Pratt & Whitney Canada PW120
Service difficulty reports · 667
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW120' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW120' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR COEA2009042201911Selector Switch · brokenDURING CLIMB, POWER MANAGEMENT SWITCH FAILED. CREW UNABLE TO SELECT DESIRED MODE. CREW ELECTED TO BYPASS SIT AND LAND WHERE MX WAS AVAILABLE. MX REMOVED SELECTOR SWITCH AND REPLACED LOCKING TAB. SELECTOR SWITCH WAS REINSTALLED. ACFT RETURNED TO SERVICE.SDR CA090423011Diaphragm · cracked(CAN) DURING WALKAROUND, PREFLIGHT, MX NOTED A DEFORMATION IN FUSELAGE JUST AFT OF THE CREW/PAX DOOR. DEFORMATION WAS FOUND TO BE CAUSED BY LOAD FROM DOOR COUNTERBALANCE SPRINGS BEING TRANSFERRED TO FUSELAGE AFTER DIAPHRAM FAILED.SDR CA090416005Warning Light · illuminated(CAN) DEPARTING, THE CREW OBSERVED A DUAL LT MAIN GEAR UNLOCK INDICATION AFTER GEAR WAS SELECTED UP. THE ACFT RETURNED AND LANDED AT POINT OF DEPARTURE WITHOUT FURTHER PROBLEM. MX FOUND THE LANDING GEAR CONTAMINATED WITH SIGNIFICANT SLUSH/ICE. THE ACFT WAS THASDR CA090507005Wire Harness · open(CAN) RT ENGINE ITT HOTTER THAN LT ENGINE BY 50 TO 60 DEGREES CELCIUS IN ALL PHASES OF FLIGHT APPROX 755 ON TAKEOFF. RT ENGINE PERFORMANCE INDICATING SYS INPS/CHECK 72-01-60 COMPLETED. NEW T6 THERMO TRIM HARNESS INSTALLED IAW 77-20-00. GROUND RUN. TESTED SERVSDR CA090326003Stick Shaker · false activation(CAN) DEPARTING, THE CREW OBSERVED A STICK SHAKER/PUSHER FAULT. THE FAULT WAS CLEARED AND THE ACFT CONTINUED TO DESTINATION. THE FAULT REOCCURRED PRIOR TO LANDING AND THE ACFT DIVERTED. MX TROUBLESHOOTING WAS UNABLE TO DUPLICATE THE FAULT. THE ACFT HAS RETURNSDR CA090313005Landing Gear · malfunctioned(CAN) AT TAKEOFF DEPARTURE, THE CREW OBSERVED "FAIL TO RETRACT" INDICATION ON THE RT MAIN GEAR. THE ACFT RETURNED TO POINT OF DEPARTURE AND LANDED WITHOUT FURTHER PROBLEM. MX INSPECTED THE UPLOCK BOX AND ASSOCIATED CONNECTOR WITH NO FINDINGS. SEVERAL GEAR SWISDR CA090227004Cooler · cracked(CAN) COMMENCING THE DESCENT, THE CREW OBSERVED OIL PRESSURE FLUCTUATION ON THE NR 1 ENGINE ACCOMPANIED BY 2 FLASHES OF THE RED LOCAL ALERT. NO CCAS ALERT WAS OBSERVED. THE ACFT RETURNED TO POINT OF DEPARTURE AND LANDED WITHOUT FURTHER PROBLEM. MX OBSERVED ASDR CA090217001Gcu · malfunctioned(CAN) WHILE ENROUTE, THE CREW OBSERVED A NR 2 DC GENERATOR FAULT WHICH PERSISTED AFTER RESET ATTEMPT. THE ACFT RETURNED TO POINT OF DEPARTURE AND LANDED WITHOUT FURTHER PROBLEM. MX REPLACED THE NR 2 GCU AND THE ACFT WAS RETURNED TO SERVICE.SDR CA090205003Torque Tube · delaminatedFLAP POWER LIGHT INTERMITTENT. TORQUE TUBE P/N 234187B OF PRIMARY FLAP DRIVE SYSTEM FOUND TO HAVE 300 DEGREES OF ROTATION