Pratt & Whitney Canada PW118A
Service difficulty reports · 903
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW118A' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW118A' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA200312003Uplock Sensor · malfunctionedUPON DEPARTURE, LANDING GEAR WOULD NOT RETRACT. SYSTEM A & B SHOWED DISAGREEMENT, WITH THE EXCEPTION OF SYSTEM A, LEFT MAIN GEAR. RAN QRH, NO RESULTS, CYCLED GEAR, NO RESULTS, PULLED & RESET LANDING GEAR CB, GEAR RETRACTED.REMOVED AND REPLACED ''A'' UPLOCK PSDR SWIA200311931Sequence Valve · malfunctionedGEAR RETRACTION NORMAL. IN FLIGHT THE B-DISAGREEMENT LIGHTS ILLUMINATED FOR ABOUT 15 SECONDS. UPON GEAR EXTENSION, THE LEFT AND NOSE GEAR EXTENDED NORMALLY, THE RIGHT GEAR REQUIRED ABOUT 7 SECONDS BEFORE THE DISAGREEMENT LIGHT EXTINGUISHED. REPLACED RIGHT MSDR SWIA200312015Floorbeam · corrodedCORROSION ON LEFT INBOARD FLOORBEAM AND SEAT TRACK AT FORWARD END OF SEAT TRACK. FOUND DURING C-CHECK INSPECTION. REPAIRED CORROSION ON LEFT INBOARD FLOORBEAM AND SEAT TRACK AT FORWARD END OF SEAT TRACK. REPAIRED FLOORBEAM IAW SRM 53-00-03 AND REPAIRED SEATSDR SWIA200312019Clip · crackedLEFT AND RIGHT FRAME 9 CLIPS CRACKED IN COCKPIT. FOUND DURING C-CHECK INSPECTION. COMPLIED WITH SB 120-53-0073.SDR SWIA200311890Actuator · failedAFTER TAKEOFF, DISCOVERED WE HAD VERY LIMITED RIGHT RUDDER AUTHORITY. RIGHT RUDDER PEDAL WOULD ONLY DEPRESS ABOUT 1 1/2 INCHES. LEFT PEDAL TRAVEL NORMAL AND ALL COCKPIT INDICATIONS NORMAL. INSPECTED RUDDER FOR FREEDOM OF MOVEMENT, CHECKED GOOD. BLUE SYSTEMSDR SWIA200311832Wire Harness · damagedAFTER TAKEOFF AND GEAR RETRACTION, RECEIVED GEAR INDICATIONS, LOUD NOISE AND VIBRATION FROM THE NOSE THAT INCREASED WITH AIRSPEED. RETURNED TO LAX. PERFORMED GEAR RETRACTION. FOUND THAT GEAR DOORS WOULD NOT CLOSE DUE TO A FAULTY NOSE GEAR A-HARNESS. REMOVESDR SWIA200311833Connector · damagedFLAP CONTROL FAULT INDICATED FOR INBOARD FLAPS. FLAPS WOULD NOT RETRACT ON THE GROUND. REMOVED AND REPLACED CONNECTOR FOR LEFT INBOARD FLAP ACTUATOR WITH A NEW PART. OPS CHECK OF FLAPS PERFORMED SATISFACTORY. P/N ON MS3476L12-10S.SDR 74451Bearing Race · crackedCRACK IN RACESDR 0074451Bearing Race · crackedCRACK IN RACE.SDR SWIA200311791Engine · overspeedAFTER LANDING ROLLOUT AND DURING DECELERATION, HEARD A TRIPLE CHIME WARNING AND THE AURAL WARNING ENGINE CONTROL WHICH STARTED AT ABOUT 90 KTS. AT ABOUT 70 KTS, THE RIGHT ENGINE SURGED SEVERAL TIMES RESULTING IN MODERATE INCREASING YAWING TENDENCIES. POSITIVSDR SWIA200311790Connector · contaminatedFLAP DISAGREEMENT ON FLAP RETRACTION ON TAKEOFF, OUTBOARD FLAPS. RETURNED TO SLC. INSPECTED OUTBOARD FLAPS CONNECTORS, FOUND GLYCOL IN LEFT OUTBOARD CONNECTOR. CLEANED LEFT OUTBOARD CONNECTOR AND RAN FLAPS 10 CYCLES. OPS CHECK GOOD. NO FAULTS AT THIS TIMESDR AUS20030411Wire