Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011071403575Skin · puncturedLT WING AILERON UPPER SURFACE HAS NUMEROUS PUNCTURES TO COMPOSITE SKIN.SDR UALA2011071403576Skin · puncturedAIRCRAFT ENCOUNTERED MODERATE HAIL STRIKE ON GROUND IN DENVER. RT WING AILERON UPPER SURFACE HAS NUMEROUS PUNCTURES TO COMPOSITE SKIN. WILL CONTINUE TO MAP OUT AND EVAL DAMAGE. RT AILERON NEEDS TO BE REMOVED ACCOUNT OF DAMAGE. REMOVED RT AILERON & REPLACEDSDR UALA2011071403577Unknown · damagedHAIL DAMAGE.SDR UALA2011071403578Aileron · dentedNUMEROUS DENTS WITH POSSIBLE 2 PUNCTURES TO THE LT AILERON. APPROXIMATELY 18 INCHES OUTBOARD OF THE INBOARD EDGE.SDR UALA2011071403579Unknown · damagedHAIL DAMAGE. WILL CONTINUE TO MAP OUT AND EVAL DAMAGE.SDR UALA2011071503586Floorbeam · corrodedCABIN FLOORBEAM HAS CORR STA 1661, LBL 5 - 8. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGED T-CAP AND INSTALLED REPAIR. REF COAIR N-R 9946383. RPR T-CAP AND DOUBLER ANGLES INSTALLED.SDR UALA2011071503584Pan · gougedDOOR 2L HAS GOUGE IN HANDLE PAN. REMOVED AND REPLACED HANDLE PAN IAW SRM.SDR UALA2011071403564Shear Tie · corrodedCORROSION ON SHEAR TIE AT STA 1580 OUTBOARD OF STR 29R. MAJOR REPAIR ACCOMPLISHED: REMOVED SHEAR TIE AT STA 1580 ST 29R DUE TO EXCESSIVE MATERIAL LOSS AFTER CORROSION REMOVAL. FABRICATED NEW SHEAR TIE IAW SRM. TREATED AND PRIMED IAW AMM AND INSTALLED SHEARSDR UALA2011071403565Skin · damagedFUSELAGE HAS LIGHTNING STRIKE DAMAGE. ACCOMPLISHED PERMANENT REPAIR IAW SRM 53-00-01 RPR 6.SDR UALA2011071403549Sign · missingL SIDE OVERWING EXIT SIGN COVER MISSING. INSTALLED NEW OVERWING EXIT SIGN COVER ON LEFT SIDE.SDR UALA2011071403582Floorbeam · corrodedMAIN CABIN FLOORBEAM AT STA 1660 CORRODED AROUND FLOORBOARD MOUNT HOLES BL 0 TO LBL 30. REMOVED CORROSION AND FOUND TO BE WITHIN LIMITS OF SRM. ORIGINAL MATERIAL THICKNESS IS .125, REMOVED .011, AND REMAINING MATERIAL THICKNESS IS .1 14. ALODINED AND PRIMEDSDR UALA2011071303512Skin · damaged4 FT FWD OF DOOR 2L JUST ABOVE FLOOR LEVEL SKIN DAMAGED. DENT APPROX 4" LONG 2.5" WIDE .200 DEEP. GOUGE IN MIDDLE OF DENT IS APPROX .020 DEEP. BLENDED DAMAGE AREA. ACCOMPLISHED NDT INSPECTION ON DAMAGED AREA. NO CRACKS FOUND ON EXTERIOR AND INTERIOR OF FUSELASDR UALA2011071403547Floorbeam · corrodedCORROSION ON FLOOR BEAM AT STATION 365 RBL 60. MAJOR REPAIR. AFTER BLENDING CORROSION FOUND FLOORBEAM TO BE OUT OF LIMITS PER SRM. REMOVED DAMAGE IAW SRM, FABRICATED REPAIR PART ANGLES. FABRICATED STRAP & BEAM. INSTALLED ALL PARTS IAW SRM 53-00-51.SDR UALA2011071403563Skin · damagedFUSELAGE STA 1080 STR 8R SKIN HAS LIGHTNING DAMAGE. MAJOR REPAIR. REPAIRED PER SRM. REPAIRED IAW PWI E-88 