Pratt & Whitney PW2037
Service difficulty reports · 12,810
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2037' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011011700247Switch · dirtyALL EMERGENCY LIGHTS INOP FROM MID CABIN AND AFT. SAMC TEXT: WHEN LOCAL AMT ARRIVED AT AIRCRAFT, ALL EMERGENCY LIGHTS WERE OFF. TURNED EMERGENCY LIGHT SW ON, AND ALL EMERGENCY LIGHTS WERE INOP FROM OVERWING TO AFT OF CABIN. SUSPECT BATTERY PACKS DEPLETED ANSDR UALA2011011800293A/C Pack · noisyCOCKPIT NOISE INFLIGHT. CREW INFLIGHT TROUBLESHOOTING FOUND THAT LT PACK WAS ALSO CAUSING PROBLEM, SEE DF842. CLEANED CTR AIR NOZZLE ASSY 23 AFT, ALL CLOGGED RESTRICTOR PLATES AND REPLACED RECIRC FAN FILTERS. FLT DECK NOISE 70 DB WITH LT FAN ON AND 72 WITH SDR UALA2011011400225Pitot Tube · shortedFIRST OFFICER PITOT TUBE GLOWING RED HOT ON GROUND. FOUND RIGHT AUX PITOT TUBE HEATER SHORTED TO CASING. REPLACED RIGHT AUX PITOT TUBE, HEATER CIRCUITS TEST OKAY.SDR UALA2011011400232Light · looseEMERGENCY LIGHT STRIP 6B TORN. REATTACHED LIGHT STRIP. OPS CHECKED OK.SDR UALA2011011200188Floorbeam · corrodedCORROSION DAMAGE ON THE UPPER SURFACE OF THE FLOORBEAM AT BS 324 BETWEEN RBL 50 AND RBL 60. THE SECTION WAS REMOVED AND REPLACED PER INSTRUCTIONS PER PD57-53-069 AND SUPPORT FROM UA EVA 80462.SDR UALA2011011200183Floorbeam · corrodedCORROSION FOUND AT STATION 365 AT WL 208. MAJOR REPAIR ACCOMPLISHED: FABRICATED AND INSTALLED REPAIR AT STA 365 FLOORBEAM FROM LBL 12 TO RBL 70 IAW SRM 53-00-5 1 REPAIR 1.SDR UALA2011011200184Floorbeam · corrodedCORROSION ON FLOORBEAM AT STATION 1640 RBL 3. MAJOR REPAIR ACCOMPLISHED: FABRICATED AND REPLACED FLOORBEAM UPPER CHORD STA 1640 BTWN RBL 3 AND RBL 69 IAW.SDR UALA2011011200179Life Vest · missingSEAT 18D AND 19A MISSING LIFE VEST UNDER SEATS. REPLACED MISSING LIFE VESTS.SDR UALA2011011200181Light · inoperativeEMERGENCY LIGHT INOP AT AFT LEFT CARGO COMPT. REMOVED AND REPLACED LAMP AT AFT LEFT EXT EMERGENCY LIGHT ASSY. OPS CHECKS GOOD.SDR UALA2011011200180Feeder Cable · faultyEMERGENCY LIGHT STRIP AT 14ABC DAMAGED. EMERGENCY LIGHTS ARE INOP FROM ROW 9 TO ROW 14. EMERGENCY LIGHT PULLED UP AND CUT IN HALF AY ROW 14. REPLACED CABLE ASSY AND 2 EACH LAMPS AND FLOOR TRACK TOP HOUSING AND OP CHECKS GOOD.SDR UALA2011011300211Start Valve · inoperativeCREW REPORTED NR 2 ENG DOES NOT ROTATE WHEN START VALVE IS OPENED. START VALVE LIGHT CAME ON AND WENT OUT, BUT NO ROTATION. OPERATED START VALVE MANUALLY. REPLACED START VALVE.SDR UALA2011011300209Shutoff Valve · faultyRT ENG BLEED WILL NOT CLOSE WITH SWITCH OFF AND ISOLATION VALVE XSED. ALONG WITH ABOVE PROBLEM, WITH APU SUPPLYING AIR, ENG OFF, RT ENG BLEED OFF LIGHT