SDR QXEA2011081100644Panel · corrodedPANEL 524FT LANDING HAS CORROSION. REMOVED CORROSION AND COMPLETED REPAIR IAW RD 8/4-57-442.SDR CA110802002Heater · burnedDURING DESCENT PASSING 6000 FT, THE ENGINE ADAPTOR HEAT 2 CAUTION LIGHT ILLUMINATED. EACH TIME THE BYPASS DOOR NR 2 WAS PRESSED, THE ACFT CIRCUIT BREAKER FOR THE NR 2 ENGINE LIP HEATER WOULD POP. LINE MX INVESTIGATION IDENTIFIED THAT THE ENGINE INTAKE ADAPTOSDR CA110801003Power Supply · failedNR 2 STALL SYS FAIL AND PUSHER SYS FAIL ILLUMINATED DURING T/O ROLL AROUND A/S 60KT. BOTH C/L WENT OFF DURING TAXI BACK TO THE GATE. MECHANIC REPLACED NR 2 SPM AS SUGGESTED BY BITE "NO DATA FROM NR 2 SPM". AFTER ABOVE MX ACTION, THE ACFT DISPATCHED WITH 1 HSDR CA110803017Bolt · looseWHILE CARRYING OUT THE OPERATOR REQUIRED FLEET INSP, LINE MX IDENTIFIED 1 LOOSE TIE BOLT ON THE REF WHEEL ASSEMBLY (BOLT COULD BE TURNED WITH FINGERS). AFTER REMOVAL THE AFFECTED WHEEL WAS RETURNED TO THE OPERATOR`S MATERIALS STORE. ON RECEIPT AT THE STORE FURSDR CA110920006Bypass Valve · malfunctioned(CAN) DURING CLIMB OUT, NR 2 ENGINE OIL TEMP HIGH. 102 C FOR APPROX 3 MINUTES. MX REPLACED THE THERMAL BYPASS VALVE.SDR QXEA2011072200553Web · corrodedAFT CARGO, LT FLOOR WEB STA 714.6 - 783.1 HAS SEVERAL AREAS OF CORROSION. REMOVED CORROSION IAW SRM 51-21-00-00-02. HFEC CONFIRMED CRACK FREE REF NTM, 51-00-02-250-801 UT REMAINING THICKNESS MEASURED .047" IN REF NTM 51-42-05-02-01. COMPLETED REPAIR IAW TASDR CA110721001Display · overheatedPILOT REPORTED FUMES IN THE COCKPIT. ACFT LANDED UNEVENTFUL AT DESTINATION AIRPORT. ODOR ORIGINATED FROM NR 1 ARCDU ALSO FELT HOT TO THE TOUCH. CREW DECLARED AN EMERGENCY. NR 1 ARCDU REPLACED. ARCDU AND OTHER ACFT SYSTEMS WILL BE POWERED AND MONITORED TO CSDR CA110726004Fadec · malfunctionedNR 2 ENG FADEC CAUTION LIGHT ILLUMINATED ALONG WITH A POWERPLANT MESSAGE ON ED. MX INTERROGATED CDS, FOUND FAULT CODE 776A FOR NR 2 ENGINE ON 18TH OF JULY 2011. FURTHER INTERROGATION OF CDS FOUND SEVERAL FAULT CODES FOR CH A OF NR 2 ENG FADEC WHICH INCLUDE 7SDR CA110803003Oil System · low pressure(CAN) DURING CRUISE, A LOSS OF OIL PRESSURE OCCURRED. THE ENGINE WAS SHUTDOWN AND SECURED BEFORE AN UNEVENTFUL SINGLE ENGINE LANDING WAS PERFORMED AT THE DEPARTURE AIRPORT. TROUBLESHOOTING IS ON-GOING. WILL INVESTIGATE TO ESTABLISH ROOT CAUSE AND SUPPLEMENT SDR CA110719001Actuator · inoperativeENGINE NR 2, HIGH OIL TEMPERATURE REACHING RED BAND DURING CLIMB. REPLACED OIL COOLER OUTLET FLAP ACTUATOR, ENGINE RUN SATISFACTORY IAW AMM TASK 79-21-31.SDR CA110718010Pump · failedENGINE NR 1 FUEL CAUTION ILLUMINATION DURING TAKEOFF POWER ONLY. PRIMARY EJECTOR PUMP FOUND