Pratt & Whitney Canada PW123

Service difficulty reports · 1,854

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE engine_model_key = 'PW123'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR CA121025009Terminal · shorted(CAN) DURING DESCENT THROUGH FL100 CREW HEARD A POPPING SOUND AND NOTICED AN ELECTRICAL ODOR. A SMALL FLAME WAS NOTICED AT THE CAPTAIN`S WINDSHIELD HEATER WIRES. FLAME EXTINGUISHED AS SOON AS WINDSHIELD HEAT WAS SELECTED OFF. CREW DONNED OXYGEN MASKS. AN EMOct 25, 2012 · Dhav DHC8311 · Window System WiringSDR CA130128020Lug · cracked(CAN) LT AND RT MLG UPPER MEMBER FORWARD LUG FOUND CRACKED DURING NDI CALLED FOR IN AD CF2011-35.Oct 22, 2012 · Cndair CL2156B11215 · Fuselage, Landing Gear Attach FittingsSDR CA121129001Bearing · corroded(CAN) DURING 100 HRS INSPECTION, TECH WHILE PERFORMING AD CF2008-29 FOUND LOW CLEARANCE BETWEEN THE RUDDER AND THE REAR FUSELAGE SKIN. AFTER RUDDER REMOVAL, THEY FOUND UPPER TORQUE TUBE LOWER BEARING AND LOWER TORQUE TUBE UPPER BEARING CORRODED.Oct 19, 2012 · Cndair CL2156B11215 · Rudder StructureSDR CA121019007Union · sheared(CAN) DURING APPROACH, THE NR 2 ENGINE HYDRAULIC PUMP, CAUTION LIGHT ILLUMINATED. CREW CLIMBED AND ENTERED THE HOLDING PATTERN AND ACTIONED THE QRH CHECKLIST, SUBSEQUENTLY WITH NO HYDRAULIC FLUID IN NR 2 SYS, AN ALTERNATE GEAR EXTENSION PROCEDURE WAS CARRIED OOct 15, 2012 · Dhav DHC8301 · Hydraulic System, MainSDR CA121003011Control Box · malfunctioned(CAN) PROP AUTOFEATHER ARM LIGHT DID NOT COME ON WHEN THE PILOT ADVANCED POWER FOR TAKEOFF, THE CREW REJECTED T/O AT OR AROUND 20KT. AUTOFEATHER CONTROL BOX WAS REPLACED, THE ACFT RETURNED TO SERVICE AFTER OPS CHECK OF AUTOFEATHER SYS BY HIGH POWER ENGINE RUNSep 30, 2012 · Dhav DHC8301 · Propeller Feathering/ReversingSDR CA120927006Socket · burned(CAN) BURNING ODOR IN FRONT FOUR ROWS. NO SMOKE, NO LIGHTS OUT, NO BURNED COFFEE. F/A SEEMS TO THINK ITS A PLASTIC ODOR. FOUND NR 2 COFFEE URN SOCKET BADLY BURNED, FORWARD GALLEY. REPLACED NR 2 COFFEE URN OUTLET. CHECKED SERVICEABLE, PN AC16371.Sep 26, 2012 · Dhav DHC8301 · Buffet/GalleysSDR CA121003005Engine · low torque(CAN) DURING CLIMB, APPROACHING 3000 FT, NR 2 ENGINE TORQUE SUDDENLY DROPPED TO ZERO. LOW OIL PRESSURE LIGHT ILLUMINATED. PILOT VERIFIED OIL PRESSURE ON THE OIL PRESSURE GAUGE AND IT WAS AT ZERO. FLIGHT CREW STOPPED THE ENGINE OPERATION. THE ACFT DIVERTED ASep 26, 2012 · Dhav DHC8301 · Engine BMEP/Torque IndicatingSDR CA120926003Fuel Nozzle · leaking(CAN) CREW REPORTED WHILE CLIMBING THROUGH 3000 FT, THE TORQUE OF NR 2 ENGINE DROPPED TO ZERO WITH ILLUMINATION OF OIL PRESSURE CAUTION SHORTLY THEREAFTER. ENGINE WAS SHUTDOWN IAW QRH AND DIVERTED TO NEAREST AIRPORT. ACFT LANDED SAFELY WITHOUT INCIDENT. ROOTSep 25, 2012 · Dhav DHC8301 · Fuel Injector