FREE PLAY. BONDED ENDS (RUBBER) FOUND DISINTEGRATED. TORQUE TUBE REPLACED AND LUBRICATED IAW AMM 27-52-00. ADDITIONAL CHECKS OF INSTALSDR CA090127006Pump · failedWHEN SPU`S WERE SELECTED OFF, HYDRAULIC PRESSURE WAS LOST ON THE NR 2 HYDRAULIC SYSTEM. ASSOCIATED "RUDDER PRESSURE", "NR 2 RUDDER HYDRAULIC" AND "RUDDER FULL PRESSURE" ILLUMINATED. RECTIFICATION, NR 2 HYDRAULIC ENGINE DRIVEN PUMP REPLACED, GROUND RUNS AND LSDR CA090126004Link · brokenWHILE CARRYING OUT LANDING GEAR RETRACTIONS, IT WAS FOUND THAT THE NOSE LANDING (NLG) WAS HUNG UP AT THE EXTENSION CYCLE. FURTHER INVESTIGATION REVEALED THAT THE NOSE LANDING (NLG) WAS NOT CENTERED AND THIS WAS PROBABLY CAUSED BY THE CENTERING SPRING NOT OVERSDR CA090122011Fitting · overtorquedON TWO SEPARATE OCCASIONS WHILE PERFORMING UNSCHEDULED MAINTENANCE INVOLVING THE MLG SELECTOR VALVE , TWO ALUMINUM HYDRAULIC FITTINGS HAVE BEEN FOUND DAMAGED OR CRACKED (1) OCT 27, 2008 - WHILE TROUBLESHOOTING A REPORTED HYDRAULIC LEAK UNION P/N MS21902D6 HADSDR CA090209002Tab · warpedWE HAVE BEEN EXPERIENCING A VIBRATION DURING DESCENT. AFTER SUBSTANTIAL INSPECTIONS, TESTING AND CONSULTATION WITH ATR, A CHECK WAS CARRIED OUT TO MEASURE THE SPRING TAB FOR WARPAGE. THE RESULTS WERE SENT TO ATR FOR ANALYSIS. THE WARPAGE LIMITS WERE DEEMED SDR CA090119005Brake · leakingLEFT INBOARD BRAKE PACK LEAKING HYDRAULIC FLUID FROM ONE PISTON PUCK.SDR CA081204003Sensor · unserviceable(CAN) FDR CORRELATION CHECK REVEALED LT AILERON ROLL SENSOR UNSERVICEABLE. SENSOR INSPECTED. OPERATING CABLE FRAYED AND BINDING. SENSOR REPLACED.SDR CA081204005Blade · cracked(CAN) LEADING EDGE NICKEL SHEATH VISUALLY INSPECTED AND A CRACK NOTED. IF PRESSURE APPLIED TO BLADED CRACK BECAME MORE NOTICEABLE. BLADE REMOVED FROM SERVICE.SDR CA081210009Engine · odor(CAN) DURING CRUISE, THE PILOTS NOTICED OIL ODOR AND MIST IN THE CABIN. THEY TURNED THE AIR BLEED FROM THE ENGINE OFF AND THE MIST AND ODOR DISAPPEARED. SOON AFTER, OIL PRESSURE FLUCTUATIONS AND THEN A DROP IN PRESSURE OCCURRED. THE PILOTS SHUT DOWN THE ENGSDR HNA2008F00057Doubler · crackedUPON GEAR EXTENSION DURING FINAL APPROACH TO RUNWAY 35, THE NOSE GEAR RED UNSAFE LIGHT INDICATION ILLUMINATED. BOTH MAIN GEARS LOCKED AND ILLUMINATED GREEN INDICATIONS. THE CREW DISCONTINUED THE APPROACH AND PERFORMED THE ALTERNATE GEAR EXTENSION PROCEDURE. SDR CA081027006Butterfly Valve · sticking(CAN) FOLLOWING DEPARTURE, THE ACFT FAILED TO PRESSURIZE IN AUTO OR MANUAL MODE. THE ACFT RETURNED TO POINT OF DEPARTURE AND LANDED WITHOUT FURTHER PROBLEM. THE GROUND AIR CONNECTION CHECK VALVE WAS FOUND TO BE STUCK IN THE OPEN POSITION. MAINT CLEANED AND LSDR CA081022004Generator · failed(CAN) DURING CRUISE THE NR 1 A/C WILD GENERATOR