T1437.SDR UALA2011071403548Skin · dentedSHARP DENT IN FUSE SKIN STA 406, STR 17L. MAJOR REPAIR ACCOMPLISHED: DOUBLER REPAIR ACCOMPLISHED PER SRM.SDR UALA2011071503599Transceiver · failedFLT CREW REPORTED NO RETURN ON RADAR, COLORS ARE ERRATIC. NO HELP WITH CHANGE OF TILT FUNCTIONS. RDR TEST NORMAL COLOR SCREEN. DEFERRED PER SAMC. FLT CREW COMPLIED WITH MEL 3443D. REPLACED WX TRANSCEIVER, TESTED OK. OPERATED WITH NORMAL RETURNS AND COLORSDR UALA2011071403546Tube · leakingON SHORT FINAL, C HYD QTY EICAS FLASHED TWICE. CENTER QTY SHOWING 35RF. FOUND STAB BRAKE RELEASE TUBE CRACKED. REMOVED AND REPLACED TUBE .SDR UALA2011071303506Oxygen Mask · improper partWRONG O2 HOSE AND BAG 1ST CLASS AREA. INSTALLED CORRECT MASK.SDR UALA2011071303508Actuator · leakingHYD FLUID ON BOTTOM SURFACE OF LEFT WING. OPERATED FLAPS AND SPEED BRAKES, NO LEAKAGE NOTED. CLEANED AREA AND CARRY FORWARD WITH RECHECK WITHIN 75 FLIGHT HOURS PER MM. FOUND AREA WET WITH HYD FLUID, CLEANED AREA. OPERATED HYD SYSTEMS IN AREA ON ACTIVE LEAKSDR UALA2011071303543Cable · twistedTILLER STEERING - STEERING FORCES ARE HIGH. CREW COMMENTS: NOSE STEERING TILLER HAS GRINDING-BAD BEARINGS FEEL. SLUGGISH RETURN TO CENTER. RUDDERS OKAY. FOUND NOSE GEAR STEERING CABLES TWISTED AFTER THE RUN THROUGH THE GUIDE. REMOVED CASTELLATED NUT AND SDR UALA2011071303545Computer · faultyAT LOW AIRSPEEDS ELEVATOR FEEL HARD TO PULL BACK YOKE. REPLACED ELEV FEEL COMPUTER IAW MM, LEAK CHECK GOOD.SDR UALA2011071503598Window · burnedCOCKPIT WINDOW L-1 HAS SMALL BURN MARK ON LOWER EDGE TOWARD THE RIGHT. REPLACED THE L1 WINDOW PER MM.SDR UALA2011071503600Eec · failedNR 1 ENG "LIMIT PROTECTION LIGHT " ON PEDESTAL AND EICAS MSG DISPLAYED. REPLACED NR 1 ENGINE EEC IAW AMM. MR73237 ON 26 OFF 2. IDLE RUN AFTER 30 SECONDS INCREASES IN FF 1.6 AND N2 73 PERCENT ON OWN. NOW HAVE P PMA EEC AND S PMA EEC MSGS ON EPCS. EEC NO HELSDR UALA2011071303498Crease Beam · corrodedCORROSION ON CREASE BEAM WEB AT STA 1120 - 1140. MAJOR REPAIR ACCOMLISHED: REMOVED WEB AND FABRICATED A REPLACEMENT. TREATED, PRIMED AND TOPCOATED AND INSTALLED NEW WEB IAW SRM.SDR UALA2011071303502Crease Beam · corrodedCORROSION CREASEBEAM INNER CHORD BETWEEN BS 1580-1600 AT LBL 60. MAJOR REPAIR ACCOMPLISHED: REPAIRED CREASE BEAM INNER CHORD BETWEEN PER EA PD 57-53-149. MINOR REPAIRSDR UALA2011071303539Oxygen Mask · inoperativeO2 TEST FAILED AFTER SERVICING. CAPTAINS O2 MASK BOX INOP. REPLACED WITH FIRST OBSERVERS MASK. CAPTAINS MASK TESTS OK, FIRST OBSERVERS MASK INOPERATIVE. CREW OXYGEN BOTTLE SHUTOFF VALVE LEAKS INTERMITTENTLY WHEN BACKED OFF QUARTER TURN FROM FULL OPEN PER MSDR UALA2011071103468Fuel Control · faultyAPU