SDR CA120322007Nut · loose(CAN) LT OTBD WHEEL RIM FOUND BY THE F/O TO HAVE 9 LOOSE, ABLE TO BE TURNED BY FINGERS, NUTS AND 1 MISSING DUE TO BOLT SHEARED. THIS ISSUE IS RE-OCCURRING ON THE QANTAS LINK FLEET DESPITE CONTINUED EFFORTS BY THE OPERATOR TO RESOLVE THE ISSUE. THE WHEEL IN DNov 18, 2011 · Bombdr DHC8400 · Wheel/Ski/FloatSDR CA111128002Sequence Valve · malfunctioned(CAN) NOSE GEAR DOOR AND GEAR UNSAFE LIGHT REMAINED ILLUMINATED AFTER GEAR RETRACTION. PERFORMED ALTERNATE EXTENSION AND LANDED. MAINTENANCE FOUND EXTERNAL DAMAGE TO NLG DOORS. NOSE GEAR SOLENOID SEQUENCE VALVE REPLACED AND BOTH NG LOCK SENSORS REPORTED TOO Nov 15, 2011 · Bombdr DHC8400 · Landing Gear Retraction/Extension SystemSDR CA111128001Buss Bar · broken(CAN) PROP DEICE CAUTION LIGHT ON. RAN CHECK LIST, LIGHT REMAINED ON FOR NR 2 PROP. MAINTENANCE FOUND NR 6 BLADE BUSS BAR BROKEN. REPLACED BUS BAR.Nov 14, 2011 · Bombdr DHC8400 · Ice/Rain Protection System WiringSDR CA111206013Switch · shorted(CAN) THE F/A RECEIVED AN ELECTRICAL SHOCK FROM THE LT COFFEEMAKER. THE COFFEEMAKER WAS REPLACED, PN 400-1794-02, SN 11-01-47902, A/C TSN 1196, CSN 794.Nov 6, 2011 · Bombdr DHC8400 · Buffet/GalleysSDR CA111107001Wire · burned(CAN) DURING TAXI, CREW HEARD A LOUD BANG IN FLT DECK ASSOCIATED WITH NUMEROUS AC CIRCUIT BREAKERS (CBS) POPPING. AC FUEL PUMP & RT WINDSHIELD HEAT CBS AMONG THOSE POPPED. INITIAL INSPECTION, IT LOOKS LIKE 5 CABLES ARE COMPLETELY BURNED THROUGH AND 6 OTHER CNov 4, 2011 · Bombdr DHC8400 · Electrical Power System WiringSDR CA111103001Windshield · broken(CAN) RT WINDSHIELD SHATTERED, QRH ACTION ABOUT 17,000 FT, NO DECOMPRESSION, NORMAL LANDING ACCOMPLISHED. INNER PANE AND MIDDLE PANE FOUND INTACT. OUTER PANE FOUND CRACKED. NO DECOMPRESSION HAPPENED. WINDSHIELD REPLACED.Oct 31, 2011 · Bombdr DHC8400 · Flight Compartment WindowsSDR CA111101002Bypass Switch · inoperative(CAN) DEFECT: NR 1 FUEL FILTER BYPASS LIGHT CAME ON DURING TAXI OUT. NR 1 FUEL FILTER AND NR 1 FUEL FILTER BYPASS SWITCH REPLACED. FADEC CODE RESET. RUN UP C/O LEAK CHECK C/OUT, CHECKED SERVICEABLE.Oct 30, 2011 · Bombdr DHC8400 · Aircraft Fuel Distribution SystemSDR CA111031001Tire · separated(CAN) ON T/O ROLL PILOT ABORTED DUE TO SIGNIFICANT VIBRATION FROM NOSE AREA. AFTER ABORTED T/O AND RETURN TO BLOCKS, ACFT WAS NOTED WITH NR 2 NOSE WHEEL TREAD SEPARATION ADDITIONAL DAMAGE INCLUDED. RT AFT NOSE DOOR CONNECTING ROD BROKEN. TAXI LIGHT HARNESS POct 28, 2011 · Bombdr DHC8400 · TireSDR CA111206012Switch · shorted(CAN) THE F/A RECEIVED AN ELECTRICAL SHOCK FROM THE LT