duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE engine_model_key = 'PW120A'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR V0XR201010220003Skin · corroded(V0XR) FRAME & SKIN AT STN 545, STR 31R TO 30R IS CORRODED BEYOND LIMITS. REMOVED LIGHT CORROSION. W/C 1086Oct 22, 2010 · N822EA · Dhav DHC8103 · Fuselage Main, Plate/SkinSDR V0XR201010220004Skin · corroded(V0XR) TCAS ANTENNA DOUBLER BETWEEN STN 488 TO 510 AT STR 33R IS CORRODED BEYOND LIMITS. FABRICATED NEW SHEET METAL.Oct 22, 2010 · N822EA · Dhav DHC8103 · Fuselage Main, Plate/SkinSDR HNAA2010101900230Control Unit · malfunctionedNR 2 PROP RPM AND TORQUE SURGED ON CLIMB OUT. STAYED WITHIN LIMITES, REDUCED POWER AND PROP RPM DROPPED INTO PROHIBITED ZONE-PROP SYNC OFF. R & R NP INDICATOR AND PROP CONTROL UNIT. ALSO R & R NR 2 TSCU RAN ENG OPS CHECKED GOOD.Oct 19, 2010 · N812EX · Dhav DHC8102 · Propeller AssemblySDR HNAA2010101400227Lamp · inoperativeROW 1AC, 3RD RED FLOOR EMERGENCY PATH LIGHT INOP. RELAMP 3RD RED FLOOR EMERGENCY PATH LIGHT AT ROW 1 IAW AMM 33-20-00.Oct 14, 2010 · N914HA · Dhav DHC8102 · Emergency LightingSDR HNAA2010101200219Engine · power lossNR 2 ENGINE UNABLE TO MAKE CHARTED TORQUE. ONLY ABLE TO GET 80 PERCENT TORQUE WITH ITT AT 785 AT 6000' AND OAT AT +10C.FOUND ENGINE WITH INTERNAL DAMAGE, R & R ENGINE.Oct 11, 2010 · N838EX · Dhav DHC8102 · Engine (Turbine/Turboprop)SDR HNAA2010100700228Filler · missingROW 7 EMERGENCY FLOOR PATH LIGHT IS OBSCURED BY THE WIRES THAT SHOULD BE COVERED WITH BLACK PLASTIC FILLER. INSTALL BLACK PLASTIC FILLER PIECE WHERE IT WAS MISSING. LIGHT MODULE IS VISIBLE AT SAID LOCATION. REF A, 33-51-11.Oct 7, 2010 · N804EX · Dhav DHC8102 · Emergency LightingSDR HNAA2010100500226Solenoid Valve · inoperativeROLL SPOILER OTBD CAUTION LIGHT ILLUMINATED. ABORTED TAKEOFF AND RETURNED TO GATE. VERFIED SPOILERS INACTIVE, (SHUTOFF) REMOVED CONNECTOR FROM UNLOADING VALVE AND SPOILERS STILL SHUT OFF AND NO VOLTAGE TO SOLENOID WHEN SELECTED ON. SUSPECTED BAD UNLOADING VALOct 5, 2010 · N975HA · Dhav DHC8102 · Drag Control SystemSDR HNAA2010100300225Bulb · inoperativeEMERGENCY FLOOR LIGHT INOP. R & R FLOOR LIGHT BULB. OPS CHECKED GOOD.Oct 3, 2010 · N931HA · Dhav DHC8102 · Emergency LightingSDR HNAA2010093000224Door · malfunctionedON GO AROUND, RETRACTED GEAR, LANDING GEAR INOP, CAUTION LIGHT ILLUMINATED AND LT MAIN GEAR DOOR REMAINED OPEN AND VISUALLY VERIFIED. AFTER A COUPLE MINUTES, CAUTION LIGHT WENT OUT. USED ALTERNATE EXTENSION PRECEDURES IAW CHECK LIST SWUNG GEAR MULTIPLE TIMES OSep 30, 2010 · N837EX · Dhav DHC8102 · Landing Gear Door Retract SectionSDR CA101004007Acm · seizedDURING CLIMB, THE CABIN