WILL NOT START 2 ATTEMPTS. HAS HISTORY, NO TIME. APU TESTER SHOWED IGV ACTUATOR TM RESISTANCE OHMS OUT OF TOLERANCE ON STATIC TEST. MAINTENANCE STATUS MSG SHOWED FAULT AT 35 PERCENT RPM. REPLACED IGV ACT, STARTED APU SEVERAL TIMES WITH NO PROBLEMS. TOLSDR UALA2011071103439B-Nut · looseHYD LEAK ON RT SIDE OFF FUSELAGE JUST AFT OF RT ELEVATOR. SECURED 'B' NUT CONNECTION ON THE LEFT YAW DAMPER SERVO. ACCMP'D HYD SYSTEM GENERAL EXTERNAL LEAK CHECK IAW MM, ALL CHECKS GOOD.SDR UALA2011071203489Battery · faultyTWO START ATTEMPTS - FAULT BOTH TIMES. REPLACED BATT WAS HOT WITH SLOW START FAULT MSG. REPLACED APU BATT AND APU BATT CHARGER. APU START WAS NORMAL. ALL MSGS WERE ALL ERASED.SDR UALA2011071303499Floorbeam · corrodedCORROSION ON FLOORBEAM AT BS 324 RBL 35-58 IN MAIN CABIN (N-R 2775N00263). MAJOR REPAIR ACCOMPLISHED: REPAIRED PER INSTRUCTIONS PROVIDED IN EA PD57-53-146 AND EVA 81001 WITHOUT DEVIATIONS.SDR UALA2011071203490Socket · missingLEFT CTR BOOST PUMP INOP. CTR L FUEL PUMP EICAS MSG AND NO TRANSFER INTO LEFT MAIN FUEL MAN. MAINT TEXT: OPB AND DD REFUSAL USING MEL 2822G LEFT CENTER PUMP INOP DUE PAYLOAD PENALTY AND ETOPS CRITICAL. TRANSFERED FUEL FROM MAIN TO CENTER TANKS, BOTH CENTERSDR UALA2011071103470Window · delaminatedTHE 1ST OFFICER'S WINDSHIELD'S VISIBILITY IS AFFECTED BY DEFECTS, REPLACE FIRST AVAILABLE. CREW COMMENTS: DELAMINATION LOWER LT CORNER. REPLACED NR 1 RIGHT WINDOW PER MM.SDR UALA2011071203486Chiller · faultyAFT GALLEY CHILLER RED FAULT LIGHT ON. DEACTIVATE CHILLER PER MEL. REMOVED AND REPLACED CHILLER ASSY.SDR UALA2011071103415Cap · missingEMERGENCY ESCAPE LIGHT END CAPS MISSING 6B, 9C & 13C. REPLACED CAPS.SDR UALA2011071103466Structure · damagedMAIN ENTRY DOOR 2R UPPER HINGE CUTOUT IS CRACKED. FERRIED IN FROM SEA FOR DOOR 2R UPPER HINGE CRACKED. MAIN ENTRY DOOR 2R UPPER HINGE CUTOUT IS CRACKED OVER .25 INCH. REPAIR IS DONE. EG WILL HAVE 8100-9. CONT INSTL INTERNAL MECH THEN RIG AND CLOSE UP TO ASDR UALA2011071103471Skin Panel · crackedGOT A CRACK INDICATION WHILE PERFORMING NDT 53-30-14 PT6 PROCEDURE AT STA 410 STR 4L APPROX 1-2 INCH LONG. CONTACTED ENGRNG. ACP'D INTERNAL HFEC. CHEM MILL EDGE IS CRACKED AT STA 406 AND 408 OF UPPER SKIN PANEL. CRACKS ARE MARKED. CROWN SKIN PANEL RPLC'D SDR UALA2011071103431Handle · obstructedTHE 3R MED ARMING PLACARD NOT CORRECT POSITION WHEN ATTD DISARMED DOOR. FLIGHT ATTENDENT REPORTED THAT THE ARMING HANDLE WOULD NOT GO PASS THE ARMING PLACARD. REMOVED BOTTLE CAP FROM UNDER SLIDE GRIT BAR SLIDE ARMS AND DISARMS NORMALLY.SDR UALA2011071103465Window · delaminatedTHE LEFT SIDE OF CAPTAIN'S WINDSHIELD SHOWS DELAM. MEASURES ABOUT 1.5 INCHES INTO