SDR 2004FA0000350Line · separatedPILOT EXPERIENCED AN ALTITUDE PORPOISE WITH AUTOPILOT ENGAGED. AIRSPEED IND INDICATED THAT AIRSPEED WAS DECREASING, ALTHOUGH AIRSPEED REMAINED SAME. BOTH PITOT SYS WERE CHECKED, OK. RT STATIC SYS WAS CHECKED, FOUND TO BE OK. THE LT STATIC SYS WOULD NOT PRESSDR FCPR200400012Shutoff Valve · stuckDURING TRAINING, PILOT CLOSED THE RT FIREWALL SHUTOFF VALVE AND WAS UNABLE TO OPEN IT. VALVE STUCK IN CLOSED POSITION. REPLACED VALVE, SYSTEM FUNCTION CHECK WAS NORMAL. (NM09200408137)SDR 2004FA0000527Fitting · corrodedDURING A PHASE 2 AIRFRAME INSPECTION, EXFOLIATION CORROSION WAS FOUND ON THE HORIZONTAL STABILIZER UPPER ATTACH FITTING IN TWO PLACES. ALSO EXFOLIATION CORROSION WAS FOUND ON THE RT UPPER SPAR CAP OF THE HORIZONTAL STABALIZER. BOTH ARTICLES ARE BEING REPLACESDR GUU2004F00014Bracket · corrodedAT SCHEDULED ROUTINE MAINTENANCE, RT CENTER ELEVATOR HINGE BRACKET SHOWS SIGNS OF EXFOLIATION. REMOVED AND REPLACED RT CENTER ELEVATOR HINGE BACKET.SDR HYTA2004003Bolt · corrodedWHILE CONDUCTING INITIAL INSPECTION, BOTH AFT WING TO FUSELAGE ATTACH BOLTS WERE FOUND SLIGHTLY RUSTED. DAMAGE WAS NEGLIGIBLE. THESE BOLTS AS WELL AS FORWARD ATTACH BOLTS AND UPPER AND LOWER STRUT ATTACH BOLTS WERE APPARENTLY INSTALLED DRY. THIS HARDWARE SHSDR HYTA2004004Wire · misroutedFLASHING BEACON WIRE IN TAILCONE WAS ROUTED OVER THE BALLAST RESISTOR WHERE THERE IS LESS THAN .5 INCH CLEARANCE TO STRUCTURE. WIRE WAS NOT TOUCHING BALLAST RESISTOR OR AIRPLANE STRUCTURE, BUT INSULATION WAS BURNED CLEAR THROUGH TO BARE WIRE. WIRE SHOULD HAVSDR HYTA2004005Spring · wornFLEXING OF MLG CENTER SPRING PN 2641014-3 CAUSES CENTER SPRING TO CONTACT MLG COVER PN 2611103-10 WHICH IS LOCATED BENEATH THE CENTER SPRING. CHAFING HAD WORN THROUGH THE PAINT ON THE LOWER SURFACE OF CENTER SPRING. TWO RIVETS HAD WORN INTO THE LOWER SURFACESDR E812004F00004Skin Panel · damagedNOTED LOOSE/DAMAGED RIVETS ATTACHING LT WING CENTER SECTION UPPER LEADING EDGE SKIN PANEL. UPON REMOVAL FOR SKIN PANEL REPLACEMENT, NOTED PANEL ATTACHED IN SEVERAL PLACES WITH MS20426AD TYPE RIVETS WHERE NAS1097 RIVETS ATTACHED ORIGINALLY. SKIN RIVET ATTACH SDR 8570000Gear · slippedWHILE CHECKING ELEVATOR TRIM FOR FCD BE2703 DISCOVERED ELEVATOR TAB DIAL MECHANISM MOUNT ASSY HAD SLIPPED CAUSING THE TRIM INDEX MARK CALIBRATION TO CHANGE. UPON FURTHER INSPECTION IT WAS DISCOVERED THAT THE SLIPPAGE WAS CAUSED BY A PRESSED ON GEAR IN THE ELEVSDR 4007053Rudder Pedal · looseTHE RUDDER PEDAL FOOT ASSEMBLIES ARE MADE UP OF A FOOT PEDAL WHICH SLIPS INTO A TUBE AND RIVETED TOGETHER WITH 6 BLIND RIVETS. (FOOT PEDAL IS OFFSET FROM THE TUBE, SO THE PEDAL WANTS TO ROTATE IN THE TUBE WHEN PUSHING FORWARD ON THE PEDAL) THE RIVETS WERE LOOSDR 2004FA0000274Drag Brace · corrodedTHE LOWER BOLT WAS SEVERELY CORRODED IN PLACE REQUIRING IT TO BE DRIVEN OUT FOR REPLACEMENT. THIS BOLT, CENTER DRAG BRACE ASSY