COFFEEMAKER. THE COFFEEMAKER WAS REPLACED, PN 400-1794-02, SN 11-03-48204. ACFT TSN 1157, CSN 765.Oct 24, 2011 · Bombdr DHC8400 · Buffet/GalleysSDR CA111206011Switch · shorted(CAN) THE F/A RECEIVED AN ELECTRICAL SHOCK FROM THE LT COFFEEMAKER. THE COFFEEMAKER WAS REPLACED, PN 400-1794-02, SN 11-03-48291, ACFT TSN 1132, CSN 746.Oct 23, 2011 · Bombdr DHC8400 · Buffet/GalleysSDR CA111024012Indicator · intermittent(CAN) INTERMITTENT FUEL QTY INDICATION. IN FLIGHT AND ON GROUND FUEL QTY INDICATOR ERRATIC OR OVER READ WITH NO REPORTED FAULTS LOGGED ON THE REPEAT INDICATOR WHEN INSPECTED BY MX PERSONNEL. WE RECENTLY FACED AN INTERMITTENT FUEL INDICATION SNAG. PILOTS REPOOct 20, 2011 · Dhav DHC8103 · Fuel Quantity IndicatorSDR CA111206010Switch · shorted(CAN) THE F/A RECEIVED AN ELECTRICAL SHOCK FROM THE LT COFFEEMAKER. THE COFFEEMAKER WAS REPLACED. ACFT TSN 30, CSN 19.Oct 20, 2011 · Bombdr DHC8400 · Buffet/GalleysSDR CA111019015Door · out of adjust(CAN) FUSELAGE DOORS WARNING LIGHT FOR 1R DOOR DURING CLIMBING. NO PRESSURIZATION LOSS OBSERVED. OFFICER CONTACTED CABIN CREW AND NO ISSUES WERE NOTED. OFFICERS DECIDED THROUGH CONSULATION WITH MOC & SOCC TO RETURN TO DEPARTURE. MX REMOVED DOOR, CLEANED SEOct 18, 2011 · Dhav DHC8103 · Service DoorsSDR CA111018005Sensor · inoperative(CAN) IN-FLIGHT RETURN DUE TO LOW OIL PRESSURE. NO MASTER WARNING ASSOCIATED - PSI FLUCTUATED FROM 2PSI TO 68PSI. OIL TEMP REMAINED STEADY AT 71DEG. MX REPLACED NR 2 ENGINE OIL PRESSURE SENSOR AND CONNECTOR CLEANED AND ACFT PUT BACK TO SERVICE.Oct 17, 2011 · Bombdr DHC8400 · Engine Oil PressureSDR CA111017001Actuator · failed(CAN) DURING APPROACH GEAR SELECTED DOWN LT RED INDICATION FOR LT MAIN GEAR AND LT DOOR INDICATING AMBER. GO AROUND PERFORMED GEAR SELECTED UP AND THEN DOWN AGAIN ALL INDICATING GREEN, ACFT LANDED WITHOUT ISSUE. ACFT FERRIED BACK TO BASE TO INSPECT FURTHEROct 16, 2011 · Bombdr DHC8400 · Landing Gear ActuatorSDR CA111017002Heater · failed(CAN) DURING CRUISE, WINDSHIELD HOT AND WINDSHIELD CONTROL CAUTION LIGHTS CAME ON. THE CREW CONFIRMED BY THEIR HAND THAT WINDSHIELDS WERE NOT ACTUALLY HEATED AND CANNOT BE RECOVERED, THE CONDITION WITH RECYCLING CIRCUT BREAKER. RETURNED TO THE ORIGIN AS ICINOct 15, 2011 · Bombdr DHC8400 · Windshield/Door Rain/Ice RemovalSDR NSVA2011256Engine · malfunctionedAIR RETURN, EMERGENCY DECLARED, LOW OIL PRESSURE, RIGHT ENGINE SHUT DOWN. ACFT LANDED SAFELY AND WAS TOWED BACK TO GATE. ENGINE CHANGED.Oct 14, 2011 · N199WQ · Saab 340B · Engine (Turbine/Turboprop)SDR CA111018007Access Door · missing(CAN) A PASSENGER