Pratt & Whitney PT6 series
Service difficulty reports · 884
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PT6' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PT6' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2004FA0000735Wheel · crackedINNER WHEEL HALF OF WHEEL ASSEMBLY PN 40-170A, SN 10, HEAT LOT NR 283 WAS REJECTED DURING EDDY CURRENT INSPECTION FOR CRACKS IN EXCESS OF 0.010 INCH. INDICATIONS WERE FOUND IN THE AREA OF BEAD SEAT OF THE INNER HALF OF THE WHEEL ASSEMBLY ONLY, NO INDICATIONS SDR A2B2004F00000Motor · failedDURING OPERATION SMOKE WAS NOTICED IN THE COCKPIT AND A PRCAUTIONARY LANDING WAS MADE. MAINTENANCE FOUND THE FORWARD EVAPORATOR BLOWER MOTOR, WHEN OPERATED ON HIGH, BEGAN TO SLOW AND SMOKE AFTER APPROXIMATELY 15 MINUTES. SUSPECTED THAT THE PROBLEM WAS IN THESDR 2004FA0000796Bolt · looseINSPECTION AFTER TURBULENT AIR, DISCOVERED BOTH UPPER FWD WING BOLTS AND NUTS WERE ONLY INSTALLED HAND TIGHT. REVEALED THAT WING BOLT INSP HAD BEEN COMPLETED 116.8 HOURS BEFORE. WING BOLT RETORQUE CHECK HAD BEEN COMPLIED WITH 72.8 HOURS AFTER THAT. AIRCRAFTSDR 2004FA0000628Float Switch · failedOWNER COMPLAINED RT FUEL PUMP WAS INOPERATIVE. TROUBLESHOOT SYSTEM TO A HEAVY FUEL FLOAT SWITCH P/N 602-501. HEAVY FLOAT CAUSED FUEL PUMP TO BE INOPERABLE WHEN SELECTED IN MANUAL OR AUTOMATIC.SDR 2004FA0000748Mount · damagedAT 25 HR INSPECTION, MECH HEARD A RATTLING NOISE WHEN INSPECTING NIGHTSUN II. LENS WAS REMOVED, REFLECTION WAS REMOVED. FOUND BOTH MOUNTING PLATES (PN032452, PN 032470) REV X1 BROKEN COMPLETELY OFF AT REFLECTOR BUT STILL SCREWED TO MOUNT. ALSO, BULB SET SCRSDR 63594Fire Detector · malfunctionedON TAKEOFF ROLL OUT, FLIGHT CREW OBSERVED LT ENGINE FIRE BOTTLE DISCHARGED ANNUN. ILLUMINATED. CREW ABORTED TAKE OFF AND RETURNED TO THE GATE WITH NO FURTHER INCIDENT. THE BOTTLE WAS SAID THAT IT WAS NOT DISCHARGED. REMOVED AND REPLACED 173 PC BOARD FIRE DETSDR HYTA2004007Spar · chafedLOWER SURFACE OF LT AND RT FORWARD WING SPARS AND LIFT STRUT ATTACH FITTINGS HAVE BEEN CHAFED BECAUSE OF CONTACT WITH THE LIFT STRUT UPPER FAIRING/COVER. WORST DAMAGE WAS LESS THEN .005 INCH IN DEPTH AND WAS EASILY BLENDED OUT. APPLIED VINYL CHAFE TAPE TO SPSDR 63455Uplock Switch · failedAFTER TAKEOFF WHEN GEAR WAS RETRACTED THE LANDING GEAR IN-TRANSIT LIGHT REMAINED ILLUMINATED. CREW CONTACTED DISPATCH AND MAINTENANCE CONTROL. CREW WAS TOLD TO DIVERT. AIRCRAFT THEN DIVERTED, LANDED WITH NO FURTHER INCIDENTS. REMOVED AND REPLACED RT UPLOCK SDR 63428Brake Assy · malfunctionedWHILE TAXING IN AFTER LANDING IN TPA. CAPTAIN FELT THAT THE LT BRAKE FELT SPONGY. THEN CALLED MAINTENANCE. BRAKES WAS BLEED, OPS CK NORMAL.SDR HPF2004F00001Motor · failedMOTOR MOUNT STUDS PULLED OUT ENABLING FAN TO JAM. MOTOR OVERHEATED AND PRODUCED ELECTRICAL SMOKE IN CABIN. CIRCUIT BREAKER FINALLY POPPED. PROBABLE CAUSE WAS EITHER OVERTORQUE OF MOTOR ATTACH