NozzleSDR CA121010001Display · odor(CAN) ACFT DIVERTED TO AN AIRPORT DUE AFTER THE CREW OBSERVED A BURNING ODOR IN THE FLIGHT DECK. MAINTENANCE PERSONNEL WERE DISPATCHED, INVESTIGATION FOUND THE WEATHER RADAR DISPLAY WAS THE CAUSE OF THE BURNING ODOR. THE WEATHER RADAR DISPLAY WAS REPLACED, ASep 25, 2012 · Dhav DHC8301 · Weather Radar SystemSDR CA120925006Housing · damaged(CAN) RT OTBD SECONDARY DRIVE CABLE OUT HOUSING FOUND SHEARED OFF AT CABLE SWAGGED END. SWAGGED FITTING SEPARATED FROM CABLE SHEATH. RESOLVED ON W/O: 354198, TASKCARD: NR-00008, REPLACED RT OTBD SECONDARY FLEX DRIVE SHAFT, PN-745581A IAW AMM.Sep 23, 2012 · Dhav DHC8301 · Trailing Edge FlapsSDR CA120921004Skin · delaminated(CAN) DURING HEAVY MAINTENANCE INSPECTION, RT INB FLAP T/E HAS A LARGE AREA OF DELAMINATION,30" LENGTH. RIVET HOLES ELONGATED AND HEADS PULLED THROUGH THE COMPOSITE STRUCTURE. T/E REPLACED IAW AMM.Sep 20, 2012 · Dhav DHC8311 · Trailing Edge FlapsSDR CA120924003Engine · overtemp(CAN) AFTER A SCOOPING OPERATION, THE ENGINE SUFFERED AN OVERTEMP TO 962C, 19 SEC. FOLLOWED BY IFSD. THE ACFT LANDED SAFELY AND THE ENGINE WAS REMOVED AND FORWARDED FOR REPAIRS. NO DETAILS ON ENGINE CONDITION ARE AVAILABLE AT THIS TIME.Sep 18, 2012 · Cndair CL2156B11215 · Engine (Turbine/Turboprop)SDR CA120920001Windshield · sparks(CAN) CREW OBSERVED AN ELECTRICAL FLASH ACCOMPANIED WITH A SMOKE PLUME FROM THE CAPTAINS WINDSHIELD AREA FOR APPROXIMATELY 2 SECONDS. CREW CONDUCTED THE COMPANY SMOKE RECALL. CREW DECLARED A PAN CALL AS A PRECAUTION & CONDUCTED ALL RELEVANT CHECKLISTS AFTER WHSep 17, 2012 · Dhav DHC8201 · Window System WiringSDR HNAA2012091400952Element · arcedPILOTS SIDE WINDOW HEATING ELEMENT BURNED AND ARCING. R & R CAPTS SIDE WINDOW AND INSPECTED WIRES FOR DAMAGE. NO DAMAGE TO THE WIRING WAS FOUND. OPS AND LEAK CHECKED GOOD.Sep 14, 2012 · N327EN · Dhav DHC8103 · Windshield/Door Rain/Ice RemovalSDR HNAA2012090700949Tru · overheatedHOT ELECTRICAL ODOR IN FORWARD CABIN AND COCKPIT IN FLIGHT. DECLARED AN EMERGENCY. LANDED SAFELY. GROUND RAN ACFT. INSPECTED WARDROBE CLOSET AND DC CONTACTOR BOX. NO ELECTRICAL ODOR FOUND. ODOR FROM LT TRU AND TRU WAS HOT TO THE TOUCH.Sep 7, 2012 · N330EN · Dhav DHC8103 · Electrical Power SystemSDR HNAA2012090300939Bulb · failedTWO RED EMERGENCY PATH LIGHTS AT FORWARD EMERGENCY EXIT ARE INOPERATIVE. R & R 2 RED EMERGENCY PATH LIGHT AT FORWARD EMERGENCY EXIT. OPS CHECKED GOOD.Sep 3, 2012 · N327EN · Dhav DHC8102 · Emergency LightingSDR HNAA2012090300940Battery Pack · failedTWO FORWARD FLOOR EMERGENCY LIGHTS ARE INOPERATIVE. R & R EMERGENCY LIGHT BATTERY PACK AT PS2 IAW AMM 33-51-00.Sep 3, 2012 · N336EN · Dhav DHC8102 · Emergency LightingSDR HNAA2012082700932Bulb · failedEMERGENCY OVERHEAD LIGHT AT ROW 7 IS INOPERATIVE. R & R BULB