PIVOT, IS LUBRICATED ON BOTH ENDS VIA THRU BOLT GREASE PROVISIONS. THE CENTER PORTION HAS NO PROVISION FOR GREASE SINCE THIS AREA ISDR E812004F00003Mount · crackedDURING ROUTINE INSPECTION FOUND ANGLE ON NOSE GEAR LOCK LINK UPPER HALF THAT NOSE GEAR DOWN AND LOCKED SWITCH S190 IS MOUNTED TO, CRACKED AT RADIUS APPROX .7500 WAY THROUGH. FURTHER INVESTIGATION SHOWED THAT REAR END OF SWITCH ASSY WHERE WIRING AND STRAIN RELSDR 2004F00083O-Ring · missingSMOKE ENTERED THE COCKPIT, (KEROSENE EXHAUST) DURING CLIMB. THE AIRCRAFT RETURNED. THE FORWARD HEATER WAS SLOW TO LIGHT OFF. DURING RECENT FUEL NOZZLE CLEANING, THE O-RING SEAL THAT SEALS THE NOZZLE TO COMBUSTION TUBE WAS NOT INSTALLED, OR FELL OUT DURING RSDR GLBA20030560Control Cable · frayedLT AILERON CABLE FRAYED BETWEEN WS 124.58 AND 147.74 (LT WHEEL WELL), REMOVED AND REPLACED LT AILERON WING CABLE. OPS CK AND RIG CK GOOD.SDR GLBA20030551Annunciator · false activationCABIN DOOR ANNUNCIATOR CAME ON IN FLIGHT, CABIN DOOR ANNUNCIATOR OPS CK GOOD.SDR GLBA20030550Control Cable · inoperativeMANUAL TRIM INOPERATIVE, REMOVED AND REPLACED FWD ELEVATOR TRIM CABLE PN 114-524037-25. OPS CK GOOD.SDR GLBA20030546Windshield · crackedFO'S WINDSHIELD CRACKED, R & R WINDSHIELD RT PN 129-5025-2SDR 58290Indicator · stuckON TAKEOFF ROLL THE LT PROP INDICATOR BEGAN TO READ HIGH, IT THEN WENT TO 2000 AND STUCK. CREW ABORTED TAKEOFF AND RETURNED TO GATE, ON SHUT DOWN INDICATOR STUCK AT 600. THERE WAS NO FURTHER INCIDENT OCCUR. COULD NOT DUPLICATE THE PROBLEM.SDR BAQA092610Brushes · wornMOTOR DELAYS, BRUSHES PROBABLY WORN OUT, SOUNDS WEAK. REPLACED WITH SERVICABLE UNIT. 02/13/2004SDR HPF2004F00000Hinge Pin · looseNOSE GEAR DOOR FORWARD HINGE PIN MIGRATED AFT, NOT PROPERLY RETAINED. SUGGEST DRILLING HINGE TO ENABLE SAFETY WIRE OR COTTER PIN TO PREVENT HINGE PIN MIGRATION. LOSS OF HINGE PIN WOULD RESULT IN SIGNIFICANT DAMAGE TO NOSE GEAR DOOR.SDR 58159Fuel Control · leakingCREW REPORTED FUEL LEAK LT NACELLE. REMOVED AND REPLACED LT FCU HIGH PRESSURE FUEL TUBE WHICH ATTACHES AFT SIDE OF FUEL FLOW TRANSMITTER. OPS CK NORMAL P/N 3032791.SDR XVQ2004F00000Chain · misroutedLANDING GEAR WOULD NOT EXTEND WHEN LANDING HANDLE SELECTED FOR DOWN. PILOT SUCCESSFULLY EXTENDED GEAR RECEIVING THREE DOWN AND LOCKED INDICATION. UNEVENTFUL LANDING PERFORMED. INSPECTION OF SYSTEM REVEALED THAT THE NLG RETRACT CHAIN WAS IMPROPERLY ROUTED OVSDR 2004F00259Washer · out of positionRT WING CENTER SECTION MAIN SPAR UPPER FITTING HAS A DEPRESSION, DUE TO THE WASHER NOT PROPERLY IN PLACE. DEPRESSION BLENDED TO A SMOOTH PROFILE WITH A .125 FINISH, ALL WORK DONE IAW FIELD REPAIR FR-KA-01188, REV A. (M)SDR DFZ2004F00000Spline Adapter · brokenRT ENGINE WENT TO FULL POWER IN THE AIR. INSPECTED, FOUND COUPLING SPLINE (PLASTIC) BETWEEN FCU AND FUEL PUMP, BROKEN. REMOVED AND INSTALLED OH FCU AND FUEL PUMP.SDR JRP2004F00000Fitting · crackedLATERAL