TO AT FAULT, REPLACED.SDR CA110714004Coffeemaker · shortedDURING CLIMB OUT, F/A RECEIVED A MILD ELECTRICAL SHOCK FROM COFFEE MAKER. NO INJURY SUSTAINED. THE F/A WAS WIPING OUT THE TRAY WHICH HOLDS THE COFFEE KETTLE WITH A WET CLOTH AND ACCIDENTLY TOUCHED THE ON/OFF SWITCH WHERE THE ELECTRIC SHOCK TOOK PLACE. COFFEESDR CA110708018Tube · chafedHAD A HYD FLUID LEAK ON TURN AROUND, NEXT FLIGHT WAS CANCELED, FURTHER INSPECTION REVEALED A PIN HOLE IN A HYD TUBE LOCATED IN THE RT NACELLE. HOLE WAS CAUSED BY MISROUTING OF HYD TUBES RESULTING IN FOULING CONDITION. BOTH TUBES WERE REPLACED AND A FLEET CAMSDR CA110706005Pump · crackedNR 2 EDP LOW PRESSURE CAUTION LIGHT DURING DESCENT. ALL NR 2 HYD PRESSURE WAS LOST. THE OPERATOR REPORTED THAT THE NR 2 EDP WAS FOUND CRACKED (SPLIT) IN 2.SDR CA110705001Pcu · malfunctionedCREW MANUALLY SHUTDOWN (IFSD) LT ENGINE DUE TO A PEC FAULT & POWERPLANT MESSAGE FOLLOWED BY PROP OVERSPEED. AT FL 9500, TORQUE WAS INDICATING 106 PERCENT, POWER WAS THEN REDUCED AND WITH MCL SET AT 850, RPM WENT TO 1064. THE FAULT CODES RETRIEVED AFTER THE ASDR CA110628008Selector Valve · faultyDURING CRUISE, CAPTAIN NOTICED 3 RED UNSAFE LIGHTS ILLUMINATED ON THE ANNUNCIATOR PANEL, AS WELL AS THE UNSAFE LIGHT IN THE MLG HANDLE. F/O AND CAPTAIN NOTICED MLG DID NOT EXTEND, AS THERE WERE NO SOUNDS. A GO AROUND WAS INITIATED. COMPLETED ALTERNATE MLG SDR CA110711003Engine · odor(CAN) SMOKE IN CABIN DURING REVENUE FLIGHT, ON APPROACH, THE LAVATORY SMOKE DETECTOR WAS ACTIVATED. ACFT LANDED WITH SMELL IN CABIN AND COCKPIT. ENGINE NR 2 WAS REMOVED AFTER OBSERVING A LOW OIL LEVEL AND TRACES OF OIL IN THE INLET.SDR CA110627017Pump · failedON JUNE 25TH, FLIGHT DIVERTED BACK TO DEPARTURE, DUE TO A MASTER CAUTION LIGHT ASSOCIATED WITH NR1 ENGINE HYD PUMP LIGHT. ACFT STATUS WAS DECLARED, AN EMERGENCY AND ALSO REQUESTED FIRE TRUCK ON ARRIVAL. FLIGHT CREW PERFORMED THE ENTIRE CHECK LIST (QRH) FOR THSDR CA110707003Tire · flatRT INBD MLG WHEEL/RIM ASSY WAS FOUND FLAT IAW THE ACFT MM, AS THE RT MLG INBD WHEEL TIRE WAS FOUND FLAT, THE RT MLG OTBD (NR 4) MAIN WHEEL WAS REPLACED.SDR CA110706006Windshield · crackedDURING CRUISE AT FL16, CAPTAIN WINDOW CRACKED AND DISTURBING CAPTAIN`S VIEW AS SUCH THE CREW DECIDED TO RETURN TO THE BASE. THE CRACK WAS OCCURED AFTER 3-4 MINUTES OF WINDOW HEATING SWITCH ON. LT WINDSHIELD REPLACED.SDR CA110627014Attach Fitting · damagedDURING A "C-CHECK, MX FOUND A HALF CRADLE FROM THE RT OTBD WING FRONT SPAR TO FUSELAGE ATTACHMENT POINT. THE HALF OF CRADLE HAD FALLEN OUT OF THE ASSY. ON REMOVAL OF HARDWARE IT WAS NOTED THAT THE BARREL NUT WAS ALSO CRACKED. ALL HARDWARE REPLACED