NUTS OR DEFECTIVE CASE ON EVAPORATOR ASSEMBLY. THIS WAS AN ORIGISDR 63383Brake · lowRECEIVED CALL FROM CREW ABOUT BRAKES FEELING SPONGY. CALLED PIT MAINTENANCE. BLEED LT AND RT BRAKES. SERVICED BRAKE HYDRAULIC RESERVIOR LEAK CK GOOD.SDR 63379Hydraulic System · lowRECEIVED CALL FROM CAPTAIN HIS LT BRAKE WAS BLEEDING OFF. THEN CALLED MAINTENANCE IN PIT. BLEED LT BRAKE AND SERVICED HYDRAULIC BRAKE GROUND CK GOOD. LEAK CK GOODSDR DJX2004F00000Solenoid · inoperativeDURING A RUDDER BOOST TEST THE RT RUDDER PEDAL, REMAINED AT FULL DEFLECTION EVEN WITH THE ENGINES AT IDLE. BY TURNING THE SYSTEM OFF BOTH PDEALS WOULD RETURN TO CENTER. IF THE SYSTEM FAILED ON FINAL AND OR DURING TAKE OFF THE END RESULT COULD BE DEVASTATING.SDR 63269Seal · blownWHILE AIRCRAFT WAS ENROUTE, FO'S STORM WINDOW SEAL BLEW OUT CAUSING AIRCRAFT TO DEPRESSURIZE. CREW DESENDED TO UNDER 10,000 AND CONTINUED WITH NO FURTHER INCIDENT. RESECURED BOTTOM OF SEAL ON FO'S STORM WINDOWSDR IJAA016FDownlock Switch · dirtyRT MAIN GEAR DOWN LIGHT WOULD NOT COME ON WHEN LANDING GEAR WAS DOWN AND LOCKED. AIRCRAFT WAS LANDED WITHOUT INCIDENT. IT WAS DETERMINED THAT THE LANDING GEAR DOWN LOCK SWITCH WAS DIRTY WITH PAINT OVERSPRAY AND THE GEAR WAS RIGGED TO MIN TRAVEL OF DOWN LOCK SDR GUU2004F00026Fire Loop · brokenAFTER TAKEOFF, FIRE LOOP ENUNCIATOR AND RT T-HANDLE ILLUMINATED. THE RT ENGINE WAS SHUT DOWN AND THE FIRE EXTINGUISHER WAS FIRED. DECLARED AN EMERGENCY RETURN TO FLL. INSPECTED RT ENGINE. NO EVIDENCE OF FIRE OR FLUID LEAKS FOUND. FORWARD FIRE LOOP BROKEN SDR 62683Valve · malfunctionedLANDING GEAR FAILED TO EXTEND ON FIRST ATTEMPT. GEAR FINALLY EXTENDED ON THE SECOND ATTEMPT. REMOVED AND REPLACED HYD SERVICE VALVE. OPS CK GOOD.SDR PNSA040604Hub · damagedSLUGGISH RESPONSE TO TAKEOFF POWER AND RPM/TORQUE DROPPED OFF AT FLIGHT IDLE POWER SETTINGS. AIRCRAFT MADE NORMAL LANDING WITH POWER LEVER FURTHER FORWARD THAN NORMAL. MAINTENANCE FOUND PROPELLER BLADE ANGLE IN HUB 2 DEGREES OFF AND BETA RING BENT. AT TEARDOWSDR GUU2004F00025Bracket · corrodedAT SCHEDULED ROUTINE MAINTENANCE, RT OB ELEVATOR HINGE BRACKET SHOWS SIGNS OF EXFOLIATION. REMOVED AND REPLACED RT OB ELEVATOR HINGE BRACKET.SDR 62587Control Handle · malfunctionedON APPROACH TO LANDING. THE FIRST AND SECOND ATTEMPTS TO EXTEND LANDING GEAR FAILED. CREW WIGGLED HANDLE AND GOT GEAR TO EXTEND WITH ALL GEAR INDICATING DOWN LOCK. LANDED SAFELY WITH NO FURTHER INCIDENT. REMOVED AND REPLACED LANDING GEAR HANDLE. OPS CK GOOD.SDR HEEA096491Window · separatedDURING APPROACH TO LAND, A PASSENGER LEANED AGAINST THE WINDOW ON THE RT SIDE SLIDING DOOR AND THE WINDOW RELEASED AND WAS LOST. AIRCRAFT LANDED WITH NO FURTHER OR OTHER DAMAGE AND NO INJURIES.SDR GLBA20030654Structure · corrodedCABIN DOOR CORROSION, REPAIRED DOOR.SDR GLBA20030646Odor · detectedSMELL OF ELECTRICAL SMOKE IN COCKPIT, INSPECTED A/C SYSTEMS, FOUND NO