What was found
FLOORBEAM AT BS 660 HAS TOOLING MARK AT RBL 37-41.5 (N-R 2775N00559). MAJOR REPAIR ACCOMPLISHED: FABBED AND INSTALLED SUPPORT BEAM, ANGLES AND STRAPS AT STA 660, RBL 35 - 51 PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM AT BS 660 HAS TOOLING MARK AT RBL 37-41.5 (N-R 2775N00559). MAJOR REPAIR ACCOMPLISHED: FABBED AND INSTALLED SUPPORT BEAM, ANGLES AND STRAPS AT STA 660, RBL 35 - 51 PER SRM.