FOR EMERGENCY OVERHEAD LIGHT AT ROW 7 AND SECURED LENS.Aug 27, 2012 · N327EN · Dhav DHC8311 · Emergency LightingSDR HNAA2012082700933Bulb · failedEMERGENCY FLOOR LIGHT IS INOPERATIVE, 4TH RED FROM BACK. R & R LIGHT BULB AND RESPLICED WIRE IAW AMM 33-50-01.Aug 27, 2012 · N336EN · Dhav DHC8311 · Emergency LightingSDR CA121023010Bearing · corroded(CAN) LOWER PORTION OF THE RUDDER IS FOULING ON THE TABLE STRUCTURE AT THE MOMENT IN AREA WERE CARRYING OUT THEIR INSPECTION, THAY HAVE NOTICED THAT THE RUDDER SEEMED TO HAVE MOVED LOWER AT THE POINT WERE IT HAD EVEN STARTED TO TOUCH THE RIVETS ON THE TABLE STAug 26, 2012 · Cndair CL2156B11215 · Rudder Control SystemSDR CA120829007Handle · detached(CAN) HANDLE WAS DISCOVERED, DETACHED FROM ACFT. HANDLE WAS ROUTED TO SHOPS FOR REPAIR, VISUAL INSPECTION SHOWS BEARINGS FAILED DUE TO LACK OF LUBRICATION AND CORROSION. WHEN THE BEARINGS FAILED IT ALLOWED THE HANDLE TO BECOME DETACHED FORM THE OUTER HOUSINGAug 25, 2012 · Dhav DHC8301 · Passenger/Crew DoorsSDR HNAA2012082400927Bulb · inoperativeROW 11DF SIDEWALL EMERGENCY LIGHT HAS 1 BULB INOPERATIVE. R & R BULB WITH NEW. OPS CHECKED GOOD.Aug 24, 2012 · N329EN · Dhav DHC8102 · Emergency LightingSDR CA120815006Pump · failed(CAN) NLG DID NOT EXTEND ON NORMAL GEAR EXTENSION EMERGENCY GEAR EXTENSION CARRIED OUT, GEAR EXTENSION SUCESSFUL ACFT LANDED WITH NO FURTHER ISSUES. DURING SWINGS WITH NR 2 HYDRAULICS, NOSE DOOR`S WOULD NOT OPEN DURING GEAR UP. SEQUENCE STOPED BEFORE DAMMAGEAug 14, 2012 · Dhav DHC8301 · Hydraulic Pump (Electric/Engine), MainSDR HNAA2012081300912Electronic Unit · failedON TAKEOFF ROLL AUTO FEATHER DID NOT ARM. R & R AUTOFEATHER ARM LIGHT RELAY AND NR 1 TSEU IAW MM 72-01-10. GROUND RAN IAW -8 RUNUP MANUAL. ARMED AT 90 PERCENT TORQUE. OPS CHECK GOOD.Aug 12, 2012 · N336EN · Dhav DHC8311 · Propeller Feathering/ReversingSDR HNAA2012081300913Lamp · inoperativeEMERGENCY FLOOR PATH LIGHT INOPERATIVE ROW 1. R AND R EMERGENCY FLOOR PATH LIGHT IN ROW 1, VERY FIRST ONE FORWARD, REPLACED TRACK, OPS CHECKED GOOD.Aug 11, 2012 · N327EN · Dhav DHC8311 · Emergency LightingSDR HNAA2012081300916Fixture · burnedCABIN O/H LIGHT AT 6D/F FWD FIXTURE END SMOKING. MX INSPECTED AND FOUND FWD END BURNED AND PULLED AND COLLARD CIRCUIT BREAKERS S1, S2, AND R2 PER SP 33.1.Aug 11, 2012 · N333EN · Dhav DHC8311 · Passenger Compartment LightingSDR HNAA2012081300914Connector · unsecureFLOOR EMERGENCY LIGHTS WILL NOT EXTINGUISH WITH THE LIGHT SWITCH. ONLY GOES OUT WHEN APU IS RUNNING. RESEATED CONNECTOR 3352 T3. OPS CHECKED GOOD IAW W/C 33-50-03Q.Aug 10, 2012 · N336EN · Dhav DHC8311 · Light System WiringSDR HNAA2012080600897Smoke Detector · false indicationSMOKE WARNING LIGHT ILLUMINATED WITH NO EVIDENCE OF FIRE OR SMOKE WHILE ON GATE, THEN LIGHT WENT OUT AND NR 