IN THE RTSDR CA110621006Tire · failedDURING TAXI, NR 2 MWT BURST DUE TO FLAT SPOT. R & R NR 1 AND NR 2 MWT ASSY IAW AMM TASK 32-41-01, PAGES 401-421.SDR CA110616001Attach Fitting · brokenDURING A ROUTINE SERVICE CHECK, MX TECH FOUND THE NLG RETRACT ACTUATOR TOP MOUNT ATTACHMENT LUG HAD BROKEN AWAY FROM THE AIRFRAME. ACFT WAS REMOVED FROM SERVICE PENDING FULL INVESTIGATION. THIS SDR IS OPEN UNTIL INVESTIGATION/REPAIR IS COMPLETED.SDR CA110617003Plate · damagedDURING "A"-CHECK FOUND DAMAGE ON LT NACELLE FIREWALL INTERFACE PLATE, PN 82454317 AND ON HYD TUBE, PN 82974222-001. THE HYD TUBE IS FIXED ON THE INTERFACE PLATE WITH A WASHER AFT OF THE INTERFACE PLATE AND A WASHER/NUT ON THE FWD SIDE OF THE PLATE. THE AFT WASDR CA110616005Oil Cooler · crackedINFLIGHT SHUTDOWN ON NR 2 ENGINE DUE TO CRACKED OIL COOLER. THE CRACK HAD DEVELOPED ALONG A REPAIRED WELD, THIS CAUSED LOSS OF ENGINE OIL, ENGINE SHUTDOWN AND ACFT DIVERSION TO THE NEAREST AIRPORT. PART HAS BEEN REPAIRED. THE LENGTH OF THE CRACK IS 71MM. THESDR CA110711012Starter Gen · failedNR 2 DC GENERATOR WARNING LIGHT ILLUMINATED IN FLIGHT LINE MX INVESTIGATION/TROUBLESHOOTING IDENTIFIED THAT THE STARTER/GENERATOR COOLING FAN HAD LIBERATED FROM THE AFT END OF THE UNIT. ALL DAMAGED PARTS WERE ACCOUNTED FOR WITHIN THE ENGINE BAY. THE FAILED USDR CA110613014Bearing · roughAIR VALVE CAP WAS DROPPED INSIDE NR 2 WHEEL ASSY, WHEEL HAD TO BE REMOVED TO ACCESS THE CAP. ON REMOVAL OF THE WHEEL, THE BEARING WAS VERY DIFFICULT TO REMOVE, THERE WAS NOT SUFFICIENT GREASE. NR 3 AND NR 4 WHEEL ASSY WERE CONFIRMED TO HAVE BEEN REPLACED INSDR CA110610011Pump · brokenFLIGHT CREW DECLARED EMERGENCY DUE TO LOSS OF NR1 HYD FAILURE. AFTER UNEVENTFUL LANDING, MX PERFORMED A FULL INSP TO THE ACFT WHERE IT WAS DISCOVERED THAT THE NR1 EDP BOTTOM PLATE CAME OFF. ALL THE HYD FLUID WAS DEPLETED DUE TO THE MISSING PLATE. MX REPLACED SDR CA110613009Switch · unserviceablePILOTS REPORT: "ON APPROACH, CAPTAIN FLYING, TOUCHED AILERON TRIM TO TRIM RT. TRIM PRESSED FOR LESS THAN 1 SECOND, TRIM CONTINUED TO TRIM TO THE RT AND ACFT ROLLED AND CONTINUED TO ROLL RIGHT. CAPTAIN FORCEFULLY MAINTAINED LEVEL FLIGHT WHILE THE F/O TRIMMED TSDR CA110609003Oil Cooler · failedDURING AN APPROACH CHECK FLIGHT, THE NR1 ENGINE OIL TEMPERATURE EXCEEDED ITS NORMAL OPERATING RANGE TO A YELLOW ARC CAUTION OF 113C. THE ACFT DID AN UNSCHEDULED LANDING. MX DETERMINED THE ROOT CAUSE TO BE A FAILED OIL COOLER - AIR OUTLET FLAP ACTUATOR. THE OSDR CA110524002Handle · unsecureMASTER WARNING INDICATION WENT OFF DURING FLIGHT FOR A FUSELAGE DOOR INDICATION (FWD BAGGAGE DOOR) ON ARRIVAL, AN INITIAL INSPECTION TOOK