DEFECTS.SDR G1I2004F00000Clevis Pin · shearedDURING CLIMB OUT, THROUGH APPROX 1800 FEET EXPERIENCED RAPID LOSS OF CABIN PRESSURE. DESCENDED AND RETURNED TO DEPARTURE AIRPORT. AFTER EXTENSIVE TROUBLESHOOTING IT WAS DETERMINED THAT THE UPPER FORWARD LATCH HAD A BROKEN CLEVIS PIN AT THE LATCH PIVOT POINT.SDR 8343720Wire · brokenYAW DAMP RUDDER BOOST, ENGAGED ON ITS OWN. REPAIRED WIRE AT NR W13 AT PIN A ON LT ENGINE P5 CONNECTOR AND REPLACED YR5-65 SENSOR.SDR GUU2004F00023Bracket · corrodedAT SCHEDULED ROUTINE MAINTENANCE, RT OB ELEVATOR HINGE BRACKET SHOWS SIGNS OF EXFOLIATION. REMOVED AND REPLACED RT OB ELEVTOR HINGE BRACKET.SDR GUU2004F00024Fire Loop · intermittentDURING FLIGHT, RT FIRE LOOP ANNUNCIATOR ILLUMINATED INTERMITTNETLY. CONTINUED, LANDED WITHOUT INCIDENT. INSPECTED FORWARD AND AFT FIRE LOOP ASSEMBLY. CLEANED RT FIRE LOOP CONNECTORS. OPS CHECK NORMAL.SDR GUU2004F00020Controller · shortedDURING APPROACH, ODOR OF ELECTRICAL SMOKE WAS PRESENT IN THE COCKPIT, AND NR 1 NAVIGATION CONTROLLER WAS INOPERATIVE. REMOVED AND REPLACED NR 1 NAVIGATION CONTROLLER. OPERATIONAL CHECK NORMAL.SDR GUU2004F00016Bracket · corrodedAT SCHEDULED ROUTINE MAINTENANCE, LT OB ELEVATOR HINGE BRACKET SHOWS SIGNS OF EXFOLIATION. REMOVED AND REPLACED LT OB ELEVATOR HINGE BRACKET.SDR GUU2004F00017Bracket · corrodedAT SCHEDULED ROUTINE MAINTENANCE, LT OB ELEVATOR HINGE BRACKET SHOWS SIGNS OF EXFOLIATION. REMOVED AND REPLACED LT OB ELEVATOR HINGE BRACKET.SDR GUU2004F00019Hose · looseDURING FLT, LT RED T HANDLE LIGHT ILLUMINATED. RESECURED LT ENGINE BLAST TUBE. OPERATIONAL CHECK NORMAL.SDR GLBA20030629Structure · corrodedCABIN DOOR HAS CORRODED AREA BY BUTTON, REPAIRED.SDR GUU2004F00015Brake Assy · wornDURING TAXI, RT SIDE BRAKING ACTION NOT ADEQUATE. REMOVED AND REPLACED NR 3 BRAKE ASSEMBLY. BLED BRAKES. OPERATIONAL CHECK NORMAL.SDR GUU2004F00021Bracket · corrodedAT SCHEDULED ROUTINE MAINTENANCE, RT CENTER ELEVATOR HINGE BRACKET SHOWS SIGNS OF EXFOLIATION. REMOVED AND REPLACED RT CENTER ELEVATOR HINGE BRACKET.SDR GUU2004F00022Bracket · corrodedAT SCHEDULED ROUTINE MAINTENANCE, RT OB ELEVATOR HINGE BRACKET SHOWS SIGNS OF EXFOLIATION. REMOVED AND REPLACED RT OB ELEVATOR HINGE BRACKET.SDR UNI2004F00000Flap Track · corrodedUPON PERFORMANCE OF INSPECTION OPERATION MD OF MFG MM, SEVERE EXFOLIATION, CORROSION WAS FOUND ON BOTH OB FLAP TRACKS. AREAS ON FLAP TRACK WHERE CORROSION WAS DISCOVERED INCLUDE: AFT RECESSED WEB AREA AND ADJACENT UPPER AND LOWER PORTIONS OF TRACK. CONTRIBUSDR HEEA096022Power Supply · burnedDURING FLIGHT THERE WAS A BURNING ODOR IN COCKPIT AND CIRCUIT BREAKER POPPED. MAINTENANCE FOUND THE INSTRUMENT LIGHTS POWER SUPPLY HAD BURNED. REPLACED BURNED INSTRUMENT LIGHTS POWER SUPPLY.SDR HEEA096023Pump · failedDURING FLIGHT THE NR 1 BOOST PUMP FAILED. MAINTENANCE REPLACED THE NR 1 BOOST PUMP.SDR GUU2004F00006Hinge Bracket · corrodedAT SCHEDULED