REPORTED THAT THEY SAW A PANEL FALL OFF THE ACFT ON TAKEOFF. IT WAS CONFIRMED THAT THE LT HYD SERVICE PANEL DOOR WAS MISSING. THE ACFT RETURNED TO THE DEPARTURE AIRPORT WITH NO ISSUES. IT IS SUSPECTED THAT THE DOOR WAS LEFT UNLATCHED AFTER Oct 14, 2011 · Bombdr DHC8400 · Nacelle/Pylon, Main FrameSDR CA111019010Engine · making metal(CAN) UPON LEVELING OFF AT FL100, THE CREW RECEIVED A LOW OIL PRESSURE WARNING FOLLOWED BY A PROPELLER ELECTRONIC CONTROL FAULT. THE ENGINE WAS SHUTDOWN AND THE ACFT UNEVENTFULLY LANDED SINGLE ENGINE. TROUBLESHOOTING FOUND LARGE CHIPS ON 1 OF THE ENGINE`S CHIOct 14, 2011 · Bombdr DHC8400 · Engine (Turbine/Turboprop)SDR CA111018002Fadec · inoperative(CAN) ON DESCENT PASSING APPROX 7,500FT, NR 2 ENG FADEC CAUTION LIGHT ILLUMINATED FOLLOWED BY NR 2 FADEC WARNING LIGHT AND NR 2 ENG OIL PRESSURE LIGHT. WE CONDUCTED THE ENGINE SHUTDOWN DRILL AND COMPLETED THE QRH. THE LANDING WAS UNEVENTFUL. REPORT FROM LINOct 12, 2011 · Bombdr DHC8400 · Fuel Controlling SystemSDR CA111019006Oil System · low pressure(CAN) INBOUND, DURING DESCENT, THE CREW GOT FADEC FAULTS, LOW OIL PRESSURE WARNING FOLLOWED BY ENGINE SHUTDOWN. AN UNEVENTFUL SINGLE ENGINE LANDING WAS MADE AT DESTINATION. TROUBLESHOOTING IS ON-GOING.Oct 12, 2011 · Dhav DHC8103 · Engine (Turbine/Turboprop)SDR CA111011014Bypass Valve · faulty(CAN) IN CLIMB NR 1 ENGINE OIL TEMP ROSE TO 117 DEGREES. POWER LEVERS PULLED BACK 20 PERCENT, TEMPERATURE DECREASED TO 117 DEGREES AND REMAINED STILL UNTIL DESCENT. TROUBLESHOOTING C/O IAW FIM AND BYPASS VALVE FOUND TO BE AT FAULT. BYPASS VALVE REPLACED AND Oct 7, 2011 · Bombdr DHC8400 · Turbine Engine Oil SystemSDR CA111115006Selector Valve · failed(CAN) WHEN LANDING GEAR SELECTED DOWN, 3 GEAR UNSAFE BUT NO MOVEMENT. 3 TO 4 MINUTES LATER ALL GEAR EXTENDED DOWN AND LOCKED AS NORMAL. MAINTENANCE FOUND THE LANDING GEAR SELECT VALVE DOWN SOLENOID COIL OUT OF RANGE. SELECTOR VALVE WAS REPLACED.Oct 5, 2011 · Bombdr DHC8400 · Landing Gear Retraction/Extension SystemSDR CA110930014Pump · leaking(CAN) AT TOP OF DESCENT, THE NR 1 ENG HYD PUMP CAUTION LIGHT ILLUMINATED WITH THE NR 1 HYD PRESSURE AND HYD QTY WERE READING ZERO. FLT CREW DID FOLLOW THE APPROPRIATE CHECKLISTS IN THE QRH, AND THEN THEY PROCEED TO AIRPORT FOR LANDING. FLT CREW DECLARED AN ESep 28, 2011 · Bombdr DHC8400 · Hydraulic Pump (Electric/Engine), MainSDR CA111011008Servo · inoperative(CAN) "DURING FLIGHT CONTROL CHECK, SIGNIFICANT RESISTANCE WAS FELT IN ROLL CONTROL ALONG WITH A SOUND SIMILAR TO A MOTOR BEING FORCED. AFTER SEVERAL ATTEMPTS THE