WINDOW AND 5.75 INCHES IN HEIGHT. CAPTAIN STATES THAT THE VISUAL QUALITY IS DECREASED BY THE DELAMINATION. REPLACED NR 1 WINDSHIELD, SEALED AND TORQUED TWICE. STILL NEED TO TSDR UALA2011071103469Sign · out of positionCREW REPORT: RIGHT SIDE OVERWING EXIT SIGN FELL DOWN NEEDS REPAIR. RE-INSTALLED SIGN.SDR UALA2011071203496Hinge · defectiveCEILING PANEL DISLODGED AT ROW 39-40 IN MOD TURB. REPLACED HINGE AND LATCH.SDR UALA2011071103409Probe · faultyTOP OF DESCENT NOTED LEFT ENG EPR RADIAL AND NUMBERS MISSING ON UPPER CRT AND SEI DISPLAY. SFO INF- :PT2-TT2 PROBE 564-0122 NOT AVAIL SFO. ORDERED PROBE AOG LAX. REPLACED NR 1 PT2-TT2 PROBE IAW AMM. TEST OKAY IAW AMM. IDLE RUN NR 1 ENGINE, NO MSG DISPLAYESDR UALA2011071103464Lanyard · out of positionF/A REPORTS 1R DOOR WILL NOT ARM. FOUND LANYARD BELOW GIRT BAR. REPOSITONED DOOR AND OP CHECKS OKAY.SDR UALA2011070803397Clamp · damagedNLG HARNESS CLAMP DAMAGED. REPLACED CLAMP IAW EG5122 NLG HARNESS CHECK.SDR UALA2011070803393Transceiver · faultyAFTER TURNING ON WX RADAR GOT WXR FAIL MESSAGE SAMC TEXT: CREW REPORT CB F2 ON P11 FOR WXR RT POPPED. REPLACED WXR SCANNER ANTENNA AND WXR TRANSCEIVER. OPERATIONAL TEST OK WITH NO ABNORMALITIES NOTED. ALSO REPLACED WXR CONTROL PANEL (P/N 2041223-0427 - S/NSDR UALA2011070803394Cap · shortedOFF WING ESCAPE SLIDE RT SYS PRESS BOTTLE SQUIB DISCONNECTED AND SHORTING CAP INSTALLED AND SAFETY PIN INSTALLED IN MASTER CONTROL VALVE. REINSTALLED CONN AND REMOVED PIN AND SHORTING CAP PER MM. ACCOMPLISHED INSPECTION PIN REMOVED AND STOW PRESSURE GOOD.SDR UALA2011070703367Doubler · corrodedCORROSION ON DOUBLER ON AFT PRESSURE DECK BS 1681 RBL 5-40 MAIN CABIN (N-R 2775N00390). MAJOR REPAIR ACCOMPLISHED: REPLACED DOUBLER SAME SIZE AND SHAPE PER SRM.SDR UALA2011070703368Stringer Splice · corrodedCORROSION ON PRODUCTION SPLICE AT BS 1460 S-28L. (N-R 2775N00421). MAJOR REPAIR ACCOMPLISHED: FABBED AND INSTALLED STR SPLICE AND ATTACH CLIP AT STA 1460, S28L PER SRM ON PEMCO NR 2775N00421.SDR UALA2011070703364Wire · chafedWHEN FUELING BOTH DC FUEL CONTROL AND FUEL PANEL CB POPPED. RESET AND POPPED WHEN FUEL DOOR OPENED. REMOVED FUELING PANEL AND REPAIRED CHAFING WIRING BEHIND PANEL. REINSTALLED AND OPS CHECK GOOD.SDR UALA2011070703360Cap · defectiveRAT GREEN PRESS LIGHT IS OUT. REPLACED SWITCH CAP FOR RAT RELEASE SWITCH, OPS NORMAL.SDR UALA2011070703361Battery · faultySTATUS MSG APU OIL QTY LIGHT CAME ON 2.8 HRS INTO FLT. APU RAN FOR GEN MEL ITEM. MAINT TEXT: NO APU LEAKS UPON ARRIVAL. SERVICED 1.5 QTS OIL IN APU. RAN APU AND FOUND NO LEAKS. TAIL PIPE DRY. HUNG START AT 40 PERCENT WITH AUTO SHUT DOWN TWICE. REPLACED
Back to Pratt & Whitney PW2037