WENT OFF LINE. MX INSPECTED AND FOUND NR 1 AC WILD GENERATOR HAD FAILED INTERNALLY WITH SMALL SCREWS, WASHERS, ETC LAYING ON OUTLET COOLING SCREEN. TSO UNKNOWN.SDR KPV2008F00001Smoke Detector · malfunctionedON APPROACH, "SMOKE" WARNING LIGHT CAME ON, REMAINED ON FOR 3 SECONDS THEN WENT OUT. AFTER LANDING LIGHT CAME ON AGAIN THEN WENT OUT AFTER A FEW SECONDS. VISUALLY INSPECTED NR 1 AND NR 2 SMOKE DETECTORS, NO DEFECTS NOTED. PERFORMED OPS CHECK OF SMOKE DETECTIONSDR COE2008F00001Indicator · failedABORTED TAKEOFF, FLT NR 8202: DURING TAKEOFF ROLL THE CREW NOTICED THAT ANALOG PORTION ON THE NR 2 ENGINE TORQUE GAGE WAS INOPERATIVE. TAKEOFF WAS ABORTED AND THE AC WAS SAFELY TAXIED BACK TO THE BLOCKS. REMOVED AND REPLACED THE TORQUE GAUGE. (K)SDR HNA2008F00004Power Supply · brokenRT FWD EMERGENCY LIGHT IS DIM. REMOVED AND REPLACED BATTERY, FOUND CAMLOCK ON BATTERY BROKEN CAUSING LOOSE CONNECTION. OPS CHECK GOOD. (K)SDR HNA2008F00005Power Supply · brokenRT FWD EMERGENCY LIGHT IS DIM. REMOVED AND REPLACED BATTERY, FOUND CAMLOCK ON BATTERY BROKEN , CAUSING LOOSE CONNECTION. OP CHECK GOOD. (K)SDR CA080716007Fairing · damaged(CAN) FIRST AIR HAS OBSERVED SEVERAL OCCURRENCES OF DEGRADATION IN THE SURFACE PROTECTION COATING ON THE ACFT LOWER CENTER SECTION FAIRING PANELS. THE MATERIAL IS APPLIED IN ACCORDANCE WITH ATR SERVICE BULLETIN ATR42-53-0102. INVESTIGATION HAS FOUND THAT THE DSDR HNA2008F00001Transceiver · failedRADAR SPIKES, RADAR FAILED ENROUTE, THUNDERSTORM ACTIVITY WAS AHEAD OF THE FLIGHT. DISPATCHER AND CAPTAIN CHOSE TO HAVE FLIGHT RETURN. REMOVED AND REPLACED RADAR TR. OPS CHECK GOOD IAW SB 34-18. (K)SDR HNA2008F00002Radar · failedRADAR SPIKES RADAR FAILED ENROUTE TO FLO. THUNDERSTORM ACTIVITY WAS AHEAD OF THE FLIGHT. DISPATCHER AND CAPTAIN CHOSE TO HAVE FLIGHT RETURN. REMOVED AND REPLACED RADAR RT. OPS CHECK GOOD IAW SB 34-18. (K)SDR COEA0803914Wire Harness · shortedRETURN TO BLOCKS, FLIGHT 7826 GPI TO GTF: AFTER TAXIING TO THE RUNWAY AND COMPLETION OF THE TAXI CHECKLIST ITEMS. THE CREW NOTICED A RAPID INCREASE IN TAT TEMP (TURBINE AIR TEMP) AND THE AFCS (AUTOMATIC FLIGHT CONTROL SYSTEM) SHOWED "DADC (DIGITAL AIR DATA CSDR COEA0801917Cooling Fan · failedODOR IN CREW COMPARTMENT, AFTER LANDING, WHILE TAXIING TO PARKING RAMP. THE CREW NOTICED A LIGHT BURNING SMELL IN COCKPIT, FOLLOWED BY NR1 PACK VALVE FAULT. SHORTLY AFTER ARRIVAL, PERFORMED A TEST ENGINE RUN WITH MECHANIC ON BOARD, TO DUPLICATE. WITH THE NRSDR COEA0802908Wire · shortedRETURN TO BLOCKS. AS THE ACFT WAS TAXIING INTO THE DEICE AREA THE PILOT NOTICED A FLASH OF LIGHT FOLLOWED BY SPARKS FALLING NEAR THE COPILOTS FEET. ELECTRICAL POWER AND THE MAINT INDICATOR ON THE MAINT PANEL WAS POPPED. WIRE HARNESS