RESISTANCE RELEASED AND A CLINK WAS HEARD. AUTO PILOT WAS NOT ENGAGED DURING THIS CHECK" MX RESep 24, 2011 · Bombdr DHC8400 · Autopilot Main ServoSDR CA111206009Switch · shorted(CAN) THE F/A RECEIVED AN ELECTRICAL SHOCK FROM THE LT COFFEEMAKER. THE COFFEEMAKER WAS REPLACED, PN 400-1794-02, SN 11-03-48291, ACFT TSN 210, CSN 133.Sep 24, 2011 · Bombdr DHC8400 · Buffet/GalleysSDR CA110923002Line · leaking(CAN) DURING FLIGHT, CREW REPORTED COMPLETE FLUID LOSS FROM THE NR 2 HYD SYSTEM. NR 2 ISO LIGHT ILLUM FOR A SECOND, SO THE CREW LOOKED AT THE HYD QTY FOUND IT PEGGED AT ZERO, THEN THE ISO LIGHT ILLUM SOLID AND THE CREW NOTED THE HYD PRESSURE INDICATOR WAS PEGSep 22, 2011 · Bombdr DHC8400 · Hydraulic System, MainSDR CA111004001Actuator · leaking(CAN) THREE ABORTED TAKEOFFS DUE TO CREW REPORTS OF PROP "SURGING" AND FAIL TO REACH 1020 RPM. MX REPLACED THE PCU, PEC, OSG, AND THEN REPLACED THE PROP ASSY. AFTER REMOVING THE PROP ACTUATOR CYLINDER ASSY, DETERIORATION OF THE PISTON SEAL AND BACKUP RINGS WSep 22, 2011 · Bombdr DHC8400 · Propeller Controlling SystemSDR CA111206008Switch · shorted(CAN) THE F/A RECEIVED AN ELECTRICAL SHOCK FROM THE LT COFFEEMAKER. THE COFFEEMAKER WAS REPLACED, PN 400-2475-01, SN 07-07-41712, ACFT TSN 831, CSN 555.Sep 22, 2011 · Bombdr DHC8400 · Buffet/GalleysSDR CA110930006Actuator · stuck(CAN) DURING CLIMB NR 2 OIL TEMP INCREASED TO 109C. MX FOUND THE ACOC DOOR ACTUATOR STUCK CLOSED. REPLACED ACTUATOR.Sep 21, 2011 · Bombdr DHC8400 · Engine Oil Distribution (Airframe Furnished)SDR CA110922002Windshield · cracked(CAN) RIGHT SIDE WINDSHIELD SHATTERED, QRH ACTION ABOUT 16,000 FT, NO DECOMPRESSION, NORMAL LANDING ACCOMPLISHED. INNER PANE AND OUTER PANE FOUND INTACT. MIDDLE PANE FOUND CRACKED. NO DECOMPRESSION HAPPENED. WINDSHIELD NEEDS TO BE REPLACED.Sep 18, 2011 · Bombdr DHC8400 · Flight Compartment WindowsSDR CA110928008Engine · making metal(CAN) AFTER T/O, CLIMBING AND PASSING FL90, THE PILOT NOTICED A LOW OIL PRESSURE INDICATOR ON AND CAS MESSAGE. HE ELECTED TO SHUT THE ENGINE DOWN. AN UNEVENTFUL SINGLE ENGINE LANDING WAS THEN MADE AT THE POINT OF DEPARTURE. POST FLIGHT INSPECTION REVEALED NOSep 15, 2011 · Bombdr DHC8400 · Engine (Turbine/Turboprop)SDR CA110930004Actuator · inoperative(CAN) NR 1 OIL TEMP TO 105 DURING CLIMB. STAYED AT 105 FOR ABOUT 7 MINUTES. DECREASED DURING DESCENT. MX REPLACED MOT SENSOR THEN DISCOVERED ACOC FLAP DOOR STUCK PARTIALLY CLOSED AFTER OPS CHECK. DOOR ACTUATOR REPLACED.Sep 14, 2011 · Bombdr DHC8400 · Engine Oil CoolerSDR CA111206007Switch · shorted(CAN) THE F/A RECEIVED