2 CARGO BAY SMOKE DETECTOR WOULD NOT TEST. R & R NR 2 SMOKE DETECTOR IN CARGO BAY IAW AMM 26-12-00. OPS CHECKED GOOD.Aug 6, 2012 · N336EN · Dhav DHC8103 · Smoke DetectionSDR HNAA2012080600902Bulb · inoperativeEMERGENCY LIGHT AT CEILING AT ROW 6AC AND 6DF IS INOPERATIVE. INSTALLED NEW BULB. OPS CHECKED GOOD.Aug 6, 2012 · N328EN · Dhav DHC8103 · Emergency LightingSDR HNAA2012080600904Bulb · failedEMERGENCY FLOOR TRACK LIGHT IS OUT AT ROW 9DF. R & R BULB FOR EMERGENCY FLOOR LIGHT AT ROW 9DF. INSTALLED TRACK. OPS CHECKED GOOD.Aug 6, 2012 · N337EN · Dhav DHC8103 · Emergency LightingSDR HNAA2012080200889Unknown · smokeSMOKE COMING FROM NR 1 MAIN WHEEL ASSY. INSPECTED NR 1 MAIN WHEEL ASSY AND BRAKE. NO DEFECTS NOTED. NO EVIDENCE OF OVERHEATING. TAXIED ACFT. NO DEFECTS NOTED AT THIS TIME.Aug 2, 2012 · N326EN · Dhav DHC8311 · Wheel/Ski/FloatSDR HNAA2012080200890Unknown · odorSTRONG OIL ODOR DETECTED DURING TAXI. CHECKED ENGINE, APU AND ACM OIL LEVELS AND CHECKED FOR LEAKS. NONE DETECTED. GROUND RAN ACFT USING ENGINE AND APU BLEEDS. NO ODOR NOTED AT THIS TIME. OK FOR SERVICE.Aug 2, 2012 · N337EN · Dhav DHC8311 · Air Distribution SystemSDR CA120813007Indication Sys · malfunctioned(CAN) IT IS REPORTED ENGINE HAD AN OVERTORQUE. TURBOMACHINE REMOVED DUE TO NL WENT TO 27 SECONDS ABOVE TRANSIENT LIMITS. TROUBLESHOOTING ONGOING.Aug 2, 2012 · Engine BMEP/Torque IndicatingSDR CA120807005Fuel Cell · leaking(CAN) ORIGINAL FUEL CELL FAILURE. REPLACED WITH THIRD GENERATION CELL 215-64001-4. LEAK CHECKED OK.Jul 31, 2012 · Cndair CL2156B11215 · Fuel StorageSDR CA120809009Fuel Cell · failed(CAN) ORIGINAL CELL FAILURE. CELL REPLACED WITH THIRD GENERATION FUEL CELL. SYSTEM LEAK CHECKED OK.Jul 31, 2012 · Cndair CL2156B11215 · Fuel StorageSDR CA120809010Fuel Cell · failed(CAN) FAILURE OF ORIGINAL CELL. REPLACED WITH THIRD GENERATION FUEL CELL. LEAK CHECKED SERVICEABLE.Jul 31, 2012 · Cndair CL2156B11215 · Fuel StorageSDR CA120809011Fuel Cell · failed(CAN) FUEL CELL FAILURE REPLACED WITH THIRD GENERATION FUEL CELL. SYSTEM LEAK CHECKED SERVICEABLE.Jul 31, 2012 · Cndair CL2156B11215 · Fuel StorageSDR CA120809012Fuel Cell · failed(CAN) ORIGINAL CELL FAILURE. REPLACED WITH THIRD GENERATION CELL. SYSTEM LEAK CHECKED SERVICEABLE.Jul 31, 2012 · Cndair CL2156B11215 · Fuel StorageSDR JJBA20120730019Skin · damagedON LANDING, CREW OBSERVED THE TOUCHED RUNWAY LIGHT ILLUMINATE. CREW NOTIFIED MX OF THE ILLUMINATED LIGHT. GROUND MX CREW INSPECTED THE ACFT AND FOUND DAMAGE TO THE TAIL BUMPER AREA. ACFT REMOVED FROM SERVICE. PERFORMED A HARD LANDING INSPECTION, A TOUCHED Jul 30, 2012 · N857CA · Dhav DHC8301 · Fuselage Main, Plate/SkinSDR CA120807006Fuel Cell · leaking(CAN) ORIGINAL FUEL CELL FAILURE. REPLACED WITH 3 GENERATION CELL 215-64002-14. SYS LEAK CHECKED OK.Jul 30, 