WIRES SHORTED TO EACH OTSDR COEA0801914Seat Track · damagedFOUND DURING HEAVY CHECK. MAJOR REPAIR. FOUND TOOL DAMAGE (MISDRILLED HOLE) (2) PLACES ON UPPER FLANGE OF LT OB SEAT TRACK AT FLOOR CROSSBEAMS 20 AND 21. REMOVED AND REPLACED DAMAGED SECTION OF SEAT TRACK FROM END AT FRAME 23 TO PREVIOUSLY INSTALLED SPLICE SDR COEA0802914Floorbeam · crackedFOUND DURING HEAVY CHECK. MAJOR REPAIR. EO 5315-01: THE RT OB LONGITUDINAL FLOOR BEAM IS CRACKED IN (4) PLACES. AT FRAME 21 AND 24 ALSO FWD AND AFT OF FRAME 30. THE LT OB LONGITUDINAL FLOORBEAM IS CRACKED IN (2) PLACES. AT FRAME 28 AND FRAME 34. REMOVED SDR CA080402005Tank · leakingDURING DESCENT, OIL MIST WAS NOTED IN THE CABIN FOLLOWED BY A LOW OIL PRESSURE WARNING INDICATION. THE ENGINE WAS SHUT DOWN BY THE CREW. TROUBLESHOOTING REVEALED LOW OIL LEVEL IN THE TANK, AND SIGNS OF EXTERNAL OIL LEAKAGE. THE ENGINE IS TO BE REMOVED FOR ISDR COEA0801912Wire Harness · wornOVER FLY. FLT NR 7202, ENROUTE, THE NAVIGATION LIGHT CIRCUIT BREAKERS ALL POPPED. THE CREW ATTEMPTED TO RESET THE CIRCUIT BREAKERS BUT THEY WOULD NOT STAY IN. A DECISION WAS MADE TO OVER FLY AND CONTINUE TO OTHER DESTINATION FOR MAINTENANCE. NO EMERGENCY WASDR COEA0801908Release Cable · lack of lubeAIR TURNBACK, FLT NR 7304. UPON ROTATION, THE CARGO DOOR UNLOCK LIGHT ILLUMINATED. CREW ELECTED TO RETURNED. AIR CRAFT MADE A SAFE AND NORMAL LANDING. DOOR LOCK RELEASE CABLE WAS LUBRICATED AND AC RETURNED TO SERVICE. AS A PRECAUTION FWD CARGO DOOR LOCK RSDR CA080222003Wire Harness · chafed(CAN) DURING TROUBLESHOOTING OF A FUEL BOOST PUMP SNAG, MAINT DISCOVERED THE RELATED WIRING HARNESS HAD BEEN DAMAGED DUE TO CHAFING ON THE EDGE OF THE FIXED CARGO LINER PANEL AT THE AFT SIDE OF THE 91VU SHELF. THE CARGO LINER PANEL IS PART OF THE FIRST AIR CLASDR CA080213008Pump · malfunctioned(CAN) SHORTLY AFTER DEPARTURE, THE CREW OBSERVED A LOW PRESSURE INDICATION ON THE BLUE HYDR SYS. THE AC RETURNED TO POINT OF DEPARTURE AND LANDED WITHOUT FURTHER PROBLEM. MAINT REPLACED THE BLUE SYS PUMP AND THE AC WAS RETURNED TO SERVICE. (TC NR 20080213008)SDR CA080207011Prop Brake · seized(CAN) AFTER ARRIVAL AT DESTINATION, THE AC TAXIED TO THE TERMINAL. PRIOR TO PASSENGER DEPLANING, THE CREW OBSERVED A MASTER WARNING (PROP UNLOCK). THE F/O REPORTED THAT THE NR 2 ENG WAS ON FIRE AND THE NR 2 CONDITION LEVER WAS SELECTED TO SHUTOFF POSITION. THESDR CA080214007Hydraulic Line · cracked(CAN) WHILE ENROUTE THE "IB ROLL SPL HYD" AND NR 1 "HYD ISO VLV" CAUTION LIGHTS ILLUMINATED. CHECKED THE HYD QUANTITY AND NOTICED NR 1 QUANTITY AT 1.0 AND DECREASING. COMPLETED THE QRH CHECKLIST AND THEN BRIEFED THE F/A AND PASSENGERS. MADE A VISUAL APPROACH ASDR COEA0801911Wire Harness · wornAIR TURN BACK. FLT