AN ELECTRICAL SHOCK FROM THE RT COFFEEMAKER. THE COFFEEMAKER WAS REPLACED. PN 400-1794-02, SN 11-07-48811, ACFT TSN 853, CSN 580.Sep 14, 2011 · Bombdr DHC8400 · Buffet/GalleysSDR QXEA2011091600814Sill · corrodedFOUND CORROSION ON RT AFT SERVICE DOOR SILL PLATE. BLENDED CORROSION IAW SRM 51-21-00-02. BLENDED AREA IS A NO REPAIR ALLOWED AREA. ENGINEERING REQUEST SENT TO MFG. FABRICATED AFT SERVICE DOOR EDGE CHANNEL IAW SRM 51-24-35-02-01 AND 53-40-21-00-01. PERFORSep 13, 2011 · N400QX · Bombdr DHC8402 · Fuselage Miscellaneous StructureSDR CA111206005Switch · shorted(CAN) THE F/A RECEIVED AN ELECTRICAL SHOCK FROM THE LT COFFEEMAKER. THE COFFEEMAKER WAS REPLACED. PN 400-1794-02, SN 11-01-47902. ACFT TSN 845, CSN 574.Sep 13, 2011 · Bombdr DHC8400 · Buffet/GalleysSDR CA110914002Fuel Sys · malfunctioned(CAN) ON INITIAL POWER UP FOR T/O THE NR 2 ENGINE ONLY WENT TO 51 PERCENT TQ DESPITE BEING SET FOR AN 83 T/O POWER. THE CREW REJECTED TAKEOFF. THEY THEN DE-SELECTED REDUCED POWER TAKEOFF AND COMPLETED A STATIC RUN DURING WHICH THE ENGINE POWER WENT TO 85 PERCSep 6, 2011 · Dhav DHC8103 · Engine Fuel DistributionSDR CA110907001Flow Divider · failed(CAN) FLIGHT CREW REJECTED TAKEOFF TWICE AFTER THE NR 2 ENGINE DIDN`T ACHIEVE DESIRED TAKEOFF POWER. ON THE FIRST ATTEMPT THE ENGINE REACHED 51 PERCENT OF TORQUE AND ON THE NEXT 49 PERCENT. MX REPLACED THE FULL AUTHORITY DIGITAL ELECTRONIC CONTROL (FADEC) COSep 5, 2011 · Dhav DHC8103 · Engine Fuel DistributionSDR QXEA2011090600809Autofeather Sys · no testFAILED AUTOFEATHER TEST NR2 SIDE. INTERROGATED CDS, FOUND NR2 PROP FAULT CODES 434 (A AND B), AND 400 (B ONLY). C/W OP CHECK OF PROP FAULT INDICATION IAW FIM TASKS 61-20-10-810-826, FOR 494 (A AND B), AND 61-20-09-810-806, FOR 400 (B). C/W OPS TEST OF NR 2 PRSep 1, 2011 · N406QX · Bombdr DHC8402 · Propeller Feathering/ReversingSDR CA110930003Actuator · inoperative(CAN) NR 1 OIL TEMP SHOWED 111C WHEN LEVELED OFF AT 22,000. AFTER CONDUCTING ABNORMAL CHECK LIST, CONTACTING MX, AND REDUCING PWR, TEMP DECREASED TO 107C IN APPROX 1 MIN. MX REPLACED THE OIL COOLER FLAP ACTUATOR.Sep 1, 2011 · Bombdr DHC8400 · Engine Oil CoolerSDR QXEA2011090600800Skin · corrodedPANEL 261HT AFT MATING SURFACE HAS FRETTING. BLENDED DAMAGE AREAS IAW RD 8/4-53-521. FOUND TO BE WITHIN LIMITS OF RD 8/4-53-521. COMPLETED REPAIRS IAW RD 8/4-53-521.Aug 30, 2011 · N427QX · Bombdr DHC8402 · Fuselage Main, Plate/SkinSDR CA110825002Control Valve · failed(CAN) FLIGHT WAS TURNED BACK DUE TO BLEED HOT AND CABIN PRESSURE WARNING. ACFT WAS INSPECTED BY MX FOUND A