ROUTINE MAINTENANCE, TR OB ELEVATOR HINGE BRACKET SHOWS SIGNS OF EXFOLIATION. REMOVED AND REPLACED RT OB ELEVATOR HINGE BRACKET.SDR LX52004F00000Indicator · inoperativeTHE NR 2 HYDRAULIC SYS RETURN FILTER BYPASS INDICATOR WAS FOUND EXTENDED (POPPED) ON PREFLIGHT CHECK. WHEN WE REMOVED THE FILTER TO CHANGE IT, A SMALL PIN WAS FOUND IN THE FILTER BOWL. UPON FURTHER INVESTIGATION, A HOLE WAS FOUND ON THE SIDE OF THE BYPASS INSDR GUU2004F00005Warning Light · intermittentDURING FLIGHT, LT FIREWALL FUEL VALVE LIGHT FLICKERED. INSPECTED LT FIREWALL SYSTEM. NO DEFECTS NOTED.SDR GUU2004F00004Line · contaminatedDURING TAXI, VERY POOR BRAKING ACTION ON RT PEDAL. BLED RT BRAKE SYSTEM. OPS CHECK NORMAL.SDR 2004F00102Strap · brokenMAIN ROTOR BONDING STRAP BROKEN. THIS IS A CONSTANT PROBLEM, PORTION OF THE STRAP WHICH CONTINUES TO BREAK IS MADE OF COPPER. THIS END OF THE STRAP BOLTS TO A STAINLESS STEEL CONNECTION WHICH NEVER BREAKS. THE ENDS OF THE BONDING STRAPS SHOULD BE MADE OF A SDR HYTA2004006Longeron · crackedLT LONGERON 261310531 AND RT LONGERON 261310528 WERE FOUND CRACKED AT THE LOWER AFTER CORNERS OF THE CUT-OUTS FOR THE CONTROL COLUMN TORQUE TUBE. THESE CUT-OUTS ARE LOCATED JUST FORWARD OF THE NOSE GEAR SPRING SUPPORT FITTINGS 26430633. RT LONGERON HAS ONE CSDR FCPR200400013Brake Assy · crackedTORQUE PLATE BROKE WHEN APPLYING BRAKES, APPEARS THAT CRACK STARTED UNDER BUSHING THAT CARRIES THE CALIPER PINS, DOES NOT HAVE A PROCEDURE TO REMOVE BUSHINGS TO CHECK FOR CRACKS.SDR GUU2004F00003Circuit Board · shortedDURING FLIGHT, SMELLED ELECTRICAL ODOR IN COCKPIT. SELECTED LT BLEED AIR ENVIRONMENTAL OFF. CONTINUED TO NAS. LANDED WITHOUT INCIDENT. MAINTENANCE FERRY. REPAIRED CHAFFED WIRE FROM PRESSURE REGULATOR PIN F. REMOVED AND REPLACED BLEED AIR PC BOARD A317. SDR DAT2004F00002Control Valve · failedTHE BRAKES WENT OUT ON THE GROUND. THE FLIGHT CREW LOST CONTROL AND HIT ANOTHER AIRCRAFT. THE RIGHT WING TIP HIT THE RT VERTICAL STABILIZER ON OTHER AC. MECHANICS WERE DISPATCHED, THE RT WING TIP WAS REMOVED AND REPLACED. THE BRAKE CONTROL VALVE WAS ALSO RSDR GW12004F00001Arm · fracturedLEFT MLG RETRACT ARM, PN 42042002, WHICH ATTACHES THE ACTUATOR TO THE FORWARD SIDE BRACE FAILED DURING RETRACTION OF THE LANDING GEAR AFTER TAKE OFF. PILOT STATED THAT AFTER A NORMAL TAKE OFF HE ATTEMPTED TO RETRACT THE LANDING GEAR THE LEFT MAIN FAILED TO RESDR EVT2004F00000Pin · brokenFRONT AIRSTAIR TOP HOOK FOUND LOOSE WHEN OPENED. ON INSPECTION FOUND PIN BROKEN. HOOK REPLACEMENT AND INSPECTION. NOT DUE UNTIL 10,000 HOUR.SDR FTU2004F00001Torque Knee · gougedDURING A 6 YEAR/ 8,000 CYCLE LANDING GEAR INSPECTION, DAMAGE WAS FOUND ON ALL 4 MAIN LANDING TORQUE KNEE`S AT THE UPPER (PN 101-8100321) AND LOWER (PN1018100327) KNEE`S ATTACH POINT. ITS SUSPECTED THAT IN THE PAST, SOMEONE HAD ATTACHED SOME KIND OF HOOK CLAMP
Back to Pratt & Whitney PT6 series