EXTINGUISHES, APU BLEED VALVE LIGHT ILLUMINATES, DUCT PRESSURE DROPS, THEN APU BLEED VALVE LIGHT EXTINGUISHSDR UALA2011011200178Fairing · disconnectedLEFT WING L/E OF FLAP FAIRING OTBD OF LEFT ENG IS NO LONGER CONNECTED TO WING. INSTALLED BOLTS. FAIRING SECURE.SDR UALA2011011300207Window · overheatedFIRST OFFICER'S SLIDING WINDOW IS HOT TO THE TOUCH ON LOWER RIGHT AND ENTIRE LEFT SIDE. SAMC TEXT: DISCOLORATION IS APPARENT ON RIGHT SIDE OF THE SLIDING WINDOW. REPLACED NR 2 RT MOVEABLE WINDOW PER MM.SDR UALA2011011200160Skin · punctured4L MED HAS INNER SKIN PUNCTURED AT UPPER HINGE. REPAIR ACCOMPLISHED ON 8130 TRACKING NR 377899, DAMAGED WAS REPAIR IAW REO- G13451 REV A DATED 1-5-11.SDR UALA2011011000153Structure · damagedRAMP REPORTED RIGHT WING TO BODY FAIRING PANEL NR 198AR DAMAGE, AFT LOWER CORNER OF PANEL DAMAGE 7" BY 8". PICTURES OF DAMAGE ARE ON RVI SIGHT. FABRICATED HORIZONTAL EXTRUDED CHORD & SENT FOR HEAT TREATMENT. DOUBLER ANGLE REPAIR IAW SRM & GNMM. CHORD ANGLSDR UALA2011011300208Cap · missingEMERGENCY ESCAPE LIGHTING STRIPED CAPS MISSING 6B, 13C, 34C, AND 1L CLOSET. REPLACED MISSING EMERGENCY LIGHT END CAPS.SDR UALA2012011100240Bearing · wornL1 DOOR UPPER HINGE AND BODY TORQUE TUBE BEARINGS ARE WORN MAKING DOOR HARD TO CLOSE. DOOR WILL STILL OPEN AND CLOSE MORE THAN NORMAL FORCE NEEDED TO BE USED. DOOR UPPER LATCHING CAM PLATES AND ROLLERS DAMAGED. REPLACED LATCH CAM AND UPPER FWD ROLLER BEARINSDR UALA2011011000157Switch · faultyAPU AUTO SHUT DOWN RESTARTED AND AUTO SHUT DOWN SECOND TIME. APU ECU FAULTED GEN FILTER. ACCOMPLISHED FIM REF MM SHEET 1. BLOCK 1 CHECKED GOOD. BLOCK 2 HAD HIGH RESISTANCE 1.6 OHM'S. REPLACED APU GENERATOR DELTA P SWITCH PER MM. APU OPS CKS GOOD. NO ECUSDR UALA2011011000130Feeder Cable · looseEXIT ROW LIGHTING IS LOOSE ABEAM SEATS 1AB. REPLACED EMERGENCY POWER FEEDER CABLE AT 1L. OPERATES NORMALLY.SDR UALA2011011000143Feeder Cable · faultyEXIT ROW LIGHTING IS LOOSE ABEAM SEATS 1AB. REPLACED EMERGENCY LIGHT POWER FEEDER CABLE AT 1L. OPERATES NORMALLY.SDR UALA2011011000146Floorbeam · crackedCABIN FLOORBEAM STA 700 UPPER FLANGE CRACKED AT LT OTBD AND LT INBD SEAT TRACK. ACCOMPLISHED ON DOCK WU'S F5475P AND F5476PPER SRM AND EVA 80412. ACCOMPLISHED FINAL INSP OF CABIN FLOORBEAM REPAIR PER EVA 80412.SDR UALA2011011000158Anti-Ice Valve · faultyWITH WING ANTI-ICE SWITCH SELECTED ON, RT VALVE LIGHT REMAINED EXTINGUISHED. NO EICAS MESSAGE DISPLAYED. LIGHT TESTED OK. WING ANTI-ICE VALVE APPEARS TO WORK NORMAL. REPLACED AND OPS CHECKED RT WING ANTI-ICE VALVE PER MM.SDR UALA2011011000159Switch · failedAPU NO START ON THE GROUND. APU FAILED TO START SEVERAL TIMES. BIT OF ECU SHOWS CURRENT LAST RUN, RUN