CRACK BETWEEN RIVETS IN VERTICAL LEG OF FITTING AT WS 40 AND AT WS 47.5 FITTING IS PART OF FORWARD WING ATTACHMENT ASSEMBLY. NOTE: PART NAME IS FRONT SPAR CAP ADAPTOR FITTING.SDR DWH2004F00000Wire Harness · brokenPILOT REPORTED LT MLG DOWN AND LOCKED INDICATOR WAS NOT ILLUMINATED AFTER LANDING GEAR EXTENSION AND DECLARED AN EMERGENCY. THE AIRCRAFT WAS LANDED ANT VNY WITHOUT INCIDENT. UPON INVESTIGATION, A TY-WRAP WAS MISSING FROM THE LT MLG DRAG ACTUATING ROLLER HAD SDR 57206Brake · malfunctionedAFTER LANDING IN PIT. CREW REPORTED THAT THE LT BRAKE HAD VERY LITTLE PRESSURE ON TAXI. BLEED LT BRAKES SYS. IAW MM 32-40-00. OPS AND LEAK CK GOOD.SDR 2003FA0001247Angle · damagedTWO ANGLES THAT ARE THE FORWARD MOUNTING STRUCTURE OF THE VERTICAL STABILIZER TO THE HORIZONTAL STABILIZER HAVE 2 HOLES EACH WITH BOLTS THAT ATTACH THE HORIZONTAL STAB., AND 5 HOLES EACH WITH 4 LOCKBOLTS INSTALLED THAT ATTACH TO THE VERTICAL STAB. THE TOP HOLESDR 8394094Bolt · bentDURING DETAIL NR 6 INSPECTION FOUND RUDDER CONTROL HORN MOUNT BOLT BENT AND TORQUE TUBE MOUNT BOLTS LOOSE.SDR 56696Latch · brokenUPON ARRIVAL CREW HAD DOOR WARNING ANNUNCIATOR. IT WOULD NOT EXTUNGUISH. MAINT WAS CALLED AND FOUND LATCH CABLE BROKEN. CABIN DOOR INOPERATIVE CAMS ON AFT SIDE WILL NOT CLOSE. REMOVED AND REPLACED AFT DOOR LATCH CABLE. P/N 129-514059-25SDR 2003FA0001264Bracket · gougedDURING SCHEDULED PHASE INSPECTION NOTED OB SIDE OF RT RUDDER BOOST BRACKET AT FS 303 GOUGED DEEPLY THROUGH BY ADJACENT CABLE AT AFT END. LOCATION JUST IB OF AFT FUSELAGE ACCESS DOOR. APPEARS BRACKET HAD BEEN INSTALLED INCORRECTLY AT MFG OR HAD SOMEHOW BECOMESDR GUU2004F00007Bracket · corrodedAT SCHEDULED ROUTINE MAINTENANCE, LT OB ELEVATOR HINGE BRACKET SHOWS SIGNS OF EXFOLIATION. REMOVED AND REPLACED LT OB ELEVATOR HINGE BRACKET.SDR GUU2004F00008Bracket · corrodedAT SCHEDULED ROUTINE MAINTENANCE, RT OB ELEVATOR HINGE BRACKET SHOWS SIGNS OF EXFOLIATION. REMOVED AND REPLACED RT OB ELEVATOR HINGE BRACKET.SDR 112003Battery · failedDURING A FUNCTION TEST OF THE ELT THE UNIT WOULD NOT TEST. ON INVESTIGATION WE FOUND THAT ONE OF THE BATTERIES WAS FAULTY WITH AN (OPEN) CONDITION. WE REPLACED ALL THE BATTERIES AND THE UNIT FUNCTION TESTED PROPERLY.SDR 2003FA0001204Pad · deterioratedREPORTED (AFT FUEL LOW) LIGHT ILLUMINATING WITH 300-400 LBS REMAINING ON GAUGE. (SHOULD BE 110 LBS). TROUBLESHOOTING REVEALED FLAPPER PAD (SEAL) WAS DETERIORATED TO THE CONSISTENCY OF A (GUMMY BEAR). AS FUEL IS MOVED INTO THE NR 5 (ENG FEED) TANK, BY MOTIVESDR WK92003F00000Bolt · shearedDURING CRUISE FLIGHT AT ATTITUDE, CABIN ALTITUDE BEGAN TO CLIMB AS CABIN PRESSURE WAS LOST. A NOISE WAS OBSERVED AT CABIN AIRSTAIR DOOR. FLIGHT WAS CONTINUED AT A LOWER ALTITUDE WHERE PRESSURIZATION WAS NOT REQUIRED. UPON REACHING DESTINATION, DOOR WAS DISASDR CA031120011Blade · failed(CAN) DAMAGE TO PT COMPONENTS IS SUBSTANTIAL AND MOST ARE CONSIDERED