Harness · worn(AUS) LEFT FORWARD BOOST PUMP LOOM CHAFED AGAINST RIGID FUEL LINE PN 120-08735-047 LOCATED IN THE TANK. LOOM INCORRECTLY ROUTED.SDR SWIA200311792Actuator · malfunctionedRIGHT MAIN GEAR WOULD NOT COMPLETELY RETRACT. RED LIGHTS (BOTH) STAYED ON. CYCLED TWICE, WOULD NOT RETRACT. RETURNED TO LAX. REPLACED RIGHT MAIN LANDING GEAR ACTUATOR WITH SERVICEABLE IAW MM 32-32-10. PERFORMED GEAR SWING IAW MM 32-30-00. OPERATIONAL CHESDR GLBA2003010Hose · damagedLEFT ENGINE PRESS FLUCTUATING BELOW 40 PSI. INSTALLED OIL COOLER HOSE, OPS CHECK GOOD.SDR AUS20030006Line · leaking(AUS) APU FUEL LINE LOCATED BETWEEN THE FCU AND FUEL SHUTOFF VALVE FITTED BACK TO FRONT AND LEAKING FROM UNIONS. PIPE WAS ALSO FOULING ON THE APU CASING.SDR AUS20030128Annunciator · wrong part(AUS) INCORRECT ANNUNCIATOR ASSEMBLY FITTED. PN 80054141 WAS FITTED INSTEAD OF THE CORRECT PN 80054153. UNAPPROVED/INCORRECT PART. PERSONNEL/MAINTENANCE ERROR.SDR SWIA200211502Signal Cond Unit · malfunctionedNR 2 PROPELLER FEATHERED WHEN TAKEOFF POWER APPLIED. TORQUE REACHED 125 PERCENT INSTANTANEOUSLY. NP 18.9 PERCENT WHEN POWER BROUGHT BACK TO IDLE. REPLACED RIGHT ENGINE TORQUE SIGNAL CONDITIONER IAW EMB MM 77-11-01. OPERATIONAL CHECKS GOOD. REPLACED NR 2 ESDR AUS20021414Pipe · chafed(AUS) RT HYDRAULIC RESERVOIR RETURN LINE LOCATED IN THE RT NACELLE/FLAP BAY WAS FOUND CHAFED THROUGH BY AN ADJACENT ELECTRICAL LOOM PROTECTIVE CONDUIT. PERSONNEL/MAINTENANCE ERROR.SDR AUS20021348Sleeve · damaged(AUS) LH AIRCONDITIONING PACK ASSEMBLY LEAKING. INVESTIGATION FOUND THREE PIPELINE SLEEVE CONNECTORS SUSPECT FAULTY.SDR SWIA200211510Flow Divider · malfunctionedON TAKEOFF ROLL BELOW 80 KTS, THE LT ENGINE SHUT DOWN. ABORTED THE TAKEOFF. REMOVED AND REPLACED LT ENGINE FLOW DIVIDER. RAN ENGINE. SYSTEM OPS CHECK AND LEAK CHECK GOOD IAW EMB120 MM 73-14-00 & P&W MM.SDR SWIA200211465Pump · malfunctionedDURING TAKEOFF THE RT ENGINE WOULD ONLY PRODUCE 91 PERCENT TORQUE AT FULL POWER. LT ENGINE NORMAL 100 PERCENT TORQUE. FUEL FLOW ON THE RT ENGINE 100 LBS LESS THAT OF THE LEFT ENGINE. ABORTED TAKEOFF. INSTALLED SERVICEABLE HMU AND FUEL PUMP. OPS CHECK GOODSDR SWIA200211649Frame · crackedFRAME 13 RT AND LT SIDE INBOARD AND OUTBOARD, PREVIOUS REPAIRS CRACKED OUTBOARD SIDE. CRACK GOES BEYOND DOUBLER ON THE RIGHT SIDE. FOUND DURING C-CHECK INSPECTION. FABRICATED AND INSTALLED DOUBLERS TO CRACKED AREAS IAW EMB SRM 51-00-00 AND 51-40-02.SDR SWIA200211650Bracket · crackedLEFT HYDRAULIC RESERVOIR INBOARD VERTICAL BRACKET MOUNTING HAS 3 INCH + VERTICAL CRACK INSIDE THE BRACKET. FOUND DURING C-CHECK INSPECTION. REMOVED VERTICAL MOUNTING BRACKET AND INSTALLED NEW HYDRAULIC RESERVOIR MOUNTING BRACKET IN ITS PLACE IAW EMB SRM 51-4SDR AUS20021314Actuator · worn(AUS) LH AIRCONDITIONING SYSTEM RAM AIR ACTUATOR AFT MOUNT WORN THROUGH ALLOWING