PLACE AND HANDLE APPEARED TO BE FLUSHED AND LATCHED. MX PERSONNEL TOOK A CLOSER INSPECTION AND REVEALED THAT THE CENTERSDR CA110524003Steering Unit · malfunctionedDURING NORMAL LANDING, AFTER TOUCHDOWN, NOSE WHEEL CONTACT AND SPOILER DEPLOYMENT, THE ACFT SWERVED TO THE LEFT (INTO WIND), PROGRESSIVE RUDDER AND RUDDER NOSE WHEEL STEERING WAS APPLIED UNTIL FULL DEFLECTION BY BOTH PILOTS BEFORE CONTROL WAS REGAINED MORE THASDR QXEA2011051600339Oil System · low pressureDURING CRUISE, NR 2 ENG OIL PRESSURE WARNING ILLUMINATED, OBSERVED NR 2 OIL PRESSURE INDICATION SHOWING ALL DASHES, THEN ZERO, THEN ALL DASHES AGAIN. NR 2 PEC CAUTION LIGHT ILLUMINATED, FOLLOWED BY A "POWERPLANT" MESSAGE ON E.D. CONDUCTED NR 2 ENGINE FAILURESDR CA110516017Oil System · low pressure(CAN) OIL PRESSURE LOSS/IFSD DURING CRUISE AT FL240, THE CREW HAD TO SHUT THE RIGHT ENGINE DOWN DUE TO LOW OIL PRESSURE. THE ACFT WAS DIVERTED FOR A SAFE SINGLE ENGINE LANDING. SEVERAL FAULT CODES WERE RECORDED DURING THE EVENT, INCLUDING TURBOMACHINE CHIP DSDR CA110525001Actuator · inoperativeDURING THE CLIMB, THE CREW NOTICED OIL TEMP INDICATION FOR NR 2 ENGINE WAS HIGH, 108C FOR AROUND 10 SEC OIL TEMP DECREASED AFTER THE CREW RETARDED NR 2 ENGINE POWER. THE FLIGHT WAS DIVERTED TO BASE AS PRECAUTION. MX CONFIRMED THAT ACOC ACTUATOR IS INOPERATIVSDR QXEA2011050900327Engine · leakingDURING DESCENT, FUMES AND HAZE APPEARED IN THE COCKPIT AND CABIN. DONNED MASKS & PERFORMED SMOKE CHECKLIST. PASSENGERS & F/A COMPLAINED OF NAUSEA & DIZZINESS. HOT CHEMICAL ODOR. LANDING UNEVENTFUL. GROUND IDLE RUN ODOR RETURNED. FERRIED, REPLACED HYD LINESDR CA110711011Spring · brokenFLIGHT CREW REPORT AUTOPILOT OSCILLATIONS IN PITCH AXIS DURING CLIMB & CRUISE. AS A RESULT OF THE TROUBLESHOOTING INVESTIGATION OF THE FLIGHT CREW LISTED DEFECT, LINE MX DISCOVERED THAT THE ELEVATOR PCU CENTERING SPRING HAD FAILED IN THAT 1 LEG OF THE SPRING SDR CA110428004Bearing · failed(CAN) DURING ACFT TOWING, CREW FOUND NOISE COMING FROM THE NR 1 MLG WHEEL ASSY. FURTHER INSPECTION FOUND THE WHEEL BEARING FAILURE.SDR CA110427012Windshield · failed(CAN) DURING CRUISE RT WINDSHIELD OUTER PANE SHATTERED 1 HR INTO FLIGHT, ACFT RETURNED TO BASE. RIGHT WINDSHIELD REPLACED.SDR CA110427015Line · failed(CAN) DURING APPROACH, FLIGHT CREW NOTICED NR 2 SYS HYDRAULIC FLUID LEVEL DROPPING. NR 2 HYD ISOLATION VALVE CLOSED & ACFT LANDED WITHOUT ISSUE. ABNORMAL STOP ON RUNWAY AND NR 2 ENGINE SHUTDOWN, "T" HANDLE PULLED. 