PROBLEM WITH THE PFCV WHICH WAS CORRECTED. A FUNCTIONAL CHECK WAS CARRIED OUT AND NO ADDITIONAL FAULTS FOUND, THEREFORE, ACFT WAS RETURNED TO SERVICE.Aug 24, 2011 · Bombdr DHC8400 · Cabin Cooling SystemSDR CA110830001Engine · failed(CAN) DURING REVENUE FLIGHT, THE CREW ABORTED TAKEOFF RUN AFTER HEARING LOUD NOISE FROM THE RT ENGINE. BORESCOPE INSPECTION SHOWED HP BLADES IN BAD CONDITION. ENGINE IS BEING REPLACED.Aug 23, 2011 · Dhav DHC8103 · Engine (Turbine/Turboprop)SDR CA110824006Fuel Tank · contaminated(CAN) WHILE LEVELING OFF AT 9000 FT, AFTER FLIGHT IDLE DECENT, NT 2 ENGINE POWER ADVANCED TO 30 PERCENT TORQUE, CREW RECEIVED A FUEL PRESS CAUTION LIGHT TEMPORARY, MOMENTARY TORQUE SURGE AND RETURNED TO NORMAL, HAPPENED AGAIN WHEN LEVELING OFF AT 6000 FT ON SAAug 21, 2011 · Bombdr DHC8400 · Fuel StorageSDR CA110822009Coffeemaker · shorted(CAN) IN CRUISE, THE F/A RECEIVED A LIGHT ELECTRICAL SHOCK WHEN ATTEMPTING TO TURN THE LT COFFEEMAKER ON. CREW REPORTED THAT THE ON/OFF SWITCH WAS COVERED WITH STEAM. THE LT COFFEEMAKER HAS BEEN DEFERRED IAW MEL 25-20-01 CATEGORY AND THE ACFT RETURNED INTO SAug 20, 2011 · Dhav DHC8102 · Buffet/GalleysSDR CA111206004Coffeemaker · shorted(CAN) THE F/A RECEIVED AN ELECTRICAL SHOCK FROM THE LT COFFEEMAKER. THE COFFEEMAKER WAS REPLACED. PN 400-1794-02, SN NOT RECORDED. ACFT TSN 500, CSN 336.Aug 20, 2011 · Bombdr DHC8400 · Buffet/GalleysSDR CA110817006Generator · failed(CAN) ON DEPARTURE, NR 2 AC GENERATOR WENT OFF LINE - AFTER CREW ATTEMPTED TO RECTIFY PROBLEM, GENERATOR COULD NOT BE RESET. ACFT RETURNED TO DEPARTURE. AT ARRIVAL, MX TOOK OVER ACFT WHERE NR 2 AC GEN WAS REPLACED. ACFT WAS PUT BACK TO SERVICE.Aug 16, 2011 · Dhav DHC8103 · AC Generator-AlternatorSDR CA110920007Bypass Valve · malfunctioned(CAN) NR 1 ENGINE OIL TEMP AT 115C AT FL 150 TEMP STAYED AT 115 FOR 15 MINUTES. STARTED TO COOL DURING DESCENT. MX REPLACED THE ACOC THERMAL BYPASS VALVE.Aug 16, 2011 · Bombdr DHC8400 · Turbine Engine Oil SystemSDR NSVA2011178Valve · defectiveAT FL110 CREW HAD THE FADEC FAULT LIGHT ILLUMINATE. THEN ENGINES WERE INDICATING NORMAL. CREW FOLLOWED QRH AND CONTINUED TO ALB. DECLARED AN EMERGENCY FOR PRIORITY HANDLING AND LANDED WITHOUT ISSUES. CHANGED NR 1 P2.7 VALVE AND EXITER BOX. OPS CHECKED GOOAug 14, 2011 · N339NG · Bombdr DHC8402 · Fuel Controlling SystemSDR CA110920008Generator · faulted(CAN) NR 1 AC GENERATOR" CAUTION LIGHT. MX FOUND FAULT CODE 27 IN EPCU. R & R NR 1 AC GENERATOR. OPS TEST GOOD.Aug 11, 2011 · Bombdr DHC8400 · AC Generator-Alternator
Back to Pratt & Whitney Canada PW150A