TEMPERATURE BECAME UNCONTROLLABLE IN AUTO AND MANUAL. UPON REACHING FL 230 THE CABIN PRESSURE WARNING LIGHT CAME ON INDICATING A 10,000 FOOT CABIN. A RAPID DESCENT DOWN TO 8,000 FT WAS INITIATED. THE CABIN BECAME VERY HOT SO THE CREW DSep 30, 2010 · Dhav DHC8102 · Cabin Cooling SystemSDR CA100927001Bushing · brokenWHILE REPLACING LOWER PACKER SHIMS (REF SB8-54-19), THE BUSHING WAS FOUND BROKEN IN 2 PARTS. NR1 ENGINE LOWERED AND THE LOWER, INBD NACELLE STRUT REMOVED. THE REMAINING PART OF THE BROKEN BUSHING REMOVED FROM THE LONGERON/WEB WITH A PULLER. NEW PART INSTALLESep 22, 2010 · Dhav DHC8102 · Nacelle/Pylon, Main FrameSDR CA100923001Antenna · brokenTHE ACFT ARRIVED MISSING ITS NR2 VHF COM ANTENNA. IT IS SUSPECTED THAT THE ANTENNA WAS BROKEN OFF BY A BIRD STRIKE ON THE PREVIOUS DEPARTURE. THE ANTENNA WAS REPLACED AND THE ACFT RETURNED TO SERVICE. ANTENNA PN 10-105-31A-B-2K. A/C TSN 50279, CSN 55606. (TCSep 21, 2010 · Dhav DHC8102 · VHF Communications SystemSDR CA100927005Fairing · damagedBIRD STRIKE IN DESCENT AT 6000 FT, RT WING ROOT FAIRING DAMAGED. UPON LANDING, INSP REVEALED A 5 HOLE, IN WING, ROOT FAIRING ITSELF. FAIRING REMOVED AND CURRENTLY BEING REPAIRED IAW RD8-51-252 AND SRM 51-70-00. REF IPC 53-30-00, FIG 25, ITEM 170B.Sep 21, 2010 · Dhav DHC8102 · Aerodynamic FairingsSDR CA101027010Structure · damagedBIRD STRIKE IN DECENT AT 6000 FEET, RESULTING IN THE RT WING ROOT BEING DAMAGED. FAIRING REMOVED AND ANOTHER FAIRING INSTALLED. DAMAGED FAIRING SUBSEQUENTLY REPAIRED IAW THE SRM.Sep 21, 2010 · Dhav DHC8102 · Wing Main, Frame StructureSDR CA100910002Wire Harness · damagedAPPROX 3 MINS AFTER REACHING CRUISE ALTITUDE ON FLIGHT 8724, CREW NOTICED TORQUE AND NH FLUCTUATIONS ON NR1 ENG OF APPROX 10 PERCENT. THEY THEN STARTED TO PULL POWER BACK ON THAT ENGINE TO NO AVAIL. THEY EVENTUALLY HAD POWER BACK TO FLIGHT IDLE, YET ENG WAS Sep 9, 2010 · Dhav DHC8102 · Turbine Engine System WiringSDR HNAA2010090800210Connector · dirtyIN CRUISE, NR1 ENGINE OIL TEMP WENT TO 120 DEGREESC FOR APPROX 17 MINUTES. REDUCED POWER AND INITIATED DECENT. OIL TEMP RETURNED TO GREEN.( NOTE: F/O TIMED DURATION BETWEEN 115 AND 120). R & R NR1 TEMP GAUGE, NO FIX, RETURNED TO ORIGINAL. CLEANED NR1 TEMP BUSep 8, 2010 · N911HA · Dhav DHC8102 · Engine Oil System WiringSDR CA100921004Indicator · faultyTORQUE FLUCTUATION AFTER T/O, THE CREW NOTED INDICATED TORQUE FLUCTUATIONS AND OVERTEMP CONDITION. THE POWER WAS REDUCED, A PRECAUTIONARY SHUTDOWN PERFORMED AND THE ACFT RETURNED TO THE POINT OF DEPARTURE WHERE AN UNEVENTFUL SINGLE ENGINE LANDING WAS MADE. TSep 8, 2010 · Dhav DHC8102 · Engine BMEP/Torque IndicatingSDR