORTED ESSENTIAL BUSS-BATTERY CAWS & AURAL WARNING ON START. BATT 1 VOLTS FLUCTUATE BTW 17.5 AND 21.5, BATTERY 2 BTW 18.5 AND 23.5 AMPS ON BOTH -020 -002. CONFIRMED SECURITY OF RELAY K221 WITH NO DISCREPANCY'S. CONFIRMED SECURITY OF SDR 5APR577Y76Proximity Sensor · faultedAFTER DEPARTING, THE FLIGHT CREW WAS UNABLE TO MOVE THE LANDING GEAR HANDLE TO THE UP POSITION. THE ACFT RETURNED TO DEPARTURE AND LANDED SAFELY. THE ACFT FERRIED FOR MX. A FAULTY LT GEAR UP PROXIMITY SENOR WAS FOUND DURING TROUBLESHOOTING. THE SENSOR WASSDR 5APR577Y75Connector · damagedTHE PILOT REPORTED TORQUE INDICATION DROPPED OFF TO 0.2 - 0.3 PSI IMMEDIATELY AFTER ROTATION. THE ACFT CONTINUED CLIMBOUT, THE CREW INFORMED ATC THEY WERE RETURNING TO DEPARTURE AND LANDED SAFELY. REMOVED, CLEANED AND REINSTALLED TORQUE PRESSURE TRANSMITTSDR 5APR577Y74Unknown · odorAFTER DEPARTING, THE PILOT’S EADI WENT OUT AND THE AUTO PILOT DICONNECTED. THERE WAS A SMELL OF ELECTRICAL SMOKE EMANATING FROM THE AUTO PILOT CONTROLLER AREA. O2 MASKS WERE DONNED AND DEPARTURE WAS NOTIFIED THAT THEY WERE RETURNING WITH SMOKE IN THE COCKPIT. SDR CA110706009Latch · strippedTHE FWD LOWER LATCH ASSY FAILED DUE TO THE INTERNAL THREADS IN THE ALUMINUN FITTING PULLING OUT. THE METAL THREADS ON THE STUD HAVE NO APPARENT WEAR, HOWEVER THE THREADS IN THE FITTING ARE BEYOND LIMITS. IT IS ONLY UNDER LOAD THRU THE CAM ACTION OF LOCKING SDR 5APR577Y72Brake Disc · crackedTHE RT BRAKE WAS INSPECTED DURING A LINE CHECK AND FOUND TO HAVE A CRACKED ROTOR. THE RT BRAKE ASSY WAS R & R WITH A SERVICEABLE O/H UNIT OF THE SAME PN 959.56.01.512 IAW AMM 12-A-32-40-03-00A-920B-A.SDR CA110711004Engine · overtorqued(CAN) IFSD, SINGLE ENGINE, DURING CLIMB, THE ENGINE TORQUE INCREASED UNCOMMANDED TO APPROXIMATELY 52.2 PSI. THE PILOT REPORTED NO PLA RESPONSE AND SUBSEQUENTLY SHUTDOWN THE ENGINE AND MADE AN UNEVENTFUL EMERGENCY DEAD-STICK LANDING AT POINT OF DEPARTURE. FDRSDR 5APR577Y71Proximity Switch · faultyCREW REPORTED NOSEWHEEL INDICATOR DOWN/LOCK INOP. VISUAL CONFIRMATION WAS NEEDED TO CONFIRM GEAR WAS DOWN AND LOCKED. THE NLG "DOWN" PROXIMITY SWITCH WAS FOUND TO BE FAULTY. IT WAS R & R WITH A SERVICEABLE PN 973.30.33.111. THE LANDING GEAR EXTENSION RETRACTI
Back to Pratt & Whitney Canada PT6A-67B