SDR SWIA200211075Ballast · defectiveWHILE ON THE GROUND WITH APU ON, SMELLED STRONG SMOKE FROM AFT GALLEY AREA (NO VISUAL SMOKE). SMELLED LIKE BURNING PLASTIC. SMELL ISOLATED TO GALLEY LIGHT WHICH HAD APPARENTLY BURNED OUT. REMOVED AND REPLACED BALLAST WITH SERVICEABLE UNIT. OPS CHECK GOOD. SDR AUS20020735Valve · failed(AUS) GREEN HYDRAULIC SYSTEM FILL CHECK VALVE CRACKED AND LEAKING.VALVE IS LOCATED IN THE AREA OF THE RH ENGINE NACELLE.SDR AUS20020821Filter · dirty(AUS) RH ENGINE FUEL FILTER LIGHTLY CONTAMINATED.SDR SWIA200211033Connector · faultyAFTER TAKEOFF AT 100 AGL, RECEIVED AN AURAL OIL WITH TRIPLE CHIME. NO ASSOCIATED MAP WARNINGS AND NO ENGINE PARAMETERS TO SUPPORT THE WARNING. ALARM WAS CONTINUOUS AND COULD NOT BE CANCELLED. RETURNED TO SLC. REMOVED AND REPLACED OIL PRESSURE TRANSDUCER CASDR SWIA200211005Indicator · burned outFIRST OFFICER'S EHSI SCREEN BURNED OUT. REPLACED FIRST OFFICER'S EHSI SCREEN. OPS CHECK GOOD.SDR GLBA2002094Filter · restrictedLEFT FUEL FILTER ANNUNCIATOR ILLUMINATED AT 25 - 30 PERCENT TQ. REPLACED HIGH AND LOW PRESSURE FUEL FILTERS OPS CHECKED SATISFACTORYSDR SWIA200210939Fuel Line · crackedAFTER TAKEOFF FUEL DISCOVERED LEAKING FROM RIGHT ENGINE. ENGINE SHUTDOWN AND AIRCRAFT RETURNED TO THE FIELD. FOUND CRACKED FUEL LINE AT HMU. REPLACED LINE. LEAK CHECK GOOD. REMOVED AND REPLACED HMU FUEL RETURN HOSE IAW EMB POWERPLANT BUILDUP 71-00-00. OPSDR SWIA200210921Bracket · crackedFORWARD CARGO DOOR TRACK SUPPORT BRACKET ON FRAME 40 CRACKED. INSTALLED A NEW BRACKET IAW EMBRAER DER APPROVAL GST 1880/02.SDR SWIA200210916Computer · malfunctionedAUTOPILOT/YAW FAILURE IN FLIGHT. INSTALLED SERVICEABLE AHC85 COMPUTER. OPS CHECKS GOOD. CAPTAIN'S COMPUTER AND GYRO FLAGS ARE INTERMITTENT IN FLIGHT. INSTALLED SERVICEABLE AHC85 COMPUTER. OPS CHECKS GOOD.SDR SWIA200210917Proximity Sensor · malfunctionedTAKEOFF AURAL WARNING TRIM SOUNDED ON START OF TAKEOFF ROLL. ABORTED TAKEOFF AND RETURNED TO GATE. RESET AURAL WARNING SYSTEM. OPS CHECKS GOOD. AURAL TRIM WARNING WILL NOT STOP. REPLACED PROXIMITY SENSORS. OPS CHECK GOOD.SDR SWIA200210907Connector · contaminatedEEC FAILED ON TAKEOFF ROLL, EEC AURAL WARNING. UNABLE TO DETERMINE WHICH EEC FAILED. ABORTED TAKEOFF. FOUND OIL CONTAMINATION IN CONNECTOR P0305. CLEANED AND RESECURED CONNECTOR. SWAPPED EEC AND TORQUE SIGNAL CONDITIONER WITH RIGHT ENGINE. RAN ENGINES. SDR SWIA200210908Pin · out of positionRIGHT LANDING GEAR DOOR WOULD NOT RETRACT AFTER TAKEOFF. RETURNED TO GJT. DISCOVERED LATCH PIN WAS BROKEN, LEFT SIDE OF