HNAA2010090100218Oil System · lowNR2 ENGINE OIL PRESSURE DROPPED AND WARNING LIGHT ILLUMINATED WITH ADVANCING POWER LEVERS. SERVICED NR1 AND NR2 ENGINE OIL WITH 2.5 QTS EA IAW 12-20-79. GROUND RAN ACFT. NO DEFECTS NOTED AT THIS TIME.Sep 1, 2010 · N941HA · Dhav DHC8102 · Engine Oil Indicating SystemSDR HNAA2010090100220Fitting · corrodedCORROSION AT TENSION FITTING STA 531 AND STR 31 RT SIDE. REMOVED FWD TENSION FITTING AT CORROSION AREA. COMPLIED WITH BOND TEST, NO DEFECTS NOTED. REPLACED TENSION FITTING IAW DWG 85330510. REMOVED CORRODED SECTION OF STR 31, RT SIDE BETWEEN FRAME X488 X531.Sep 1, 2010 · N975HA · Dhav DHC8102 · Fuselage Main, Attach FittingsSDR CA100830001Control Head · failed(CAN) INBOUND TO YTS FLIGHT CREW REPORTED SMOKE IN THE COCKPIT AND DECLARED AN EMERGENCY FOR LANDING IN YTS. 60 NM FROM YTS, THE SMOKE SEEMED TO BE COMING FROM THE NR 2 TRANSPONDER. FLIGHT CREW PULLED THE CIRCUIT BREAKER FOR THE TRANSPONDER AND THE SMOKE DISAAug 27, 2010 · Dhav DHC8102 · ATC Transponder SystemSDR HNAA2010082600198Wire · brokenROW 13 EMERGENCY FLOOR PATH LIGHT INOP, WITH BROKEN WIRE. SPLICE WIRE AT ROW 13 RED EMERGENCY FLOOR LIGHT IAW AMM 20-45-07.Aug 26, 2010 · N912HA · Dhav DHC8102 · Light System WiringSDR CA100819005Blade · damaged(CAN) ON LANDING IN YSB, THERE WERE MULTIPLE BIRD STRIKES TO THE LT PROPELLER AND WING AREA. THE A/C WAS INSPECTED PER THE AMM 05-50-26. THERE WAS DAMAGE TO 3 OF THE 4 BLADES ON THE LH PROPELLER. THE LT PROPELLER WAS REPLACED BEFORE FURTHER FLIGHT. A/C TSN 500Aug 17, 2010 · Dhav DHC8102 · Propeller Blade SectionSDR CA100811005Line · leakingAFTER LANDING, THE FLIGHT CREW BEGAN TO EXPERIENCE BURNING EYES AND COUGHING WITH A CHOKING FEELING DESCRIBED AS SIMILAR TO PEPPER SPRAY. THERE WAS NO SMOKE OR BURNING SMELL AND THE CABIN WAS UNAFFECTED. MX DISCOVERED A PIN HOLE LEAK IN THE "GEAR DOWN" HYD Aug 9, 2010 · Dhav DHC8102 · Hydraulic System, MainSDR HNAA2010082600197Door · damagedLEFT AMBER DOOR LIGHT REMAINED ON AFTER GEAR RETRACTION. COMPLIED WITH ABNORMAL CHECK LIST PROCEDURES, LIGHT REMAINED ON WITH DOOR APPEARING TO REMAINED CLOSED. REPLACED LT FWD MAIN GEAR DOOR IAW MM 32-10-21. ADJUSTED, RIGGED DOOR ACTUATOR, PROXIMITY SWITCHAug 1, 2010 · N937HA · Dhav DHC8102 · Landing Gear DoorsSDR HNAA2010082600195Glide Slope · malfunctionedCREW REPORTED BOTH GLIDE SLOPES OPERATED NORMALLY AND LOCALIZERS SHOW ACFT LT OF RUNWAY. HAD TO USE WET COMPASS FOR HEADING DIRECTION. PERFORMED OPS CHECK OF BOTH ILS SYS WITH TEST EQUIPMENT, OPS NORMAL AT THIS TIME.Jul 29, 2010 · N808EX · Dhav DHC8102 · Glide Slope SystemSDR HNAA2010082600196Fire Loop · malfunctionedAPU FAULT LIGHT ILLUMINATED