SCRAP. DAMAGE INCLUDES LG NR OF PT2 BLADES (3115863-01) FRACTURED AT BLADE ROOT AND AT PT SHAFT HSG ASSY WHICH HAS MNT FLANGE SEPARATED FROM MAIN BODY OF HSG. ALL COMPONENTS EXCEPT GB ARE SCSDR EHA2004F00005Relay · stuckRT WINDSCREN SHATTERED AT FL250. NO LOSS OF CABIN PRESSURE OCCURED. LANDED SAFELY WITHOUT INCIDENT. UPDATE TO PREVIOUS SDR DATED 11/11/03. UPON DISASSEMBLY AND TESTING, IT WAS DETERMINED THAT THE CAUSE OF THE INCIDENT WAS THE WINDSHIELD HEAT RELAY.SDR 2003FA0001265Drag Brace · crackedDURING ROUTINE EVENT, 2 INSPECTION IT WAS DISCOVERED THE NOSE LANDING GEAR UPPER RT SIDE DRAG BRACE RETRACTION LUG ATTACH POINT EXHIBITED A CRACK INDICATION. THE CRACK INDICATION WAS DISCOVERED USING (FPI). REMOVAL OF THE NLG UPPER RT SIDE DRAG BRACE IS RECOSDR 2003FA0001177Blower · defectivePILOT NOTIFIED MAINTENANCE FACILITY OF DEFECTIVE VENT BLOWER. INSPECTED AND FOUND VENT BLOWER SEIZED. REPLACED VENT BLOWER WITH OVERHAULED PART. SYSTEMS OPS CHECKED NORMAL. REPLACED CURRENT LIMITER ALSO. OVERHAUL TIME LIMIT OR MOTOR.(K)SDR CA031107016Eyebolt · cracked(CAN) DURING MPI INSPECTION OF THE HORIZONTAL STABILIZER STRUT ATTACH EYEBOLTS, A CRACK APPROXIMATELY .1875 INCH IN LENGTH WAS NOTED. ALL EYEBOLTS WILL BE REPLACED PRIOR TO THE AIRCRAFT BEING RETURNED TO SERVICE.SDR TIM2003F00002Fitting · crackedFITTING FOUND TO BE CRACKED DURING STRUCTURAL INSPECTION. (CNTRL NR 82)SDR GLBA2003143Circuit Board · failedNR 2 PROP FEATHERED ON LANDING APPROACH, REMOVED AND REPLACED PCB. OPS CK GOOD.SDR 2003FA0001190Line · failedPILOT REPORTED SMOKE IN CABIN IMMEDIATELY AFTER TAKEOFF. LANDED IMMEDIATELY AND FOUND FUEL DRAINING FROM LEFT ENGINE. FOUND SEVERED FUEL LINE JUST BEHIND FORWARD B-NUT FITTING. LINE FAILURE SEEMS TO BE A FATIGUE FRACTURE.SDR 55657Brake · weakCREW REPORTED BRAKES ON RT SIDE FELT SPONGY. MAINT. BLEED BRAKES AND FOUND NO LEAKS. OPS CK NORMALSDR 55631Brake · weakAFTER LANDING CAPT REPORTED BRAKES WEAK. MAINTENANCE BLED BRAKES. OPS CK NORMAL. (BLED BRAKES CAPT SIDE AND SERVICED RESERVOIR).SDR BJ82004F00000Motor · failedPILOT REPORT SMELLING SMOKE IN COCKPIT. LANDED SAFELY. UPON INVESTIGATION FOUND FWD EVAPORATOR MOTOR HAD A BURN SMELL. REPLACED, OPS CHS GOOD. NO CHAPTER 4 OR 5 TIME ITEMS OR EVAPORATOR BLOWER ASSY OR INSPECTION OF BRUSHES.SDR CGO2003F00009Line · crackedDURING SCHEDULED INSPECTION NOTED HYDRAULIC FLUID LEAK FROM HYDRAULIC LINE CONNECTING POWER BRAKE SYSTEM FILTER ASSY. TO SYSTEM ACCUMULATOR. FURTHER INVESTIGATION REVEALED TUBING TO BE CRACKED NEXT TO B NUT FITTING. POSSIBLE CAUSES MAY INCLUDE TUBING MISALISDR BAQA088981Actuator · failedGEAR ACTUATOR FAILED END PLAY INSPECTION. 1000 CYCLE/ 30 MONTH INSPECTION. REPLACED WITH SERVICEABLE UNIT.10/20/03SDR BAQA088982Actuator · failedMLG ACTUATOR FAILED END PLAY INSPECTION. 1000 CYCLE / 30 MONTH INSPECTION. REPLACED WITH SERVICEABLE UNIT. 10/20/03
Back to Pratt & Whitney PT6 series