ABORTED "AC START CIRCUIT". APU DOOR CONTROL SWITCH REPLACED. RAN APU FOR 2 HOURS AND PERFORMED MULTIPLE APU STARTS. APU CHECKED GOOD, NO FAULTS.SDR UALA2011011000156Fan · faultyOVERHEAT ON EQUIP COOLING OK IN ALT ON GROUND. ALT OK. DUE ETOPS SENSITIVE, IF UNABLE TO DUPLICATE, REPLACED NR 1 POSITION EQUIP COOLING FAN PER MM.SDR UALA2011011000138Strap · out of positionCAN'T ARM DOOR 3L. REPOSITIONED STRAP. OPS NORMAL.SDR UALA2011011000128Hose · leaking3 OF THE 4 RT WING DRY BAY DRAIN HOLES ARE LEAKING FUEL IN EXCESS OF DISPATCH LIMITS. WITH RIGHT FUEL TANK FULL AND STATIC, NO LEAKS NOTED. PRESSURIZED RIGHT ENG FUEL FEED LINE AND FOUND RUNNING LEAK. CHECKED BAY 2 WITH BORESCOPE. FOUND FUEL FEED FLEX HOSESDR UALA2011011000126Socket · burnedELECTRICAL ODOR IN AFT LAV, FLT DIVERTED. TURNED OFF AFT LAV WATER HEATER, ALL GALLEY POWER AND CABIN LIGHTS. PULLED CB FOR LAV FLUSH MOTOR IN AFT CABIN. FLT ATTENDANT REPORTED NO CHANGE IN ODOR. PLACED UTILITY BUSSES TO OFF. STILL NO CHANGE. ACCOMPLISHESDR UALA2011011000132Drain · cloggedICE FOUND IN THE LOWER E/E AND NOSE TUNNEL BILGE AREA. GRAY WATER HAS BEEN SUCTIONED OUT AND DRIED. ALSO, DRAIN LINE HAS BEEN UNCLOGGED.SDR DALA1110680691Skin · dentedDENT FUSELAGE STA 566 AT S27L. C/W ERA 489002-14 ORIG.SDR UALA2011010700112Charger · faultedAPU FAILED TO START. FAULT LIGHT ILLUMINATED AND EICAS MESSAGE. APU FAULT DISPLAYED. REPLACED APU. AFTER APU REPLACEMENT STILL UNABLE TO START, FOUND BATTERY VOLTAGE DURING CRANK CYCLE AT 8VDC. REPLACED APU BATTERY AND CHARGER PER MM. OPS CKS NORMAL.SDR UALA2011010700113Switch · faultyLEFT RESERVOIR LIGHT ON OVERHEAD ILLUMINATED. LOW PSI RESERVOIR LIGHT ON AFTER TURNING ON AND OFF ELEC PUMPS, RAN LEFT ENG AND THE LOW PSI RESERVOIR LIGHT STAYED OUT. WRENCH CHECKED LINES AND FOUND NO LEAKS. INSPECTED PLUMBING AND B-NUTS, NO LEAKS FOUND. RSDR UALA2011010700111Vent · leakingNR 1 ENG OIL PRESS LOW, 075 PSI. ENG OIL PRESS LIGHT ON OR FLUCTUATING. EICAS MESSAGE ENG OIL PRESS DISPLAYED. LT OIL PRESS LIGHT WITH FLUCTUATING PSI 72-89. OIL QTY ZERO. NO ENGINE SHUT DOWN. OIL QTY WENT TO ZERO WHILE ENGINE AT FLT IDLE. AFTER SHUTDOWNSDR DL757101246Skin · damagedFUSELAGE/CROWN SKIN STA 1340, STR 3R REPAIR IAW ERA 090306-14C/W ERA 090306-14. ORIGINAL DIFFICULTY DATE: 5-27-2004SDR UALA2011010600087Shutoff Valve · faultyLEFT ENG PRSOV IS FAULTY. CHECKED PRSOV WITH HEALTH CHECK KIT, AND VERIFIED VALVE POSITION SWITCH WAS DEFECTIVE. REPLACED NR 1 ENG PRSOV PER MM. VERIFIED NEW VALVE WAS GOOD FROM STOCK WITH HEALTH CHECK. LEAK CHECKED GOOD.SDR UALA2011010600076Control Switch · failedREPLACED EMERGENCY LIGHT CONTROL SWITCH IN AFT ATTENDANT PANEL (S10579), TEST PER MM. OPS