FOLLOWED BY MASTER WARNING AND CHECK FIRE DETECTION LIGHT. R & R APU FIRE LOOP. OPS CHECK GOOD AT THIS TIME.Jul 25, 2010 · N936HA · Dhav DHC8102 · Fire DetectionSDR HNAA2010072100181O-Ring · leakingIN FLIGHT CRUISE POWER AT 83 PERCENT TORQUE, NR 1 OIL PRESSURE FLUCTUATED IN TO YELLOW AT 50 PSI. NR 1 POWER LEVER MOVED TO FLIGHT IDLE, THEN OIL PRESSURE WENT INTO RED WITH WARNING LIGHT, THEN NR 1 ENGINE SHUTDOWN IAW CHECK LIST. FOUND OIL LEAKING FROM PCU Jul 17, 2010 · N940HA · Dhav DHC8102 · Turbine Engine Oil SystemSDR CA100713009Mount · wornSHOCK MOUNTS FOR CVR COMPLETELY WORN AWAY. COMPLETE METAL TO METAL CONTACT IS OCCURRING, POSSIBLY DAMAGING THE CVR OVER TIME. SHOCK MOUNTS REPLACED.Jun 30, 2010 · Dhav DHC8102 · Fuselage Main, Attach FittingsSDR CA100701002Fitting · crackedDURING CLIMB, THE NR 1 HYD SYS FLUID QTY DEPLETED AND THE NR 1 ENG HYD PUMP CAUTION LIGHT ILLUMINATED SHORTLY AFTER. AS IT WAS A SHORT FLIGHT, CREW ELECTED TO CONTINUE, DECLARED AN EMERGENCY INBOUND AND LANDED WITHOUT FURTHER INCIDENT. A VISUAL INSP OF THE AJun 29, 2010 · Dhav DHC8102 · Hydraulic Pump (Electric/Engine), MainSDR CA100625003Flap Track · corrodedNR 4 LT FLAP TRACK BEAM ASSEMBLY FOUND WITH ADVANCED CORROSION IN HIDDEN AREA. THIS BEAM WOULD NORMALLY BE A REPEAT INSPECTION AND BLENDING OF WEAR POINTS. IT WAS DECIDED TO CHANGE OUT THIS BEAM TO HAVE IT OVERHAULED INSTEAD OF RE-WORKING ON WING. THE HIDDENJun 25, 2010 · Dhav DHC8102 · Trailing Edge FlapsSDR HNAA2010063000166Lamp · inoperative(2) EMERGENCY EXIT MARKER LIGHTS ON LOWER AIR STAIR DOOR MARKER ARE NOT WORKING. RELAMPED EMERGENCY LIGHT AT SAID LOCATION BY REMOVING LENS, R & R BULBS AND RE-INSTALLED LENS.Jun 24, 2010 · N839EX · Dhav DHC8102 · Emergency LightingSDR HNAA2010063000165Stud · looseRIGHT AILERON INBD BONDING STUD SPINS. REPAIRED BONDING STUD IAW EO8-57-10-0263.Jun 21, 2010 · N941HA · Dhav DHC8102 · AileronsSDR CA100621010Battery · thermal runawayDURING CLIMB THE MAIN BATTERY HOT WARNING LIGHT CAME ON. THE BATTERY WAS TURNED OFF PER THE QRH BUT THE TEMPERATURE DID NOT DECREASE. AN EMERGENCY WAS DECLARED AND THE ACFT RETURNED DEPARTURE. THE BATTERY WAS REPLACED.Jun 19, 2010 · Dhav DHC8102 · Battery/Charger SystemSDR CA100617004Bearing · corrodedCONTROLS FOR ELEV AND AILERON STIFFER THAN REST OF FLEET, SAME FROM EITHER CONTROL COLUMN. AILERON STIFF, MOVED TO DEFECT 920351 TO SPLIT SNAGS RECTIFICATION, PULLED PITCH AND ROLL DISCONNECT. FOUND PILOTS CONTROL COLUMN TO BE STIFF IN BOTH PITCH AND ROLL. Jun 15, 2010 · Dhav DHC8102 · Elevator StructureSDR CA100617007Pulley · seized(CAN) AILERON CONTROL REPORTED AS STIFF. RECTIFICATION, WITH ROLL CONTROL DISCONNECTED