ACTUATOR TO DISCONNECT. RAM AIR VALVE PARTIALLY CLOSED RESTRICTING COOLING AIR FLOW THROUGH THE HEAT EXCHANGER AND CAUSING THE AIRCONDITIONING PACK TO SHUT DOWN DUE TO OVERHEATINGSDR AUS20021285Oil System · low(AUS) LT ENGINE OIL QUANTITY BELOW MINIMUM LEVEL. PERSONNEL/MAINTENANCE ERROR.SDR SWIA200211414Connector · contaminatedFLAP DISAGREEMENT THAT WOULD NOT CLEAR AFTER TAKEOFF. RETURNED TO SLC. DEICE FLUID FOUND IN OUTBOARD FLAP ACTUATOR CONNECTOR PLUGS. CLEANED CONNECTOR PLUGS. OPS CHECK GOOD AT THIS TIME.SDR SWIA200211432Outflow Valve · malfunctionedAUTO PRESSURIZATION UNABLE TO CONTROL PRESSURE. CONTRACT MAINTENANCE PERFORMED MX PROCEDURE FOR DEFERRAL. NEXT FLIGHT RETURNED TO GJT WITH MANUAL PRESSURIZATION INOPERATIVE REMOVED AND REPLACED ELECTRO OUTFLOW VALVE IAW MM 21-30-03. OPS CHECK GOOD.SDR AUS20021246Engine · bird ingestion(AUS) LT ENGINE CONTAINED EVIDENCE OF BIRD STRIKE. INSPECTION COULD FIND NO DAMAGE. FOLLOWING INSPECTION AND WATER WASH A GROUND RUNWAS CARRIED OUT WITH ALL INDICATIONS NORMAL. ENGINE WILL BE MONITORED FOR ANY DETERIORATION.SDR AUS20021263Contactor · unserviceable(AUS) BATTERY CONTACTOR SUSPECT FAULTY. WIRES W010-0013-24 ANDW010-0038-24 BURNT. INVESTIGATION FOUND THE BATTERY CONTACTOR K0455 PNO 170GC02-500 HAD A DISLODGED LEAF CONTACT ON TERMINAL S. THE LOOSE TERMINAL SHORT CIRCUITED CAUSING EXCESS CURRENT INWIRES.SDR AUS20021383Bearing · failed(AUS) NOSE LANDING GEAR STRUT LOWER BEARING FAILED. DELRIN' INNER LINER DISLODGED DUE TO ADHESIVE FAILURE.SDR SWIA200211352Relay · malfunctionedON TAKEOFF ROLL WE RECEIVED A RIGHT ENGINE EEC, ENGINE CONTROL WARNING. ABORTED TAKEOFF AND RETURNED TO GATE. REMOVED AND REPLACED RIGHT ENGINE REVERSION RELAY. RAN ENGINE. OPS CHECK GOOD.SDR AUS20021190Seal · leaking(AUS) NO2 ENGINE REDUCTION GEARBOX AUXILIARY GENERATOR OIL SEAL LEAKING. SEAL HAD BEEN CHANGED ON THE PRECEDING DAY.SDR AUS20021107Engine · vibrates(AUS) SEVERE ENGINE VIBRATION DURING START. LIMITED INFORMATION PROVIDED.SDR SWIA200211399Frame · crackedLT AND RT NACELLE FRAME NR 1 FOUND CRACKED AT TORSION MOUNT AREA. FOUND DURING C CHECK INSPECTION.COMPLIED WITH PART II OF SB 120-54-0036. REPLACED RIGHT AND LEFT FRAME NR 1 WITH SERVICABLE UNITS.SDR SWIA200211257Engine · power lossLARGE SPLIT IN POWER LEVERS ON TAKEOFF ROLL AND AT 100 FT NR 2 NP DROPPED TO ABOUT 50 PERCENT, THE TQ STAYED AT 100 PERCENT. ON DOWNWIND, TQ DROPPED TO 0 PERCENT, NP INCREASED TO 100 PERCENT. WE FEATHERED NR 2 AND RETURNED TO IPL. INSPECTED NR 2 ENG WIRING SDR SWIA200211234Line · leakingLOST OIL PRESSURE AFTER TAKEOFF ON UPWIND LEG. REDUCED POWER. LANDED ON RWY 10, SHUT DOWN ENGINE AFTER LANDING. FOUND LOWER OIL COOLER HOSE ON LEFT ENGINE TO HAVE A HOLE. REMOVED AND REPLACED LEFT ENGINE OIL COOLER HOSE IAW MM 79-21-05. DOWNLOAD AND REVIESDR SWIA200211228Window Post · crackedPILOTS SIDE WINDOW POST CRACKED AT BOTTOM FORWARD CORNER, OVER 1 INCH LONG CRACK EXTENDS THROUGH RIVET. DISCOVERED ON PREFLIGHT INSPECTION. COMPLIED WITH SB 120-53-0072 RII CARD 53, INSTALLATION OF DOUBLER TO POST SKIN.SDR SWIA200211230Frame · crackedRIGHT NACELLE FRAME NR 1 CRACKED AT INBOARD AND OUTBOARD WEB AREAS. DISCOVERED DURING C-CHECK. REPLACED RIGHT NACELLE FRAME NR 1 IAW SB 120-54-0036 RII CARD 54-301.SDR SWIA200211233Hmu · malfunctionedON TAKEOFF ROLL, LEFT ENGINE TQ FLUCTUATED BETWEEN 90, 100 & 80 PERCENT WHILE THE RIGHT ENGINE TQ WAS AT 90 PERCENT. A ( + -) 10 PERCENT TQ DIFFERENCE ON LEFT ENGINE WAS OBSERVED. TAKEOFF ABORTED. RAN LEFT & RIGHT ENGINES IN TAKEOFF POSITION WHILE EEC ARE OSDR SWIA200211211Engine · leakingRIGHT ENGINE SMOKES ON SHUTDOWN. FOUND ENGINE BLOWING OIL OUT FROM FRONT COMPRESSOR. REMOVED AND REPLACED RT ENGINE AS REQUIRED IAW 71-00-00. OPS CHECK GOOD. PACKS NO LONGER SMOKING.SDR SWIA200211229Computer · malfunctionedCAPT'S EHIS FAILED AFTER TAKEOFF. RETURNED TO FIELD. REMOVED AND REPLACED THE NR 1 HPU WITH A SERVICEABLE UNIT. OPS CHECK GOOD.SDR SWIA200211199Connector · dirtyLEFT EEC MANUAL REVERSION FAILED ON TAKEOFF. ABORTED TAKEOFF. CLEANED CONTAMINATION FROM LEFT ENG EEC P1 CONNECTOR. RAN ENG, OPS CHECK GOOD.SDR SWIA200211152Control Unit · malfunctionedON APPROACH THE NACELLE FLAPS ARE INOP. REPAIRED WIRE W628-0007-22 BETWEEN P1869 & P0828. REMOVED AND REPLACED FLAP CONTROL UNIT. OPS CHECKS GOOD.SDR SWIA200211153Fuel Control · out of rigRIGHT ENGINE EEC FAILED DURING TAKEOFF ROLL AT APPROX 100 KTS. ABORTED TAKEOFF. ADJUSTED RIGGING ON LEFT AND RIGHT ENGINES AND RETRIMMED DURING ENGINE RUNS. OPS CHECKS GOOD.SDR AUS20020938Impeller · fod(AUS) RH ENGINE LOW PRESSURE IMPELLER DAMAGED BEYOND LIMITS BY FOD.SDR SWIA200211126Actuator · failedNACELLE FLAPS WOULD NOT GO PAST 4 ROWS OF LIGHTS WHEN 25 DEGREES OF FLAPS SELECTED. FLAP DISAGREEMENT WARNING. REMOVED AND REPLACED RIGHT NACELLE FLAP ACTUATOR IAW EMB120 MM 27-50-09. LEAK CHECK GOOD. OPS CHECK GOOD AT THIS TIME.SDR SWIA200211127Structure · crackedRIGHT NACELLE FLAP FOUND CRACKED. REMOVED AND REPLACED RIGHT NACELLE FLAP IAW MM 27-50-03. OPS CHECK GOOD.SDR SWIA200211121Hmu · malfunctionedON TAKEOFF ROLL, RIGHT ENGINE TORQUE WAS OBSERVED TO FLUCTUATE FROM 95 PERCENT DOWN TO 85 PERCENT AND BACK A NUMBER OF TIMES. TAKEOFF WAS ABORTED. REPLACED RIGHT ENGINE HMU WITH A SERVICEABLE UNIT. NO LEAKS NOTED AT THIS TIME. OPS CHECK GOOD.SDR SWIA200211227Frame · crackedRIGHT INBOARD LEADING EDGE INBOARD FRAME CRACKED, MARKED. DISCOVERED DURING C-CHECK. REPLACED RIGHT INBOARD LEADING EDGE FRAME.SDR SWIA200211067Engine · malfunctionedRIGHT ENGINE AUTO FEATHERED ON THE TAKEOFF ROLL. ABORTED THE TAKEOFF. PERFORMED TWO TAKEOFF POWER RUNS, ALL CHECKS NORMAL.
Back to Pratt & Whitney Canada PW118A