10 PERCENT HYDR FLUID STILL REMAINING IN NR 2SDR CA110428014Proximity Sensor · failed(CAN) ON DEPARTURE, THE "FUSELAGE DOORS" WARNING LIGHT AND MASTER WARNING LIGHT ILLUMINATED. THE CREW LEVELED OFF AT 3000 FT AND CONDUCTED THE RELEVANT QRH CHECKLIST. THE MFD DOORS PAGE SHOWED THE REAR LT EMERGENCY EXIT WAS OPEN. THE WARNING LIGHT CONTINUED SDR QXEA2011042000289Control Unit · failedAFTER TAKEOFF, BOTH PROPS AT 1020 NORMAL. BUT WHEN THE PROPS WERE BACK TO 900 THE RT PROP WAS AT 880; THEN WHEN WENT TO 850 THE RT PROP WENT TO 830. SHORTLY THEREAFTER THE NR2 PEC CAUTION CAME ON, FOLLOWING THE CHECKLIST PUT BOTH CL TO MAX, THE RT PROP WENT TOSDR CA110420004Control Unit · malfunctioned(CAN) AFTER TAKEOFF, BOTH PROPS AT 1020 RPM WHICH IS NORMAL. BUT WHEN I PULLED THE PROPS BACK TO 900 RPM, THE RT PROP WAS AT 880 RPM. THEN WHEN I WENT TO 850 RPM, THE RT PROP WENT TO 830 RPM. SHORTLY THEREAFTER, THE NR 2 PROP ELECTRONIC CONTROL, PEC, CAUTIOSDR QXEA2011041400281Skin · corrodedFOUND CORROSION ON SKIN UNDER TCAS ANTENNA. REPAIRED IAW SRM 51-21-00-00-02, RD8/4-53-505 AND SRM 51-21-10-02-01.SDR CA110420003Valve · malfunctioned(CAN) DEICE PRESSURE CAUTION LIGHT. RT INBRD DEICE ADVISORY LIGHT ON. TAIL DOES NOT ILLUMINATE. ADVISORY LIGHT DID ILLUMINATE ON DESCENT IN WARMER OAT. R & R L/E 341AR AND DDV NR 5.SDR CA110412004Lug · fractured(CAN) DURING THE INSPECTION OF THE MLG DOWNLOCK ACTUATOR PIN ON THE STABILIZER BRACE, AN OPERATOR FOUND ON RT MLG STABILIZER BRACE AT DOWNLOCK ACTUATOR ATTACHMENT, A FRACTURED LUG. THE PART HAS BEEN INSTALLED SINCE DELIVERY. INVESTIGATION IS BEING COMPLETED.SDR CA110419007Controller · malfunctioned(CAN) POWERPLANT MESSAGE ON ED DURING CLIMBOUT. WIRING CHECKS PERFORMED AND NR 2 PEC REPLACEMENT IAW TASK 61-20-36-000-801 AND 61-20-36-400-801 DUE TO NR 1 CHANNELS A & B POWERPLANT FAULT 456 AND NR 2 CHANNEL B POWERPLANT FAULTS 456 AND 794. CLEARED FAULTS ASDR QXEA2011041200284Unknown · odorF/A'S ADVICE "ELECTRICAL" ODOR IN AFT GALLEY. STRONGER FROM VENTS AFT BULKHEAD. UPON ARRIVAL TO ACFT DID NOT NOTICED ANY ELECTRICAL ODOR. REMOVED AFT GALLEY CONTROL PANEL . NO ELECTRICAL ODOR NOTED. REINSTALLED AFT GALLEY CONTROL PANEL AS REQUIRED. INSPECTSDR QXE2011F00000Outflow Valve · failedON DEPARTURE, THE ACFT FAILED TO PRESSURIZE, RAN CHECKLIST AND FAIL TO PRESSURIZE MANUAL. ALSO, INFLIGHT WE WERE UNABLE TO GET HEAT. RETURNED TO DEPARTURE. LANDING UNEVENTFUL. HEAT WORKED FINE ON GROUND. GROUND TEST OF PRESSURAZIATION WITH MX FAILED, FERRSDR CA110425006Bypass Valve · leaking(CAN) SMOKE IN CABIN DURING FLIGHT, OIL FUMES AND SMOKE ENTERED THE CABIN. EMERGENCY WAS DECLARED AND THE ACFT RETURNED TO THE DEPARTURE POINT FOR AN UNEVENTFUL LANDING. POST FLIGHT INSPECTION FOUND A LEAK ON THE AIRFRAME OIL COOLER BYPASS VALVE WHICH APPARE
Back to Pratt & Whitney Canada PW150A