FOUND THE PILOTS SIDE TO BE STIFF. FOUND CAPT CONTROL COLUMN HAND WHEEL BEARING TO BE ROUGH. HAND WHEEL REMOVED AS PER 27-32-17 AND BEARINGS (P/N- MS27641-10) REPLACED. Jun 15, 2010 · Dhav DHC8102 · Aileron Control SystemSDR CA100615001Battery · overtemp(CAN) TAIL 808 FLIGHT 7671 CREW RECEIVED A AUXILIARY BATTERY HOT INDICATION IN CRUISE. ACTIONING QRH AND DECISION WAS MADE TO DIVERT AIRCRAFT. AUXILIARY BATTERY TEMPERATURE CONTINUED TO CLIMB EVEN AFTER THE BATTERY WAS SELECTED OFF. EMERGENCY WAS DECLARED Jun 13, 2010 · Dhav DHC8102 · Battery/Charger SystemSDR CA100615004Actuator · crackedDURING ROUTINE MX, A HYD LEAK WAS NOTICED COMING FROM THE RT WING. INVESTIGATION REVEALED THAT THE RT INBD ROLL SPOILER ACTUATOR HSG HAD FRACTURED AND WAS LEAKING. THE RT INBD ROLL SPOILER ACTUATOR WAS REPLACED. ACFT TSN 53712, CSN 56685. PART INFO: PN REMOVJun 12, 2010 · Dhav DHC8102 · SpoilersSDR CA100614004Recorder · malfunctionedFDR WAS REMOVED FROM THE ACFT TO INVESTIGATE AN UNCOMMANDED TORQUE INCREASE, AND AT THAT TIME IT WAS DETERMINED THAT THE FDR HAD BEEN UNSERVICEABLE FOR 111 HRS WITHOUT TURNING ON THE FDR FAIL LIGHT. LIGHT WAS DETERMINED TO BE SEVICEABLE. THE MOST RECENT DATAJun 11, 2010 · Dhav DHC8102 · Data Recorders (Flight/Maintenance)SDR CA100614005Ballast · failedTHE ACFT WAS ENROUTE. A PASSENGER SEATED IN SEAT 6D REPORTED SMELLED SMOKE. THE F/A ALSO NOTICED THE SMOKE ODOR WHICH DISSIPATED QUICKLY. A SHORT WHILE LATER THE FLIGHT CREW ALSO SMELLED THE SMOKE SMELL BUT IT DISSIPATED WITHIN 2 MINUTES. THE FLIGHT LANDEDJun 11, 2010 · Dhav DHC8102 · Passenger Compartment LightingSDR CA100616004Fitting · crackedUPON CARRYING OUT FORWARD FUSELAGE INSPECTION (TASK 112-DH1) I FOUND A DAMAGED B-NUT ON THE OXYGEN LINE THAT RUNS FROM THE CREW OXYGEN FILL PORT TO THE CREW OXYGEN TANK. THE B-NUT WAS CRACKED IN THREE DIFFERENT SPOTS WHICH INDICATES POSSIBLE EVIDENCE OF EXCESJun 9, 2010 · Dhav DHC8102 · Crew Oxygen SystemSDR CA100609002Bumper · missingDURING A POST FLIGHT INSP, THE LT ELEVATOR SPRING TAB WAS FOUND DAMAGED AT THE INBD T/E. THERE WAS ALSO MINOR DAMAGE FOUND ON THE FWD AND TRAILING RUDDER. FURTHER INVESTIGATING REVEALED THAT BOTH LT AND RT TOP ELEVATOR BUMPER STOPS RUBBER WERE MISSING. THIS CJun 7, 2010 · Dhav DHC8102 · Elevator Miscellaneous StructureSDR HNAA2010063000158Oil Cooler · leakingIN FLIGHT, NR 1 ENGINE OIL PRESSURE DROPPED TO 40PSI FOR 3 MINUTES. SHUT NR1 ENGINE DOWN IAW CHECK LIST, LANDED NORMALLY WITH 1 ENGINE. INVESTIGATED, FOUND HELICOIL BACKING OUT ON INPUT SIDE OF THE OIL COOLER. FOUND O-RING ON OUTPUT SIDE SLICED. R & R OIL COOJun 6, 2010 · N906HA · Dhav DHC8102 · Turbine