2012 · Cndair CL2156B11215 · Fuel StorageSDR CA120807008Fuel Cell · leaking(CAN) ORIGNAL FUEL CELL FAILURE. REPLACED WITH THIRD GENERATION FUEL CELL, PT 215-64002-8. SYSTEM LEAKED CHECKED SERVICEABLE.Jul 30, 2012 · Cndair CL2156B11215 · Fuel StorageSDR CA120807009Fuel Cell · leaking(CAN) ORIGINAL FUEL CELL FAILURE. FUEL CELL REPLACED WITH THIRD GENERATION CELL PN 215-64002-12. SYSTEM LEAK CHECKED SERVICEABLE.Jul 30, 2012 · Cndair CL2156B11215 · Fuel StorageSDR CA120809007Fuel Cell · failed(CAN) FAILURE OF A THIRD GENERATION FUEL CELL . CELL REPLACED WITH THIRD GENERATION CELL. SYSTEM LEAK CHECKED SERVICEABLE.Jul 29, 2012 · Cndair CL2156B11215 · Fuel StorageSDR CA120809008Fuel Cell · failed(CAN) ORIGINAL CELL FAILURE. REPLACED WITH THIRD GENERATION CELL. LEAK CHECKED SERVICEABLE.Jul 29, 2012 · Cndair CL2156B11215 · Fuel StorageSDR CA120809005Fuel Cell · failed(CAN) ORIGINAL CELL FAILURE. CELL REPLACED WITH THIRD GENERATION CELL. FUEL SYSTEM LEAK CHECKED SERVICEABLE.Jul 27, 2012 · Cndair CL2156B11215 · Fuel StorageSDR CA120727013Battery · overheated(CAN) DEFECT-1066780 AUXILIARY BATTERY HOT CAUTION LIGHT WITH SMOKE REPORTED COMING FROM BATTERY. POWER SHUTOFF AND FIRE CRASH HAS DISCONNECTED BATTERY. AUXILIARY BATTERY REPLACED. TESTED SERVICEABLE IAW AMM 24. REMOVED BATTERY ROUTED TO O/H SHOP FOR INSPJul 25, 2012 · Dhav DHC8311 · Battery/Charger SystemSDR CA121019001Turbine Blades · fractured(CAN) UNUSUAL NOISE DURING START. PILOT REPORTED UNUSUAL NOISE DURING NR 1 ENGINE START, WHEN PROPELLER PITCH CHANGED FROM FEATHER TO UN-FEATHER POSITION. PILOT SHUTDOWN THE ENGINE. MECHANIC PERFORMED ENGINE RUN AND FOUND ENGINE SUFFERED SERIOUS VIBRATION WHJul 23, 2012 · Dhav DHC8301 · Turbine SectionSDR CA120723013Starter Gen · failed(CAN) APPROX 1 HR AFTER DEPARTURE, THE PILOTS NOTICED NR 2 DC GEN WARN LIGHT CAME ON AND AFTER A MINUTE OR 2, THE NR 2 DC GEN HOT LIGHT ILLUMINATED. THE PILOTS SELECTED THE 2 DC GEN OFF IAW QRH. THE NR 2 DC GEN HOT LIGHT EXTINGUISHED APPROXIMATELY 20-25 MINUTJul 23, 2012 · Dhav DHC8314 · Starter-GeneratorSDR JJBA20120717009Lens · detachedDURING PREFLIGHT, CREW NOTICED THE EMERGENCY EXIT SIGN BY MAIN CABIN DOOR WAS INOPERATIVE. GROUND MX CREW FOUND THE LENS FOR THE EXIT SIGN HAD COME OFF. ATTACHED THE LENS TO THE SIGN AND PERFORMED AN OPS CHECK THAT PRODUCED SATISFACTORY RESULTS.Jul 17, 2012 · N363PH · Dhav DHC8202 · Emergency LightingSDR CA120716019Windshield · cracked(CAN) AFTER LANDING, THE PILOT`S WINDSHIELD CRACKED. MAINTENANCE INSPECTED THE WINDSHIELD AND DETERMINED CRACK TO BE IN THE OUTER FACE PLY. IT WAS INSPECTED SERVICEABLE FOR CONTINUED USE AS PER AMM 56-10-11 PG 215. THE AIRCRAFT WAS THEN FLOWN TO CALGARY. THEJul 12, 2012 · Dhav DHC8315 · Flight Compartment Windows
Back to Pratt & Whitney Canada PW123