RIGHT MAIN GEAR DOOR. FOUND AFT LATCH SAFETY PIN CAME OUT. RESAFETIED AND LATCHED DOOR. OPS CHECK GOOD. REINSPECTED BY SLC CHECKS GOODSDR SWIA200210906Indicator · erraticLEFT ENGINE T6 GAUGE ERRATIC. RETURNED TO DEN. REPLACED LEFT T6 GAUGE. OPS CHECK GOOD.SDR AUS20021020Door · separated(AUS) RH HYDRAULIC BAY ACCESS DOOR MISSING. DOOR HAD OPENED IN FLIGHT AND HAD TORN AWAY FROM PIANO HINGE.SDR SWIA200210898Inverter · failedINVERTER NR 1 WENT INOP EN ROUTE AND WOULD NOT RESET. RETURNED TO DEN. REMOVED AND REPLACED NR 1 INVERTER. OPS CHECK GOOD. INSTALLED SERVICEABLE INVERTER IAW MM 24-20-01. OPS CHECK GOOD. FURTHER INVESTIGATION IN PROGRESS.SDR AUS20020508Control Box · faulty(AUS) ANTISKID CONTROL BOX FAULTY.SDR SWIA200210882O-Ring · leakingNR 1 ENGINE SMOKING HEAVILY FROM THE TOP OF THE COWL AFTER SHUT DOWN. FUEL WAS DRIPPING FROM UNDERNEATH THE ENGINE. FOUND FUEL NOZZLE (9 O'CLOCK POSITION) TRANSFER TUBES NOT SEATED. REPLACED O-RINGS ON TRANSFER TUBES AND SEATED. PERFORMED LEAK CHECK. LEAKSDR AUS20020640Bearing · corroded(AUS) ENGINE REDUCTION GEARBOX BEARINGS NR 15 AND NR 19 PITTED. METAL CONTAMINATION OF FILTER. SUSPECT FAILURE DUE TO STATIC DISCHARGE.SDR SWIA200210798Relay · failedRIGHT EEC FAILED. ABORTED TAKEOFF. REPLACED RIGHT ENGINE REVERSION RELAY. ALL OPS CHECKS GOOD.SDR SWIA200210774Pump · malfunctionedRIGHT ENGINE SLUGGISH IN ACCELERATION. T6 WAS ABOUT 820 DEGREES USING TORQUE SETTINGS SUPPLIED ON THE RELEASE. REMOVED AND REPLACED RIGHT ENGINE FUEL PUMP AND HMU IAW MM 73-21-00. RUN CHECKS AND LEAK CHECKS GOOD. HMU: P/N: 786390-10, S/N OFF: F1829.SDR SWIA200210750Seal · defectiveON TAKEOFF RECEIVED A RIGHT ENGINE OIL PRESSURE WARNING. OIL PRESSURE RETURNED BACK IN THE GREEN ARC AND FLUCTUATED BETWEEN 60 & 50 PSID. OIL PRESSURE DROPPED BACK OFF AGAIN WITH ASSOCIATED WARNINGS. OIL PRESSURE STABILIZED AT 63 PSID ON DOWNWIND RETURNING SDR SWIA200210725Pressure Switch · defectiveIN CLIMBOUT THROUGH FL20, THE LEFT POWER LEVER WOULD NOT RESPOND TO THROTTLE INPUT. SWITCHED THE LEFT EEC TO MANUAL AND THE ENGINE REQUIRED POWER. SELECTED MANUAL ON THE RIGHT ENGINE EEC AND RETURNED TO DEN. REMOVED AND REPLACED LEFT 14,000 FT PRESSURE SWITSDR SWIA200210675Oil System · lowLOW OIL PRESSURE LIGHT ILLUMINATED FOR NR 2 ENGINE ON TAKEOFF ROLL. ABORTED TAKEOFF. ADDED 3 QUARTS TO NR 2 ENGINE. UPON INSPECTION NO OIL LEAKAGE FOUND.SDR AUS20020147Cable · split(AUS) LH ENGINE IGNITION CABLE FROM HIGH ENERGY IGNITION UNIT (HEIU) TO IGNITER PLUG CHAFED THROUGH REINFORCED OUTER LAYER THROUGH TO