Engine Oil SystemSDR CA100528014Hydraulic Line · crackedDURING ACFT TAXI, THE NR2 HYD SYS LOST PRESSURE. AFTER SHUTDOWN, A HYD LEAK WAS DISCOVERED IN THE NLG WW. THE NLG DOOR CLOSE PRESSURE LINE WAS FOUND CRACKED. IPC 32-30-00, FIG 5, ITEM 340. THE LINE WAS REPLACED AND THE ACFT RETURNED TO SERVICE.May 20, 2010 · Dhav DHC8102 · Hydraulic System, MainSDR HNAA2010051000141Pump · failedAFTER LEVELING OFF AT 3000 FT, MASTER CAUTION LIGHT ILLUMINATED WITH ASSOCIATED RUDDER HYD CAUTION LIGHTS. PRESSURE DROPPED TO ZERO, NO CHANGE IN QTY. R & R NR 2 ENGINE DRIVEN PUMP AND NR 2 CASE DRAIN FILTER IAW 29-10-11 AND 29-10-26. GROUND RUN, OPS CHECKEDMay 10, 2010 · N814EX · Dhav DHC8102 · Hydraulic Pump (Electric/Engine), MainSDR HNAA2010050900140Bypass Switch · failedNR 2 FUEL FILTER BYPASS CAUTION LIGHT ILLUMINATED IN FLIGHT. OIL TEMPS DROPS TO TOP OF YELLOW ARC. R & R NR2 ENGINE FUEL FILTER BYPASS SWITCH IAW MM 72-01-40.May 9, 2010 · N911HA · Dhav DHC8102 · Engine Fuel DistributionSDR HNAA2010050600134Terminal · burnedIN FLIGHT, ELECTRICAL SMELL NOTED IN COCKPIT FOLLOWED BY SMOKE COMING FROM CAPTAINS WINDSHIELD WIRE TERMINAL AREA. INSPECTED CAPTAIN'S FRONT WINDSHIELD TERMINALS L1. FOUND TERMINAL END BURNED WITH MINOR DISCOLORATION ON TERMINAL BUSS L2. NO DEFECTS FOUND. May 6, 2010 · N942HA · Dhav DHC8102 · Ice/Rain Protection System WiringSDR HNAA2010050400133Check Valve · failedAFTER GEAR UP SELECTION, NR 2 HYD QTY DROPPED TO 1 QT. AFTER WHICH SPOILER AND NR 2 ISO LIGHTS ILLUMINATED. NO PRESSURE DROP AND QTY REMAINED AT 1QT. R & R CHECK VALVE ON STEERING MANIFOLD. OPS AND LEAKED CHECKED GOOD.May 4, 2010 · N938HA · Dhav DHC8102 · Landing Gear Steering SystemSDR HNAA2010050300132Ahrs · malfunctionedIN FLIGHT HOLDING AND IN TURBULENCE, NR 1 AHRS FAILED, BOTH CHANNELS OF YAW DAMPER AND FLIGHT DIRECTOR FAILED. SAHS CORRECTED AHRS. ACFT RETURNED TO FIELD DUE TO WEATHER. POWER DOWN AND POWER UP ACFT AND ALL SAID SYS WORKED NORMAL.May 3, 2010 · N941HA · Dhav DHC8102 · Attitude and Direction Data SystemSDR HNAA2010043000121Wire · wrong partLAST (2) FLOOR LEVEL EMERGENCY LIGHTS IN OP. FOUND 3352, CR5 TO BE THE WRONG PN AND MISWIRED. INSTALLED CORRECT DIODE AND WIRED IT CORRECTLY IAW 33-53-01.Apr 30, 2010 · N942HA · Dhav DHC8102 · Light System WiringSDR CA100610001Actuator · leakingFLT CREW REPORTED LOSS OF NR 1 HYD SYS PRESSURE AT TAKEOFF. ABORTED TAKEOFF AND RETURNED TO GATE WITHOUT FURTHER INCIDENT. MX FOUND THE RT INBD SPOILER ACTUATOR LEAKING DUE TO FAILURE OF THE HSG. SPOILER ACTUATOR REPLACED. OPS CHECKS AND LEAK CHECKS CARRIEApr 30, 2010 · Dhav DHC8101 · Drag Control Actuator
Back to Pratt & Whitney Canada PW120A