NR 8804. AFTER TAKE OFF THE LANDING GEAR WOULD NOT RETRACT. CREW ATTEMPTED SEVERAL CYCLES BEFORE ELECTING TO RETURN. GEAR LIGHTS RED AND GREEN, WOULD CYCLE BETWEEN GEAR DOWN AND LOCKED AND UNLOCKED. NO EMERGENCY WAS DECLARED AND THE PLANSDR CA071228001Ecu · failed(CAN) POWER LEVER SPLIT AT HIGH POWER SETTINGS. FAULT ISOLATED TO FAULTY LT ENGINE ECU. ECU REPLACED. TESTED SERVICEABLE. (TC NR 20071228001)SDR COEA0712911Ahrs · failedFLT NR 8202 JUN TO SIT, FLT NR 7203 SEA TO KTN AIR TURN BACKS: NR 2 AHRS (ALTITUDE AND HEADING REF SYSTEM) WITH EFIS COMP ( ELECTRONIC FLIGHT INSTRUMENTS SYS FAULTED). FLT NR 8203 AHRS CONNECTIONS CLEANED AND RESECURED, SYSTEM OPERATED NORMALLY FOR 3 STOPS. SDR COEA0704912Switch · failedAIR TURNBACK. FLIGHT NR 7202. DURING CLIMB 12 MILES OUT, THE NR 2 BLEED VALVE WOULD NOT OPEN AND FAULTED. RESET UNSUCCESSFUL CREW ELECTED TO RETURN TO DEPARTURE. AC LANDED NORMALLY. REPLACED NR 2 ENGINE BLEED PUSH BUTTON SWITCH. (K)SDR HNAA0700271Oil System · low pressureON CLIMBOUT NR 1 ENG OIL PRESSURE GAUGE FLUX, FOLLOWED BY NR 1 ENGINE OIL WARNING LIGHT. CREW REDUCED POWER AND LEVELED OFF, OIL PRESSURE STABILIZED AND NR 1 ENG OIL WARNING LIGHT EXTINGUISHED. NR 1 OIL PRESSURE FLUX BETWEEN 60 AND 30 PSI FOR APPROX 5 MIN.SDR CA071128003Hmu · malfunctioned(CAN) OPERATOR REPORTED UNCOMMANDED ENGINE SHUTDOWN AND EEC REVERSION DURING CLIMB. EEC WAS LATER REPLACED ON GROUND AND OPERATION WAS NORMAL. HMU WAS ALSO REPLACED AS A PRECAUTION. BOTH UNITS WILL BE RETURNED TO MFG FOR INVESTIGATION AND FOLLOW UP. (TC NR 200SDR HNA2008F00027Switch · failedTHE FLOOR LEVEL EMERGENCY LIGHT FLICKERED IN FLIGHT. TRIED TO RESET FROM FLIGHT DECK. REMOVED AND REPLACED BOTH F/A AND COCKPIT EMERGENCY LIGHT SWITCHES.. GROUND RAN AC, OPS CHECKED GOOD. (K)SDR HNAA0700258Pump · cloggedTHE NUMBER ONE ENGINE MANUAL CAUTION LIGHT ILLUMINATED AT ROTATION, SHORTLY THERE AFTER (1500FT) TORQUE DROPPED OFF. THEN THE PROP WENT INTO FEATHER. THE MAX TORQUE REACH AT 107 PERCENT. THE CREW MANUALLY SHUT DOWN THE ENGINE. DECLARED AN EMERGENCY AND DIDSDR COEA0702913Acm · smokeFLT 7693, DURING TAXI TO RUNWAY CREW NOTED SMOKE IN COCKPIT. ELECTRIC SMOKE CAP LIGHT ILLUMINATED AND NR 1 PACK VALVE FAULTED ON CAP. CREW RETURNED AIRCRAFT TO RAMP. REPLACED NR 1 AIR COOLING TURBINE. (M)SDR COEA0710911Control Unit · shortedWHILE ENROUTE, NR 1 ACW GENERATOR FAULT WOULD NOT RESET. SMELLED ELECTRICAL SMOKE FOR 30 SECONDS THEN WENT AWAY. REMOVED AND REPLACED NR 1 ACW GENERATOR AND ACW GENERATOR CONTROL UNIT. (M)SDR CA071024009Tie Bolt · broken(CAN) MAINTENANCE CREWS NOTED A BROKEN MAIN WHEEL TIE BOLT. THE MAIN WHEEL ASSEMBLY AND BRAKE ASSEMBLY WERE REPLACED. (TC NR 20071024009)
Back to Pratt & Whitney Canada PW120