Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011070703383Actuator · faultyL/G DISAGREE MSG, RTFL. PER CREW, HAD LG DISAGREE MSG WITH ASC LIGHT. HEARD THUMP NOISE WHEN GEAR HANDLE SELECTED OFF AND WHEN SELECTED BACK UP. MAINT TEXT: PSEU SHOWS FAULTS 65 AND 78 FAULTING THE NOSE GEAR LOCK SENSORS. PER SAMC REQUESTED, RPL'D NOSE GEARSDR UALA2011070703390Light · brokenEEL PATH LIGHTING INOP FROM ROWS 8 THRU ROWS 12. FLOOR EMERGENCY LIGHT STRIPE BROKEN IN REAR OF AISLE. MOST SECTIONS IN COACH DO NOT TEST. REPLACED LIGHT STRIP, LIGHTS CHECK GOOD.SDR UALA2011070603354Lever · damagedEXCESSIVE RUDDER TRIM NEEDED (4 UNITS) TO CNTR YOKE. SUSPECT RUDDER RATIO CHANGER. RUDDER IS OUT OF RIG. FOUND YAW DAMP SUMMING LEVER WITH SHEARED RIVETS. REPLACED YAW DAMPNER LEVER.SDR UALA2011070603339Floorbeam · corrodedCORROSION ON FLOORBEAM AT BS 365.25 RBL 0 - RBL 58 MAIN CABIN (N-R 2775N00239). MAJOR REPAIR ACCOMPLISHED: FABBED T-CHORD, STRAPS, ANGLES, SHIMS AND INTERCOSTALS. INSTALLED T-CHORD, ANGLES AND STRAPS STA 365, RBL 0 - RBL 58. INSTALLED INTERCOSTALS STA 345 SDR UALA2011070703358Wire · brokenAUTOPILOT & A-P DISC LIGHT ON, LINE THRU (HDG HLD, HDG SEL, LNAV LOC, B-CRS) ON EADI, & EICAS MSG 'AUTOPILOT DISC' DISPLAYED WITH 1 AUTOPILOT SYSTEM ENGAGED IN CMD. OPS NORMAL WITH (L OR C) A-P SYS SELCTED (1=L, 2=C ,3=R) CREW COMMENTS: WITH CAPT FLT DIR OFF SDR UALA2011070603340Floorbeam · corrodedFLOORBEAM AT STA 1660 HAS CORROSION APPROXIMATELY 12 INCHES LEFT AND RIGHT OF BL ON TOP SIDE. MAJOR REPAIR ACCOMPLISHED: RMV'D PREVIOUS REPAIR, FABBED AND INSTALLED T-CHORD, ANGLES AND STRAPS STA 1660, LBL 10 - RBL 02 PER SRM ON PEMCO NR 2808N00106.SDR UALA2011070603337Hydraulic Line · leakingEVIDENCE OF HYDRAULIC FLUID ON TAIL SECTION OF AIRCRAFT. AFT FUSELAGE TAIL CONE HAS FLUID SPRAYED (APPEARS TO BE OIL NOT HYD) PREDOMINANTLY ON RIGHT. ACCMP'D CLEANED RESIDUAL OIL. RAN APU, NO ACTIVE LEAKS NOTED. LEAKING LINE ID BY MIDS. P/N BACH8C06EE0274BSDR UALA2011070703359Rivet · wornARMREST - CONSOLE LOOSE (ROCKS) AT 39C. AISLE ARMREST RIVETS SHEARED. SECURED ARMREST IN STATIONARY NORMAL POSITION. SEATS 39A, B, C NOT TO BE OCCUPIED. PLACARD WITH BLUE 'DO NOT OCCUPY COVERS'. SEATS IN UPRIGHT STOW POSITION. SEATS DO NOT INTERFERE WITHSDR UALA2011070503310Fire Loop · defectiveL ENG FIRE LP 2 STATUS MSG ON TAXI IN. FOUND NR 4 FIRE LOOP ON LOOP 2 SIDE OPEN. LOOP IS LOCATED ON RT SIDE FAN COWL. REPLACED NR 4 FIRE LOOP ON LOOP 2. FIRE TEST OPS CHECK GOOD. EICAS MSG CLEARED.SDR UALA2011070503328Apu · faultyAPU STARTED AND RAN NORMALLY FOR 3 MINUTES THEN QUIT AGAIN. CHIP DET AND OIL FILTER CHECKS GOOD. REPLACED APU