CHECKED OK.SDR UALA2011010600077Feeder Cable · damagedDUE TO EMERGENCY LIGHTS ILLUMINATED FOR INDETERMINATE AMOUNT OF TIME, ELECTRICAL POWER SHOULD REMAIN ON AIRCRAFT. BATTERIES WILL BE FULLY CHARGED DUE TO TIME TABLE CHART. REPLACED FEEDER LINE IN AFT SECTION OF ACFT. OPS CHECKED EMERGENCY LIGHTS, SYS OPS NORSDR UALA2011010600078Feeder Cable · faultedFOUND EMERGENCY LIGHT INOPERATIVE IN FRONT OF AFT LAV. REPLACED FEED CABLE PER WDG.SDR UALA2011010600088Light · unsecureEMERGENCY ESCAPE PATH LIGHTING NOT SECURE BETWEEN ROWS 12 AND 13. SECURED EMERGENCY LIGHT. OPS CHECKED NORMAL.SDR UALA2011010600089Battery Pack · inoperativeDURING OPS CHECK OF EMERGENCY LIGHTS, FOUND CENTER SECTION INOP. REPLACED EMERGENCY LIGHT BATTERY OUTBOARD OF SEAT 17 A, B, C. OPS CHECKED NORMAL.SDR UALA2011010700125Engine · flamed outENG 2 FLAMEOUT.SDR UALA2011010600073Girt Bar · misinstalledNR 1 LT MED GIRT BAR MECHANISM HARDWARE, HAS NUT HITTING DOOR FRAME. REMOVED AND INSTALLED GIRT BAR MECHANISM HARDWARE CORRECTLY IAW UAL SM.SDR UALA2011010600074Girt Bar · misinstalledNR 1 RT MED GIRT BAR MECHANISM HARDWARE HAS NUT HITTING DOOR FRAME. REMOVED AND INSTALLED GIRT BAR MECHANISM HARDWARE CORRECTLY IAW UAL SM.SDR UALA2011010600102Circuit Card · malfunctionedRT ENG NR 1 FIRE LOOP STATUS MESSAGE DISPLAYED ON EICAS. REPLACED AFOLTS CARD M10274 AND FIRE CONTROL CARD M683 R ENG FIRE LOOP 1 PER MM. CHECKED OKAY. CLEANED RT ENGINE FIRE LOOP 1 CONNECTIONS. FIRE TEST CK OK AND OPERATED ENGINE AND TAXIED ACFT. CHECKEDSDR UALA2011010600075Cap · missingEMERGENCY ESCAPE LIGHTING STRIP END CAP MISSING AT 6B. REPLACED EMERGENCY LIGHT STRIP BLACK END CAP. ALL EMERGENCY LIGHTS WORKED NORMAL.SDR UALA2011010700118Light · inoperativeRIGHT LAV EMERGENCY LIGHT STRIP INOPERATIVE. REPLACED EMERGENCY LIGHT STRIP IN FRONT OF K LAV. OPS CHECKED GOOD.SDR DALA1100830623Power Supply · inoperativeDURING A LAYOVER CHECK, MX FOUND THE EMERGENCY EXIT LIGHT OVER DOOR 3R VERY DIM. MX REPLACED THE POWER SUPPLY. OPS CHECK WAS GOOD.SDR UALA2011010300035Radar · failedWEATHER RADAR FAILED, DISPLAYED ON HSI. WHEN IN WEATHER RADAR TEST. ANTENNA AND RT DISPLAYED. REPLACED SCANNER ASSY. CHECKS OK.SDR UALA2011010400059Seal · leakingNR 2 ENG HIGH OIL CONSUMPTION EXCEEDS LIMIT. RAN ENGINES PERFORMED BAG AND BREATHER, NO FLUID LOSS FROM DRAINS NOTICED. WIPED COWL BEFORE RUN AND FOUND OIL LEAKAGE FROM DEOILER PORT AFTER RUN. REPLACED DEOILER SEAL AND RING. NO LEAKS NOTED.SDR UALA2011010300034Control Valve · inoperativeDUE TO HISTORY OF LT PACK FLOW CONTROL VALVE NOT CLOSING, REPLACE LT PACK FLOW CONTROL VALVE. REPLACED LT FLOW CONTROL & SHUTOFF VALVE, OP CKD GOOD.
Back to Pratt & Whitney PW2037