THE INNER LAYER DUE TO RUBBING AGAINST THE FIREWALL AND OTHER ENGINEMOUNTED COMPONENTS.SDR SWIA200210529Wire Harness · faultyRT NP GAUGE FLUCTUATES IN FLIGHT. REMOVED AND REPLACED RIGHT ENGINE EEC WIRING HARNESS. OPS CHECKS GOOD.SDR AUS20011346Fitting · misinstalled(AUS) RT ENGINE BLEED AIR PRESSURE REGULATING VALVE FITTING / PIPE CONNECTION CROSS THREADED. PERSONNEL/MAINTENANCE ERROR.SDR AUS20011308Connector · corroded(AUS) BOTH OUTBOARD TRAILING EDGE FLAP ACTUATOR CONNECTORS CORRODED.SDR AUS20011180Skin · corroded(AUS) AFT FUSELAGE LOWER SKIN CORRODED IN AREA OF SUB ZONE 250 BETWEEN BS 13255 AND BS 13630. AREA OF CORROSION APPROXIMATELY 645.16SQMM (10SQIN). EVIDENCE OF SOME SMALL PIN HOLES.SDR SWIA200110263Switch · dirtyFORWARD DOOR LIGHT ILLUMINATED ON TAKEOFF. RETURNED TO GATE. REMOVED TRASH FROM DOOR MICROSWITCH. RESET BREAKER AND REPLACED BULBS. OPS CHECK GOOD.SDR AUS20011115Flap · faulty(AUS) AIRCRAFT EXPERIENCED FLAP ASYMMETRIC FAULT. INVESTIGATION COULD FIND NO CAUSE FOR THE DEFECT.SDR SWIA200110245Fcu · out of adjRIGHT TORQUE FLUCTUATED 5 - 8 PERCENT AFTER TAKEOFF. RETURNED TO FAT. PERFORMED ENGINE RUNS IAW EMB 120 MM 71-00-00. OPS CHECKS GOOD. NO DEFECTS NOTED AT THIS TIME. UPDATE 10/12/2001: PREVIOUS OPS CHECK DONE WITH EECS OFF. RAN AND ADJUSTED TRIM ON RIGHTSDR AUS20011069Balance Weight · corroded(AUS) LT AND RT AILERON INBOARD, CENTRE AND OUTBOARD BALANCE WEIGHTS CORRODED. FOUND DURING INSPECTION IAW AD/EMB120/24 PT2. (SB 120-27-077 PT2).SDR AUS20011070Balance Weight · corroded(AUS) LT AND RT AILERON INBOARD, CENTRE AND OUTBOARD BALANCE WEIGHTS CORRODED. FOUND DURING INSPECTION IAW AD/EMB120/24 PT2. (SB 120-27-077 PT2).SDR SWIA200110233Sensor · reads highRIGHT EEC FAILED ON TAKEOFF. MANUAL AND RED EEC LIGHT ILLUMINATED. PERFORMED ENGINE RUNS FOR 20 MINUTES IN TAKEOFF AND CRUISE CONFIGURATIONS, NO DEFECTS NOTED. CLEANED AND OHMED ALL EEC CANNON PLUGS. FOUND NP SENSOR HIGH. REMOVED AND REPLACED RT ENGINE NP SDR AUS20011015Inverter · failed(AUS) NR 1 AND 2 MAIN INVERTERS FAILED.SDR SWIA200110157Eec · malfunctionedABORTED TAKEOFF IN WYS DUE TO LEFT ENGINE SURGE +/- 45 PERCENT. PERFORMED ENGINE RUNS. DEFERRED LEFT EEC.RAN LEFT ENGINE TO TAKEOFF POWER WITH NO FLUCTUATIONS NOTED. ALL CHECKS GOOD AT THIS TIME.SDR SWIA200110122Hmu · malfunctionedLEFT ENGINE TORQUE SURGE FROM 71% TO 100% WITH ASSOCIATED YAW ON TAKEOFF.REMOVED AND REPLACED HMU AND FUEL PUMP PER EMB120 MM 73-21-00, 73-13-00. RAN LEFT ENGINE PER 71-00-00. OPS CHECK GOOD. NO LEAKS NOTED.SDR SWIA200110115Connector · contaminatedFLAP DISAGREEMENT WHEN FLAPS BROUGHT UP FROM 15 DEGREES ON TAKEOFF (HAPPENED REPEATEDLY) THEN GOES AWAY. CLEANED OUTBOARD FLAP ACTUATOR CANNON PLUGS. TESTED FLAP. NO FAULTS.SDR SWIA200110133Sequence Valve · out of adjUPON GEAR RETRACTION, LEFT MAIN GEAR REMAINED DOWN WITH BOTH A AND B RED AND GREEN LIGHTS ILLUMINATED. RECYCLED GEAR DOWN WITH NORMAL INDICATIONS. CYCLED GEAR UP AND LEFT MAIN AGAIN REMAINED DOWN, THIS TIME WITH RIGHT RED A AND B LIGHTS ILLUMINATED AND THEN SDR SWIA200110107Engine · malfunctionedRIGHT ENGINE WOULD NOT POWER UP FOR TAKEOFF. RAN BOTH ENGINES THROUGH ALL PARAMETERS WITH EEC'S ON AND ALSO WITH EEC'S OFF. NO FAULTS NOTED. OPS CHECK GOOD.SDR SWIA200110111Warning Light · illuminated''TRIM FAIL'' LIGHT ON MAP ILLUMINATED ON TAKEOFF ROLL. MEL 22-10-1A, MC 021OPERATED TRIM SEVERAL TIMES FULL RANGE. OPS CHECK GOOD ON GROUND.SDR AUS20010913Power Supply · faulty(AUS) FLAP ANNUNCIATOR UNIT FAULTY. SUSPECT POWER SUPPLY PROBLEM.SDR SWIA200110097Control Unit · malfunctionedFLAP CONTROL FAULT (NACELLE PAIR) AFTER SELECTING FLAPS 25. RESET OK BUT ALSO HAPPENED WHEN SITTING ON GROUND WITH FLAPS UP.REPLACED FLAP CONTROL UNIT PER MM 27-50-06. OPS CHECK GOOD AND INDICATION CHECK GOOD.SDR SWIA200110113Engine · malfunctionedON APPROACH, LEFT ENGINE EXPERIENCED A SEVERE POWER LOSS. TRIPLE CHIME ''ENGINE CONTROL'' AND WHITE ''MANUAL'' LIGHT ILLUMINATED. INITIATED A GO-AROUND TO AVOID TERRAIN CONTACT. ON GO-AROUND, REGAINED SOME POWER ON LEFT ENGINE. BROUGHT POWER BACK TO LEVELSDR AUS20010881Roller · worn(AUS) RT OUTBOARD FLAP JAMMED. INVESTIGATION FOUND ALL FOUR ROLLERS WORN AND FLAP TRACK SCORED WITH RAISED METAL AREAS.SDR AUS20010854Control Unit · faulty(AUS) FLAP DISAGEEMENT ON RETRACTION. FLAP OPERATING SYSTEM INSPECTED AND NIL FAULT FOUND.SDR AUS20010806Reservoir · leaking(AUS) LOSS OF FLUID FROM GREEN HYDRAULIC SYSTEM. SUSPECT CAUSED BY INCORRECT BRAKING SEQUENCE.SDR SWIA200110065Battery · dischargedEMERGENCY LIGHTS WOULD NOT TEST PROPERLY. REMOVED AND REPLACED FORWARD, MID AND AFT ELBP'S IAW 33-50-02. OPS CHECK GOOD.SDR AUS20010791Connector · contaminated(AUS) RT OUTBOARD FLAP ACTUATOR ELECTRICAL CONNECTOR CONTAMINATED WITH MOISTURE.SDR ASOA01116SBlade · fracturedFLT 4830 - DURING FLIGHT FROM DFW TO TUL, CREW REPORTED SMELLING SMOKE IN THE CABIN. AFTER ISOLATING THE RT BLEED AND RT PACK THE SMOKE DIDN'T CLEAR. RECEIVED A RT ENGINE LOW OIL PRESSURE WARNING AND THE GAUGE WAS FLUCTUATING. THE RT ENGINE OIL PRESSURE DROP
Back to Pratt & Whitney Canada PW118A