PER AMM.SDR UALA2011070503305Floorbeam · damagedFLOORBEAM AT BS 660 HAS TOOLING MARK AT RBL 37-41.5 (N-R 2775N00559). MAJOR REPAIR ACCOMPLISHED: FABBED AND INSTALLED SUPPORT BEAM, ANGLES AND STRAPS AT STA 660, RBL 35 - 51 PER SRM.SDR UALA2011070503306Floorbeam · corrodedCORROSION ON FLOORBEAM AT BS 1640 FROM LBL 5 -RBL 58. (N-R 775N00395) MAJOR REPAIR ACCOMPLISHED: REMOVED OLD REPAIR, FABBED AND INSTALLED T-CHORD AT STA 1640, LBL 5 - RBL 58 PER SRM ON PEMCO NR 2775N00395.SDR UALA2011070503275Module · faultySLAT LOCKOUT, RTFL. ACCOMPLISHED BITE TEST OF FSEU 1 HAS GROUND FAULT OF FLAP-SLAT DEPRESSURATION MODULE V10060. SUSPECT VALVE IS BAD. REPLACED FLAP SLAT DEPRESSURIZATION MODULE.SDR UALA2011070503279D-Ring · unsecureDOOR 1L SLIDE PACK D-RING NOT VISIBLE. SECURED D-RING AND SLIDE COVER.SDR UALA2011070503283Cover · crackedCABIN FLOOR EEL LIGHT COVER CRACKED AND BROKEN BTWEEN SEAT ROW 20-27. REPLACED DAMAGED COVER.SDR UALA2011070503284Battery Pack · dischargedCABIN FLOOR EEL LIGHT INOP SEAT ROW BETWEEN 20-27. REPLACED CHARGER AND BATTERY M10770 WORKED BUT ONLY TEMPORARILY. REPLACED BATTERY PACK M10770, CHECKS OK.SDR UALA2011070503326Radio · malfunctionedNR 2 VHF COMM PROBLEMS. COAX CABLE TDR TESTED, CONNECTOR D41731P SECURED AND NR 2 VHF SYSTEM TEST. FIRST OFFICER MINITEL JACK CHECKED GOOD.SDR UALA2011070503323Skin · dentedEXTERNAL FUSELAGE SKIN DENTED AT APPROX STA 602 AND STA 623, BETWEEN STR 15L-16L, DENTS ARE WITHIN LIMITS OF SRM 53-00-01 AND FOUND TO BE CRACK FREE BY HFEC. OK TO ARCHIVE.SDR UALA2011070503325Shutoff Valve · faultyDURING TAXI, NR 2 ENGINE BLEED WOULD NOT OPEN UP WITH DEMAND. BOOSTED ENGINE, NO HELP. NO LOW STAGE EITHER. REPLACED HIGH STAGE PILOT IN REFERENCE TO MM, NO HELP. REPLACED HPRSOV WHICH HELPED, IN REFERENCE TO MM. NO LEAKS NOTED.SDR UALA2011070503288Strip · buckledEXIT FLOOR PATH STRIP BUCKLED AT 12C. SECURED STRIP.SDR UALA2011070503324Windshield · faultyR1 WINDSHIELD EXTREMELY COLD IN FLT COMPARED TO OTHER WINDSHIELDS. NO OTHER FAULTS NOTED. REPLACED WINDSHIELD. ACCOMPLISHED, 1ST TORQUE AT 02 JULY 2011, 0830.SDR UALA2011070103259Floorbeam · corrodedCORROSION ON LOWER PART FLOORBEAM AT BS 345 RBL 58 RBL 12 (N-R 2775N00237). MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED STA 345 FLOORBEAM RBL 8 - RBL 60 USING BAC 1505-100880 7075-T6 IAW B757 SRM. REPAIR ANGLES FROM PO 1061690. INSTALLED REPAIR PER B75SDR UALA2011070103267Fan · inoperativeCOOLING FAN IN THE RACK FOR RADAR TR UNIT INOP. REPLACED FAN.SDR UALA2011070103268Transceiver · faultyWX FAIL RD BOTH ND'S SHORT FINAL APPROACH. REPLACED TRANSCEIVER.SDR UALA2011070103249Light · inoperativeEMERGENCY GROUND ILLUM LIGHT AT DOOR 4L WILL NOT ILLUMINATE. RELAMPED, CHECKS OKAY.SDR UALA2011070103257Light · inoperativeEMERGENCY GROUND ILLUM LIGHT AT 2R WILL NOT ILLUMINATE. SEE PTT 6242015 FOR PARTS NEEDED. NEED SOCKET AND REFLECTOR OR LIGHT ASSY. N-S PN 30-2041-3, (LIGHT ASSY), 31-4964 -5 (SOCKET), 31-5506-1 (REFLECTOR). SECURED AND CLEANED LIGHT ASSY CONTACTS, OPS CHECSDR UALA2011070503276Mechanism · out of adjustAFT RT MAIN ENTRY DOOR SLIDE ARMED INDICATOR LIGHT DOES NOT ILLUMINATE WITH SLIDE ARMED. ADJUSTED RIGHT AFT DOOR GIRT BAR MECHANISM PER AMM, OPS NORMAL.SDR UALA2011070503277Line · out of positionWITH DOOR OPEN 3R SHOWS LINES-STRINGS HANGING OUT OF SLIDE PACK. REMOVED SHROUD. SECURE STRING. INSTALLED SHROUD. ARMED AND DISARMED DOOR. SATISFACTORY OPERATIONS.SDR UALA2011070503319Oxygen System · low pressureCREW REPORT: OXYGEN CREW NEEDS SERVICING. SERVICED CREW O2 PER AMM.SDR UALA2011063003224O-Ring · leakingFUEL & OIL LOSS, FLIGHT DIVERTED. ON RIGHT SIDE AS TOTALIZED AND CALCULATED FUEL WAS OFF BY APPROX 5000LBS. REPLACED O-RINGS AT FUEL PUMP TO FUEL CONTROL AND REPLACED CARBON SEAL AT FUEL PUMP.SDR FDEA201106292483Engine · erraticAT CRUISE FL 400, THE RT ENGINE BECAME ERRATIC WITH EPR FLUCTUATIONS BETWEEN 1.10 TO 1.29 WITH ASSOCIATED VARIATIONS IN N1 AND FUEL FLOW. TURNED AUTO THROTTLES OFF AND THE PROBLEM CONTINUED. REDUCING POWER DID NOT HELP. R & R RT(NR 2) ENGINE EEC IAW AMM 7SDR UALA2011062903204Oxygen Mask · missingOXYGEN MASK MISSING ON ONE OXYGEN BOTTLE IN AFT CABIN. REPLACED MASK.SDR UALA2011062903218Strap · brokenON POST FLT WALK AROUND SCRATCHES ON SIDE OF FUSELAGE LEFT SIDE 10' FWD OF DOOR 2L AT FLOOR LEVEL. ALSO IN NLG TUNNEL FOUND 2 FLOORBEAM STRAPS BROKEN BEAM 365-25 & 377.7. BLENDED SCRATCHES.SDR UALA2011062903210Sensor · faultedENGINE DUCT PRESSURES SPLIT DURING TAKEOFF OR CLIMB. ISOLATION VALVE CLOSED & BLEED SWITCH SELECTED ON. RECORDED DUCT PRESSURES. LEFT-42 RIGHT-36. REPLACED OVERTEMP STRUT BLEED SENSOR PER MM. OPS CHECKED GOOD.SDR UALA2011070103269Transceiver · faultyWX RADAR SHOWS A LOT OF GROUND RETURN UPPER 1-3 OF SCREEN 160NM RANGE FL390 MIDDLE OF SCREEN. REPLACED WEATHER RADAR TR UNIT IAW AMM, CKS OKAY.SDR UALA2011070103271Cover · missingFWD LT OVERWING FLOOR EMERGENCY LIGHTING MISSING ORANGE OVERLAY. INSTALLED ORANGE OVERLAY IN EMERGENCY LIGHTING ON FWD LT FLOOR IAW B757 AMM.SDR UALA2011070103273Support Bracket · crackedFOUND CRACKED HYD SUPPORT BRACKET AT NAC STA 180.8. REPLACED DAMAGED HYD SUPPORT BRACKET PER MM.SDR UALA2011062903205Skin · dentedSKIN DENT AT BS 430 AT S-17L. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED AREA AND INSTALLED A .063 INCH DOUBLER IAW SRM. IDENTIFIED REPAIR IAW GNMM.SDR UALA2011062903206Skin · corrodedCORROSION AT BS 1681-1691 AT RBL. FABRICATED DOUBLER IAW SRM AND PWIT1422. TREATED AND PRIMED DOUBLER PER SRM AND RESTORED FINISH IAW AMM.SDR UALA2011062703152Wire · looseAFTER ENG START NOTICED MESSAGE SAYING LEFT ENG 655 DEGREE OVERTEMP. FOUND SEVERAL CONNECTOR NUTS AT TERMINAL BLOCK APPROX 1 FULL TURN LOOSE. RETORQUED AS AND ACCOMPLISHED RESISTANCE CHECK OF EACH THERMOCOUPLE. ALL CHECKED OK. ALL ENG STARTS NORMAL.SDR UALA2011062703160Lamp · inoperativeDOOR 2L AND AFT LT OFF WING EMERGENCY EXIT EXTERIOR LIGHTS INOPERATIVE. REPLACED LAMP, OPS GOOD.SDR UALA2011062703162Idg · failedLEFT GEN DRIVE OFF WITH ENG SHUT DOWN. REPLACED LEFT GCU, NO HELP. REPLACED LT IDG. LT GEN DRIVE "DRIVE" LIGHT INOPERATIVE. REPLACED LT IDG. FOR TROUBLESHOOTING, SWAPPED LEFT AND RIGHT ENG GCU'S.SDR UALA2011062703150Module · failedAT ARRIVAL PSEU BITE SHOWED LANDING GEAR LEVER SYSTEM NR 1 AND NR 2 UP AND DOWN. REPLACED LANDING GEAR CONTROL LEVER MODULE. CLEARED PSEU MEMORY.SDR UALA2011062703159Light · inoperativeNR 2 MED EXT EMERGENCY LIGHT INOPERATIVE.SDR UALA2011062703161Circuit Card · false activationAFTER ENG START RECEIVED A RT ENGINE FIRE LOOP 1 STATUS MESSAGE. REPLACED FIRE DETECTION CARD M683 PER MM, NO STATUS MESSAGE.SDR UALA2011062903192Metering Valve · malfunctionedAFTER TAXI FROM GATE-NOSE WHEEL STEERING JAMMED THEN SNAPPED TO THE LEFT FOR TURN ON TO RUNWAY. REPLACED NLG STEERING METERING VALVE PER MM. TAXI CHECKED GOOD.SDR UALA2011062703153Skin · dentedFWD CARGO DOOR DENT AFT EDGE OF DOOR, APPROX 4\ FWD OF AFT EDGE, CTR OF DOOR. DENT IS 1.25 X 1.25 X .046 DEPTH. FOUND IT OUT OF LIMITS PER SRM. DENT LESS THAN 10" FROM NEAREST CUTOUT. REMOVED DAMAGE. FABRICATED & INSTALLED FLUSH DOUBLER REPAIR.SDR UALA2011062703146Fire Loop · kinkedCHRONIC LEFT ENGINE FIRE LOOP 2 MESSAGE IN CRUISE, ALWAYS TESTED OK ON GROUND. NO FIRELOOP MESSAGE PRESENT UPON ARRIVAL AT GATE, INSPECTED NR 1 ENG FIRE LOOPS FOUND NR 4 DETECTOR LOOP 2 (TS5254B) KINKED. REPLACED PER MM, OPS CHECKED GOOD ON THE GROUND.SDR UALA2011062703148Angle · crackedNR 1 PYLON SUPPORT FOR FINGER SEAL WEAR ANGLE HAS CRACKS AT FASTENER HOLES ON BOTTOM OF PYLON. REMOVED FINGER SEAL ANGLE. PICK UP HOLES IN NEW ANGLE. STARTED TO INSTALL UPPER AFT ANGLE, LOWER SUPPORT WEB IN WORK AREA. COMPLETED INSTALLATIONSDR UALA2011062703158Angle · corrodedCORROSION AFT PIT JUST INSIDE OF DOOR LEFT SIDE, AROUND FLOOR FITTINGS. REMOVED CORRODED AREA OF 'Z' ANGLE. REPAIRED WITH SPICED IN NEW SECTION OF 'Z' ANGLE.
Back to Pratt & Whitney PW2037